Search results for: PASSIVE FLUX SAMPLER
-
The home-made in situ passive flux sampler for the measurement of monoterpene emission flux: preliminary studies
PublicationThe paper presents the construction and metrological characteristics of the home-made in situ passive flux sampler, an analytical tool representing small-scale emission chambers working in situ and passively sampling analytes from the gaseous phase. The sorption element was a cylindrical container made of stainless steel net, packed with a carbon sorbent bed-graphitized charcoal, Carbograph 4 (35/50mesh). The recommended working/exposure...
-
The miniaturised emission chamber system and home-made passive flux sampler studies of monoaromatic hydrocarbons emissions from selected commercially-available floor coverings
PublicationThe estimation of the emission rate of organic compounds released from various types of indoor materials can be performed using stationary environmental test chambers (ETC) classified as ex-situ methods or small-scale portable analytical devices based on the use of passive technique at the stage of analytes sampling from the gaseous phase (in-situ methods). The paper presents results of emissions of selected organic compounds from...
-
Calibration of the Chemcatcher passive sampler for the monitoring of priority organic pollutants in water
PublicationNa Univeristy of Portsmouth (UK) opracowano próbnik pasywny typu Chemcatcher, który może być stosowany do długotrwałego monitoringu organicznych zanieczyszczeń wody. Na działanie wszystkich próbników pasywnych wpływ mają warunki środowiskowe takie jak np. ruch wody czy temperatura. Przed użyciem próbnika Chemcatcher w badaniach polowych wymagana więc była wcześniejsza kalibracja w laboratorium. Przedstawiono wyniki serii doświadczeń...
-
Effect of housing geometry on the performance of Chemcatcher passive sampler for the monitoring of hydrophobic organic pollutants in water
PublicationZaprojektowano nową obudowę próbnika typu Chemcatcher, tzw. próbnik typu Chemcatcher drugiej generacji. Większość badań kalibracyjnych przeprowadzono stosując próbnik typu Chemcatcher pierwszej generacji. Dlatego zbadano wpływ obudowy próbnika typu Chemcatcher na jego działanie.
-
Small-scale passive emission chamber for screening studies on monoterpene emission flux from the surface of wood-based indoor elements
PublicationAnalysis of literature data published in the last fewyears leads to the conclusion that in the process of assessment of emission flux of organic compounds emitted from different types of equipment and finishing materials, new types of devices, among which small-scale passive emission chambers for the performance of in-situ research are designed and applied on a larger scale. These devices can be successfully used for the assessment...
-
Miniaturized Passive Emission Chambers for In Situ Measurement of Emissions of Volatile Organic Compounds
PublicationThe results of many different studies have demonstrated unequivocally that the quality of indoor air is often much worse than that of atmospheric air. The presence of dangerous chemical compounds in indoor air can have an adverse impact on human health and cause numerous diseases of the respiratory and circulatory systems. Such harmful chemicals get into indoor air as a result of their emission from building and indoor materials....
-
Application of passive sampling technique in monitoring research on quality of atmospheric air in the area of Tczew, Poland.
PublicationThis paper presents the results of atmospheric air quality research in Tczew (adjacent to the Vistula River) on the content of BTEX compounds. Analytical procedure applied during the sampling of the analytes from the air used the passive sampling technique (diffusive passive sampler, Radiello®). For determination of BTEX compounds in atmospheric air, two-stage thermal desorption technique combined with gas chromatography (TD-GC-FID)...
-
Miniaturized passive emission test chamber for in-situ measurement of emissions of organic compounds
PublicationThe results of many different studies have demonstrated unequivocally that the quality of indoor air is often much worse than that of atmospheric air (outdoor). One of the main groups of chemical compounds present in indoor air, with proven harmfulness to health,are volatile organic compounds (VOCs). VOCs present indoor comprise a wide variety of hydrocarbons and hydrocarbons derivatives including aliphatic, aromatics, alkylbenzens,...
-
Application of passive sampling techniques as a usable tool in the field of environmental quality monitoring
PublicationAnalysis of literature data published for the past 20 years leads to the conclusion, that passive sampling technique has been developing very quickly and is commonly used in the field of monitoring pollutants in air, water and soil environment. The popularity of application of passive sampling techniques in analytical and environmental chemistry results from its many advantages e.g.: Simplicity in use, low costs of exploitation,...
