Computer-aided analysis of thermal convection near electric devices
PublicationObciążalność długotrwała urządzeń elektrycznych zależy od intensywności oddawania ciepła przez te urządzenia do otoczenia. Dla zwiększenia obciążalności długotrwałej urządzeń stosuje się konwekcję wymuszoną np. z wykorzystaniem wentylatorów. Wszechstronne obserwacje i analiza procesów konwekcji naturalnej wskazują, że jej intensyfikację można uzyskać dzięki umieszczaniu w pobliżu urządzenia oddającego ciepło elementów tworzących...
-
Numerical and experimental investigation of thermal convection near electric devices with vertical channels
PublicationThis paper presents the results of numerical and experimental investigation of thermal convection near heat emitting surfaces of an electric device. For the intensification of thermal convection, special vertical channels were formed near the heat emitting surfaces of the device. An experimental test has proved that there is an optimal length of the channels – thermal convection is the most intensive then. Air velocity vectors...
-
Intensification of thermal convection near electric devices using flat screens – computer modelling
PublicationIntensification of natural thermal convection near electric devices is possible by application of additional elements as screens creating convection canals close to the device. In the earlier authors paper the results of the analysis of thermal convection with the use of only one additional screen close to the electric device were presented. This paper presents computer modelling of thermal convection when two screens near the...
-
Residual current devices in electric vehicles charging installations
PublicationThe main requirements of national regulations and international standards regarding protection against electric shock in electric vehicle charging installations are presented. The principles of using residual current devices (RCDs) in such installations are discussed. It is pointed out that RCDs are mandatory equipment for safe charging of electric vehicles. It is noted that the standards require the use of RCDs having an appropriate...
-
Requirements for Residual Current Devices Intended for Electric Vehicle Charging Systems
PublicationThe properties of residual current devices have been presented from the point of view of their ability to detect a specific shape of the residual current waveform. Moreover, the standard requirements relating to residual current protection used in electric vehicle charging installations have been pointed out. The operating characteristics of the IC-CPD and RDC-DD protections, which are intended for charging electric vehicles in...
-
Comparative Analysis of Reactive Power Compensation Devices in a Real Electric Substation
PublicationA constant worldwide growing load stress over a power system compelled the practice of a reactive power injection to ensure an efficient power network. For this purpose, multiple technologies exist in the knowledge market out of which this paper emphasizes the usage of the flexible alternating current transmission system (FACTS) and presents a comparative study of the static var compensator (SVC) with the static synchronous compensator...
-
Protection Against Electric Shock Using Residual Current Devices in Circuits with Electronic Equipment
PublicationW artykule przedstawiono problematykę stosowania wyłączników różnicowoprądowych w obwodach z urządzeniami elektronicznymi, które powodują, że prąd różnicowy ma zmienną częstotliwość lub jest odkształcony. Wyniki badań wskazują, że częstotliwość obiegająca od znamionowej oraz zawartość wyższych harmonicznych w prądzie różnicowym niekorzystnie wpływa na skuteczność ochrony przeciwporażeniowej przy zastosowaniu wyłączników różnicowoprądowych....
-
The effect of PWM frequency on the effectiveness of protection against electric shock using residual current devices
PublicationW artykule przedstawiono analizę widmową odkształconego prądu ziemnozwarciowego z obwodu silnika o regulowanej prędkości obrotowej za pomocą przemiennika częstotliwości. Oceniono skuteczność ochrony przeciwporażeniowej wykorzystującej wyłączniki różnicowoprądowe przy różnych wartościach częstotliwości PWM przemiennika. Przedstawiono charakterystykę działania proponowanego wyłącznika różnicowoprądowego.
-
The effect of PWM frequency on the effectiveness of protection against electric shock using residual current devices
PublicationW referacie przedstawiono analizę widmową odkształconego prądu ziemnozwarciowego z obwodu silnika o regulowanej prędkości obrotowej za pomocą przemiennika częstotliwości. Oszacowano wpływ tego odkształcenia na próg fibrylacji serca. Analizowano skuteczność ochrony przeciwporażeniowej wykorzystującej wyłączniki różnicowoprądowe przy różnych wartościach częstotliwości PWM przemiennika. Przedstawiono charakterystykę działania zaproponowanego...
