Filters
total: 870
-
Catalog
Search results for: TASTE SENSOR, POENTIOMETRIC SENSOR
-
Evaluation of relative humidity effects on interfacial impedance at inter-coat interfaces.
PublicationSpektroskopia impedancyjna została zastosowana jako metoda niedestrukcyjna do oceny adhezji pomiędzy polimerowymi warstwami w ochronnym systemie powłokowym. Celem badań było stwierdzenie wpływu zewnętrznej wilgotności na impedancję międzyfazową. Badano system ochrony stosowany do ochrony samochodów. Zastosowano nowy sensor do detekcji rozwarstwienia i akumulacji wody w obszarze międzyfazy. Elektrody stanowią paski przewodzącego...
-
Measurements of the mechanical system properties of "SpeedLine magnetic" ultra-fast robot prototype for IML labeling
Open Research DataThe mechanical system tests of the high-speed IML labeling robot "SpeedLine Magnetic" were carried out in order to analyze the effects of the drive system's operating parameters on vibration and noise.
-
Micoroalgae bloom detected in Southern Baltic Sea on 25.07.2014
Open Research DataThe GeoTIFF image presents detected microalgae bloom observed in the Baltic Sea on 25.07.2014. The image has been obtained from the raw AVHRR sensor bands 1 (0.58-0.68 μm) and 2 (0.725-1.0 μm). The resulting single-band raster has been masked to remove all pixels outside of the Baltic Sea region. Pixel values between -0.2 and -0.23 depict progressively...
-
Application of fiber optic sensors using Machine Learning algorithms for temperature measurement of lithium-ion batteries
PublicationOptical fiber sensorsusing low-coherence interferometry require processing ofthe output spectrum or interferogramto quickly and accurately determine the instantaneous value of the measured quantity, such as temperature.Methods based on machine learning are a good candidate for this application. The application of four such methods in an optical fiber temperature sensoris demonstrated.Using aZnO-coated...
-
Fluctuation-Enhanced Sensing with Organically Functionalized Gold Nanoparticle Gas Sensors Targeting Biomedical Applications
PublicationDetection of volatile organic compounds is a useful approach to non-invasive diagnosis of diseases through breath analysis. Our experimental study presents a newly developed prototype gas sensor, based on organically-functionalized gold nanoparticles, and results on formaldehyde detection using fluctuation-enhanced gas sensing. Formaldehyde was easily detected via intense fluctuations of the gas sensor’s resistance, while the cross-influence...
-
Nitrogen dioxide sensing properties of PEDOT polymer films
PublicationThis work presents a simple and fully electrochemical route for the polymerization of poly(3,4-ethylenedioxytiophene) (PEDOT) films for fabricating a NO2 gas sensor prepared by electropolymerization of 3,4-Ethylenedioxythiophene (EDOT) monomer in lithium perchlorate/acetonitrile solution. The main aim of this study is to determine the sensing properties of conductive polymer at elevated temperatures. The effects of the humidity,...
-
Scalable Measurement System for Multiple Impedance Gas Sensors
PublicationAuthor proposes scalable architecture of the measurement system for gas sensor with impedance dependance of the gas concentration. The main part of the system is a single-board impedance analyser. The number of analysers working in parallel can be configured according to specific application. The system is controlled by a single computer which organises the measurement cycle and store the acquired measurement data. The system is...
-
The silver layers in fiber-optic sensors
PublicationIn this paper a method of application of the silver layers on the surface of an optical fiber was proposed. The optical properties and surface quality of the silver layer was examined by optical microscopy. The reflection and transmission of the sample were investigated. To evaluate the silver mirror it was placed in a fiber optic Fabry-Perot interferometer and the quality of the spectra was analyzed. The commercial mirror was...
-
Multichannel Human Body Communication
PublicationHuman Body Communication is an attractive alternative for traditional wireless communication (Bluetooth, ZigBee) in case of Body Sensor Networks. Low power, high data rates and data security makes it ideal solution for medical applications. In this paper, signal attenuation for different frequencies, using FR4 electrodes, has been investigated. Performance of single and multichannel transmission with frequency modulation of analog...
-
Magnetic field gradient as the most useful signal for detection of flaws using MFL technique
PublicationThe magnetic flux leakage (MFL) technique is extensively used for detection of flaws as well as for evaluation of their dimensions in ferromagnetic materials. However, proper analysis of the MFL signal is hindered by the MFL sensor velocity causing distortions of this signal. Traditionally measured components of the MFL signal are particularly sensitive to the scanning velocity. In this paper, an another signal – the gradient of...
-
Electronic Noses and Electronic Tongues
PublicationChapter 7 reports the achievements on the field of artificial senses, such as electronic nose and electronic tongue. It examines multivariate data processing methods and demonstrates a promising potential for rapid routine analysis. Main attention is focused on detailed description of sensor used, construction and principle of operation of these systems. A brief review about the progress in the field of artificial senses and future trends...
-
Creating Dynamic Maps of Noise Threat Using PL-Grid Infrastructure
PublicationThe paper presents functionality and operation results of a system for creating dynamic maps of acoustic noise employing the PL-Grid infrastructure extended with a distributed sensor network. The work presented provides a demonstration of the services being prepared within the PLGrid Plus project for measuring, modeling and rendering data related to noise level distribution in city agglomerations. Specific computational environments,...
-
Zastosowanie metod eksploracji danych do analizy odpowiedzi czujników gazu
PublicationZagadnienia poruszane w niniejszej rozprawie dotyczą zastosowania metod eksploracji danych do analizy odpowiedzi czujników gazu, umożliwiających poprawną identyfikację składu mieszaniny gazowej w elektronicznych systemach rozpoznawania gazu. Elektroniczne systemy rozpoznawania gazu to urządzenia wykorzystujące czujniki gazu oraz odpowiednio dobrane metody analizy danych pomiarowych, zdolne do określenia składu mierzonej mieszaniny...
