ISSN:
eISSN:
Publisher:
Disciplines
(Field of Science):
- biomedical engineering (Engineering and Technology)
- chemical engineering (Engineering and Technology)
- civil engineering, geodesy and transport (Engineering and Technology)
- materials engineering (Engineering and Technology)
- mechanical engineering (Engineering and Technology)
- pharmacology and pharmacy (Medical and Health Sciences )
- chemical sciences (Natural sciences)
(Field of Science)
Ministry points: Help
Year | Points | List |
---|---|---|
Year 2024 | 40 | Ministry scored journals list 2024 |
Year | Points | List |
---|---|---|
2024 | 40 | Ministry scored journals list 2024 |
2023 | 70 | Ministry Scored Journals List |
2022 | 40 | Ministry Scored Journals List 2019-2022 |
2021 | 40 | Ministry Scored Journals List 2019-2022 |
2020 | 40 | Ministry Scored Journals List 2019-2022 |
2019 | 40 | Ministry Scored Journals List 2019-2022 |
2018 | 11 | B |
2017 | 11 | B |
2016 | 11 | B |
2015 | 11 | B |
2014 | 9 | B |
2013 | 9 | B |
2012 | 6 | B |
2011 | 6 | B |
2010 | 6 | B |
Model:
Impact Factor:
Publishing policy:
- License
- open in new tab
- Information on publishing policy
- https://content.sciendo.com/view/journals/adms/adms-overview.xml open in new tab
- Information on the conditions of self-archiving
- Included in license
- Is self-archiving allowed by the journal?
- Yes - with restrictions
- Information on research data policy
- n/a
- Months of embargo
- no embargo
- Additional information
-
Must link to journal homepage with DOI.
Self-archiving policy for article versions based on the Sherpa Romeo database.
Papers published in journal
Filters
total: 135
Catalog Journals
Year 2002
-
Relationship between cavitation resistance of laser produced alloys and their ability to work hardening
PublicationBadano odporność kawitacyjną laserowo wytworzonych stopów na stalach konstrukcyjnych i ich związek ze zdolnością do umacniania się pod wpływem działania obciążeń kawitacyjnych. Wykazano, że mikrotwardość powierzchni wykazuje monotoniczną zależność z odpornością kawitacyjną i zdolnością do umacniania.
-
Influence of retrogression and reaging (RRA) heat treatment on microstructure, mechanical and chemical behaviour of an Al-Zn-Mg alloy
PublicationBadano metodą stałego wolnego rozciągania w wodzie morskiej wpływ czasu i temperatury nawrotu oraz powtórnego starzenia na czas do zniszczenia, energię zniszczenia, przewężenie i odkształcenie. Stwierdzono ogólnie niewielki wpływ, przy czym wzrostowi odporności na korozję naprężeniową towarzyszył spadek właściwości mechanicznych. Obserwowane zmiany właściwości przypisano zmianom struktury dyslokacyjnej i mikrostruktury.
-
Hydrogen-enhanced stress corrosion cracking in low alloy steels in seawater
PublicationBadano podatność stali niskostopowych w wodzie morskiej w warunkach polaryzacji katodowej. Stwierdzono spadek czasu do zniszczenia, energii zniszczenia i przewężenia ze wzrostem potencjału katodowego. Wykazano znaczącą korelację między stopniem degradacji wodorowej a stężeniem wodoru dyfuzyjnego.
-
Dependence of cavitation performance of superficial iron alloys on the sub-strate
PublicationWykazano zależność odporności kawitacyjnej laserowo wytworzonych i elektrodąotuloną napawanych powłok od rodzaju podłoża. Napoiny wykonywano na stali 45, 2H13, 0H18N9 i na żelazie Armco.
Year 2003
-
Post-impact moisture absorption in hybrid glass, aramid, carbon/epoxy composites
PublicationZbadano chłonność wody i własności po udarze i absorpcji wody w laminatach hybrydowych aramidowo-szklano-węglowych. Badania porównawcze dla laminatów szklano-epoksydowych wykazały 18% i 33% spadek wytrzymałości na ściskanie odpowiednio w wyniku udaru o energii 10J oraz udaru i absorpcji wody.
-
Microstructure and wear of cast aluminium alloy with laser modified surface layer
Publicationprzedstawiono wyniki badań zużycia przez tarcie przetopionego laserowo stopuAlSi13MgCuNi w warunkach tribologicznych. Wykazano, iż zużycie i współczyn-nik tarcia są zależne od parametrów obróbki laserowej w warunkach kriogeni-cznych.
-
Methods for the characterizing hydrogen degradation of materials
PublicationDokonano przeglądu różnych metod szacowania podatności na niszczenie wodorowe materiałów metalowych. Zaprezentowano charakterystyki warunków środowiskowych: standardowe składy środowisk ciekłych i gazowych, temperatury, warunki polaryzacji elektrochemicznej. Omówiono metody mechaniczne szacowania niszczenia wodorowego różniące się stanem naprężeń, w tym badania: przy stałym obciążeniu, stałym odkształceniu i stałej niskiej szybkości...
-
Laser surface treatment of aluminium-silicon alloy at cryogenic conditions
PublicationW artykule przedstawiono wpływ laserowego, powierzchniowego przetapiania w warunkach kriogenicznych na mikrostrukturę, mikrotwardość, zużycie na skutek tarcia oraz korozję stopu aluminium AlSi13Mg1CuNi. Stwierdzono zwiększenie mikrotwardości, odporności na ścieranie i korozję odlewniczego stopu AlSi13Mg1CuNi stosowanego w produkcji tłoków silników spalinowych.
-
Hydrogen-enhanced stress corrosion cracking and corrosion fatigue of HSLA steels in sea-water
PublicationPrzedstawiono ocenę podatności stali o wysokiej wytrzymałości na naprężeniowe pękanie korozyjne i zmęczenie korozyjne wspomagane przez wodór. Wykonano próby powolnego rozciągania i zmęczenia niskoczęstotliwościowego na stalach 17HMBVA i 14HNMBCu oraz ich złączach spawanych, w środowisku wody morskiej, przy polaryzacji katodowej. Zamieszczono wyniki badań elektrochemicznych oraz przełomów na skaningowym mikroskopie elektronowym.
