Resonant ultrasonic spectroscopy in high-voltage varistor spectroscopy
PublicationResonant spectroscopy is an effective non-destructive testing method focused on defects in tested objects. The testing procedure, based on the resonant pattern, allows rejection of the tested samples with defects which do not fit the pattern. A sweeping frequency method has been used to measure the spectrum of resonances in high-voltage varistors. As a result we can observe resonances that depend directly on inhomogeneity of the...
-
Diagnostics of high-voltage varistor quality using resonant ultrasound spectroscopy
PublicationResonant spectroscopy is an effective nondestructive testing method focused on defects detection in tested objects. Resonance spectrum contains an information about the mechanical properties and particularly about the structural homogeneity of the whole object. A swept frequency method has been used to measure the selected resonant frequencies range. The system for measurement of resonant ultrasound spectroscopy of high-voltage...
-
Diagnostics of high-voltage varistors by acoustic emission
PublicationWarystory, szeroko stosowane w ogranicznikach przepięć, powinny być testowane na końcowym etapie ich wytwarzania. Stosowane metody testowania wymagają użycia wysokich napięć i prądów o dużych natężeniach, co jest nidogodne, destrukcyjne i wymaga poboru relatywnie dużych pocy. W artykule zaproponowano zastosowanie analizy sygnału emisji akustycznej do predykcji jakości struktury warystora. Opisano system przygotowany do tej aplikacji,...
-
Classification of high-voltage varistors into groups of differentiated quality
PublicationThe research was aimed on defining a factor of quality for high-voltage varistors using Non-Destructive Testing (NDT) techniques, which could be applied during the production testing. The newly proposed parameter Q determined on the basis of the lowest resonant frequency fr measured within the preselected frequency range was taken into account. The parameter Q was defined for ZnO structures after firing, without metallized contacts....
-
Third harmonic index as a diagnostic tool of high-voltage varistors
PublicationThe recommended methods for standard testing of high-voltage varistors demand application of high voltages and intensive currents that is inconvenient and needs extensive power consumption. These methods require metallization of the prepared ZnO structures that increases costs of testing. Another method of varistor quality and endurance evaluation by the third harmonic index measurement at relatively low voltage range has been...
-
Quality assessment of high voltage varistors by third harmonic index
PublicationHigh voltage varistors that consist of grained ZnO have to be tested before assembling into a surge arrester. The existing methods demand a usage of high voltages and intensive currents that is inconvenient, destructive and needs extensive power consumption. Additionally, these methods require metallization of the prepared varistor structures that increases costs. We propose another method of varistors quality assessments by a...
-
High voltage protective assembly.
PublicationW referacie opisano zestaw zabezpieczeniowy, składający się z bezpiecznika i ogranicznika przepięć, przeznaczony dla napowietrznych słupowych stacji transformatorowych średnich napięć. Zastosowany warystorowy ogranicznik przepięć spełnia jednocześnie rolę wspornika dla bezpiecznika gazowydmuchowego. W referacie przedstawiono budowę, podstawowe parametry, przykłady zastosowania oraz wyniki badań zwarciowych zestawu.
-
A Development of a Capacitive Voltage Divider for High Voltage Measurement as Part of a Combined Current and Voltage Sensor
PublicationThis article deals with the development of capacitive voltage divider for high voltage measurements and presents a method of analysis and optimization of its parameters. This divider is a part of a combined voltage and current sensor for measurements in high voltage power networks. The sensor allows continuous monitoring of the network distribution status and performs a quick diagnosis and location of possible network failures....
-
High - voltage thin - layer fuses
PublicationZaprezentowano nową technologię i konstrukcję bezpieczników wysokonapięciowych wykorzystując technologie stosowane w mikroelektronice. Cienką warstwę topika naniesiono na quasiceramiczne podłoże. Wykonane modele bezpieczników charakteryzują się wysoką pewnością działania oraz małymi stratami I2t.
-
A High-Efficient Low-Voltage Rectifier for CMOS Technology
PublicationA new configuration of rectifier suiting CMOS technology is presented. The rectifier consists of only two nchannel MOS transistors, two capacitors and two resistors; for this reason it is very favourable in manufacturing in CMOS technology. With these features the rectifier is easy to design and cheap in production. Despite its simplicity, the rectifier has relatively good characteristics, the voltage and power efficiency, and...