-
Unconventional and user-friendly sampling techniques of semi-volatile organic compounds present in an indoor environment: An approach to human exposure assessment
PublicationThe commonly applied solutions used to assess the potential risk of human exposure to semi-volatile organic compounds (SVOCs) are based on the investigation of biological samples collected in an invasive or non-invasive manner. For SVOCs, which are typically introduced to humans through the respiratory system, dermal adsorption, or digestive system, sampling solutions generally used in the indoor environments are classified as...
-
Heat transfer and pressure drop characteristics of the silicone-based plate heat exchanger
PublicationThe paper presents an experimental investigation of a silicone based heat exchanger, with passive heat transfer intensification by means of surface enhancement. The main objective of this paper was to experimentally investigate the performance of a heat exchanger module with the enhanced surface. Heat transfer in the test section has been examined and described with precise measurements of thermal and flow conditions. Reported...
-
Heat transfer intensification by enlarged surface roughness in the plate heat exchanger
PublicationIn the paper an experimental analysis of passive heat transfer intensification technique employed in the case of the plate heat exchanger is presented. The passive intensification was obtained by a modification of the heat transfer surface. The roughness of surface was increased by a use of glass micro-beads. Single-phase convective heat transfer in the water-water system was studied. The experiment was accomplished in two stages....
-
Thermodynamic and geometrical characteristics of mixed convection heat transfer in the shell and coil tube heat exchanger with baffles
PublicationThe article presents passive heat transfer enhancement method in the form of baffles to increase the energy efficiency of the shell coil heat exchanger. Conducted literature review shows that, despite numer- ous studies, there is little work on the intensification of heat transfer at the shell side. Most of the work focuses on the impact of geometrical parameters of the coil itself. This article successfully proves that it is possible...
-
Effect of surface roughness on thermal-hydraulic characteristics of plate heat exchanger
PublicationIn the paper the experimental analysis of passive heat transfer intensification in the case of modeled plate heat exchanger is conducted. The plate heat exchanger is chosen for the analysis because this kind of heat exchangers could be prospectively applied in the ORC systems, however other areas or application are equally possible. The experimental setup was assembled at the Department of Energy and Industrial Apparatus of Gdansk...
-
Ionic Liquid Assisted Dissolution of Dissolved Organic Matter and PAHs from Soil Below the Critical Micelle Concentration
PublicationIncreased use and production of ionic liquids (ILs) may result in emissions into the environment. Particularly vulnerable are industrial areas and landfills where ILs are utilized and ultimately disposed of. This study investigates how IL contamination can affect soil properties and the sorption of pre-existing contaminants. The commonly used IL 1-methyl-3-octyl imidazolium chloride ([OMIM][Cl]) was added at various quantities...
-
The effect of pre-hydrogen charging on corrosion behaviour of superduplex stainless steel welded joints
PublicationThe paper presents results of research undertaken to determine the influence of hydrogen on passivity and corrosion resistance of 2507 super duplex stainless steel welded joints. Butt welded joints were made with low heat input using flux corded arc welding (FCAW) method. Coupons of 5.0 x 5.0 mm were cut from the welded joints containing weld metal (WM), heat affected zone (HAZ) and parent metal (PM). Hydrogen was introduced...
-
Flux
Journals -
Experimental investigations on heat transfer enhancement in shell coil heat exchanger with VARIABLE Baffles GEOMETRY
PublicationThe paper presents the possibility of using passive intensification of heat transfer in the form of baffles to increase the energy efficiency of the shell and coil heat exchanger. The experiment was carried out by using a modular coil heat exchanger in the form of an electric heater. Water was used as a working fluid with constant thermal-flow parameters at the inlet of the module. It should be noted that experiments were made...
-
Dynamics of Field Line Mappings in Magnetic Flux Tubes
PublicationWe study the topological constraints on the dynamics of magnetic field lines in flux tubes. Our approach is based on the application of the topological invariant: fixed point index. We consider periodic flux tubes and find various restrictions on the field lines that come from the sequence of fixed point indices of iterations. We also analyze the case of a tube with a cylindrical obstacle, deducing some special dynamical properties...
