SiC-based T-type modules for multi-pulse inverter with coupled inductors
PublicationThe paper presents SiC-based three-level T-type modules designed for a high-performance 30kVA DC/AC inverter operating at high frequency 85 kHz with low THD of the output voltage. This inverter system consists of two integrated parts. The first part is active and contains three parallelconnected three-phase T-type modules built with fast-switching SiC power transistors. The second, passive part of the system is a set of inductors...
-
The Influence of a Photovoltaic Micro-Installation on the Low-Frequency Parameters of Electricity at PCC and Its Impact on the Thermal Characteristics of Selected Devices
PublicationThis manuscript illustrates the measurement results of parameters describing the quality of energy at the PCC (point of common coupling) of a photovoltaic micro-installation that can significantly affect devices in the same power grid. The analyses reflecting heating of selected devices used in domestic installations, which were performed in an isolated laboratory environment, are also indicated. The conducted study aimed at checking...
-
Porównanie działania transformatora symetryzującego (zygzak) z aktywnym energoelektronicznym symetryzatorem prądów fazowych linii niskiego napięcia
PublicationNa potrzeby planowania sieci niskiego napięcia operatorzy systemów dystrybucyjnych (OSD) zakładają symetryczne warunki obciążenia linii. Z roku na rok, rośnie liczba rozproszonych systemów fotowoltaicznych (PV) zainstalowanych w sieciach niskiego napięcia, których większość to małe jednofazowe systemy dachowe. Dodatkowo, do niesymetrii obciążenia przyczyniają się instalowane masowo pompy ciepła i ładowane jednofazowo samochody...
-
Development of an Advanced Control Algorithm for DAB DC/DC Converters: Inrush Current Limitation and Enhanced Operation in Transient States.
PublicationThe publication addresses the dynamic state challenges encountered during development of a dual active bridge (DAB) converter within DC microgrid systems. The conventional startup method is identified as instigating a cascade of unfavorable outcomes, encompassing elevated starting current, transformer current asymmetry, DC voltage distortions, EMI and heightened thermal stress on semiconductor components. Additionally, it necessitates...
-
Organic Vapor Sensing Mechanisms by Large-Area Graphene Back-Gated Field-Effect Transistors under UV Irradiation
PublicationThe gas sensing properties of graphene back-gated field-effect transistor (GFET) sensors toward acetonitrile, tetrahydrofuran, and chloroform vapors were investigated with the focus on unfolding possible gas detection mechanisms. The FET configuration of the sensor device enabled gate voltage tuning for enhanced measurements of changes in DC electrical characteristics. Electrical measurements were combined with a fluctuation-enhanced...
-
Analysis of electromagnetic disturbances in DC network of grid connected building-integrated photovoltaic system
PublicationThis paper focuses on conducted electromagnetic interference (EMI) emissions and propagation in the DC network of grid connected building integrated photovoltaic (PV) system. The investigated PV system, consists of ten solar panels, cabling and the grid-connected one phase inverter. The EMI simulation model of the real PV system has been developed with the aid of impedance analyzer measurements of solar panels and the DC network...
-
Jednofazowy falownik napięcia z aktywnym obwodem odsprzęgającym
PublicationZnanym zagadnieniem w jednofazowych falownikach napięcia jest pobieranie ze źródła napięcia stałego składowej przemiennej o częstotliwości dwukrotnie większej od częstotliwości generowanej przez falownik. Jednym z rozwiązań problemu jest stosowanie dużej baterii kondensatorów elektrolitycznych, lecz lepszym sposobem z punktu widzenia niezawodności i gęstości mocy przekształtnika jest stosowanie aktywnych układów odsprzęgania mocy....
-
Experimental test results of the 150kVA 18-pulse diode rectifier with series active power filter
PublicationThe paper presents the control system and selected results of experimental tests of the ac/dc power converter consisting of 18-pulse diode rectifier on the basis of coupled reactors and a serial active power filter. Three configurations of the 150kVA converter were tested experimentally and compared: 18-pulse diode rectifier with and without additional grid reactor and the rectifier integrated with the active power filter. The...
-
Low cost set-up for supercapacitors parameters evaluation
PublicationSupercapacitors are capable to store relatively high amount of energy comparing to its mass. Growing number of these devices applications requires development of new testing methods. Standard methods of evaluation of supercapacitor parameters, as cycling voltammetry, CV, galvanostatic cycling with potential limitation, GCPL, impedance measurements, require equipment of high cost...
