Filters
total: 3719
filtered: 2611
-
Catalog
- Publications 2611 available results
- Journals 4 available results
- Conferences 4 available results
- People 25 available results
- Inventions 1 available results
- Projects 1 available results
- Laboratories 1 available results
- Research Equipment 8 available results
- e-Learning Courses 128 available results
- Events 9 available results
- Offers 1 available results
- Open Research Data 926 available results
Chosen catalog filters
displaying 1000 best results Help
Search results for: pile load test
-
An accurate assignment test for extremely low‐coverage whole‐genome sequence data
Publication -
An accurate assignment test for extremely low-coverage whole-genome sequence data
Publication -
On Wilcoxon rank sum test for condition monitoring and fault detection of wind turbines
Publication -
Confirmative electric DNA array-based test for food poisoning Bacillus cereus
Publication -
Evaluating the performance of inverted pavement structure using the accelerated pavement test (APT)
Publication -
Numerical analysis of a test embankment on soft ground using an anisotropic model with destructuration
PublicationPrzeprowadzono analizę numeryczną konsolidacji podłoża słabonośnego pod obciążeniem próbnego nasypu drogowego metodą elementów skończonych. Zachowanie się gruntu słabonośnego zamodelowano przy użyciu nowego modelu konstytutywnego typu multi-laminate uwzględniającego anizotropię wytrzymałości oraz zjawisko destrukturyzacji. Wyniki obliczeń porównano z pomiarami polowymi.
-
Calculation of lead settlement curve based on CPT test results and Auger Piles.
PublicationPrzedstawiono wykorzystanie wyników statycznego sondowania CPT do określenia pełnej krzywej osiadania, aż do obciążenia granicznego. Wykorzystano wyniki badań statycznych dla 23 wierconych pali wielkośrednicowych. Przedstawiono zależności korelacyjne bazujące na analizie statystycznej.
-
Generating reliable conformance test suites for parallel and distributed languages, libraries, and APIs.
PublicationArtykuł nakreśla nową metodykę dla tworzenia Zestawów Testów Zgodności (ZTG) dla języków, bibliotek i API programowania równoległego i rozproszonego. Autor rozpoczął swoje badania w zakresie testowania zgodności dla języka równoległego sterowanego danymi Athapascan, opracował metodykę dla projektowania i analizowania ZTG nazwaną Metodą Kolejnych Zawężeń (ang. Consecutive Confinements Methods - CoCoM), stworzył narzędzie CTS Designer,...
-
Determination of PCBs in river sediment samples - proficiency test for selected Polish laboratories
PublicationW pracy opisano wyniki badań międzylaboratoryjnych dotyczących oznaczania zawartości analitów z grupy polichlorowanych bifenyli w próbkach osadu rzecznego. Badania organizowane były przez Katedrę Chemii Analitycznej Wydz. Chemicznego PG we współpracy ze Stowarzyszeniem RefMat oraz firmą LGC Promochem Sp. z o.o.
-
Test równoważności metod pomiarowych stosowanych do oznaczania pyłu zawieszonego PM10
PublicationW pracy przedstawiono przyczyny wystepowania różnic wartości stężeń pyłu PM10 uzyskiwanych metodą referencyjną a metodami opartymi na pomiarze w trybie on-site. Przedyskutowano metodykę wyznaczania równania bądź współczynnika korekcyjnego dla ciągłych metod pomiarowych w oparciu o unijną dyrektywę. Przeprowadzono weryfikację tej metodyki korzystając z danych uzyskanych z testu terenowego. Wyznaczono równanie korekcyjne przy pomocy...
-
A Multi Rig Screening Test for Thin Ceramic Coatings in Bio-Tribological Applications
PublicationZaprezentowano metodę badań ogólnej charakterystyki tribologicznej cienkich powłok ceramicznych z wykorzystaniem równoległych testów na wielu stanowiskach o różnej konfiguracji styku powierzchni trących i przy ruchu o różnym charakterze (jednokierunkowym i posuwisto zwrotnym). Przedstawiono wyniki porównania przy pomocy jednoczesnej analizy wyników testów z różnych stanowisk; w wyniku testów uzyskano ranking powłok ze wskazaniem...
-
Determination of PCBs in river sediment samples—proficiency test for selected Polish laboratories
Publication -
Assessment of the physical fitness of road cyclists in the step and ramp protocols of the incremental test
Publication -
The new footbridge in city of Cracow dynamic design and final verification in test loading
PublicationArtykuł przedstawia rozwój projektu kładki od formy architektonicznej do ostatecznego kształtu konstrukcji.