-
The Issues of Reactive Power Compensation in High-voltage Transmission Lines
PublicationThis paper discusses the selection of compensation shunt reactors for a double-circuit 400 kV transmission line using the example of the newly built Elk Bis – Alytus transmission line. The analysis takes into account various conditions of the power system. The published results relate to voltage levels in steady states and during switching processes and short circuits.
-
New Architecture of Solid-State High-Voltage Pulse Generators
PublicationThe application of the nanosecond pulsed electric field (nsPEF) for biomedical treatments has gained more interest in recent decades due to the development of pulsed power technologies which provides the ability to control the electric field dose applied during tests. In this context, the proposed paper describes a new architecture of solid-state high-voltage pulse generators (SSHVPG) designed to generate fully customised sequences...
-
Analysis of pressure ratio in the intake in dependence on high-voltage behaviours
PublicationPower control in spark ignition engines by regulating the intake air is performed. The control unit needs information about the air pressure conditions which then enters the combustion chamber. The information about the intake air pressure is an important quantity for optimal control of combustion mixtures. The paper describes some types of sensors that are used to measure the air intake temperature. Air pressure in the intake...
-
Evaluative analysis of 2- and 3-level DC/DC converters for high-voltage high-power applications
Publication -
The Effect of Protrusions on the Initiation of Partial Discharges in XLPE High Voltage Cables
PublicationThis paper is focusing on 3D Finite Elements Analysis (FEA) based modelling of protrusions as defects or imperfections in the XLPE high voltage cable. This study is aiming to examine the impact protrusions have on the initiation of partial discharges. Spherical and ellipsoidal protrusions with different sizes at the conductor screen of the high voltage cable is an essential content of this paper. In addition, a spherical gas-filled...
-
Synchronized six-step voltage generation in high-speed PMSM drive
PublicationSynchronized voltage generation has already been considered in the context of pulse width modulation (PWM). References prove that synchronized PWM substantially decreases subharmonics in inverter output voltage when operating with low switching-to-fundamental frequency ratio. This paper identifies problems of unsynchronized voltage generation in electric drives under six-step inverter operation. Guidelines for the synchronization...
-
The effect of cable duct diameter on the ampacity of high-voltage power cables
PublicationThe ampacity of power cables depends, among others, on the conditions of heat dissipation from the cable to the environment. Cables are usually laid directly in the ground, but in some sections, they may be placed in ducts, which adversely affects the ampacity of the cable line. The paper presents heat transfer phenomena for cables installed in pipe-type ducts filled with air. The effect of cable duct diameter on this ampacity...
-
High power, medium voltage, modular active power filtering system
Publication -
Problems of Selecting Protection for Shunt Reactors Working in Extra-High Voltage Grids
PublicationThis paper presents difficulties encountered when designing protection devices for shunt reactors connected directly to extra-high voltage grids. Using the example of the 400 kV Ełk Bis substation, it has been demonstrated that protection of a shunt reactor based on equipment using measurements of electrical signals from voltage and current transformers has its limitations and, in some cases, may be insufficient.
-
Protection of Earthing Reactor Connected to the Star Point of a High Voltage Shunt Reactor
PublicationThe article presents the problem of protection of earthing reactors connected to the star point of shunt reactors in high voltage lines, with particular regard to the detection of internal faults. Model analyses for an actual system commissioned in 2015, which is intended to be provided with earthing reactors, are included.
-
Computer-Aided Calculations of Earth Potential Rise in High Voltage Overhead Lines
PublicationHigh voltage overhead power lines with earth wires comprise towers made of conductive material. Some towers are in locations where people can be expected to be either for a long time or for a short time but very frequently. Evaluation of shock hazard near such towers requires calculation of line-to-earth short-circuit current, earth current and especially earth potential rise. Number of towers in high voltage power lines can exceed...
-
Optimization of thermal backfill configurations for desired high-voltage power cables ampacity
PublicationThe ampacity of high-voltage power cables depends, among others, on their core cross-sectional area as well as thermal resistivity of the thermal backfill surrounding the cables. The cross-sectional area of the power cables’ core is selected according to the expected power to be transferred via the cable system. Usually, the higher the power transfer required, the higher the cross-sectional area of the core. However, the cost of...