-
Inspection of Gas Pipelines Using Magnetic Flux Leakage Technology
PublicationMagnetic non-destructive testing methods can be classified into the earliest methods developed for assessment of steel constructions. One of them is the magnetic flux leakage technology. A measurement of the magnetic flux leakage is quite commonly used for examination of large objects such as tanks and pipelines. Construction of a magnetic flux leakage tool is relatively simple, but a quantitative analysis of recorded data is a...
-
The flux compression generator load parameters selection
PublicationComputer simulation results of the flux compression generator (FCG) loaded with an inductor has been presented in this paper. Simulation research has been performed in order to select the parameters of FCG load coil properly. The influence of the load inductance and resistance on the current gain factor and the magnetic field energy accumulated in a load coil has been investigated.
-
A device for measuring heat flux on a rocket skin surface
PublicationA novel method for measuring heat flux on a surface is presented. It is an extensive upgrade of currently known heat flux sensors used mostly in civil engineering. As the thermal environment of launchers, especially sounding rocket can have an enormous negative effect on payload, careful considerations have to be taken in the process of preparing insulation. Usually, thermal data provided by the launch vehicle manufacturer is limited...
-
Controlling the europium oxidation state in diopside through flux concentration
PublicationThis paper explores the connection between the H3BO3 flux concentration and the co-existence of Eu2+ and Eu3+ dopants within CaMgSi2O6 crystals (diopside). The samples were synthesised using a solid-state synthesis method under varying atmospheric conditions, including oxidative (air), neutral (N2), and reductive (H2/N2 mixture) environments. Additionally, some materials underwent chemical modification by partially substituting...
-
Assessment of absorbability of seamless flux cored wires stored in extreme conditions
PublicationWater absorption tests by gravimetric method of three specimens of seamless rutile flux cored wires for flux cored arc welding were carried out. Examined wires are characterized by varied absorbability (Wg is ranged from 0.03 to 0.11% after 200 h of moisturizing).
-
Passive sampling and/or extraction techniques in environmental analysis: a review
PublicationThe current state-of-the-art of passive sampling and/or extraction methods for long-term monitoring of pollutants in different environmental compartments is discussed in this review. Passive dosimeters that have been successfully used to monitor organic and inorganic contaminants in air, water, sediments, and soil are presented. The application of new approaches to the determination of pollutants at the sampling stage is discussed....
-
Novel adaptive flux observer for wide speed range sensorless control of induction motor
PublicationA new adaptive flux observer of induction motor is presented in the paper. The Lyapunov theory is utilized for derivation of the adaptation law of rotor flux angular speed, which acts as unknown parameter in an augmented induction motor model. In the field weakening region, where stray fluxes are comparable with rotor flux magnitude, the air-gap flux stabilization is proposed. An air-gap flux multiscalar model is derived for stator...
-
Multiscalar Control Based Airgap Flux Optimization of Induction Motor for Loss Minimization
PublicationBased on the induction motor model, considering the core loss resistance that accounts for magnetic characteristic saturation, a speed control approach is devised with an adaptive full-order (AFO) speed observer. The induction motor model analysis is done sincerely in a stationary reference frame. The control approach incorporates a flux reference generator designed to meet optimal operational circumstances and a nonlinear speed...
-
Nonlinear control of five phase induction motor with synchronized third harmonic flux injection
PublicationThe paper deals with the novel control system for five phase induction motor (IM) that enables the injection of the rotor flux 3rd harmonic component. Two multiscalar models are transformed from the 1-1 and 2-2 vector models developed in the 1st and 3rd harmonic planes. Based on the obtained multiscalar models the synthesis of dual multiscalar control is established. The obtained two multiscalar control systems can independently...
-
Passive Methods in Heat Transport
e-Learning Courses -
Effects of Storing Flux-Cored Wires under Various Conditions
PublicationWelding processes involving the use of flux-cored wires are becoming increasingly popular, particularly in shipbuilding as well as in off-shore and civil engineering. The article presents characteristics of the welding process, its areas of application as well as advantages and disadvantages (e.g. necessity of ensuring appropriate conditions for the storage of filler metal wires). The satisfaction of quality-related requirements...
