Filtry
wszystkich: 1328
wybranych: 1054
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: IMPEDANCE CONVERTORS
-
Feasibility Study of Three-Phase Modular Converter for Dual-Purpose Application in DC and AC Microgrids
PublikacjaThe modern concept of a universal converter is intended as a power converter suitable for application in both dc or ac grids using the same external connectors. This novel family was recently proposed to allow an easier integration of renewable energy sources and energy storage systems, interfacing with dc/ac grids and/or loads with a minimum redundancy of power switches and passive elements. This kind of solution and applications...
-
Błędy wyznaczania charakterystyk częstotliwościowych impedancji uzwojeń magnesów nadprzewodzących
PublikacjaW artykule przedstawiono zagadnienia związane z opracowaniem systemu do wyznaczania impedancji uzwojeń magnesów nadprzewodzących w funkcji częstotliwości. Omówiono strukturę sprzętową systemu i oprogramowanie, a także dokonano podstawowej analizy metrologicznej określając na podstawie badań symulacyjnych błędy wyznaczania modułu i argumentu poszukiwanej impedancji. Pokazano również przykładowe wyniki uzyskane przy użyciu omawianego...
-
Badania eksperymentalne laboratoryjnego modelu miernika impedancji pętli zwarciowej.
PublikacjaW artykule przedstawiono wyniki badań eksperymentalnych laboratoryjnego modelu miernika impedancji pętli zwarciowej. Badania przeprowadzono dla parametrów badanego obwodu i miernika, jakie można spotkać w praktyce. Wyniki badań przedstawione w formie wykresów wykazują, że miernik ten charakteryzuje się dobrymi parametrami metrologicznymi.
-
Pomiary impedancji szkliwa zębów w zakresie niskiej częstotliwości.
PublikacjaCelem pracy była ocena in vitro wartości impedancji szkliwa zębów w zakresie niskiej częstotliwości oraz zmian impedancji pod wpływem wilgotności. Pomiarami objęto szkliwo bez zmian, szkliwo z pęknięciami oraz obszary zmienione w wyniku demineralizacji i próchnicy. Wyznaczono zakres zmian impedancji w wymienionych przypadkach.
-
Analiza impedancji sieci prądu stałego w instalacjach fotowoltaicznych
PublikacjaW artykule przedstawiono analizę impedancji różnicowej i wspólnej, sieci DC instalacji fotowoltaicznej. Badania impedancji przeprowadzono wykorzystując model matematyczny przygotowany w oparciu o teorię linii długiej. Otrzymane wyniki porównano z pomiarami laboratoryjnymi wykonanymi za pomocą analizatora impedancji.
-
Sposób obliczania parametrów impedancji operatorowej fragmentu obiegu krwi
PublikacjaPrzedstawiono etapy opracowania przebiegów rejestrowanych w czasie badań medycznych, które mogą służyć do określenia parametrów zastępczej impedancji operatorowej odwzorowującej wybrany fragment obiegu krwi. Na podstawie tak otrzymanej impedancji, możliwe jest określenie konfiguracji zastępczego obwodu elektrycznego fragmentu krwiobiegu. Z zastosowaniem programu, np. PSprice, możliwe jest symulacyjne badanie fizjologicznych zaburzeń...
-
Analiza impedancji sieci prądu stałego w instalacjach fotowoltaicznych
PublikacjaDokonano analizy impedancji sieci prądu stałego w instalacji fotowoltaicznej. Analizę tę przeprowadzono pod względem predykcji charakterystyki zaburzeń elektromagnetycznych generowanych przez instalacje PV. Badania przeprowadzono zarówno dla zaburzeń różnicowych, jak i wspólnych. Zastosowano podejście analityczne - wykorzystując teorię linii długiej oraz pomiary wykonane na stanowisku laboratoryjnym.
-
Pomiar impedancji elementów sieci elektroenergetycznych przy napięciu odkształconym
PublikacjaW pracy przedstawiono zagadnienia pomiaru impedancji elementów sieci elektroenergetycznych. Przeprowadzono analizę wpływu odkształcenia napięcia sieci na błędy pomiaru przy stosowaniu metody technicznej. Badania i obliczenia błędów przeprowadzone zostały dla wybranych typów odkształceń krzywej napięcia i różnych parametrów obwodu badanego.