-
Cavitation erosion of heterogeneous thin coatings produced by means of laser cladding
PublicationPrzedstawiono badania odporności kawitacyjnej cienkich heterogenicznych warstw nakładanych metodami laserowymi na stal 45. Wykazano dobrą przyczepność i wysoką odporność kawitacyjną wykonanych powłok.
-
Advanced vanadium modified steels for high pressure hydrogen reactors
PublicationPrzedstawiono nową generację stali chromowo-molibdenowych zmodyfikowanych wanadem, przeznaczonych do budowy wodorowych reaktorów i porównano ze stalami konwencjonalnymi. Opisano mikrostrukturę, właściwości i zastosowanie stali. Podkreślono wpływ mikrostruktury nowych stali na przebieg degradacji środowiskowej.
Year 2006
-
Numerical modelling of asymetric double-layer Al-Cu plate rolling process
PublicationNiekorzystnym zjawiskiem towarzyszącym procesom walcowania płaskich wyrobów bimetalowych jest krzywizna pasma na wyjściu z kotliny walcowniczej wynikająca z nierównomierności odkształcenia warstw bimetalowej blachy. Możliwość szybkiego i łatwego przeciwdziałania temu zjawisku daje wprowadzenie asymetrii prędkości bądź średnic walców roboczych. W przedstawionym artykule zaprezentowano badania komputerowe procesu walcowania blach...
-
Low velocity impact damage in glass/polyester composite sandwich panels
PublicationZbadano odporność udarową konstrukcji przekładkowych z laminatu poliestrowo szklanego pod kątem adhezji z rdzeniem (pianki PVC) przy polaczeniu dwoma rodzajami kleju lub łączanymi na ''mokro'' przy pomocy żywicy w trakcie utwardzania laminatu. Do oceny obszaru zniszczeń udarowych zastosowano metodę ultradźwiękową, która umożliwia wykrycie pola delaminacji nakładających się na siebie w poszczególnych warstwach .Obszary zniszczeń...
-
Influence of sulphur on high temperature degradation of steel structures in the refinery industry
PublicationArtykuł stanowi przegląd skutków wpływu związków siarki, znajdujących się w mediach procesowych instalacji rafineryjnych, na elementy konstrukcji ze stali węglowych i stopowych. Wyróżniono dwa aspekty wysokotemperaturowej korozji siarkowej: związany z tworzeniem się zgorzeliny siarczkowej i ubytkami masy oraz dotyczący wewnętrznej degradacji elementu w wyniku zmian mikrostruktury stali. Przedstawiono tzw. zmodyfikowane krzywe McConomy...
-
Estimation of cavitation erosion resistance of materials
PublicationW pracy przedstawiono ocenę odporności kawitacyjnej 17 materiałów. Do opisu odporności kawitacyjnej zaproponowano nowy wskaźnik liczbowy uwzględniający długość okresu inkubacji, maksymalną prędkość niszczenia oraz czas po którym wystąpi maksymalna prędkość niszczenia materiału. Zaproponowany wskaźnik porównano ze wskaźnikiem δcav, który reprezentuje całą krzywą erozji kawitacyjnej materiału.
-
Environmental degradation of the Cr-Mo steels in liquid hydrocarbons
PublicationPrzedstawiono podatność stali stopwych 26H2MF i 34HNM do naprężeniowego pękania korozyjnego. Środowiskiem do badań było paliwo ciężkie i zużyty olej mineralny.
Year 2007
-
The use of nitriding as a prevention method against hydrogen degradation of high-strength steels
PublicationPrzedstawiono badania wpływu warstw azotowanych jarzeniowo na stali 34CrAlNi7-10 na jej podatność na niszczenie wodorowe. Wytworzono warstwy azotowane w atmosferach technologicznych o różnym udziale wodoru. Próbki materiału rodzimego i z warstwami azotowanymi poddano próbie rozciągania z małą prędkością odkształcania w środowisku 0,01 N kwasu siarkowego przy polaryzcaji katodowej. Względny spadek plastyczności i charakter przełomu...
-
New laser-enhanced surface treatment of Ti bioalloy
PublicationPrzedstawiono wyniki badan mikrostruktury i korozji w roztworze Ringera stopu Ti6Al4V, który był poddawany nadtapianiu laserem CO2 w powietrzu, wodzie i ciekłym azocie. Stwierdzono znaczący wpływ warunków obróbki na mikrostrukturę, mikrotwardość i głębokość zmodyfikowanej warstwy wierzchniej.
-
Microstructural aspects of corrosion of the SUPERSTON alloy after laser treatment
PublicationW artykule przedstawiono rezultaty obróbki laserowej stopu SUPERSTON w warunkach kriogenicznych i jej wpływ na mikrostrukturę i odporność korozyjną. Badania korozyjne zostały zrealizowane metodą potencjostatyczną w 3% NaCl, odporność korozyjna stopu zmieniała się wraz ze zmianą parametrów nadtapiania laserowego.
-
Influence of the heat treatment on corrosion characteristics of the Superston alloy
PublicationW artykule przedstawiono wpływ hartowania i odpuszczania na twardość i właściwości korozyjne stopu Superston, stosowanego na śruby okrętowe. Stwierdzono, iż hartowanie z temperatury 900 st.C i odpuszczanie w temperaturze 550 st.C znacząco podwyższa odporność na korozję stopu Superston w 3% roztworze NaCl w porownaniu ze stanem odlanym.
-
Influence of H2S on degradation of 9Cr-1Mo steel in advanced stage of metal dusting process
PublicationPrzedstawiono wyniki badań stali 9Cr-1Mo w zaawansowanym stadium procesu pylenia metalu po 10 latach eksploatacji w piecu rafineryjnej instalacji platformingu CCR, przeprowadzonych w celu podjęcia decyzji o dozowaniu związków siarki do wsadu instalacji. Na podstawie długotrwałej ekspozycji próbek stali w 600C w mieszaninie wodoru i siarkowodoru wykazano, że siarka może być powodem procesów wpływających niekorzystnie na stan materiału...