-
F05 Nine Hole Peg Test As A Measure Of Visuomotor Coordination In Huntington's Disease
Publication -
Efficiency rating of SG Diagnostics COVID-19 antigen rapid test kit
Publication -
<title>JTAG test system for RPC muon trigger in the CMS experiment</title>
Publication -
Corrosion resistance of sintered duplex stainless steels in the salt fog spray test
Publication -
Indoor accelerated controlled corrosion degradation test of small- and large-scale specimens
PublicationThe work presented here is a part of a long-term project analysing the structural behaviour of ageing marine structures. An accelerated corrosion degradation set-up was developed to reproduce corroded marine structural specimens of different degrees of degradation, controlling various natural factors, i.e., temperature, oxygen content, salinity, and flow velocity. The nine stiffened plates of 1.2 m length and 30 small scale specimens...
-
Measurements of passive components using of an IEEE 1149.4 mixed-signal test bus
PublicationW pracy przedstawiono wyniki badań nad wykorzystaniem magistrali testującej mieszanej sygnałowo IEEE 1149.4 do pomiarów elementów pasywnych zamontowanych na pakietach elektronicznych. Do badań użyto wyposażonych w magistralę układów scalonych typu STA400. Zaprezentowano metody pomiaru rezystancji pojedynczych elementów z wykorzystaniem źródła prądowego oraz źródła VH znajdującego się w analogowych modułach ABM układu STA400. Pokazano...
-
FE-simulations of a direct and a true simple shear test within a polar hypoplasticity
PublicationW artykule przedstawiono wyniki numerycznej analizy testu bezpośredniego ścinania i testu prostego ścinania w materiałach granulowanych. Obliczenia wykonano stosując metodę elementów skończonych i mikropolarne hipoplastyczne prawo konstytutywne. W analizie uwzględniono lokalizację odkształceń stycznych.
-
Toxoplasma gondii: Enzyme-Linked Immunosorbent Assay using different fragments of recombinant microneme protein 1 (MIC1) for detection of immunoglobulin G antibodies
PublicationTrzy rekombinantowe fragmenty białka antygenowego MIC1 Toxoplasma gondii (r-MIC1ex2, r-MIC1ex34 i r-MIC1) zostały wyprodukowane jako białka fuzyjne (zawierające dwie domeny oligohistydynowe na N- i C-końcu) w komórkach bakteryjnych Escherichia coli. Homogenne preparaty antygenów rekombinantowych otrzymane z zastosowaniem jednoetapowego oczyszczania metodą chromatografii metalopowinowactwa, wykorzystano następnie do immunoidentyfikacji...
-
Problem of optimal load distribution between generators minimizing risk of enegretic ship system overload.
PublicationOmówiono system rozdziału mocy czynnych pomiędzy generatorami w systemie energetycznym statku. Minimalizuje się ryzyko przeciążeń systemu przy jednoczesnej minimalizacji kosztów wytwarzania energii w systemie.
-
Steady-state characteristics and dynamic response of the PEM fuel cell to unit step change of load
PublicationPodano opis układu zasilania opartego na dwóch ogniwach paliwowych typu PEM o łącznej mocy 2.4 kW. Zaprezentowano wybrane charakterystyki statyczne i dynamiczne układu.
-
Susceptibility of the LLC Resonance Generator for Induction Heating on Changes in Load Parameters Caused by Heating the Charge
Publication -
Pelvic vertical shear fractures: The damping properties of ligaments depending on the velocity of vertical impact load
Publication -
The influence of height-do-diameter ratio on wind load of double-shell cylindrical, vertical tank
PublicationW pracy zaprezentowano skrót badań modelowych obciążenia wiatrem dwupłaszczowych zbiorników walcowych o różnych smukłościach aerodynamicznych. Przedstawiono wyniki pomiarów przeprowadzonych na dwóch modelach zbiorników z dachem pływającym i stosunku wysokości do średnicy płaszcza 0,45 i 0,25.
-
Wind tunnel experiments and numerical analysis of the wind load on double-shell cylindrical, vertical tanks
PublicationW pracy przedstawiono wyniki badań modelowych w tunelu aerodynamicznym oraz symulacji komputerowych obciążenia wiatrem pionowych, walcowych zbiorników dwupłaszczowych z dachem pływającym. W badaniach modelowych analizowano wpływ rozstawu między płaszczami zbiornika na wartość i rozkład współczynnika ciśnienia na płaszczach oraz dachu pływającym. Wyniki symulacji komputerowych przeprowadzonych w programie Fluent porównano z wynikami...