-
Exciton quenching in emitter blends for organic light emitting devices probed by electric field-dependent time-resolved luminescence
PublicationW pracy badano mechanizm wygaszania ekscytonów w układzie dwuamina TPD:organiczny kompleks Eu:matryca TPD przez pomiar zaniku fotoluminescencji w zewnętrznym polu elektrycznym.
-
Expert opinion on the effectiveness of protection against electric shock in case of fault in an installation for electric vehicles charging
PublicationThe opinion concerns the use of residual current devices for protection against electric shock by automatic disconnection of supply in a Norwegian installation intended for charging of electric vehicles.
-
Voltage and Current Unbalance Reduction in Power Networks with Distributed Generation and Electric Vehicles
PublicationThe current development of prosumer microsources and the expected spread of electric vehicles may cause the appearance of significant current and voltage unbalance in low-voltage (LV) networks. This unbalance, which is an unfavorable phenomenon, may occur when using single-phase photovoltaic (PV) microsources and single-phase home chargers for electric vehicles. This paper presents a proposal for the symmetrization of the LV network...
-
Electrical safety in low-voltage DC microgrids with B-type residual current devices
PublicationResidual current devices (RCDs) are most popular devices used in low-voltage installations for protection against electric shock and fire. In cases of high risk of electric shock the application of RCDs is mandatory. Currently, the spread of local direct current (DC) microgrids is widely considered. This creates new challenges for protective systems, in particular those based on RCDs. The main purpose of the research is to test...
-
Comparison of EHD devices with parallel and in series spiked electrodes
PublicationIn this paper two electrohydrodynamic (EHD) devices for gas pumping and cleaning are presented. In both cases to induce an airflow in these EHD devices corona discharge was used. The discharge was generated between the spiked electrodes set parallel (the first case) or in series (the second case) and the plate electrodes. An asymmetric electric field and generated discharge result in unidirectional gas flow through the EHD device....
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublicationThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
Low-frequency tripping characteristics of residual current devices
PublicationFast development of various types of converters makes their utilization in industry and in domestic installations very common. Due to converters, an earth fault current waveform in modern circuits can be distorted or its frequency can be different than 50/60 Hz. Frequency of earth fault (residual) current influences tripping of residual current devices which are widely used in low voltage systems. This paper presents the behaviour...
-
Experimental verification of a new method of loop resistance testing in low voltage systems with residual current devices
PublicationA periodical verification of the effectiveness of protection against electric shock shall be performed in low voltage systems. The scope of this verification includes loop impedance/resistance testing. If a residual current device is installed in a tested circuit, this testing is problematic. A residual current device trips out during the test, because of the high value of measurement current. This precludes the execution of the...
-
Behavior of residual current devices at frequencies up to 50 kHz
PublicationThe use of residual current devices (RCDs) is obligatory in many types of low-voltage circuits. They are devices that ensure protection against electric shock in the case of indirect contact and may ensure additional protection in the case of direct contact. For the latter purpose of protection, only RCDs of a rated residual operating current not exceeding 30 mA are suitable. Unfortunately, modem current-using equipment supplied...
-
Residual Current Devices: Selection, Operation, and Testing
PublicationIn this book, the idea for residual current protection has been presented. The evolution in construction types of residual current devices, which has taken place over decades, is discussed. Types and functional properties of the contemporary residual current devices are described. The main parameters of these devices, from the point of view of their selection and application, are indicated. Special constructions of the protective...
-
Improving sensitivity of residual current transformers to high frequency earth fault currents
PublicationFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed...
-
Interactive Application for Visualization of the Basic Phenomena in RF and Microwave Devices
PublicationAn interactive computer application visualizing the basic phenomena in RF and microwave devices is presented. Such kind of educational package can be a very helpful tool for the students as well as for the teachers (of electronics and related fields). This paper is focused on three exemplary problems only and involves: movement of electric charge, filtering of electromagnetic waves and interference phenomena in antenna arrays. The...