-
Hydrogen permeation through welded joints of S690QL steels at cathodic polarisation in sea water in the presence of SRB
PublicationPrezentowane są wyniki badan metodą Devanathana- Stachurskyego przenikania wodoru w wodzie morskiej w obecności bakterii redukujących siarczany i w warunkach sterylnych. Badania wykonano na stali S690QL poddanej symulowanym obróbkom cieplnym prowadzącym do struktur modelujących strefy wpływu ciepła. Stwierdzono dodatni wpływ obecności bakterii na przenikanie wodoru. Różnice między poszczególnymi próbkami były minimalne.
-
Hydrogen degradation of high strength weldable steels
PublicationW pracy przedstawiono wyniki badań podatności stali spawalnych o wysokiej wytrzymałości na niszczenie wodorowe. Badano dwa gatunki stali S690Q i ich złącza spawane. Ocenę podatności na niszczenie wodorowe wykonano w oparciu o próbę rozciągania z małą prędkością odkształcania w powietrzu i środowisku wody morskiej przy polaryzacji katodowej. Przedstawiono model niszczenia wodorowego badanych stali i ich złączy spawanych.
-
High temperature corrosion of the cobalt base clad layers
PublicationNapawane warstwy wykonane ze stopu kobaltu poddano utlenianiu w temperaturach 650 stopni C i 750 stopni C oraz korozji w spalinach. Proces utleniania był prowadzony 2 sposobami, izotermicznie przez 100 godzin i cyklicznie pzez 200 godzin. Korozja w spalinach przebiegała cyklicznie przez 200 godzin w temperaturze 650stopni C. Warstwy napawano metodą laserową i plazmową (PTA). Badano stabilność termiczną procesu utleniania warstw...
-
High temperature corrosion of evaporator tubes in low-emission steam boilers
PublicationW artykule opisano zjawisko korozji wysokotemperaturowej rur ekranowych kotłów parowych niskoemisyjnych. Przeprowadzono badania rur po eksploatacji. Wykonano badania składu chemicznego zgorzelin. Stwierdzono, że główną przyczyną pocienienia rur na wyższych poziomach jest korozja siarkowa, natomiast na poziomach niższych oddziaływanie stopionych soli.
-
Hardness measurements for assessment of cavitation intensity
PublicationArtykuł opisuje możliwość zastosowania pomiarów teardości erodowanego materiału do oceny natężenia zjawiska kawitacji. Proponowana metoda zakłada, że cała energia implodujących pęcherzyków kawitacyjnych zamieniana jest na przyrost twardości warstwy wierzchniej materiału
-
Environmental failure of dental biomaterials
PublicationW pracy przedstawiono problematykę związaną z zagadnieniem trwałości biomateriałów stomatologicznych. Scharakteryzowano kryteria doboru materiałów i na przykładzie koron stomatologicznych pokazano wyniki oceny prawidłowości doboru w oparciu o metodę elementów skończonych. Przedstawiono wyniki weryfikacji doświadczalnej i wskazano na możliwości wykorzystania tej metody do konstruowania odpornych na zniszczenie koron metalowo-ceramicznych.
-
Environmental degradation of titanium biomaterials: mechanisms, effects, testing and evaluation
PublicationPrzedyskutowano możliwe przyczyny oraz mechanizmy degradacji biomateriałów tytanowych, używanych jako długoterminowe implanty stawów. Dokonano przeglądu wpływu impalntów metalicznych w ludzkim ciele. Przedstawiono bieżące procedury badania oraz ich wady. Zaproponowano procedurę oszacowania biomateriałów na implanty.
-
Corrosion resistance of dissimilar austenite and duplex steels welded joints
PublicationW artykule przedstawiono wpływ warunków spawania, a zwłaszcza energii liniowej, na odporność korozyjną złączy różnoimiennych stali austenitycznej 316L i typu duplex 2203. Przedstawiono wyniki testów korozyjnych:korozji wżerowej wg ASTM G48 oraz korozji naprężeniowej badanej w próbach odkształcania z małą pędkością w środowisku roztworu chlorku magnezowego.
-
Corrosion and hydrogen intake for some Cr-Mn steels in liquid hydrocarbons
PublicationStal 34HNM i 26H2MF, poddana różnym obróbkom cieplnym wykazała skłonność do korozji naprężeniowej przy pomiarach ze stałą szybkością rozciągania (10-6s-1) i pomiarach niskocyklowego zmęczenia, wykonanych w paliwie kotłowym. Mechanizm korozji naprężeniowej określono jako kruchość wodorowa, co zostało potwierdzone w pomiarach pochłaniania wodoru z tych środowisk. Jako możliwe źródła wnikania wodoru do stali omówiono procesy korozyjne,...
Year 2008
-
Wpływ utleniania w wysokich temperaturach na struktury napawanych warstw na bazie kobaltu
PublicationPrzedmiotem badań są napawane plazmowo warstwy wykonane ze stopu kobaltu zawierające ok. 29% chromu, ok. 5% wolframu i ok. 2% niklu, nałożone powierzchnie przylgni grzybków zaworów wylotowych silnika dieslowskiego. Powierzchnia podlega zarówno oddziaływaniom temperatury i środowiska, jak i oddziaływaniom mechanicznym. Podczas badań warstwy poddano oddziaływaniu środowiska utleniającego i wysokich temperatur: 750°C- górna w normalnej...
-
Underwater welding - a review
PublicationW artykule przedstawiono stan obecny oraz perspektywy rozwoju technik spawania pod wodą. Przeanalizowano najważniejsze problemy spawania w środowisku wodnym. Przedstawiono najważniejsze kierunki badań spawania podwodnego podejmowane w Katedrze Technologii Materiałów Maszynowych i Spawalnictwa Politechniki Gdańskiej
-
The degradation of metal implants
PublicationThe presence of metal implants in the human body causes some dangers, which result from introducing another object into organism. There may occur a biocorrosion, which causes different modifications of implant surface.
-
Surface cracking of laser melted Ti-6Al-4V alloy
PublicationOpisano charakterystyczne cechy pękania powierzchniowego obserwowanego po nadtapianiu laserem CO2 i Nd:YAG stopu Ti-6Al-4V. Obserwowano pęknięcia niezależnie od sposobu nadtapiania, penetrujące głęboko strefę przetopioną i w niewielkim stopniu zależne od sposobu nadtapiania. Przypisano obserwowane zjawisko przemianie martenzytycznej i (lub) naprężeniom cieplnym powstającym podczas gwałtownego chłodzenia.