-
Comparison of Impedance-Source Networks for Two and Multilevel Buck–Boost Inverter Applications
Publicationmpedance-source networks are an increasingly popular solution in power converter applications, especially in single-stage buck-boost power conversion to avoid additional front-end dc-dc power converters. In the survey papers published, no analytical comparisons of different topologies have been described, which makes it difficult to choose the best option. Thus, the aim of this paper is to present a comprehensive analytical comparison...
-
Dynamiczne wyznaczanie parametrów elektrycznego obwodu szeregowego
PublicationPo załączeniu napięcia na skutek istnienia inercji prąd w obwodzie zaczyna narastać od wartości zerowej do znamionowej. W tym czasie narastają spadki napięć na rezystancjach (impedancjach obwodu) do chwili spełnienia prawa Kirchhoffa. Można utworzyć układ ze sprzężeniem zwrotnym (układ regulacji stałowartościowej bądź nadążnej), który poszukuje parametrów obwodu spełniających prawa Kirchhoffa – elementy nie muszą być liniowe. W...
-
Accurate modeling of quasi-resonant inverter fed IM drive
PublicationIn this paper wide-band modeling methodology of a parallel quasi-resonant dc link inverter (PQRDCLI) fed induction machine (IM) is presented. The modeling objective is early-design stage prediction of conductive electromagnetic interference (EMI) emissions of the considered converter fed IM drive system. Operation principles of the selected topology of PQRDCLI feeding IM drive are given. Modeling of the converter drive system is...
-
Comparative analysis of three‐phase dual active bridge converter with different transformer topology and modern universal control for DC microgrids
PublicationThe presented work discusses issues related to the use of modern multiphase topologies of Dual Active Bridge (DAB)-type converters. Converters of this type are widely used in most DC microgrid applications. The introduction emphasizes a comparative analysis between single-phase and multi-phase DAB topologies within high-power DC microgrids, delving into their respective advantages, drawbacks, design procedures, and considerations...
-
Highly stable CsFAPbIBr perovskite solar cells with dominant bulk recombination at real operating temperatures
PublicationMixed-cation mixed-halide perovskite solar cells have been characterized in DC at different temperatures (from −20 °C up to 50 °C) and the time evolution of the device efficiency has been assessed using different degradation protocols (indoors and outdoors). The completely planar p–i–n structure is ITO/CuNiOx/PTAA/CsFAPbIBr/PCBM/PEI/Ag. Pristine current–voltage characteristics barely show hysteresis, at any temperature. Open circuit...
-
Conducted emi identification in power electronic converters : modeling of EMI generation and propagation using circuit simulation and wiener filtering methods.
PublicationThis work presents the circuit simulations and the conventional signal processing technique (Wiener filtering) in order to reconstruct conducted ElectroMagnetic Interferences (EMI), generated and propagated in power electronics converters. In the simulation study, the most accurate presently available models of components of circuit have been used and improved. The proposed Wiener filtering method allows to identifying the transfer...
-
IMPACT OF DIRECT CURRENT ON NITRIFYING BIOMASS
PublicationEffects of short term exposure of nitrifying biomass to direct current were studied. DC was applied to mixed liquor from municipal BNR plant using graphite electrodes in no substrate limiting conditions. Both, ammonia oxidizing bacteria (AOB) and nitrite oxidizing bacteria (NOB) populations were affected by the current, however in opposite ways. The AOB population activity was inhibited by applied voltage. Activity decrease was...
-
Nonlinear and linear impedance of bismuth vanadate ceramics and its relation to structural properties
PublicationThe nonlinear and linear electrical properties, topography, and microstructure of bismuth-vanadate ceramics, were studied. The structurewas observed with the use of X-ray diffraction (XRD), scanning electronmicroscopy (SEM), atomic force microscopy (AFM) and confocal microscopy methods. The obtained results showed that ceramic is porous. Two phase transitionswere determinedwith the use of DSC measurements. The linear and nonlinear ac...
-
BPL-PLC Voice Communication System for the Oil and Mining Industry
PublicationApplication of a high-efficiency voice communication systems based on broadband over power line-power line communication (BPL-PLC) technology in medium voltage networks, including hazardous areas (like the oil and mining industry), as a redundant mean of wired communication (apart from traditional fiber optics and electrical wires) can be beneficial. Due to the possibility of utilizing existing electrical infrastructure, it can...
-
Residual current protective device for circuits of distorted earth fault currents – concept, construction and testing
PublicationThis dissertation presents behavioral and performance verification and analysis of residual current devices (RCDs), as well as a proposal for the construction of a new RCD protection. The state of the art focuses over pre-existing design of the RCD and its behavior and response to the circuits with distorted (non-sinusoidal) earth fault currents. The study highlights the loopholes of the existing design and depicts the problem...