-
MEASUREMENT AND ANALYSIS OF ELECTRIC FIELD INTENSITY NEAR SELECTED TRANSMITTERS OF MOBILE TELEPHONY BASE STATIONS
PublicationWireless connectivity has become increasingly common in recent times. Day by day, there are more radiocommunication devices and new ideas for them. In the near future, when the fifth generation networks will be implemented, whose main feature will be continuous wireless communication, we must approach the issue of electric field measurements more and more carefully.
-
Modification of the operating point of residual current transformers for high frequency earth fault currents detection
PublicationFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when earth fault current with high frequency components occurs. Serious hazard of electrocution exists then. One of the most important element of residual current devices is a residual current transformer with iron core. Tripping characteristic of residual current devices strictly...
-
Evaluation of applicability of classic methods of a fault loop impedance measurement to circuits with residual current devices
PublicationMeasurement of fault loop impedance in low voltage grids and systems is in most cases performed to verify the effectiveness of protection against electric shock by automatic disconnection of supply. For the sake of measurement accuracy, it is advisable to perform it using large current. Unfortunately, in circuits with residual current devices which are very widely used nowadays, a large measurement current may trigger those devices...
-
Capillary pumped loop as a tool for collecting large heat fluxes from electronic devices on warships
PublicationThe combat potential of future warships will be directly related to the use of modern electronic devices being parts of advanced systems, such as, for instance, radar systems, fire aiming systems, fire detection systems, electric drive systems, and even electronic and radio-electronic weaponry, railguns and lasers, installed on these warships. The capacity and functionality of these devices is continually increasing, at decreasing...
-
Metrological analysis of an computerized system of protection against electric shock in circuits with variable speed drives
PublicationDrive systems, that can be operated at variable speed, are equipped with power electronics converters. This causes distortion of the earth current, and consequently the need to take into account the use of proper protective devices in relation to earth current harmonics. This paper presents a system for protection against electric shock in circuits with power electronics converters and metrological analysis indicating the requirements...
-
Behavior of residual current devices at earth fault currents with DC component
PublicationLow-voltage electrical installations are increasingly saturated with power electronic converters. Due to very high popularity of photovoltaic (PV) installations and the spread of electric vehicles (EV) as well as their charging installations, DC–AC and AC–DC converters are often found in power systems. The transformerless coupling of AC and DC systems via power electronic converters means that an electrical installation containing...
-
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublicationLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...
-
Energy savings by application of supercapacitor storage in trolleybus supplying station - analysis of experimental results
PublicationStorage devices can be divided into two groups: on-board energy storage devices, which are placed in the vehicles and off-board energy storage devices situated in traction substations or between them. Current research is focused mainly on two objectives. The first is to reduce the energy demand by introducing on-board energy storages in light electric vehicles like trams, trolleybuses or electrobuses. The latter is to provide a...
-
Testing sensitivity of A-type residual current devices to earth fault currents with harmonics
PublicationIn many applications, modern current-using equipment utilizes power electronic converters to control the consumed power and to adjust the motor speed. Such equipment is used both in industrial and domestic installations. A characteristic feature of the converters is producing distorted earth fault currents, which contain a wide spectrum of harmonics, including high-order harmonics. Nowadays, protection against electric shock in...
-
Influence of electric, magnetic and electromagnetic fields on the circadian system – current stage of knowledge
PublicationOne of the side effects of each electrical device work is the electromagnetic field generated near its workplace. All organisms, including humans, are exposed daily to the influence of different types of this field, characterized by various physical parameters. Therefore, it is important to accurately determine the effects of an electromagnetic field on the physiological and pathological processes occurring in cells, tissues and...
-
Room temperature depinning of the charge-density waves in quasi-two-dimensional 1T-TaS2 devices
PublicationWe report on the depinning of nearly commensurate charge-density waves in 1T-TaS2 thin films at room temperature. A combination of the differential current–voltage measurements with the low-frequency noise spectroscopy provides unambiguous means for detecting the depinning threshold field in quasi-2D materials. The depinning process in 1T-TaS2 is not accompanied by an observable abrupt increase in electric current—in striking contrast...
