displaying 1000 best results Help
Search results for: ELECTRO-OPTIC EFFECT
-
Optical activity and electro-optic effect of l-arginine doped KDP single crystals
PublicationWe have used the modified polarimetric methods to study optical activity (OA) in the potassium dihydrogenphosphate (KDP) crystals doped with 0.7, 1.4 and 3.8 wt% L-arginine (L-arg) amino acid. Crystals were grown by the temperature reduction method. Small changes of the absolute eigen waves ellipticity and OA values in doped crystals were noted. We have experimentally determined the signs of OA in the [1 00] and [01 0] directions...
-
Dielectric and electro-optic studies of a bimesogenic liquid crystal composed of bent-core and calamitic units
Publication -
Fabrication of La-Doped Bi4Ti3O12 Ceramics
PublicationLa-modified Bi4Ti3O12 is a typical ferroelectric, piezoelectric and electro-optic material, having relatively low coercive field, low dielectric constant, high Curie temperature and high breakdown strength. Goal of the present research was to apply mixed oxide method for fabrication of BiTLax ceramics, study its chemical composition, crystalline structure and microstructure. The compound BiTLax for x=0, 0.25, 0.5, 0.75 ceramic...
-
Nanolayers in Fiber-Optic Biosensing
PublicationIn this chapter, fiber-optic sensors based on nanolayers or thin films and their ability to perform biophotonic measurements is presented. In the last decade, fiber-optic sensors have gained popularity as biosensing devices. This has been made possible because of the design and the integration of new materials in fiber-optic technology. Nanolayers and thin films made from various materials such as nanodiamond (NCD), boron-doped...
-
The silver layers in fiber-optic sensors
PublicationIn this paper a method of application of the silver layers on the surface of an optical fiber was proposed. The optical properties and surface quality of the silver layer was examined by optical microscopy. The reflection and transmission of the sample were investigated. To evaluate the silver mirror it was placed in a fiber optic Fabry-Perot interferometer and the quality of the spectra was analyzed. The commercial mirror was...
-
Temperature Sensors Based on Polymer Fiber Optic Interferometer
PublicationTemperature measurements are of great importance in many fields of human activities, including industry, technology, and science. For example, obtaining a certain temperature value or a sudden change in it can be the primary control marker of a chemical process. Fiber optic sensors have remarkable properties giving a broad range of applications. They enable continuous real-time temperature control in difficult-to-reach areas, in...
-
Research of hydrotronic variable displacement radial piston pump with electro -pneumatic control
PublicationThe paper presents the developed new electro-pneumatic control (pneumotronic) system for hydraulic fixed-displacement radial piston pump. Hydraulic fixed-displacement radial piston pump equipped with the proposed control system changes into hydrotronic variable-displacement radial piston pump. Pump flow rate control is realized by means of programmable logic controller, electro-pneumatic valves, pneumatic cylinders and a sensor.
-
Electro-chemo-mechanical properties in nanostructured Ca-doped ceria (CDC) by field assisted sintering
PublicationRecent investigations have shown that highly oxygen defective cerium oxides generate non-classical electrostriction that is superior to lead-based ferroelectrics. In this work, we report the effect of field-assisted spark plasma sintering (SPS) on electro-chemo-mechanical properties of calcium doped ceria (CDC). Nanometric powders of Ca.10 nm are rapidly consolidated to form polycrystalline nanostructures with a high degree of...
-
Application of titanium dioxide thin films in fiber optic sensors
PublicationThe advance in the nanotechnology and fabrication of micro- and nanostructures has significant impact on development of new optical sensors. Presented study focuses on the applications of the titanium dioxide (TiO2) thin films in fiber optic sensors. The concept of a sensing fiber optic interferometer integrating TiO2 thin film is presented. The cavity of this interferometer is delimited by a 80 nm film fabricated on the end-face...
-
Broadband fiber optic communication systems
e-Learning Courses -
Electro-photoluminescence in organics
PublicationElektro-fotoluminescencję zaobserwowano w układzie ITO(+)/emiter/Ca(-), gdzie emiter wzbudzany światłem UV (350nm) zawierał dendrymer aminowy m-MTDATA, pochodną fenantroliny BPT i organiczny kompleks platyny PtL2Cl. Widmo fotoluminescencji pochodzi od singletowych ekscypleksów m-MTDATA:BPT i trypletowych ekscypleksów m-MTDATA:PtL2Cl. Ze wzrostem pola elektrycznego następuje wygaszanie ekscypleksów na skutek ich dysocjacji na nośniki...