-
Method of earth fault loop impedance measurement without nuisance tripping of RCDs in 3-phase low-voltage circuits
PublikacjaVerification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5–20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits...
-
Study on surface termination of boron-doped diamond electrodes under anodic polarization in H2SO4 by means of dynamic impedance technique
PublikacjaAnodic oxidation is a popular way to modify termination bonds at boron doped diamond electrodes altering their electrochemical and physicochemical properties. Our studies, performed with dynamic electrochemical impedance spectroscopy technique, supported with X-ray photoelectron spectroscopy and ellipsometry analysis prove its utility in continuous on-line monitoring of impedance changes on the electrode surface under polarization...
-
The impact of air humidity on the operation of proton exchange membrane fuel cells determined using dynamic electrochemical impedance spectroscopy
PublikacjaThis paper describes the changes in the fuel cell impedance across a range of current loads and humidity changes. The changes of each equivalent circuit parameters representing specific processes occurring in fuel cells, as a function of humidity and current changes, were determined. Within the combined scope of current and humidity, the optimal working conditions of the cells were determined, corresponding to the lowest impedance...
-
The extended model predictive-sliding mode control of three-level AC/DC power converters with output voltage and load resistance variations
Publikacja -
Modular power converter with superconducting magnetic energy storage for electric power distribution system — Analysis and simulation
PublikacjaThis paper describes selected issues concerning realization of energy storage system (ESS) designed to operate in power distribution system. This paper presents a modular approach of 300 kVA power converter operating with superconducting magnetic energy storage (SMES), which gives high dynamics together with high power and suitable capability for instantaneous energy storage. Analysis and simulation studies of selected power converter...
-
space-vector pulse width modulation for three-level npc converter with the neutral point voltage control
PublikacjaPrzedstawiono strategię modulacji PWM dla trójpoziomowych falowników NPC z predykcją i kompensacją asymetrii rozkładu napięcia na kondensatorach obwodu pośredniczącego
-
<title>MatLab script to C code converter for embedded processors of FLASH LLRF control system</title>
Publikacja -
Evaluation of VSC Impact on Power System Using Adequate P-Q Capability Curve
PublikacjaRenewable energy sources, which are becoming increasingly popular, often use a voltage source converter (VSC) for connection to the power system. Assessing the effects of connecting such a source to the power system is essential to ensure the proper operation of the power system and the connected source. For this purpose, it is necessary to know the range of active and reactive power generation by the converter. The authors indicate...
-
Balancing energy consumption in limited power grid with active front-end and three phase dual active bridge system
PublikacjaPaper deals with simulation analysis of bidirectional power converters system for charging station of electric vehicle in condition of limited power source in city infrastructure. In case of incapability to provide additional power supply through the grid by virtue of historical, architectural and economic reasons it is possible to solve this issue by implementation of mobile battery-powered supply source. The proposed bidirectional...
-
Pomiary impedancji pętli zwarciowej w obwodach chronionych wyłącznikami różnicowoprądowymi
PublikacjaW referacie przedstawiono teoretyczne podstawy pomiaru impedancji pętli zwarciowej w sieciach i instalacjach niskiego napięcia. Omówiono czynniki wpływające na dokładność pomiaru. Szczególną uwagę zwrócono na pomiary impedancji pętli zwarciowej w obwodach chronionych wyłącznikami różnicowoprądowymi. Przedstawiono wyniki badań wybranych mierników impedancji pętli zwarciowej i praktyczne wnioski odnośnie do ich stosowania w obwodach...
-
Metoda wektorowa pomiaru impedancji pętli zwarciowej w obecności zakłóceń.
PublikacjaW artykule przedstawiono problematykę pomiaru impedancji pętli zwarciowej w sieciach niskiego napięcia. Celem była analiza i badanie nowej metody pomiarowej, która pozwoliłaby wyznaczyć poprawnie wartość impedancji pętli zwarciowej w obecności występujących zakłóceń sieciowych. Ma to podstawowe znaczenie dla oceny skuteczności ochrony przeciwporażeniowej oraz jakości energii elektrycznej.