-
Stabilization of the titanium vibration damping wires in the steam turbine blades system
PublicationPrzedstawiono metody stabilizacji drutów tłumiących w systemie łopatkowym turbin parowych. Na podstawie badań eksperymentalnych mikrostruktury i własności mechanicznych wykazano przydatność metody stabilizacji na gorąco drutów tłumiących wykonywanych ze stopu tytanu WT3-1.
-
Spawanie elektronowe i spawanie TIG blach z tytanu technicznego
PublicationW artykule przedstawiono badania metalograficzne, próby rozciągania i pomiary twardości złączy spawanych z tytanu technicznego Grade2. Złącza spawane zostały wykonane za pomoca spawania elektronowego i za pomoca spawania TIG.
-
Review of titanium and steel welding methods
PublicationThe paper presents review of methods of titanium and steel welding. On basis of professional literature it was stated that titanium can be joined with steel by means of explosive welding or brazing.Joining titanium with steel by TIG welding and friction welding methods is possible with the use of copper and tantalum or vanadium interlayer.
-
Pure silicon recovering from photovoltaic modules
PublicationOdzyskiwanie krzemu ze zużytych lub uszkodzonych modułów fotowoltaicznych może mieć znaczenie nie tylko ekonomiczne, ale również ekologiczne. Etap obejmujący procesy chemiczne wymaga optymalizacji z punktu widzenia wymaganej czystości odzyskiwanego krzemu. W pracy przedstawiono wyniki przeprowadzonych prób trawienia poszczególnych warstw ogniw PV: warstwy antyodblaskowej, metalizacji (kontaktów), złącza p-n. Skład roztworów trawiących...
-
Ocena wpływu parametrów nadtapiania laserowego w warunkach kriogenicznych na strukturę warstwy wierzchniej na stopie Ti-6Al-4V
PublicationW pracy zostały przedstawione efekty przetapiania laserowego w warunkach kriogenicznych stopu tytanu Ti-6Al-4V. W celu określenia wpływu obróbki laserowej wykonano analizę mikrostruktury (SEM), składu fazowego (XRD), oraz pomiary mikrotwardości uzyskanych warstw. Stwierdzono, że zmiany podstawowych parametrów przetapiania laserowego - mocy wiązki lasera i prędkości skanowania istotnie wpływają na grubość i mikrostrukturę otrzymanych...
-
Microstructure and corrosion properties of the (Mn-N-O-P) type layers created on aluminium alloys
PublicationPrzedstawiono mikrostrukturę i właściwości korozyjne warstw powierzchniowych typu (Mn-N-O-P) wytworzonych na stopach aluminium. Wykazano, iż warstwy (Mn-N-O-P) podwyższają wielokrotnie odporność korozyjną stopów aluminium i mogą być stosowane jako warstwy ochronne na tych materiałach.
-
Microbiological corossion of metallic products as a result of biofilm
PublicationWarunkiem do pojawienia się korozji mikrobiologicznej jest utworzenie na powierzchni metalu biofilmu. Zawiera on biologicznie czynne mikroorganizmy wraz z produktami ich przemian metabolicznych. Biofilm ogranicza dyfuzję produktów metabolizmu wytwarzanych przez poszczególne komórki mikrokolonii. Powoduje to, że produkty uboczne tych przemian gromadzą się w bezpośrednim sąsiedztwie metalu. Gdy powierzchnia metalu nie jest odporna...
-
FEM approach to estimate the behaviour of biocomposite metal-surface coating system
PublicationA three dimensional (3D) model of biocomposite metal-surface coating system, which is influenced byknown external forces, is proposed. This model consists of the metallic substrate (Ti6Al4V) and thehydroxyapatite (HA) coating. Using FEM (finite element method), strain-stress maps of model weregenerated for investigating relations between the extreme stress of HA coating and the magnitude ofexternal force and the thickness of the...
-
Effects of the time and temperature on the oxide scale formed on the cobalt alloys
PublicationWarstwy wykonane za pomocą techniki PTA ze stopu kobaltu poddano utlenianiu w różnych temperaturach i w różnym czasie. Mikrostruktury otrzymane po utlenianiu wskazują na proces degradacji materiału. Proces ten prowadził do degradacji obszarów międzydendrytycznych napoiny. Skład chemiczny powstającej zgorzeliny byłzależny od temperatury utleniania, składu chemicznego stopu, ze szczegfólnym uwzględnieniem obecności małych ilości...
-
Coatings in arthroplasty [online]
PublicationThe modern coatings used in arthroplasty for long term implants are reviewed. The phosphate coatingsare the most popular technique to improve the bone-implant interfacial strength and promote theosseointegration. The plasma spraying, electrophoretic precipitation, powder metallurgy, ion beamsputtering, high velocity oxy-fuel (HVOF) combustion spraying, sol-gel technique, biomimeticdeposition are mostly used to obtain the phosphate,...
-
Cavitation erosion of X5CrNi18-10 austenitic stainless steel alloyed with TiC
PublicationPraca prezentuje zmianę odporności kawitacyjnej stali X5CrNi18-10 po laserowym stopowaniu jej warstwy wierzchniej węglikiem TiC. Laserowe stopowanie przeprowadzono dla 2 wariantów. W pierwszym przypadku stal stopowano do zawartości 1,55 TiC a w drugim do zawartości 3,97% TiC. Uzyskane rezultaty wskazują że przy zawartości 3,97 TiC nastopiło znaczące zwiększenie odporności na plastyczne odkszyałcenie warstwy wierzchniej pod wpływem...
-
Assessment of evaporator tubes corrosion in low-emission steam boilers
PublicationW artykule przedstawiono wyniki badań rur ekranowych(16Mo3) kotła niskoemisyjnego po jednym roku i dwóch latach eksploatacji. Powierzchnie rur pokryte zostały warstwami natryskiwanymi cieplne - pojedynczą ze stopu 70%Ni 30%Cr i podwójną Ni-30Cr /Al2O3. Rury bez powłok natryskiwanych wykazywały pocienienie ze względu na działanie korozji siarkowej oraz korozyjnego oddziaływania warstwy stopionych soli. Pojedyncza warstwa 70%Ni 30%Cr...