-
Response of high voltage disconnector under seismic excitation - experimental and numerical study
PublicationThe efficiency of the energetic infrastructure system is a very import safety issue in the region experienced by the ground motion. The aim of the present paper is to show the results of the experimental and numerical study focused on the earthquake-induced response of the high voltage disconnector, which is an important element of energetic network. First, the impact tests as well as the sweep-sine shaking table tests were conducted....
-
Analysis of Ferroresonance Mitigation Effectiveness in Auxiliary Power Systems of High-Voltage Substations
PublicationFerroresonance in power networks is a dangerous phenomenon, which may result in overcurrents and overvoltages, causing damage to power equipment and the faulty operation of protection systems. For this reason, the possibility of the occurrence of ferroresonance has to be identified, and adequate methods need to be incorporated to eliminate or reduce its effects. The aim of this paper is to evaluate the effectiveness of ferroresonance...
-
Electrical Tree Growth Behavior Under AC and DC High Voltage in Power Cables
PublicationThis work investigates the impact of an applied AC and DC high voltage on the electrical tree behavior in extruded cross-linked polyethylene (XLPE) insulation based on simulation and experimental validation. Extensive partial discharge (PD) testing methods are being implemented for high voltage cables under AC voltage for monitoring their condition. However, these PD testing methods cannot be utilized for power cables under DC...
-
Computer-aided Analysis of Induced Sheath Voltages in High Voltage Power Cable System
PublicationThis paper concerns the effect of configuration of high voltage power cables on induced voltages in their metallic sheaths. One, two or three cables per phase and phase sequence of the cables are considered. Computing of the voltages was performed for a normal operation and in case of earth fault. Various ways of the sheaths bonding are considered as well. Shock hazard and voltage stress of non-metallic outer sheath of cables are...
-
Case studies of resonance phenomena in high voltage overhead power lines with shunt reactors
PublicationMisguided design of the towers of power transmission lines can lead to serious problems such as voltage asymmetry, overvoltages, electric arc extinction difficulties or resonance – in case of double circuit line with shunt reactors. The paper points out those threats on example of 400 kV double circuit overhead transmission line with shunt reactors.
-
Safety issues referred to induced sheath voltages in high-voltage power cables – case study
PublicationLoad currents and short-circuit currents in high-voltage power cable lines are sources of the induced voltages in the power cables’ concentric metallic sheaths. When power cables operate with single-point bonding, which is the simplest bonding arrangement, these induced voltages may introduce an electric shock hazard or may lead to damage of the cables’ outer non-metallic sheaths at the unearthed end of the power cable line. To...
-
Application of 3D graphic software and GIS in visual impact assessment of high-voltage overhead transmission lines
Publication -
Magnetic and capacitive couplings influence on power losses in double circuit high voltage overhead transmission line
PublicationPurpose – The paper aims to discuss problems of power and energy losses in a double-circuit overhead transmission line. It was observed from energymeters’ readings, that in such a line, active power losses can be measured as “negative”. The “negative” active power losses appear when the active power injected to the circuit is lower than the active power received at the circuit end. The purpose of this paper is to explain this phenomenon. Theoretical...
-
Magnetic and capacitive couplings influence on power and energy measurement in double circuit high voltage overhead transmission line
PublicationThe paper discusses influence of magnetic and capacitive couplings on power and energy measurement in case of double circuit high voltage overhead transmission line. There are presented and discussed various factors influencing the power flow among the line‟s circuits. Mathematical model based calculations results are compared to the real transmission line measurements.
-
Analysis of Induced Voltages and Power Losses in High Voltage Power Cables for Selected Methods of Cables Sheaths Bonding
PublicationPower is increasingly supplied to city centres with 110 kV cable lines. This is a convenient way to supply power, and practically the only one possible in areas of dense urban development. A high-voltage cable contains a coaxial metallic sheath, in which in normal operation and in fault conditions (during short-circuits) significant line-to-earth voltages can be induced, which threatens electric shock and/or damage to the cable’s...