-
Ograniczenia wirtualnego miernika impedancji opartego na karcie akwizycji danych
PublikacjaW artykule przedstawiono wirtualny miernik parametrów elementów RLC, zrealizowany w oparciu o komputer PC z zainstalowana kartą akwizycji danych(PCI-6040E) wyposażoną w przetworniki a/c i c/a. Analizowano właściwości metrologiczne miernika zależne od parametrów zastosowanej karty. Przeprowadzono badania symulacyjne błędu pomiaru pojemności uwzględniajace rozdzielczośc i częstotliwośc próbkowania przetwornika a/c oraz jego czas...
-
Pomiar impedancji pętli zwarciowej w instalacjach z wyłącznikami różnicowoprądowymi
PublikacjaW referacie przedstawiono wyniki badań wybranych mierników impedancji pętli zwarciowej i praktyczne wnioski odnośnie do ich zastosowania w obwodach z wyłącznikami różnicowoprądowymi. Przedstawiono również ocenę zachowania się wybranych wyłączników różnicowoprądowych przy pomiarze impedancji pętli zwarciowej.
-
Pomiar impedancji pętli zwarciowej w instalacjach z wyłącznikami różnicowoprądowymi
PublikacjaW artykule przedstawiono wyniki badań wybranych mierników impedancji pętli zwarciowej i praktyczne wnioski odnośnie do ich stosowania w obwodach z wyłącznikami różnicowoprądowymi. Omówiono zachowanie się wybranych wyłączników różnicowoprądowych przy pomiarze impedancji pętli zwarciowej. Zwrócono też uwagę na specjalne metody pomiarowe, przeznaczone do obwodów z wyłącznikami różnicowoprądowymi.
-
Pomiary impedancji pętli zwarciowej w obwodach chronionych wyłącznikami różnicowoprądowymi
PublikacjaPrzedstawiono teoretyczne podstawy pomiaru impedancji pętli zwarciowej w sieciach i instalacjach niskiego napięcia. Omówiono czynniki wpływające na dokładność pomiaru. Szczególną uwagę zwrócono na pomiary impedancji pętli zwarciowej w obwodach chronionych wyłącznikami różnicowoprądowymi. Przedstawiono wyniki badań wybranych mierników impedancji pętli zwarciowej i praktyczne wnioski odnośnie do ich stosowania w obwodach z tymi wyłącznikami....
-
Evaluation of citric acid corrosion inhibition efficiency and passivation kinetics for aluminium alloys in alkaline media by means of dynamic impedance monitoring
PublikacjaA novel approach is proposed for constructing the adsorption isotherm in corrosion studies, based on a well-known interaction between citric acid and aluminium in alkaline electrolytes. Our approach utilizes the instantaneous impedance measurements via Dynamic Electrochemical Impedance Spectroscopy in galvanostatic mode (g-DEIS). Unlike other common tools, g-DEIS delivers exact information about the concentration required for full...
-
Dynamic electrochemical impedance spectroscopy and polarization studies to evaluate the inhibition effect of benzotriazole on copper-manganese-aluminium alloy in artificial seawater
PublikacjaPrzeprowadzono badania wpływu benzotriazolu (BTA) na korozję nowego typ mosiądzu (CMA) w środowisku syntetycznej wody morskiej przy użyciu dynamicznej elektrochemicznej spektroskopii impedancyjnej (DEIS), techniki polaryzacji rezystancyjnej i ekstrapolacji krzywych Tafela. Wyniki pomiarowe otrzymane przy użyciu tych metod wskazują spadek szybkości korozji wraz ze wzrostem stężenia BTA. Wskazuje to na inhibicyjne własności BTA w...
-
Solid State Conductivity of Optimized Polypyrrole Coatings on Iron Obtained from Aqueous Sodium Salicylate Solution Determined by Impedance Spectroscopy
PublikacjaIn this work the optimization procedure for corrosion resistance, surface analysis and electrical properties of PPy-Fe electrodes have been examined. Polypyrrole (PPy) film was electrochemically synthesized in a one step process from an aqueous solution of sodium salicylate and pyrrole with certain concentrations, different parameters and type of polymerization...