-
Response of a fiber-optic Fabry-Pérot interferometer to refractive index and absorption changes – modelling and experiments
PublicationThis paper describes how the refractive index and the absorption of investigated substances change the spectrum of the optical radiation at the output of the fiber-optic Fabry-Pérot interferometer. The modeling of the operation of the interferometer takes into account not only the spectra of the refractive index and the absorption of the medium that is inside the cavity, but also spectra of the refractive indices of the core and...
-
Noise and Electro-Ultrasonic Spectroscopy of Conducting PolymerThick Films
PublicationThick conducting films based on conducting polymer are characterized by DC conductivity and noise in temperature range 10 to 300 K. Conducting polymers could be used e.g. for the top electrode (cathode) in the solid tantalum or niobium capacitors. On the conducting polymer layer the top layer of carbon/graphite and/or silver polymer based pastes is applied in the capacitor technology. Our samples structure consists of conducting...
-
Fiber-optic Fabry-Pérot sensors – modeling versus measurements results
PublicationThis paper describes how parameters of investigated substances and the fiber-optic Fabry-Pérot sensing interferometer affect the spectrum of the optical radiation at the output of the sensor. First, the modeling of the operation of the sensing interferometer was conducted. Most important parameters and effects that were taken into account are: dependences of the refractive indices of the core and the cladding, as well the mode...
-
FIBRE-OPTIC SENSOR FOR SIMULTANEOUS MEASUREMENT OF THICKNESSAND REFRACTIVE INDEX OF LIQUID LAYERS
PublicationIn this paper, we present a fibre-optic sensor for simultaneous measurement of refractive index and thickness of liquid layers. We designed an experimental low-coherence setup with two broadband light sources and an extrinsic fibre-optic Fabry–Pérot interferometer acting as the sensing head. We examined how the refractive index of a liquid film and its thickness affect spectrum at the output of a fibre-optic interferometer. We...
-
Temperature Fiber-Optic Sensor with ZnO ALD Coating
PublicationThis study presents a microsphere-based fiber-optic sensor with a ZnO Atomic Layer Deposition (ALD) coating thickness of 100 nm for temperature measurements. Metrological properties of the sensor were investigated over the temperature range of 100 °C to 300 °C, with a 10 °C step. An interferometric signal is used to control whether the microstructure is whole. Spectrum shift of a reflected signal is used to ascertain changes in...
-
ZnO coated fiber optic microsphere sensor for the enhanced refractive index sensing
PublicationOptical fiber-based sensors are expected to become key components in the control of industrial processes,and the tuning and the enhancement of their sensing properties are crucial for the further developmentof this technology. Atomic Layer Deposition (ALD), a vapor phase technique allowing for the deposition ofconformal thin films, is particularly suited for the deposition of controllable thin films on challenging sub-strates....
-
Tuning transfer function of fiber-optic Fabry-Pérot interferometer via introduction of birefringence in the cavity
PublicationThe study investigates the impact of birefringence exhibited by the cavity material of a fiber-optic Fabry-Pérot interferometer on its transfer function. The theoretical approach to analyze the effect of birefringence in the cavity of a plane Fabry-Pérot interferometer is described. The case of high- and low-finesse interferometer is investigated. It is shown that introduction of a birefringent medium of optimized parameters can...
-
ACUPUNCTURE & ELECTRO-THERAPEUTICS RESEARCH
Journals -
Nanocrystalline diamond sheets as protective coatings for fiber-optic measurement head
PublicationFiber-optic sensors find numerous applications in science and industry, but their full potential is limited because of the risk of damaging the measurement head, in particular, due to the vulnerability of unprotected tips of the fiber to mechanical damage and aggressive chemical agents. In this paper, we report the first use of a new nanocrystalline diamond structure in a fiber-optic measurement head as a protective coating of...
-
Electro-thermal buckling of elastically supported double-layered piezoelectric nanoplates affected by an external electric voltage
PublicationPurpose Thermal buckling of double-layered piezoelectric nanoplates has been analyzed by applying an external electric voltage on the nanoplates. The paper aims to discuss this issue. Design/methodology/approach Double-layered nanoplates are connected to each other by considering linear van der Waals forces. Nanoplates are placed on a polymer matrix. A comprehensive thermal stress function is used for investigating thermal buckling....