-
The Finite Elements Method application to assesment the impact of turbulence generated by wind turbines on their lacation inclose proximity of overhead high voltage power transmissionlines
PublicationThe paper presents selected aspects of construction of wind turbines location concerning aerodynamic impact on power lines. Reaserch is based on the source data concerning the aerodynamic impact of a wind farm consisting of 8 turbines and 400 kV power line, an analysis of the possibility of wind farm locating in the immediate vicinity of the line was carried out. There are serious problems with locating higher capacity wind farms...
-
Potential of silicon carbide MOSFETs in the DC/DC converters for future HVDC offshore wind farms
Publication -
Dynamics of fault arc traveling along busbars in high voltage switchboards = Dynamika łuku zwarciowego przemieszczającego się wzdłuż szyn rozdziel-nic wysokiego napięcia
PublicationThe paper presents the results of magnetic induction and electrodynamic force calculations acting on arc column during short-circuit in medium voltage air-insulated bus-bars. The gap between the bars was 120 mm and the prospective short-circuit currents ranged from 4 kA to 8 kA. The paper also shows the measurement results of average velocity fault arc depending on currents arc diameter and arc current was established and described....
-
Problems of varistor quality assessment during exploitation
PublicationVaristors are commonly used elements which protect power supply networks against high-voltage surges or lightning. Therefore, quality and endurance of these elements is important to avoid losses when an expensive laboratory equipment would not be protected from random overvoltages. Additionally, excessive leakage currents generate serious costs due to high energy consumption. The paper presents shortly properties of varistors that...
-
Diagnostics of zno varistors by means of nondestructive testing
PublicationStandard industrial testing of high-voltage varistors for surge arresters demands application of high voltages and intensive currents. Nondestructive methods for varistor quality and endurance evaluation have been proposed and described. They rely on the application of resonant ultrasound spectroscopy, electro-ultrasonic spectroscopy, noise measurement and nonlinearity testing at voltages lower than continuous operating range....
-
Application of infrared thermoography to non-contact testing of varistors
PublicationTesting of varistors using thermography was carried out in order to assess their protective properties against possible overvoltage phenomena in the form of high-level voltage surges. An advantage of the thermography technique is non-contact temperature measurement. It was proposed to assess the properties of varistors workingin electronic devices as protective elements, on the basis of estimating temperature increments on varist...
-
Quality assessment of low voltage surge arresters
PublicationUsers expect reliable operation of the surge arrester during overvoltages, which may originate from a switching process or a lightning discharge. The necessary conditions to guarantee these expectations are: appropriate construction of the surge arrester, its production being maintained in accordance with technical standards, and a positive results of the type test (as well routine and acceptance tests). The recipient, especially...
-
Quality assessment of ZnO-based varistors by 1/f noise
PublicationNoise has been used as a diagnostic tool of surge arrester varistor structures comprising of ZnO grains of various type and size. The physical and electrical properties of the measured samples have been described. In the experimental study, the applied measurement system and the results of noise measurements for the selected structures of varistors designed for the continuous working voltage 280 V, 440 V and 660 V have been presented....
-
Leakage Current Measurements of Surge Arresters
PublicationThe paper presents the methods of assessing the technical condition of varistor surge arresters used in laboratory tests and in operation—performed without disconnecting the arresters from the network. The analysis of the diagnostic methods was supplemented with the results of the measurements of the leakage current of arresters coming directly from their production and used in the power industry. Among the available methods of...
-
Problemy przyłączania farm wiatrowych do systemu elektroenergetycznego z wykorzystaniem kabli WN
PublicationArtykuł prezentuje problemy, jakie rodzi przyłączanie farm wiatrowych do systemu elektroenergetycznego za pomocą kabli wysokiego napięcia. Autor wskazuje możliwe problemy z kompensacją mocy biernej, w zależności od sposobu przyłączenia dławika kompensacyjnego i nastawień układów regulacji mocy biernej oraz napięcia farmy wiatrowej. Artykuł porusza też zagadnienia zwiększenia strat mocy czynnej powodowanych instalacją dławików kompensacyjnych.