-
An integral-differential method for impedance determination of the hydrogen oxidation process in the presence of carbon monoxide in the proton exchange membrane fuel cell
PublikacjaThe impedance of a proton exchange membrane fuel cell powered by hydrogen contaminated with carbon monoxide, ranging from 150 to 300 ppb, is measured and discussed. The tested range of CO concentration complied with the fuel standard specified in the ISO standards. Studies of influence of CO contamination on operation of PEMFC are crucial for further development and commercialization of fuel cells for automotive applications. Based...
-
Determination of pseudocapacitance chan ges of nickel oxide NiO electrode with use of dynamic electrochemical impedancje spectroscopy
PublikacjaThe electrochemical capacitors (ECs) are attractive energy storage devices which can be applied in many electronic products (e.g., cameras, laptops, cell phones) or hybrid electric vehicles (HEV). The energy storage in ECs is based on capacitive (the electrical double layer charging/discharging) and pseudocapacitive (additional charge provided by faradic reaction) phenomena. Considering the electrodes exhibiting pseudocapacitance,...
-
NPC assessment in insulated DC/DC converter topologies using SiC MOSFETs for Power Electronic Traction Transformer
Publikacja -
Experimental EMI study of a 3-phase 100kW 1200V Dual Active Bridge Converter using SiC MOSFETs
Publikacja -
High Efficiency Dual-Active-Bridge Converter with Triple-Phase-Shift Control for Battery Charger of Electric Vehicles
PublikacjaAn optimal modulation scheme with triple-phase-shift (TPS) control could increase the efficiency in the entire load range for a dual-active-bridge (DAB) converter under wide output voltage range conditions. Therefore, this study proposes a convergent approach to TPS mode selection, coupled with an optimal modulation scheme, ensuring the circuit’s efficiency over the entire range in the realm of a high-power and high-efficiency...
-
A Canonical Switched Capacitor DC-DC Converter. A look at how the historical SC synthesis problem is getting solved
PublikacjaWe reconsider a solution to the historical problem in switched capacitor (SC) DC-DC converter synthesis. Specifically, we retackle the problem of constructing an SC twophase network realizing arbitrary voltage conversion ratio within rational bounds defined. Theoretical foundations are available in our earlier research [3] where a nonconstructive proof of existence was given. We briefly review and comment on known circuit solutions...
-
Analytical Estimation of Power Losses in a Dual Active Bridge Converter Controlled with a Single-Phase Shift Switching Scheme
PublikacjaMicro-grid solutions around the world rely on the operation of DC/DC power conver- sion systems. The most commonly used solution for these topologies is the use of a dual active bridge (DAB) converter. Increasing the efficiency and reliability of this system contributes to the improvement in the stability of the entire microgrid. This paper discussed an analytical method of energy efficiency and power loss estimation in a single...
-
Pomiar impedancji pętli zwarciowej w sieciach o odkształconej krzywej napięcia.
PublikacjaPrzedstawiono zagadnienia pomiaru impedancji pętli zwarciowej w sieciach o napięciu odkształconym. Przeprowadzono analizę wpływu odkształconego napięcia sieci na błędy pomiaru przy stosowaniu klasycznych metod i mierników impedancji pętli. Badania i obliczenia błędów przeprowadzone zostały dla wybranych odkształceń krzywej napięcia i różnych parametrów obwodu badanego.
-
Mikroprocesorowe mierniki impedancji pętli zwaciowej oparte na wektorach mierzonych napięć
PublikacjaW referacie przedstawiono problematykę pomiaru impedancji pętli zwarciowej w sieciach niskiego napięcia oraz omówiono wpływ czynników zakłócających występujących w sieci na wartości błędów pomiaru. Przedstawiono dwie metody i układy mierników do pomiaru modułu impedancji pętli zwarciowej i jej składowych ortogonalnych, oparte na zastosowaniu rezystancyjnego obciążenia pomiarowego. Pierwszy sposób opiera się na wyznaczeniu w miejscu...