-
Hybrid electrode materials for fast performance devices
PublicationEnergy storage devices such as Electrochemical Double Layer Capacitors and other types of the electrochemical capacitors require chemically stable, non-soluble, electrochemically active electrode materials compatible with appropriate electrolytes. Factors which determine their applicability are derived from so called electrochemical window of electroltes, nature of charge accumulation and their kinetics. On the other hand technological...
-
RCDs Tripping in the Range from DC to AC 50 kHz for Slowly Rising Residual Current
PublicationThe wide use of power electronic converters means that in many low-voltage systems earth fault currents containing components from DC to AC of various frequencies have to be taken into account. Due to the tendency to increase the modulation frequency in converters, components of higher frequencies may be in the order of several tens of kilohertz. Therefore, it is very important to verify the behavior of devices for protection against...
-
Tripping of F-type RCDs for sinusoidal residual current with superimposed smooth DC component
PublicationRecent trends in green energy development make that photovoltaics and electric vehicles are applied on an increasing scale. In both photovoltaic and electric vehicle charging installations, a significant value of DC component of the earth fault current may appear, which is a challenge, in particular, for commonly used residual current devices (RCDs). This paper presents results of the laboratory test on the operation of F-type...
-
Experimental investigations and simulations of the microturbine unit with permanent magnet generator
PublicationIn dispersed power generation, low power devices are used for local combined generating of heat end electric power. There are developing concepts of micropower plants with electric generators driven by steam or gas microturbines. The paper presents the results of an experimental investigations of the microturbine set consists of the turbine with partial admission, permanent magnet generator and three phase AC-to-DC rectifier. The...
-
Możliwości zastosowania zasobnikowych jednostek trakcyjnych na liniach kolejowych na przykładzie Pomorskiej Kolei Metropolitalnej
PublicationW artykule zwrócono uwagę, że zasobniki stosowane głównie do rekuperacji energii, mogą być również wykorzystane do zasilania pociągów na niezelektryfikowanych i zelektryfikowanych odcinkach linii kolejowych. Innowacyjność tego rozwiązania wykazano na podstawie dwóch aplikacji kolejowych elektrycznych zasobnikowych jednostek trakcyjnych: pierwszej funkcjonującej od 2014 roku na linii Utsunomiya – Karasuyama w Japonii oraz drugiej,...
-
Stirling engines powered by renewable energy sources
PublicationStirling engine is a device that produces mechanical energy using heat from any source of energy, without the need of combustion of any fuel inside the device. Renewable energy sources, which are mostly low-temperature energy sources, can be used to produce mechanical and electrical energy in Stirling engines. The paper presents an overview of the existing prototype Stirling engines designed for using of low-temperature energy...
-
Horyzont energoelektroniczny obiektów morskich
PublicationW artykule zaprezentowano współczesne kierunki rozwoju energoelektroniki, w tym w szczególności dotyczące obiektów morskich. Przedstawiono podstawowe parametry aktualnie stosowanych w energoelektronice przyrządów półprzewodnikowych, jak również wykazano interdyscyplinarny charakter rozwoju tej dziedziny. Na przykładzie wybranych urządzeń energoelektronicznych przedstawiono ich komercyjne zastosowania oraz podział i miejsce w łańcuchu...
-
Framework for Integration Decentralized and Untrusted Multi-vendor IoMT Environments
PublicationLack of standardization is highly visible while we use historical data sets or compare our model with others that use IoMT devices from different vendors. The problem also concerns the trust in highly decentralized and anonymous environments where sensitive data are transferred through the Internet and then are analyzed by third-party companies. In our research we propose a standard that has been implemented in the form of framework...
-
Badanie wybranych właściwości wyłączników różnicowoprądowych typu F
PublicationW instalacjach elektrycznych niskiego napięcia instaluje się coraz więcej przekształtników energoelektronicznych (systemy fotowoltaiczne, instalacje ładowania pojazdów elektrycznych, układy napędowe o regulowanej prędkości obrotowej silnika), a mają one wpływ na dobór typu wyzwalania wyłączników różnicowoprądowych (AC, A, F lub B). W obwodach, w których pojawia się prąd różnicowy zawierający składowe o częstotliwości innej niż...