-
New Architecture of Solid-State High-Voltage Pulse Generators
PublicationThe application of the nanosecond pulsed electric field (nsPEF) for biomedical treatments has gained more interest in recent decades due to the development of pulsed power technologies which provides the ability to control the electric field dose applied during tests. In this context, the proposed paper describes a new architecture of solid-state high-voltage pulse generators (SSHVPG) designed to generate fully customised sequences...
-
Collection Efficiency in Narrow Electrostatic Precipitators with a Longitudinal or Transverse Wire Electrode
PublicationRecently narrow electrostatic precipitators (ESPs) have become a subject of interest because of their possible application in diesel engine exhaust systems. In this work, results of particle collection efficiency measurements in narrow electrostatic precipitators for negative and positive dc voltage polarity are presented. The ESP usedin this work was a parallelepiped equipped with wire discharge electrode and two collecting plate-electrodes....
-
Fault Loop Impedance Measurement in Circuits Fed by UPS and Principle of Safety Protection
PublicationThis paper indicates a significant problem of uncertainty of fault loop impedance (FLI) measurement in circuits powered from uninterruptible power supply (UPS) (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers...
-
Metamaterial-Based Sub-Microwave Electromagnetic Field Energy Harvesting System
PublicationThis paper presents the comprehensive analysis of the sub-microwave, radio frequency band resonant metastructures’ electromagnetic properties with a particular emphasis on the possibility of their application in energy harvesting systems. Selected structures based on representative topologies of metamaterials have been implemented in the simulation environment. The models have been analyzed and their substitute average electromagnetic...
-
Electrohydrodynamic flow patterns and collection efficiency in narrow wire-cylinder type electrostatic precipitator
PublicationRecently, narrow electrostatic precipitators (ESPs) have become a subject of interest because of their possible application for the cleaning of the exhaust gases emitted by diesel engines. Diesel engines emit fine particles, which are harmful to human and animal health. There are several methods for decrease particulate emission from a diesel engines, but up to now, these methods are not enough effective or very expensive. Therefore,...
-
Detekcja i lokalizacja nieprzewodzenia tranzystorów falownika napięcia na podstawie analizy prądu obciążenia
PublicationPrzedstawiono nową metodę detekcji i lokalizacji nieprzewodzenia tranzystorów w falownikach napięcia zasilających silniki indukcyjne małej mocy. Metoda bazuje na monitorowaniu wartości dwóch sygnałów dia-gnostycznych. Pierwszy z nich, wskaźnik braku przepływu prądu, wykorzystano w celu detekcji uszkodzeń. Drugi, stosunek wartości średniej prądu do wartości średniej bezwzględnej, zawiera informacje umożliwiające lokalizację uszkodzonych...
-
Multiple output CMOS current amplifier
PublicationIn this paper the multiple output current amplifier basic cell is proposed. The triple output current mirror and current follower circuit are described in detail. The cell consists of a split nMOS differential pair and accompanying biasing current sources. It is suitable for low voltage operation and exhibits highly linear DC response. Through cell devices scaling, not only unity, but also any current gains are achievable. As...
-
Current harmonic controller in multiple reference frames for series active power filter integrated with 18-pulse diode rectifier
PublicationThe paper presents the control system and selected results of experimental tests of the AC/DC power converter consisting of an 18-pulse diode rectifier based on coupled reactors and a serial active power filter. Proportional integral controllers with decoupling components are implemented in multiple reference frames for selective line current harmonic suppression. The regulator is provided with a backtracking anti-windup mechanism...
-
Low-frequency noise in Au-decorated graphene–Si Schottky barrier diode at selected ambient gases
PublicationWe report results of the current–voltage characteristics and low-frequency noise in Au nanoparticle (AuNP)-decorated graphene–Si Schottky barrier diodes. Measurements were conducted in ambient air with addition of either of two organic vapors, tetrahydrofuran [(CH2)4O; THF] and chloroform (CHCl3), as also during yellow light illumination (592nm), close to the measured particle plasmon polariton frequency of the Au nanoparticle...
-
Assessment of organic coating degradation via local impedance imaging
PublicationThe paper presents a new approach to organic coating condition evaluation at micrometer scale using localized impedance measurements. It is based on atomic force microscopy (AFM) in contact mode. Impedance is measured between conductive AFM tip and metal substrate covered with organic coating. A single-frequency voltage perturbation signal is applied between the electrodes and current response signal is registered. As the tip is...