-
Badanie metody pomiaru impedancji pętli zwarciowej wykorzystującej składowe fazora napięcia
PublikacjaW rozprawie badaniom poddano dwie metody pomiaru imepdancji pętli: metodę z przesunięciem oraz metodę wektorową. Celem tych badań była dogłębna analiza właściwości metrologicznych rozwiązań układowych, stosowanych w miernikach impedancji pętli zwarciowej z rezystancyjnym obciążeniem pomiarowym, z punktu widzenia realizowanych w nich procedur pomiarowych, oraz opracowanie i analiza metody do wzorcowania mierników impedancji pętli...
-
Wpływ wybranych błędów cząstkowych na dokładność pomiaru impedancji pętli zwarciowej
PublikacjaMierzoną wartość impedancji pętli zwarciowej otrzymuje się na podstawie pomiaru dwóch wartości napięć dla obwodu nieobciążonego oraz obciążonego, najczęściej rezystancją, która stanowi sztuczne zwarcie. W referacie przedstawiono analizę wpływu błędu pomiaru okresu napięcia sieci na dokładność wyznaczenia impedancji, dla metod wykorzystujących pomiary wartości skutecznych napięć. Jak pokazały przeprowadzone badania nawet niewielkie...
-
Nowa metoda pomiaru impedancji pętli zwarciowej bez wyzwalania wyłączników różnicowoprądowych
PublikacjaW referacie przedstawiono problematykę pomiaru impedancji pętli zwarciowej w sieciach z wyłącznikami różnicowoprądowymi (RCD - Residul Current Device) oraz zaproponowano nową metodę i układ do pomiaru impedancji pętli bez wyzwalania wyłączników RCD. Nowa metoda umożliwia przeprowadzenie pomiaru przy wykorzystaniu dużej wartości krótkotrwałego całofalowego prądu pomiarowego, co wpływa korzystnie na dokładność pomiaru. Metoda ta...
-
Pomiar impedancji pętli zwarciowej w obwodach z wyłącznikami różnicowoprądowymi selektywnymi
PublikacjaPomiar impedancji pętli zwarciowej w obwodach z wyłącznikami różnicowoprądowymi bezzwłocznymi jest kłopotliwy, ponieważ przy stosowaniu typowych mierników o prądzie pomiarowym rzędu 10-20 A zwykle następują zbędne zadziałania tych zabezpieczeń. W przypadku obwodów z wyłącznikami różnicowoprądowymi selektywnymi jest inaczej. W referacie wykazano, że pomiar ten można wykonać nawet miernikiem wielkoprądowym wymuszającym prąd o wartości...
-
Pomiar impedancji pętli zwarciowej w obwodach z wyłącznikami różnicowoprądowymi selektywnymi
PublikacjaPomiar impedancji pętli zwarciowej w obwodach z wyłącznikami różnicowoprądowymi bezzwłocznymi jest kłopotliwy, ponieważ przy stosowaniu typowych mierników o prądzie pomiarowym rzędu 10-20 A zwykle następują zbędne zadziałania tych zabezpieczeń. W przypadku obwodów z wyłącznikami różnicowoprądowymi selektywnymi jest inaczej. W artykule wykazano, że pomiar ten można wykonać nawet miernikiem wielkoprądowym wymuszającym prąd o wartości...
-
Problemy pomiaru impedancji pętli zwarciowej w nowoczesnych instalacjach niskiego napięcia
PublikacjaRozdział dotyczy pomiarów w sieciach i instalacjach elektroenergetycznych. Podjęto w nim temat zbędnego wyzwalania wyłączników różnicowoprądowych podczas pomiaru impedancji pętli zwarciowej, który jest jednym z elementów sprawdzania odbiorczego oraz sprawdzania okresowego tych instalacji. Omówiono również specyfikę tego pomiaru w obwodach zasilanych z UPS.