-
Analysis of a micro electro-mechanical platform for laparoscopic surgery
PublicationNiniejsza praca ma na celu określenie możliwości zastosowania odkształcalnych urządzeń o kinematyce równoległej w mikro robotycznych przegubach dla igło-laparoskopii. Operacje chirurgiczne przeprowadzane z użyciem narzędzi laparoskopowych o zmniejszonej średnicy nazywane są igłoskopią (z ang. needlescopy). Narzędzia te pozwalają na przeprowadzanie precyzyjnych operacji na stosunkowo niewielkim obszarze i z zaletami mało inwazyjnych...
-
Fiber optic displacement sensor with signal analysis in spectral domain
PublicationIn this paper, a study of a low-coherence fiber optic displacement sensor is presented. The sensor consisted of a broadband source whose central wavelength was either at 1310 nm or 1550 nm, a sensing Fabry-Pérot interferometer operating in reflective mode and an optical spectrum analyzer acting as the detection setup. All these components were connected by a single-mode fiber coupler. Metrological parameters of the sensor were...
-
One-step recovery of REE oxalates in electro-leaching of spent NdFeB magnets
PublicationRecovery of rare-earth elements (REEs) from spent NdFeB magnets is receiving great attention because of high amount of neodymium and potential risk of environmental pollution. In this study, a novel environment-friendly hydrometallurgical route is proposed for efficient recovery of REEs during electrochemical leaching with sulfuric and oxalic acids. With proper adjustment of the electrolyte composition and operating conditions,...
-
Coupled nonlinear Schrödinger equations in optic fibers theory
PublicationIn this paper a detailed derivation and numerical solutions of CoupledNonlinear Schr¨odinger Equations for pulses of polarized electromagnetic wavesin cylindrical fibers has been reviewed. Our recent work has been compared withsome previous ones and the advantage of our new approach over other methods hasbeen assessed. The novelty of our approach lies is an attempt to proceed withoutloss of information within the frame of basic...
-
Microscale diamond protection for a ZnO coated fiber optic sensor
PublicationFiber optic sensors are widely used in environmental, biological and chemical sensing. Due to the demanding environmental conditions in which they can be used, there is a risk of damaging the sensor measurement head placed in the measuring field. Sensors using nanolayers deposited upon the fiber structure are particularly vulnerable to damage. A thin film placed on the surface of the fiber end-face can be prone to mechanical damage...
-
Preparation and Characterization of Microsphere ZnO ALD Coating Dedicated for the Fiber-Optic Refractive Index Sensor
PublicationWe report the fabrication of a novel fiber-optic sensor device, based on the use of a microsphere conformally coated with a thin layer of zinc oxide (ZnO) by atomic layer deposition (ALD), and its use as a refractive index sensor. The microsphere was prepared on the tip of a single-mode optical fiber, on which a conformal ZnO thin film of 200 nm was deposited using an ALD process based on diethyl zinc (DEZ) and water at 100 °C....
-
Insight into (Electro)magnetic Interactions within Facet-Engineered BaFe12O19/TiO2 Magnetic Photocatalysts
PublicationA series of facet-engineered TiO2/BaFe12O19 composites were synthesized through hydrothermal growth of both phases and subsequent deposition of the different, faceted TiO2 nanoparticles onto BaFe12O19 microplates. The well-defined geometry of the composite and uniaxial magnetic anisotropy of the ferrite allowed alternate interfaces between both phases and fixed the orientation between the TiO2 crystal structure and the remanent...
-
Evaluation and start-up of an electro-Fenton-sequencing batch reactor for dairy wastewater treatment
PublicationThis study examined the performance of an integrated wastewater (WW) treatment system, namely an electro-Fenton (EF)-sequencing batch reactor (SBR), for dairy industry WW. The EF process was used as the first stage of the SBR. It degrades bio-refractory compounds via advanced oxidation processes, thereby resulting in the formation of simple biodegradable intermediates. Several factors, including the hydraulic retention time (HRT),...