-
Comparative analysis of switched reluctance motor control algorithms
PublicationПредмет исследования. Развитие микропроцессорной техники и силовой электроники позволило создавать недорогие и эффективные системы управления различными электромеханическими объектами, которые ранее широко не использовались из-за сложности управления. К таким устройствам можно отнести вентильно-индукторные электрические машины. Данные машины широко применяются в различных практических разработках, например, в тяговом электроприводе,...
-
Structural Health Monitoring of Overhead Power Transmission Lines
PublicationStructural Health Monitoring (SHM) is a novel and continuously developing branch of science and technology that draws attention of scientists all over the world. It creates opportunities to detect, localize and identify structural damage of various types such as: line breakage, permissible sag, bolt loosening, fatigue cracking or insulator contamination. On the other hand the methods used to estimate the remaining operational...
-
Application of Smart IoT Technology in Project Management Scenarios
PublicationThe report presents a low-cost and flexible solution to control and monitor home and industrial appliances. The popularity of automation devices has increased greatly in recent years due to higher affordability and simplicity through IoT phone and tablet connectivity. For this purpose, we have developed the IoT Outlet: a stand-alone communication unit, used to connect outlets to the internet. The IoT Plug is a power switch which...
-
Synthesis and Characterization of Poly(zwitterionic) Structures for Energy Conversion and Storage
PublicationZwitterions are unique class of molecules that possess two functional groups bearing electric charges, one positive and second negative. This setup results in peculiar properties such as high water retention and anti-fouling capability. Therefore, zwitterionic coatings and gels are commonly applied in e.g. biosensing and bioelectronic devices. Despite those applications, there are other perspectives for zwitterionic materials....
-
Quenching effects in organic electroluminescence
PublicationWe examine various electronic processes that underlie the quenching of the emission from highly efficient phosphorescent and electrophosphorescent organic solid-state molecular systems. As an example, we study the luminescent efficiencies from the phosphorescent iridium (III) complex, fac tris (2-phenylpyridine) iridium [(Ir (ppy)3] doped into a diamine derivative doped polycarbonate hole-transporting matrix and in the form...
-
Tripping of F-type RCDs for high-frequency residual currents
PublicationResidual current devices (RCDs) are apparatus commonly used for protection against electric shock in low-voltage electrical installations. They protect people in the case of an earth fault or even in the case of direct contact with the live parts. However, to be effective protective devices, RCDs have to detect residual currents of various waveform shapes which appear in modern electrical installations. For this purpose, RCDs are...
-
Tripping of F-type RCDs for High-Frequency Residual Currents
PublicationResidual current devices (RCDs) are apparatus commonly used for protection against electric shock in low-voltage electrical installations. They protect people in the case of an earth fault or even in the case of direct contact with the live parts. However, to be effective protective devices, RCDs have to detect residual currents of various waveform shapes which appear in modern electrical installations. For this purpose, RCDs...
-
Finite-difference time-domain analyses of active cloaking for electrically-large objects
PublicationInvisibility cloaking devices constitute a unique and potentially disruptive technology, but only if they can work over broad bandwidths for electrically-large objects. So far, the only known scheme that allows for broadband scattering cancellation from an electrically-large object is based on an active implementation where electric and magnetic sources are deployed over a surface surrounding the object, but whose ‘switching on’...
-
Determination of pseudocapacitance chan ges of nickel oxide NiO electrode with use of dynamic electrochemical impedancje spectroscopy
PublicationThe electrochemical capacitors (ECs) are attractive energy storage devices which can be applied in many electronic products (e.g., cameras, laptops, cell phones) or hybrid electric vehicles (HEV). The energy storage in ECs is based on capacitive (the electrical double layer charging/discharging) and pseudocapacitive (additional charge provided by faradic reaction) phenomena. Considering the electrodes exhibiting pseudocapacitance,...