-
Application of Passive Samplers in Monitoring of Organic Constituents of Air
PublicationThe principles of passive dosimetry, which has been known for over 100 years, are finding an ever increasing use in analytical practice and are being used as a convenient technique for isolation and enrichment of analytes from various environmental media. Due to its simplicity, a variety of designs, as well as the possibility of using a number of different final determination techniques, passive dosimetry has been applied in...
-
The passive operating mode of the linear optical gesture sensor
PublicationThe study evaluates the influence of natural light conditions on the effectiveness of the linear optical gesture sensor, working in the presence of ambient light only (passive mode). The orientations of the device in reference to the light source were modified in order to verify the sensitivity of the sensor. A criterion for the differentiation between two states - "possible gesture" and "no gesture" - was proposed. Additionally,...
-
Rotor-Flux Vector based Observer of Interior Permanent Synchronous Machine
PublicationThe sensorless control system of the interior permanent magnet machine is considered in this paper. The control system is based on classical linear controllers. In the machine, there occurs non-sinusoidal distribution of rotor flux together with the slot harmonics, which are treated as the control system disturbances. In this case, the classical observer structure in the (d-q) is unstable for the low range of rotor speed resulting...
-
Preliminary studies of seamless flux cored wires stored in extreme conditions
PublicationIn the paper preliminary experimental studies of flux cored wires moisturized under controlled conditions are described. Three seamless wires of different grades have been placed in environmental chamber and moisturized in extremely adverse conditions (temperature T = 60° C, relative humidity H = 90%) for 240 hours. During this time measurements of weight gain and observations of surface of wires have been carried out. Also diffusible...
-
Measurement of benzene concentration in urban air using passive sampling
PublicationAbstract The concentration of benzene in urban air in theTri-City area of Poland (Gdańsk-Sopot-Gdynia, andTczew) was assessed using diffusive passive samplers (Rad-iello). Samples were collected during a four-year monitoringcampaign (2007-2010) at selected monitoring stations man-aged by the Agency of Regional Air Quality Monitoring inthe Gdańsk Metropolitan Area (ARMAAG) Foundation.The performance of the passive samplers was investigatedin...
-
Exploring the trends in flux-cored arc welding: scientometric analysis approach
PublicationFlux-cored arc welding (FCAW) is a universal group of welding methods in terms of the scope of application and automation possibilities, the share of which in various industries in many countries is still increasing. The paper presents the results of bibliographic analyses (scientometric analysis with the use of VOSviewer, Bibliometrix and CitNetExplorer tools) of a data set of 993 publications indexed in the Web of Science database...
-
Mathemathical model of radial passive magnetic bearing
PublicationIn the article mathematical radial model of passive magnetic bearings to ocean engineering units has been presented. The units application in underwater thrusters should increase propulsion systems durability and gives lower maintenance costs. The rotor of electric motor is hanging in magnetic field taken from radial passive magnetic bearings. However axial direction maintenance must be controlled with electromagnets and their...
-
Reduction of the Velocity Impact on the Magnetic Flux Leakage Signal
PublicationThe velocity effect on the magnetic flux leakage (MFL) signal was investigated in this paper. Experiments were performed for velocity of the MFL tool within the range of 0–2 m/s. The velocity was not constant during each measurement to imitate real operational conditions of the MFL tool. Two components of the leakage were measured, i.e. the tangential to the motion direction (x) and the normal to the investigated surface (z). In...
-
Rotor flux and EEMF observer for interior permanent magnet synchronous machine
PublicationIn recent years, the use of the interior permanent magnet synchronous machine (IPMSM) in various applications has grown significantly due to numerous benefits. Sensors are used to achieve high efficiency and good dynamic response in IPMSM drives but due to their high cost and reduced overall size of the system, sensorless control techniques are preferred. Non-sinusoidal distribution of rotor flux and slot harmonics are present...
-
Influence of passive house technology on time and cost of construction investment
PublicationDue to the changes in the energy standards for housing in Poland there are many concerns. Is the standard required by the regulation achievable and if it is, then at what cost? There are many solutions to construct a building in line with the requirements of passive house technology. They are differentiated by price and time required for implementation. This study is based on the solution proposed by one of Polish companies, offering...