-
Determination of Equivalent Axle Load Factors on the Basis of Fatigue Criteria for Flexible and Semi-Rigid Pavements
PublicationArtykuł przedstawia analizę współczynników równoważności obciążenia osi na podstawie kryteriów zmęczeniowych stosowanych w mechanistyczno-empirycznych metodach projektowania nawierzchni. Określono wzory służące do obliczania współczynnika w oparciu o szereg kryteriów zmęczeniowych. Podano wartości liczbowe współczynników.
-
Research on water lubricated main shaft bearings in conditions of improper lubrication and cooling conducted on high torque real-life scale bush test rig
PublicationWater lubricated polymer bushes find increasingly popular use in the sliding bearings of marine propellers, water turbines and pump shafts. Such popularity is partly due to their simple construction which also means relatively affordable price. In addition, properly designed and installed water lubricated bearings may well last for over a decade. However, in practical experience one may also observe cases of rapid wear...
-
Analiza trwałości zmęczeniowej asfaltów drogowych i modyfikowanych z wykorzystaniem testu liniowego zwiększania amplitudy / Analysis of the fatigue life of neat and modified bitumens using linear amplitude sweep test
PublicationThe paper presents an evaluation of the fatigue resistance of selected Polish bituminous binders: neat bitumen 50/70, polymer modified bitumen PMB 45/80-55 and polymer highly modified bitumen PMB 45/80-80. The linear amplitude sweep (LAS) test, which is a new bitumen performance grading test developed in the USA, and was used to assess the fatigue life of the bitumens. Highly modified bitumen 45/80-80 showed 10-20 times higher...
-
Relation of the polymorphism of cyp51A sequence and the susceptibility of Aspergillus fumigatus isolates to triazoles determined by commercial gradient test (Etest) and by reference methods
PublicationThe aim of this study was to evaluate the accuracy of commercial gradient test (Etest) in the detection of triazole resistant Aspergillus fumigatus isolates using reference microdilution methods and the analysis of sequences of the cyp 51A gene. The study was performed on twenty clinical isolates which were identified as Aspergillus fumigatus based on the DNA sequences of the ITS1-2 fragment of ribosomal DNA and the β-tubulin gene,...
-
Vertical motions damping model test of a lifeboat lowered onto a flat sea surface
PublicationThe article presents the experiment’s results of the lifeboat model lowered with an initial speed and then released to fall onto a flat water surface. The purpose of the research is to determine the trajectory of the vertical boat motion and describe it with a mathematical model. This is closely related to determining the damping factor since the vertical motion is damped and the lifeboat gets balanced and stops moving after some...
-
Curb-to-Barrier Face Distance Variation an a TB51 Bridge Barrier Crash Test Simulation
PublicationThis paper addresses the problem of road safety regarding barrier placement as relative to the curb. A short summary of existing regulations is presented. Numerical simulations using the explicit finite element system Ls- Dyna are shown. In the analysis, variable distance between the barrier and the curb is assumed. The obtained result reveals that the distance has little impact on the working width of the barrier.
-
Model test and numerical simulations of earth pressure of non-cohesive soil in 3D formulation.
PublicationW pracy przedstawiono wyniki badań modelowych i obliczeń numerycznych parcia gruntu niespoistego w układzie przestrzennym działajacego na sztywną ścia- nę oporową. Podstawowe schematy wyznaczenia parcia gruntu na sztywną ścianę oporową opatre sa na obrocie ściany wokół jej wierzchołka i podstawy. Uzys- kane wyniki obliczeń przedstawiono jako rozkład składowych statycznych i normalnych wzdłuż sciany. Podano również wypadową parcia...
-
A prediction of the fault-induced instability of circuit under test as a new approach in categorisation of faults.
PublicationW artykule przedstawiono nowy sposób kategoryzacji uszkodzeń w analogowych układach elektronicznych. Zaproponowano kryterium oparte na predykcji niestabilności indukowanej przez uszkodzenie w testowanym układzie. Przyjeto, że granicą pomiędzy uszkodzeniem miękkim i katastroficznym jest najmniejsza odchyłka parametru elementu, która sprowadza układ testowany do granicy stabilności. Wzrost wartości odchyłki poza wyznaczony margines...