-
The use of thin diamond films in fiber optic low-coherence interferometers”
PublicationIn this paper we present the use of thin diamond films in fiber-optic low-coherence interferometers. Two kinds of diamond surfaces were used: undoped diamond film and boron-doped diamond film. They were deposited on glass plates as well as silicon layers. A conventionally used mirror was used as a reference layer. Diamond films were deposited using Microwave Plasma Enhanced Chemical Vapour Deposition (μPE CVD) system. Measurements...
-
Fibre Optic Probes For Ophthalmology
Publication -
Fibre-Optic pH Sensor
Publication -
Electro-mechanical shear buckling of piezoelectric nanoplate using modified couple stress theory based on simplified first order shear deformation theory
PublicationThis paper studies the electro-mechanical shear buckling analysis of piezoelectric nanoplate using modified couple stress theory with various boundary conditions.In order to be taken electric effects into account, an external electric voltage is applied on the piezoelectric nanoplate. The simplified first order shear deformation theory (S-FSDT) has been employed and the governing differential equations have been obtained using...
-
Review of the Usefulness of Various Rotational Seismometers with Laboratory Results of Fibre-Optic Ones Tested for Engineering Applications
PublicationStarting with descriptions of rotational seismology, areas of interest and historical field measurements, the fundamental requirements for rotational seismometers for seismological and engineering application are formulated. On the above basis, a review of all existing rotational seismometers is presented with a description of the principles of their operation as well as possibilities to fulfill formulated requirements. This review...
-
Determination of refractive index dispersion using fiber-optic low-coherence Fabry–Perot interferometer: implementation and validation
PublicationWe present the implementation and validation of low-coherence Fabry–Perot interferometer for refractive index dispersion measurements of liquids. A measurement system has been created with the use of four superluminescent diodes with different optical parameters, a fiber-optic coupler and an optical spectrum analyzer. The Fabry–Perot interferometer cavity has been formed by the fiber-optic end and mirror surfaces mounted on a micromechanical...
-
Low-Coherence Interferometric Fiber-Optic Sensors with Potential Applications as Biosensors
PublicationFiber-optic Fabry-Pérot interferometers (FPI) can be applied as optical sensors, and excellent measurement sensitivity can be obtained by fine-tuning the interferometer design. In this work, we evaluate the ability of selected dielectric thin films to optimize the reflectivity of the Fabry-Pérot cavity. The spectral reflectance and transmittance of dielectric films made of titanium dioxide (TiO2) and aluminum oxide (Al2O3) with...
-
Low-Coherence Interferometric Fiber-Optic Sensors with Potential Applications as Biosensors
PublicationFiber-optic Fabry-Pérot interferometers (FPI) can be applied as optical sensors, and excellent measurement sensitivity can be obtained by fine-tuning the interferometer design. In this work, we evaluate the ability of selected dielectric thin films to optimize the reflectivity of the Fabry-Pérot cavity. The spectral reflectance and transmittance of dielectric films made of titanium dioxide (TiO2) and aluminum oxide (Al2O3) with...
-
<title>Correction of fiber optic ion sensor readings using a fiber optic temperature sensor</title>
Publication -
Spatial characterization of H 2: CH 4 dissociation level in microwave ECR plasma source by fibre-optic OES
PublicationSpatially resolved optical emission spectroscopy (SR-OES) was used to investigate microwave activated H2/Ar/CH4 plasma under conditions of the electron cyclotron resonance (ECR). The chemistry and composition of the gas phase were studied using self-designed fibre-optic system with echelle type spectrometer during CVD deposition of polycrystalline diamond. One-dimensional intensity profiles of the main species were collected along...
-
Implementation of SiN thin film in fiber-optic sensor working in telecommunication range of wavelengths
PublicationMirrors are used in optical sensors and measurement setups. This creates a demand for mirrors made of new materials and having various properties tailored to specific applications. In this work, we propose silicon covered with a thin silicon nitride layer as a mirror for near-infrared measurements. SiN layer was deposited on a standard silicon wafer with a Low-Pressure Chemical Vapor Deposition furnace. Then, the created layer...
-
Enhancement of fiber-optic low-coherence Fabry-Pérot interferometer with ZnO ALD films
PublicationIn this paper investigation of the enhanced fiber-optic low coherence Fabry-Pérot interferometer with zinc oxide (ZnO) film deposited by atomic layer deposition (ALD) was presented. Model of the interferometer, which was constructed of single-mode optical fiber with applied ZnO ALD films, was built. The interferometer was also examined by means of experiment. Measurements were performed for both reflective and transmission modes,...