-
Assessment of cavitation erosion damage of laser remelted the SUPERSTON alloy
PublicationW artykule przedstawiono wpływ obróbki laserowej w warunkach kriogenicznych na mikrostrukturę stopu SUPERSTON po badaniach kawitacyjnych. Badania odporności kawitacyjnej przeprowadzono na stanowisku z wirującą tarczą w IMP PAN Gdańsk. Określono kinetykę ubytku masy próbek podczas testu kawitacyjnego dla stopu odlanego i nadtopionego laserowo.
-
Analisys of the failure of fixator used in bone surgery
PublicationThe Gamma nail (fixator) made of stainless steel, which has broken in the body, was subjected to examination. The fixator was removed from the patient femur. The fracture occurred in the area of the nail hole after two months' stay in the organism. The research included chemical composition, hardness of the Gamma nail material and the observation and analysis of the type of fracture. The research showed the fatigue failure of the...
Year 2009
-
Underwater welded joint properties investigation
PublicationPrzeprowadzono badania mikro- i makroskopowe złączy spawanych typu implant wykonanych pod wodą metodą lokalnej komory suchej. Wyniki badań świadczą o tym, że w SWC badanych złączy tworzą się kruche struktury hartownicze, które są odpowiedzialne za zwiększoną skłonność stali o podwyższonej wytrzymałości do tworzenia pęknieć zimnych. Analiza rozkładów twardości złączy implant również potwierdza istnienie szkodliwego wpływu środowiska...
-
Self-Organized Nanotubular Oxide Layers on Ti and Ti Alloys
PublicationTo improve bioactivity of titanium and titanium, the implant surface modification by formation of self-organized TiO2 nanotube arrays with electrochemical techniques is presented. The influence of electrolyte composition and deposition parameters during anodization is characterized. The enhancement of phosphates deposition by titanium nanotubular structure is discussed. The calcium phosphate ceramics is shown to be uniformly deposited...
-
Porous materials used as inserted bone implants
PublicationArtykul zawiera przegladowa analize literatury dotyczaca scaffoldow
-
Optoelectronic system for investigation of cvd diamond/DLC layers growth
PublicationDevelopment of the optoelectronic system for non-invasive monitoring of diamond/DLC (Diamond-Like-Carbon) thin films growth during μPA ECR CVD (Microwave Plasma Assisted Electron Cyclotron Resonance Chemical Vapour Deposition) process is described. The system uses multi-point Optical Emission Spectroscopy (OES) and long-working-distance Raman spectroscopy. Dissociation of H2 molecules, excitation and ionization of hydrogen atoms...
-
Microstructure and properties of the cobalt base clad layers after long time service
PublicationBadaniu poddano napawane laserowo warstwy ze stopu na bazie kobaltu. Warstwy wykonane na przylgni grzybka zaworu wylotowego silnika diesla badano po dwóch latach eksploatacji w dwóch silnikach laboratoryjnych. Badania mikrostruktury nie wykazały znaczących zmian. Przeprowadzono również badania chemiczne oraz pomiary twardości warstw po eksploatacji. Badany typ napoin nie wykazał znaczących uszkodzeń po długim czasie eksploatacji.
-
Influence of laser remelting at cryogenic conditions on corrosion resistance of non-ferrous alloys
PublicationCelem nadtapiania laserowego elementów wytwarzanych z stopów aluminium, miedzi i tytanu jest uzyskanie wysokiej twadrości i odporności na korozję dla wydłużenia okresu ich eksploatacji w rezultacie ich szybkiej krystalizacji. Końcowa mikrostruktura, skład fazowy i właściwości wymienionych stopów zależą od parametrów obróbki laserowej oraz budowy wykresów równowagi fazowej. W artykule przedstawiono wpływ laserowego nadtapiania...
-
Fracture of aluminium joints bonded with epoxy adhesive reinforced by mmt nanoparticles
PublicationCrack propagation behavior was studied for aluminium/aluminum adhesive joints bonded with two epoxy adhesives: pure and reinforced with clay nanoparticles. The focus was also on the novel use of the constant displacement rate test to study adhesion/adhesives efficiency. The epoxy systems studied were: Epidian E6 produced from bisphenol A and epichlorohydrin, (''Organika -Sarzyna'' Poland); pure or strengthened with montmorillonit...
-
Effect of chemical composition and microstructure on mechanical properties of BA1055 bronze sand castings.
PublicationW pracy wykazano, że nawet małe zmiany w składzie chemicznym brązu aluminiowego BA1055 mają istotny wpływ na strukturę i właściwości mechaniczne odlewów. Określono wpływ wydzieleń międzymetalicznej fazy κ na właściwości odlewów z brązu BA1055 stosowanego na pędniki okrętowe.
-
Chemical characteristics of new nanopowder of titania doped with nitrogen atoms
PublicationW pracy zaprezentowano charakterystykę domieszkowanego azotem ditlenku tytanu otrzymanego na drodze jednoetapowej syntezy z kompleksu tytanu (IV) z ligandami zawierającymi atomy azotu. ikrostruktura i morfologia nowego materiału została określony za pomocą badań XRD, AFM, UV-VIS i FT-IR. Raport przedstawia również badania elektrochemiczne, które pozowliły na wyznaczenie potencjału pasma płaskiego na podstawie wykresu Mott
-
Allergy to implant components: chromium, nickiel, cobalt and titanium
PublicationImplant jest kompozycja roznych pierwiastkow: niklu, chromu, kobaltu, tytanu, molibdenu i wanadu. Pierwiastki te moga doprowadzic do alergii, egzemy i obluzowania implantu.
Year 2010
-
Surface modifications of ti and its alloys
PublicationThis article reviews the various surface modification techniques pertaining to titanium and titanium alloys including physical treatment, mechanical treatment, and chemical and electrochemical treatment. The proper surface modification expands the use of titanium and its alloys in the biomedical field for long-term implants retaining the excellent properties of substrate material and improving the specific surface properties required...