-
Algorytmy wykrywania krawędzi w obrazie
PublicationWykrywanie krawędzi jest pierwszym etapem w cyfrowym przetwarzaniu obrazów. Operacja ta polega na usunięciu informacji takich jak kolor czy też jasność, a pozostawieniu jedynie krawędzi. Efektem tej operacji jest znaczna redukcja ilości danych do dalszej analizy. Pozwala to na zastosowanie w następnych etapach bardziej złożonych algorytmów rozpoznawania obiektów na podstawie kształtu. W artykule zaprezentowano zastosowanie algorytmów...
-
Modelowanie bezpiecznika rozłącznikowego w układach formowania impulsów wielkiej mocy
PublicationProblem modelowania bezpieczników o dużej dynamice wyłączania prądu jest zagadnieniem szeroko opisywanym w literaturze. Układy takie mogą być wykorzystane w szczególności do formowania impulsów wysokiego napięcia o wartościach rzędu setek kV, charakteryzujących się czasem trwania rzędu ułamka μs. W niniejszej pracy przedstawiono empiryczny model bezpiecznika wielotopikowego, rozszerzony w oparciu o wyniki badań eksperymentalnych.
-
Nowoczesne układy przekształtników wielopoziomowych do zasilania statków z lądu
PublicationW artykule poruszono tematykę zasilania statków zacumowanych w porcie z lądowej sieci elektroenergetycznej poprzez wykorzystanie nowoczesnych konstrukcji przekształtników energoelektronicznych. W treści pracy zaprezentowano porównanie dwóch topologii wysokonapięciowych przekształtników wielopoziomowych. Porównano konstrukcje przekształtników z klasycznym transformatorem wielouzwojeniowym oraz z transformatorami wysokoczęstotliwościowymi.
-
Voltage Transients Transfer over Medium Voltage Instrument Transformers
PublicationThis paper presents voltage harmonic transfer accuracy problems through voltage transformers which are used in power quality monitoring systems in medium and high voltage grids. A simplified lumped parameters circuit model of the voltage transformer is proposed and verified by simulation and experimental investigations. A number voltage transformers typically used in medium voltage grid has been tested in the conducted disturbances...
-
Voltage Harmonics Transfer through Medium Voltage Instrument Transformers
PublicationVoltage transformers are widely used in power quality monitoring systems in medium and high voltage grids. This paper presents accuracy problems related to voltage harmonics transfer through instrument transformers. A simplified lumped-parameters wideband circuit model of the voltage transformer is proposed and verified by simulation and experimental investigations. A number of voltage transformers have been tested in the frequency...
-
Wielopoziomowe przekształtniki średniego napięcia (SN) o budowie modułowej
PublicationW artykule omówiono wybrane zagadnienia dotyczące zastosowań wielopoziomowych przekształtników średniego napięcia (SN) w układach napędowych o regulowanej prędkości, zwłaszcza w układach z izolacją od sieci zasilającej. W opracowanym przekształtniku zastosowano izolację galwaniczną od sieci zrealizowaną za pomocą izolowanych przetwornic dc-dc z transformatorami wysokiej częstotliwości (> 5 kHz). Przedstawiono zarejestrowane przebiegi...
-
Pompownie dużej mocy z falownikiem wędrującym średniego napięcia
PublicationArtykuł zawiera rys rozwoju napędów przekształtnikowych w stacjach pomp, w szczególności regulacji wydatku kilku pomp, po kolei, przez jeden przemiennik częstotliwości. Omówiono podstawy teoretyczne zjawiska pola niestłumionego i napięcia resztkowego silników, które utrudniają szybkie przełączania silnika pompy pomiędzy zasilaniem regulowanym przez falownik a zasilaniem z sieci. Przedstawiono zasady transferu (przełączania) synchronicznego...
-
WARUNKI REZONANSOWE W WĘŹLE Z KOMPENSATOREM SVC
PublicationInstalowanie kompensatorów statycznych w sieciach rozdzielczych i przesyłowych służy poprawie profili napięciowych. Kompensatory jako źródła mocy biernej zwiększają stabilność napięciową systemu. Pozwalają także na szybszą odbudowę systemu w przypadku awarii napięciowej. W artykule zaprezentowano wpływ struktury i wysterowania układu SVC na zmianę impedancji w układzie zasilania. Ma to bezpośredni wpływ na częstotliwości, przy...