-
Performance of Passive and Active Balancing Systems of Lithium Batteries in Onerous Mine Environment
PublicationTo use lithium-iron-phosphate battery packs in the supply systems of any electric mining equipment and/or machines, the required conditions of work safety must be met. This applies in particular to coal mines endangered by fire and/or explosion. To meet the spark-safety conditions, the cells (together with the battery management system—BMS) must be isolated from the influence of the environment, and therefore placed in special...
-
New insights into structural, optical, electrical and thermoelectric behavior of Na0.5Bi0.5TiO3 single crystals
PublicationThe single crystals of lead-free Na0.5Bi0.5TiO3 were grown using the Czochralski method. The energy gaps determined from X-ray photoelectron spectroscopy (XPS) and optical measurements were approximately 2.92 eV. The current-voltage characteristics, depolarization current, dc (σdc) and ac (σac) electrical conductivity, and Seebeck coefficient of the crystals were investigated. The frequency/temperature-dependent electrical properties...
-
Natural convection in symmetrically heated vertical channels
PublicationThe study describes natural convection through a vertical channel, open on four sides and bound by two isothermal walls. Both balancing and infrared experimental investigations were performed in air (Pr = 0.71) to estimate the impact of channel width s and wall-to-ambient temperature difference (tw - t∞) on natural convective heat transfer, the formation of air flow patterns and the rate of flow pattern formation. The study was...
-
Dual Active Bridge (DAB) DC-DC converter for multilevel propulsion converters for electrical multiple units (EMU)
PublicationSemiconductor power devices made from silicon carbide (SiC) reached a level of technology enabling their widespread use in power converters. Two different approaches to implementation of modern traction converters in electric multiple units (EMU) have been presented in recent years: (i) 3.3-kV SiC MOSFET-based three-level PWM inverter with regenerative braking and (ii) 6.5-kV IGBT-based four-quadrant power electronic traction transformer...
-
Analysis of energy efficiency of suburban railway transport network
PublicationRising numbers of agglomeration residents cause increased need for people movement on daily basis. Because of congestion of local roads, air pollution and limited parking space, providing mass transit based on electric traction is reasonable. While the electric rail vehicles are considered highly efficient in themselves, they need to be analyzed as a part of a transport network, because energy consumption depends on operating conditions...
-
STANY NIEUSTALONE TOWARZYSZĄCE POMIAROWI IMPEDANCJI PĘTLI ZWARCIA W OBWODACH WYJŚCIOWYCH ZASILACZY BEZPRZERWOWYCH UPS
PublicationW pracy przedstawiono metodykę i wyniki pomiarów stanów nieustalonych w zasilaczu bezprzerwowym (UPS) typu on - line. Do rejestracji zdarzeń po stronie zasilania i na wyjściu UPS wykorzystano dwa przyrządy do pomiaru jakości energii elektrycznej zsynchronizowane czasowo. Rejestratory kompresują uzyskane dane pomiarowe, co może wprowadzać dodatkowe błędy pomiaru wielkości mierzonych – napięć i prądów. Dodatkowe rejestracje oscyloskopem...
-
Electrohydrodynamic Flow Patterns in a Narrow Electrostatic Precipitator with Longitudinal Wire Electrode for Various Electrode Geometries
PublicationRecently narrow electrostatic precipitators (ESPs) have become a subject of interest because of their possible application in diesel engines. In this paper results of 2-dimensional (2D) Particle Image Velocimetry (PIV) measurements of the flow patterns in a narrow ESP for a various electrode geometries are presented. The PIV measurements were carried out in the observation plane that is perpendicular to the ESP duct. The ESP was...
-
The geometry of free-standing titania nanotubes as a critical factor controlling their optical and photoelectrochemical performance
PublicationTitanium dioxide nanotubes are regarded as one of the most important functional materials and due to their unique electronic properties, chemical stability and photocorrosion resistance, they find applications in, for example, highly efficient photocatalysis or perovskite solar cells. Nevertheless, modification of TiO2 nanotubes is required to overcome their main drawback, i.e. large energy bandgap (>3.2 eV) limiting their ability...
-
Evolution of electrohydrodynamic flow of sduspended particles in a needle-to-plate negative DC corona discharge in air
PublicationCorona discharges are used for collecting dust in electrostatic precipitators (ESPs). The dust collection is mainlyrealized by the electric forces which move the ionized dust particles to the collecting electrodes. However, the presence of coronadischarge in the space between the charging and collecting electrodes in ESPs causes also the so-called ionic wind which set the gasmolecules and dust...