-
Reliable method of assessing fracture properties of asymmetric bonded joints
PublicationTwo methods of assessing fracture properties of adhesive joints were studied. Two wedge tests: with continuous deflection and with force measurements were compared. Asymmetric geometry of the bonded joint was considered, i.e. two different plates of aluminium alloys: Al-Cu and Al-Mg, were bonded with epoxy DGEBA adhesive. The analytical model is shown to estimate the values of fracture properties: crack position and critical fracture...
-
Reactions on the surface of the implant under the influence of biofilm
PublicationThe contact of a biomaterial with the biological environment in in vitro and in vivo tests leads to the production of a particular ecosystem in which the active roles perform both, the material surface and the extracellular matrix protein forming a biofilm. Proteins affect cell and bacteria adhesion processes, biological activity of cells and activation of inflammatory response.The knowledge of the reaction mechanisms active on...
-
Properties of surface layers of titanium alloy Ti6Al4V after laser melting processes
PublicationThe article presents the investigation results of titanium alloy Ti6Al4V surface layer after laser melting process. The process of laser melting was performed using Nd-YAG laser. The evaluation of structure of the alloy as well as hardness and chemical composition was performed. It was shown that laser melting changes the structure and properties of titanium alloy Ti6Al4V and process parameters as scanning speed affects the thickness...
-
Preparation of silver nanoparticles in reverse micelles and antibacterial activity of silver modified-paints
PublicationW publikacji została opisana metoda otrzymywania nanocząstek srebra oraz farb modyfikowanych srebrem i ich wpływ na zahamowanie rozwoju wybranych bakterii i grzybów. Podjęto również próbę porównania wpływu rodzaju prekursora srebra oraz substancji powierzchniowo czynnej na stabilność otrzymanych nanocząstek srebra. Przygotowane mikroemulsje zawierały od 500 do 2000 ppm srebra
-
Optimal Features of Porosity of Ti Alloys Considering their Bioactivity and Mechanical Properties
PublicationW artykule przedstawiono wpływ porowatości i rozmiaru porów tytanu i jego stopów, użytych, jako materiały ortopedyczne, na bioaktywność i własności mechaniczne struktur porowatych. Optymalne cechy porowatych rusztowań tytanowych umożliwiają rekonstrukcję i regenerację tkanki kostnej w zastosowaniach przenoszących obciażenie.
-
Hydroxyapatite coatings on porous ti and ti alloys
PublicationDeposition of hydroxyapatite coating on porous Ti and Ti alloys with electrochemical and biomimetic deposition approach is presented. The enhancement of phosphates deposition by well oriented and uniform titanium oxide nanotube array on the surface of titanium substrate is discussed.
-
Fracture Energy of Bonded Joints with 2D Elastic Adhesive Layer
PublicationWhen bonded joint is subjected to mode I fracture loading, the adhesive joints analytical solutions treats the adhesive layer, usually, as not existing or 1D Hooke elastic layer. In the case of 1D elastic layer, represented as Hookes spring element, is acting, only, in direction contrary to the applied load. Basing on the information yielded from sensitive laser profilometry technique, where deflections of bonded part of the joint...
-
Failure analysis of the exhaust valve face in diesel marine engine
PublicationThe exhaust valve from marine diesel engine which was damaged after 2000 hours of service was investigated. In order to prolong the service time the valve face was cladded with cobalt base alloy using laser technique. After failure microstructural and chemical analyses reviled that cladding process was conducted improperly. The chemical composition of the clad layer was far from the designed one and what more completely inhomogeneous....
-
Biocompatibility and Bioactivity of Load-Bearing Metallic Implants
PublicationThe main objective of here presented research is to develop the titanium (Ti) alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behaviour for load-bearing implants, e.g. hip joint and knee joint endoprosthesis. The development of such materials is performed through: modeling the material behaviour in biological environment in long time and developing of new procedures for such evaluation;...
-
Biocompatibility and bioactivity of load-bearing metallic implants
PublicationThe main objective of here presented research is to develop the titanium (Ti) alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behaviour for load-bearing implants, e.g. hip joint and knee joint endoprosthesis. The development of such materials is performed through: modeling the material behaviour in biological environment in long time and developing of new procedures for such evaluation;...
-
Assessment of fitness for service of Cr-Mo steel tubes in catalytic reforming charge heaters
PublicationIn this paper characteristic features of metal dusting corrosion in high temperature gas mixtures of high carbon activity in catalytic reforming units, including Continuous Catalyst Regeneration (CCR) platformer are presented. Examples of 2.25Cr-1Mo and 9Cr-1Mo steel tubes at advanced stages of metal dusting process after long-term service in charge heaters are used to prove that destructive examinations are necessary to provide...
-
Allergic Reactions as a Defense of the Organism to the Influence of Implants Components Made of Stainless Steel
PublicationDue to the increasing number of cases of hypersensitivity caused by direct contact with metals, as well as the increasing demand for implants in humans all ages numerous studies on the effects of the impact of implant components are being carried out. The paper presents the phenomenon of etiology of allergy in general terms and in relation to the biomaterials used in medicine. There have been characterized in terms of impact on...
-
Allergic reactions as a defense of the organism to the influence of implants components made of stainless steel
PublicationDue to the increasing number of cases of hypersensitivity caused by direct contact with metals, as well as the increasing demand for implants in humans all ages numerous studies on the effects of the impact of implant components are being carried out. The paper presents the phenomenon of etiology of allergy in general terms and in relation to the biomaterials used in medicine. There have been characterized in terms of impact on...
-
A Multi Rig Screening Test for Thin Ceramic Coatings in Bio - Tribological Applications
PublicationA method is presented for the comparative testing of wear resistance of ceramic coatings made from materials potentially feasible in tribo - medical applications, mainly orthopaedic implants made from ceramics coated metals for low cost, long life and low wear particle emission into the body. The method was devised as the main tool for use in research and is comprised of flat on flat and ball on flat surface (sliding) tests. Seven...
Year 2011
-
Two tests for adhesive bonding long term characterization: principles and applications
PublicationThis article describes recent refinement of the traditional wedge test technique used to characterize durability of the adhesive joints. We propose two types of measuring protocols to monitor precisely and continuously the propagation of an "effective" crack during long term mode I fracture mechanic test. First method is directly derived from the traditional wedge test technique and consist in monitoring the surface strain of adherent...