-
Badanie wykonalności pomiaru impedancji pętli zwarciowej bez wyzwalania wyłączników różnicowoprądowych
PublikacjaRozprawa doktorska dotyczy rozwiązania problemu, jakim jest wyzwalanie wyłączników różnicowoprądowych podczas pomiaru impedancji (rezystancji) pętli zwarciowej w obwodach, które są przez te wyłączniki chronione. Pomiar impedancji pętli zwarciowej metodą tradycyjną wykorzystującą sztuczne zwarcie, szczegółowo opisaną w normie PN HD 60364 6:2008, jest skuteczny jedynie w obwodach, które nie są chronione wyłącznikami różnicowoprądowymi....
-
Simultaneous impedance and volumetric studies and additionally potentiodynamic polarization measurements of molasses as a carbon steel corrosion inhibitor in 1M hydrochloric acid solution
PublikacjaThe inhibition effect of molasses on the corrosion of low carbon steel in 1M hydrochloric acid solution was investigated by volumetric and electrochemical measurements. Potentiodynamic polarization and dynamic electrochemical impedance spectroscopy (DEIS) results were obtained and compared with to those, obtained with the hydrogen evolution technique. All results indicate that molasses functioned as a good inhibitor in 1M hydrochloric...
-
Atomic force microscopy based approach to local impedance measurements of grain interiors and grain boundaries of sensitized AISI 304 stainless steel
Publikacja -
In-situ odd random phase electrochemical impedance spectroscopy study on the electropolymerization of pyrrole on iron in the presence of sodium salicylate – The influence of the monomer concentration
PublikacjaIn this work, the potentiostatic electropolymerization of polypyrrole (PPy) on iron in aqueous solution of sodium salicylate and pyrrole is studied in situ by odd random phase electrochemical impedance spectroscopy (ORP-EIS). The influence of the pyrrole concentration on the electrosynthesis process is investigated. The ORP-EIS technique ensures a reliable analysis of the PPy electrosynthesis on iron by means of an advanced data...
-
Biomolecular influenza virus detection based on the electrochemical impedance spectroscopy using the nanocrystalline boron-doped diamond electrodes with covalently bound antibodies
PublikacjaNew rapid pathogen detection methods with improved cost-effectiveness and efficiency are currently in the focus of the scientists from all over the world. Based on the experiences from the rapid spread of the influenza virus pandemic in 2009 it is clear that the development of the system for early diagnosis of this infection is essential. The crucial stage of the treatment is the detection of the viral infection during its initial...
-
Atomic force microscopy based approach to local impedance measurements of grain interiors and grain boundaries of sensitized AISI 304 stanless steel
PublikacjaPraca prezentuje wyniki badań uzyskane z pomiarów techniką lokalnej spektroskopii impedancyjnej (LIS) wykonanych w trybie kontaktowym mikroskopii sił atomowych (AFM), które zostały przeprowadzone w lokalnych obszarach powierzchni ziarna austenitu i na granicy ziarna austenitu wysokostopowej stali austenitycznej AISI 304 poddanej procesowi uczulania oraz na próbkach odniesienia nie poddanych obróbce cieplnej.Badania LIS-AFM były...
-
Transient States during Short-circuit in a Line Powered by UPS and its Impact on Earth Fault Loop Impedance Measurement and Power Quality
PublikacjaThe short-circuit in a line powered by Uninterruptible Power Supply (UPS) during different UPS operation modes is presented in the article. The transient state condition related to the short-circuit in a line fed from double conversion On-line UPS is discussed in detail. The results of the measurements of earth fault loop impedance (FLI) in circuits powered by UPS with the instruments of various manufacturers are presented. The...
-
Power Electronic Transformer For Smart Grid Application
PublikacjaIn this paper the control system of Power Electronic Transformer (PET) for the Smart Grid application is proposed. The structure of PET is based on two Cascaded H-bridge (CHB) converters. The electrical energy is transferred between converters using Dual-Active-Bridges (DAB) and high-frequency transformers. This type of coupling has been used to connect the DC-links of all H-bridges. The proposed control system for PET makes it...
-
Feasibility study of inductor coupling in three-level neutral-point-clamped quasi-Z-source DC/AC converter
Publikacja