-
The Material Anisotropy Influence on Modelling of Rutting Test with Application of Linear Viscoelasticity Constitutive Equations
Publication -
Evaluation, Pitfalls and Recommendations for the “Water Layer Test” for Solid Contact Ion‐selective Electrodes
Publication -
The Control System Based on FPGA Technology For Fatigue Test Stand MZGS-100 PL
Publication -
Behaviour of asphalt concrete in cyclic and static compression creep test with and without lateral confinement
PublicationArtykuł przedstawia wpływ metodyki badań na określanie parametrów betonu asfaltowego. Wykazano, że badania pełzania bez skrępowania bocznego w większym stopniu uwypuklają wpływ asfaltu na parametry badanego betonu asfaltowego natomiast w badaniach ze skrępowaniem bocznym, zarówno rola asfaltu jak i szkieletu mineralnego jest uwzględniana przy ocenie parametrów betonu asfaltowego. Ponadto wykazano, że lepszymi miarami do oceny betonu...
-
NOx emission from a two-stroke ship engine: Part 2 – Laboratory test
Publication -
Cable stayed bridge over Vistula river in Plock. Dynamic analysis and site test
PublicationBudowę mostu przez rzekę Wisłę w Płocku ukończono w 2006 roku. Główne przęsło o długości 375 m zaprojektowano jako stalową konstrukcję podwieszoną. W celu weryfikacji konstrukcji zbudowano przestrzenny model MES. Badano zachowanie się konstrukcji mostu pod wpływem statycznego i dynamicznego obciążenia. W dalszym etapie przeprowadzono badania in - situ weryfikujące analizy numeryczne oraz założenia projektowe. Na bazie modelu MES...
-
Test Your Memory (TYM) as a screening instrument in clinical practice – the Polish validation study
Publication -
Artificial Neural Network (ANN)-Based Voltage Stability Prediction of Test Microgrid Grid
Publication -
SSFR Test of Synchronous Machine for Different Saturation Levels using Finite-Element Method
PublicationIn this paper the StandStill Frequency Response characteristics (SSFR) of saturated synchronous generator (SG) have been calculated using Finite Element Method (FEM) analysis. In order to validate proposed approach for unsaturated conditions FEM simulation from Flux2D software has been compared with the measurements performed on the 10 kVA, 4- poles synchronous machine ELMOR GCe64a of salient rotor construction, equipped with a...
-
Discrete modelling results of a direct shear test for granular materials versus FE results
PublicationArtykuł porównuje wyniki DEM i MES dla testu bezpośredniego ścinania materiałów granulowanych. Obliczenia MES wykonano przy zastosowaniu mikropolarnego modelu hipoplastycznego. W obliczeniach DEM z kulami i momentami kontaktu zwrócono uwagę na zjawiska mikrostrukturalne w strefie ścinania na poziomie ziaren.
-
Numerical simulations of triaxial test with sand using DEM. Archives of Hydro-Engineering and Environmental
PublicationW artykule przedstawiono wyniki symulacji badania trójosiowego dlamateriałów granulowanych. Obliczenia wykonano przy zastosowaniu metodyDEM. Pokazano wpływ momentów kontaktowych na wytrzymałoć próbki. Zbadanowpływ parametrów mikroskopowych na zachowanie się materiału. Wynikiporównano z doswiadczeniami.
-
Biofilm formation as a virulence determinant of uropathogenic Escherichia coli Dr+ strains
PublicationInfekcje dróg moczowych stanowią największy problem zdrowotny dotykający miliony osób populacji ludzkiej każdego roku. Uropatogenne szczepy Escherichia coli są najczęstszym czynnikiem etiologicznym odpowiedzialnym za wywoływanie górnych i dolnych dróg moczowych. Powyższe szczepy bakteryjne produkują szereg czynników wirulentnych pośród, których wyróżnić można eksponowane powierzchniowo polimeryczne struktury adhezyjne (fimbrie/pile)...
-
POSSIBILITY OF ASSESSMENT OF OPERATION OF SLIDING BEARINGS IN PISTON-CRANK MECHANISMS OF DIESEL ENGINES WITH REGARD TO LOAD AND TIME OF CORRECT WORK OF THE BEARINGS BY APPLYING ACOUSTIC EMISSION AS A DIAGNOSTIC SIGNAL
PublicationAbstract: The paper presents a possibility of determining (assessing) operation of sliding bearings with multilayer bushings in crank-piston mechanisms of diesel engines. Properties of load and wear, particularly fatigue and abrasive, are characterized in general. Acoustic emission as a diagnostic signal was proved to be useful for detection of the wear of sliding and barrier layers. Results of measurements of acoustic emission...
-
Analysis of load carrying capacity and destruction mechanism of an intermediate anchorage steel plate for pillar jib crane
PublicationPillar jib cranes are often mounted to existing floors with the use of an intermediate anchorage steel plate instead of using independent foundations, what is shown in the figure. Standards for steel design provide only basic rules for the design of such an intermediate plate. This study presents a simple design approach by using a numerical model in order to analyze different parameters that have significant influence in the anchorage...