-
Resistance to cold cracking of steel joints of P460NL1 steel
PublicationPrzedstawiono wyniki badań odporności na zimne pękanie złączy spawanych ze stali przeznaczonej do pracy pod ciśnieniem. Badano równoczesny wpływ zawartości wodoru dyfundującego i energii liniowej na naprężenie krytyczne w próbie implant dla złączy spawanych elektrodami otulonymi i drutem proszkowym w osłonie gazów ochronnych. Stwierdzono wpływ energii liniowej jak i zawartości wodoru dyfundującego na odporność na zimne pękanie...
-
Porous biomaterial for orthopaedic implants based on titanium alloy
PublicationTytan i jego stopy są szeroko stosowane jako biomateriały dla zastosowań ortopedycznych. Badania związane z ich najlepszą odpornością na korozję i ścieranie, biozgodnością i bioaktywnością są stale prowadzone. Obecne badania koncentrują się również na projektowaniu i produkcji materiałów porowatych w oparciu o stopy np. Ti-13Nb-13Zr, które mogą być stosowane do wytwarzania implantów. Jedną z najbardziej efektywnych metod wytwarzania...
-
On degradation of glass/polyester laminate immersed in water
PublicationMechanical behaviour was compared for glass/ polyester laminates manufactured in the boatbuilding plant using three methods: hand lay-up, vacuum bagging, infusion. Specimens were tested in dry condition and following accelerated water immersion test (70°C- corresponding to the exposure of 30 years at 19°C). In three point bending test 40-50% reduction in laminate strength was observed due to water immersion. The highest degradation...
-
Nanotubular Titanium Oxide Layers for Enhancement of Bone-Implant Bonding and Bioactivity
PublicationThe present paper describes the techniques to improve the bioactivity of titanium and enhance the bone-implant bonding ability by the electrochemical anodization to fabricate titania nanotube arrays (TiO2).
-
Nanotechnologies in Development of Structural Materials and Biomaterials
PublicationThe nanometric materials and technologies resulted in nanostructures are reviewed. The examples of nanomaterials are shown. The typical nanotechnologies, including plastic deformation, mechanical attrition, controlled detonation, hot plasma jet synthesis, laser vaporisation, CVD and PVD, mechanical milling, annealing, ultrasonic irradiation, nanolithography, electrocrystallisation, electrospinning, sol-gel method, cryogenic laser-enhanced...
-
Modeling by finite element methods of impact of erosion on frequency of normal modes of L-0 blade
PublicationAfter some time of exploitation steam turbine rotors blades in energetic industry they are being eroded and also their frequency of normal modes is changed. Those changes can cause to unwanted shift of blades normal mode frequencies. It is necessary to find quick method of rating changes of frequency in connection of mass loss due erosion. The evaluation of this dependence was made by finite element modeling method using HyperWorks...
-
Influence of pore formers on electrical properties of CaTi0.9Fe0.1O3-δ perovskite-type ceramics
PublicationPorous CaTi0.9Fe0.1O3-δ (CTF) perovskites were synthesized by the standard solid state method at different sintering temperatures with carbon black (CB), corn starch (CS) and potato starch (PS) as pore-forming agents. The ceramic samples of porosity between 9% and 42% with 5 - 40 μm pore sizes, were obtained by a 6 h sintering at either 1130º C or 1200º C of precursor powder prepared at 1470º C. X-ray diffraction analysis proved...
-
Corrosion resistance examinations of Ti6Al4V alloy with the use of potentiodynamic method in Ringer`s and artificial saliva solutions
PublicationThe research results of corrosion resistance of the Ti6Al4V alloy in the simulated body fluids (SBF) are presented. The polished specimens have shown better corrosion resistance than grinded surfaces in both liquids. The artificial saliva has revealed more aggressive test solution than Ringer`s solution. The pitting tendency has been observed in Ringer`s solution for grinded specimens.
Year 2012
-
Water sorption and blistering of GFRP laminates with varying structures
PublicationThe microstructures, water absorption as well as blistering was studied for bi- and tri- axial glass fibre vinyl ester and polyester -matrix laminates coated with gel coat layer and uncoated. The effect of manufacturing technique on water sorption characteristics was considered. It was found that water sorption characteristics of GFRP depend on manufacturing methods. The least water intake was found for specimens having perfect...
-
Environmental degradation of titanium alloy in artificial saliva
PublicationThe titanium and its alloys are potentially prone to hydrogen embrittlement, including those proposed for dental implants. The research has been aimed to assess a susceptibility to environment-enhanced degradation of the Ti-13Zr-13Nb alloy in artificial saliva with or without hydrofluoric acid, subject or not to cathodic polarisation. The results have shown that even if artificial saliva is safe environment, both cathodic polarization...
-
Bioactive core material for porous load-bearing implants
PublicationSo far state of knowledge on biodegradable materials is reviewed. Among a variety of investigated materials, those composed of polymers and ceramics may be considered as only candidates for a core material in porous titanium alloy. The collagen and chitosan among natural polymers, polyhydroxy acids among synthetic polymers, and hydroxyapatite and tricalcium phosphate among ceramics are proposed for further research. Three essential...
Year 2013
-
Novel Polyurethanes as Antifouling Paint Matrices
PublicationThe new poly(ester-ether urethane)s (PEEUR) were prepared in two stage synthesis from formerly obtained oligo(alkylene ester-ether)diols (OAEE) and 4,4‘-diphenylmethane diisocyanate (MDI). PEEUR samples were subjected to crosslinking with styrene in the presence of radical polymerization initiators: methyl ethyl ketone peroxide (MEKPO) or cobalt 2-ethyl cyclohexanoate (EtHCo). Crosslinked PEEUR were characterized by their physicochemical...
-
DYNAMIC MECHANICAL BEHAVIOUR OF GFRP COMPOSITES WITH SiO2 NANO PARTICLES REINFORCED EPOXY MATRIX
PublicationDynamic mechanic (DMA) tests were performed to compare the mechanical behaviour of glass fibre reinforced epoxy laminate composites with SiO2 nanoparticle reinforced matrix. The selection of the most promising nanoparticle concentrations was considered in terms of elastic modulus and glass transition temperature. The reference specimens (0% nanoparticles) did not contain diluent accordingly the results do not allow the exact comparison...