-
Modelling of the Heat Flux Density Distribution for Laser Beam Welding
PublicationGreat interest of the laser beam welding in industry is a new theoretical task, making planning the welding procedure specification and the quality control of welded joints easier. Estimating and calculating the dimensions of a weld pool and temperature distribution near weld mainly concern heat source modelling. In the presented work calculations of welding pool shape and thermal field for cylindrical-powered-normally model of...
-
Augmented speed control scheme of dual induction motors with mutual flux angle control loop
PublicationThis paper proposes an augmented speed control scheme of dual induction motors fed by a five-leg voltage source inverter (VSI) with a common/shared-leg. An additional control loop is proposed here and based on the mutual flux angle – the difference between flux angular positions of the IMs. The main purpose of this research is to minimize the energy losses in the common inverter leg by controlling the mutual flux angle, at equal...
-
Active and Passive Electronic Components
Journals -
Diffusible Hydrogen Control in Flux Cored Arc Welding Process
PublicationOne of the types of hydrogen degradation of steel welded joints is cold cracking. The direct cause of the formation of cold cracks is simultaneous presence of hydrogen, residual stresses and brittle structure. The way of preventing the occurring of degradation is to eliminate at least one of these factors. Practice has shown that the best solution is to control the amount of hydrogen in deposited metal. In this paper an experimental...
-
Interactions using passive optical proximity detector
PublicationIn this paper we evaluated the possible application of a passive, optical sensor as an interface for human-smart glasses interactions. The designed proximity sensor is composed of set of photodiodes and the appropriate hardware and software components. First, experiments were performed for the estimations of such parameters as distance to an object, its width and velocity. Achieved results were satisfactory. Therefore, next, a...
-
passive spice networks from non-passive data
PublicationArtykuł przestawia technike generacji schematow zastepczych w formacie SPICE dla pasywnych układów mikrofalowych. Wynikowy schemat zastepczy ma zagwarantowana pasywnosc. Schematy zastepcze powstaja na podstawie symulacji lub pomiarow w dziedzinie czestotliwosci i moga byc wykorzystane do symulacji w dziedzinie czasu.
-
Passive sampling
PublicationPrzedstawiono możliwości wykorzystania technik pasywnych (opartych na swobodnym ruchu cząsteczek analitu do medium zatrzymującego) w analityce środowiskowej. Omówiono przykłady wykorzystania zarówno organizmów żywych (biomonitoring) jak i urządzeń pasywnych do pobierania próbek analitów z badanego medium (powietrze, woda, gleba).
-
A Wind Energy Conversion System Based on a Generator with Modulated Magnetic Flux
PublicationIn this work, the concept of an energy conversion system for wind turbines based on the modified permanent magnet synchronous generator (PMSG) is presented. In the generator, a pair of three-phase windings is used, one of which is connected in a “star” and the second in a “delta” configuration. At the outputs of both windings, two six-pulse uncontrolled (diode) rectifiers are included. These rectifiers are mutually coupled by a...
-
Buck-Boost Inverters with Symmetrical Passive Four-terminal Networks
PublicationAlternating Voltage Inverters (Converters) supplied by low-voltage sources DC (ex. fuel cell, photovoltaic cell) are most frequently realized on the basis of the three fundamental topologies: a) PWM voltage inverter with boost-converter" system, b) PWM voltage inverter with transformed converter DC/DC in the ,,boost-converter" system, c) PWM current converter. However none of these solutions is claimed to be the best and dominant...
-
AUGMENTATION OF THE CRITICAL HEAT FLUX IN WATER-Al2O3, WATER-TiO2 AND WATER-Cu NANOFLUIDS
PublicationThe main aim of the proposed study is therefore recognition of the phenomena accompanying nucleate boiling crisis of selected nanofluids during boiling on horizontal tubes of various outside diameters. Of particular interest is impact of contact angle and tube diameter on the value of critical heat flux. The results obtained should give more light on the nature of nucleate boiling crisis and will serve as a basis for future theoretical...