-
Fiber Optic Pulse Sequencers/Desequencers
Publication -
Optical properties of thin TiO2 film deposited on the fiber optic sensor head
PublicationThe presented study was focused on investigation of the titanium dioxide (TiO2) thin film deposited on the fiber tip. The intention of this investigation was using TiO2 film in the construction of the optical fiber sensor head. In the demonstrated construction TiO2 thin layer was deposited on the tip of a commonly used telecommunication single mode optical fiber (SMF-28) by means of the Atomic Layer Deposition (ALD). Thickness...
-
Application of Thin ZnO ALD Layers in Fiber-Optic Fabry-Pérot Sensing Interferometers
PublicationIn this paper we investigated the response of a fiber-optic Fabry-Pérot sensing interferometer with thin ZnO layers deposited on the end faces of the optical fibers forming the cavity. Standard telecommunication single-mode optical fiber (SMF-28) segments were used with the thin ZnO layers deposited by Atomic Layer Deposition (ALD). Measurements were performed with the interferometer illuminated by two broadband sources operating...
-
Application of thin diamond films in low-coherence fiber-optic Fabry Pérot displacement sensor
PublicationThe novel fiber-optic low coherence sensor with thin diamond films is demonstrated. The undoped and boron-doped diamond films were elaborated by the use of the microwave plasma enhanced chemical vapor deposition (μPE CVD) system. The optical signal from the Fabry–Pérot cavity made with the application of those thin films is sensitive to displacement. The sensor characterization was made in the range of 0–600 μm. The measurements...
-
Doped Nanocrystalline Diamond Films as Reflective Layers for Fiber-Optic Sensors of Refractive Index of Liquids
PublicationThis paper reports the application of doped nanocrystalline diamond (NCD) films—nitrogen-doped NCD and boron-doped NCD—as reflective surfaces in an interferometric sensor of refractive index dedicated to the measurements of liquids. The sensor is constructed as a Fabry–Pérot interferometer, working in the reflective mode. The diamond films were deposited on silicon substrates by a microwave plasma enhanced chemical vapor deposition...
-
Fiber-optic sensors based on microspheres with nanocoatings (Zastosowanie mikrosfer optycznych z cienkowarstwowymi pokryciami w czujnikach światłowodowych)
PublicationTemperature is one of the most important physical quantities. Temperature measurements are used in every field of life, especially electronics, electrical engineering, energy-related fields, including energy source and storage devices. The goal of this dissertation is to design and optimize the microsphere-based fiber-optic sensors construction for measurement of the sensor surrounding medium temperature, including selection of...
-
Fiber optic microsphere with a ZnO thin film for potential application in a refractive index sensor – theoretical study
PublicationOptical fiber sensors of refractive index play an important role in analysis of biological and chemical samples. This work presents a theoretical investigation of spectral response of a fiber optic microsphere with a zinc oxide (ZnO) thin film deposited on the surface and evaluates the prospect of using such a structure for refractive index sensing. A microsphere is fabricated by an optical fiber tapering method on the base of...
-
Application of sol-gel-developed integrated optic devices to biochemical fiber optic sensors based on polarimetric interferometry.
PublicationW pracy omówiono zasady działania sensorów optycznych wykonanych w technologii optyki zintegrowanej i wykorzystujących interferometrię polaryzacyjną. Zaproponowano konstrukcję jednorazowego przetwornika pomiarowego, wykonanego w technologii sol-żel z materiałów hybrydowych, która umożliwia wykorzystanie nieodwracalnych reakcji chemicznych do pomiarów w medycynie, chemii i ochronie środowiska. Omówiono technologię syntezy materiałów...
-
Screw displacement pile shaft deformations measured by vibrating wire and fiber optic systems during a static load test
PublicationThis paper describes a full scale static load test performed on a 400 mm diameter screw displacement pile equipped with four different strain measuring systems. Three types of vibrating wire strain gauges (VWSG) were used: global - retrievable, local attached to steel pipe and local concrete embedded. The fourth system was distributed fiber optic sensors based on Rayleigh back scattering (DFOS) - three in the pile cross section....