-
DEGRADATION OF GFRP MARINE LAMINATES WITH NANO PARTICLE MODIFIED COATINGS
PublicationWater absorption and surface blistering behaviour was studied for polyester-matrix laminates with SiO2 nanoparticle reinforced gel coats. Accelerated water immersion tests at 37°C showed that addition of 10% nanoparticles increases blisters incubation time by ca. 50% compared to 5% and 0% nanoparticles composites.
Year 2014
-
Weldability of S500MC Steel in Underwater Conditions
PublicationWet welding with the use of covered electrodes is one of the methods of underwater welding. This method is the oldest, the most economic and the most versatile. The main difficulties during underwater wet welding are: high cooling rates of the joint, the presence of hydrogen in the arc area and formation of hard martensitic structure in the weld. These phenomena are often accompanied by porosity of welds and large number of spatters,...
-
The Effect of Welding Conditions on Mechanical Properties of Superduplex Stainless Steel Welded Joints
PublicationThe tests results of superduplex stainless steel welded joints made with a different heat input, using automatic submerged arc welding (SAW) and semi-automatic flux-cored arc welding (FCAW) have been presented. Metallographic examinations, the measurements of the ferrite content, the width of the heat affected zone (HAZ) and the hardness of the welds in characteristic areas have been performed. Significant differences in the amount of...
-
THE DETERMINATION OF ABRASION RESISTANCE OF SELECTED BIOMATERIALS FOR THE FRICTION PAIRS IN THE HIP JOINT ENDOPROSTHESIS
PublicationThe key requirement for the modern endoprosthesis is high durability of the friction components, which results in long and trouble-free operation in the human body. The durability of currently used endoprosthesis is often limited by tribological wear processes of friction components (e.g. between the head and the acetabular component in a hip joint endoprosthesis) [8, 19, 23, 24]. In order to compare the tribological wear, tribological...
-
Electrochemical Characterization of Gelatine Derived Ceramics
PublicationNew materials obtained by pyrolysis of gelatine (G) and poly(1,2-dimethylsilazane) (PSN) (weight ratio: G/PSN 70/30) at temperatures 700 and 900 °C were characterized by SEM and Raman spectroscopy. The presence of ceramics influences on the cluster size of the materials. Electrochemical tests were performed by cyclic voltammetry and galvanostatic cyclic polarization. The capacity of G/PSN was 464 and 527 mAh/g for materials pyrolysed...
-
Comparative in vitro research of the Human Aortic Bioprosthesis
PublicationE valuate of the usefulness and reliability of structures based on the analysis of recorded parameters determining the flow through the Human Aortic Bioprosthesis (HAB) have been dealt with. By flow parameters changes determining the performance environment of prosthesis analyzed change of the motion dynamics of the valve leaflets as a function of pressure, thereby determining the degree of alignment of the prosthesis to the performance...
-
BIOMATERIALS AND IMPLANTS IN CARDIAC AND VASCULAR SURGERY - REVIEW
PublicationCurrently, on prosthesis in cardiac blood vessels and heart valves are used materials of animal or synthetic origin. For animal materials include, among others pericardial sac in which is the heart. Materials such as this (natural) are characterized by a remarkable biocompatibility within the human body, but their main disadvantage is the relatively low durability. In turn, synthetic materials, which include the austenitic chromium-nickel-molybdenum...
Year 2015
-
Project of hip joint endoprothesis for an individual patient with materials selection
PublicationThis work includes the hip replacement design, based on the patient's medical records, the description of creation process and materials used for individual components.
-
INFLUENCE OF PRESERVATIVE ON THE TENSILE STRENGTH OF THE TISSUE OF PORCINE CIRCULATORY SYSTEM
PublicationCurrently one of the leading causes of death worldwide is heart diseases which include calcification of heart valves and vascular aneurysm. There are many biomaterials that can substitute pathologically altered tissue, however, none of them is as perfect as native tissue. Currently, scientists are looking for new biomaterials that can be successfully implanted without exposing the patient to reoperation. Each material introduced...
-
Impact Behaviour of Glass Fribre /Epoxy Composites with Nano-Enhanced Resin after Water Exposure
PublicationImpact behaviour of glass fibre /epoxy composites with nano- SiO2 modified resin was studied in terms of low velocity impact after water exposure. Nanocomposites with 1%, 2%, 3% 5% 7% nano-SiO2 (Nanopox- Evonic) were investigated. Peak impact load and impact damage area as a function of nanoparticle contents were compared for dry specimens and for samples exposed to water (0.7 %wt. 1.7% water absorbed) at 1J, 2J 3J impact energies....
-
Fabrication of Composite Polyurethane/Hydroxyapatite Scaffolds Using Solvent-Casting Salt Leaching Technique
PublicationScaffolds are porous three-dimensional structures which are used to fill bone losses and make them possible to cells to grow. Many different structural and biological properties are required from them: porosity, mechanical strength and biocompability. The present research is aimed at development of composite polyurethane/hydroxyapatite scaffolds by using the solvent-casting salt leaching method. The SEM examinations were applied...
-
ESTIMATION OF YOUNG`S MODULUS OF THE POROUS TITANIUM ALLOY WITH THE USE OF FEM PACKAGE
PublicationPorous structures made of metal or biopolymers with a structure similar in shape and mechanical properties to human bone can easily be produced by stereolithographic techniques, e.g. selective laser melting (SLM). Numerical methods, like Finite Element Method (FEM) have great potential in testing new scaffold designs, according to their mechanical properties before manufacturing, i.e. strength or stiffness. An example of such designs...
-
Cold Cracking Of Underwater Wet Welded S355G10+N High Strength Steel
PublicationWater as the welding environment determines some essential problems influencing steel weldability. Underwater welding of high strength steel joints causes increase susceptibility to cold cracking, which is an effect of much faster heat transfer from the weld area and presence of diffusible hydrogen causing increased metal fragility. The paper evaluates the susceptibility to cold cracking of the high strength S355G10+N steel used,...
seen 2193 times