-
Magnetic field microsensor based on GaAs MESFET
PublicationA novel concept of the drain separation design in a horizontally-split-drain GaAs MAGFET sensor, based on epitaxial layer growth, was developed. Proper choice of GaAs/AlAs/GaAs epitaxial layer sequence provided good electrical isolation between the drain regions. The measured leakage current between the drain regions was in the range of nA for up to 2V drain voltage bias difference. Performed analytical and numerical calculations...
-
Wybrane aspekty oceny jakości produktów żywnościowych
PublicationPrzedstawiono wybrane aspekty oceny jakości produk tów żywnościo- wych: pojęcie jakości, wybrane metody oceny jakości ze szczególnym uwzględ- nieniem sztucznych potencjometrycznych sensorów sma ku składających się z szeregu elektrod typu ISE (Ion Selective Electrodes ) oraz ASSE (All Solid State Electrodes). Omówiono działanie sztucznych sensorów smaku. Przedstawiono 10 potencjometryczny sensor wprowadzony do obrotu hand lowego....
-
Monitoring of single-side lap grinding with electroplated tools
PublicationThe results presented in the paper show that utilising microphones as audible sound sensors is a suitable approach for monitoring a single-side lap grinding process due to the low levels of noise generated by the drives of a machine tool. The results confirm that sound signal analysis is a feasible and relatively simple method to monitor a lap grinding process with the use of an audible sound sensor. Proposed method can be used...
-
Tuning transfer function of fiber-optic Fabry-Pérot interferometer via introduction of birefringence in the cavity
PublicationThe study investigates the impact of birefringence exhibited by the cavity material of a fiber-optic Fabry-Pérot interferometer on its transfer function. The theoretical approach to analyze the effect of birefringence in the cavity of a plane Fabry-Pérot interferometer is described. The case of high- and low-finesse interferometer is investigated. It is shown that introduction of a birefringent medium of optimized parameters can...
-
The influence of small amount of substances present in tissue on the optical spectrum of immunosuppressive drug
PublicationIn this paper, we describe how commonly present in tissue substances - sodium chloride and glucose - affect the optical spectrum of an immunosuppressive drug (Cyclaid® by Apotex). Prepared samples were investigated using the spectrophotometer in the spectrum range from 250 nm to 1100 nm. The maximum wavelength shift calculated on the basis of measurement results is not bigger than the measurement wavelength step. So, it can be...
-
Badania nad potencjometrycznymi sensorami smaku
PublicationPrzedstwiono badania nad 5-kanałowym sensorem smaku kwasnego, zbudowanym z elektrod z membranami polimerowo - lipidowymi zawierającymi odpowiednie lipidy. Stwierdzono, że sensor ten jest bardzo czuły na zmainy stężenia kwasu cytrynowego, natomiast wykazuje nieco gorszą czułosc na obecnosć kwasu octowego. Stwirdzono dobrą trwałosć membran oraz powtarzalnośc otrzymanych wyników. Wydaje się, że badane układy mogą byc wykorzystane...
-
Post processing and selecting data obtain with parametric sub-bottom profiler SES-2000 Standard during sounding the Gulf of Gdansk
PublicationThe main goal of the paper is to describe the results of sounding the Gulf of Gdansk seabed using a parametric sub-bottom profiler SES-2000 Standard. Quality of obtained during trials data depends inter alia on proper location of antenna to reduce influence of pitch, roll, heave and ship noise (bubbles from propeller and a hull flow, vibration from main engine and peripheral devices). Furthermore calibration of complementary units...
-
Inverse Modeling and Optimization of CSRR-based Microwave Sensors for Industrial Applications
PublicationDesign optimization of multivariable resonators is a challenging topic in the area of microwave sensors for industrial applications. This paper proposes a novel methodology for rapid re-design and parameter tuning of complementary split-ring resonators (CSRRs). Our approach involves inverse surrogate models established using pre-optimized resonator data as well as analytical correction techniques to enable rapid adjustment of geometry...
-
Impedimetric sensing of α-amino acids driven by micro-patterned 1,8-Diazafluoren-9-one into titania- boron- doped maze-like nanocarbons
PublicationThe development of impedimetric, non-faradaic label-free sensors for the detection of α-amino acids constitutes a trailblazing technology for the fast and inexpensive quantification of such biomarkers. Since α-amino acids, such as glycine and sarcosine, are basic constituents in biological processes, a variation in their concentration may be an indicator of cardiovascular diseases and metabolic disorders or neurological conditions....
-
A method to monitor urinary carbon dioxide in patients with septic shock
PublicationSevere sepsis and septic shock are life-threatening conditions with mortality rates exceeding 31% (Levy et al., 2012) [1]. Septicemia was the most expensive US hospital condition in 2011 (Torio and Andrews, 2006)[2]. Urinary carbon dioxide may provide rapid, clinically useful information about a patient’s status, empowering physicians to intervene earlier and improve septic shock mortality. The objective of this paper is to validate...
-
Low-Coherence Interferometric Fiber-Optic Sensors with Potential Applications as Biosensors
PublicationFiber-optic Fabry-Pérot interferometers (FPI) can be applied as optical sensors, and excellent measurement sensitivity can be obtained by fine-tuning the interferometer design. In this work, we evaluate the ability of selected dielectric thin films to optimize the reflectivity of the Fabry-Pérot cavity. The spectral reflectance and transmittance of dielectric films made of titanium dioxide (TiO2) and aluminum oxide (Al2O3) with...
-
Low-Coherence Interferometric Fiber-Optic Sensors with Potential Applications as Biosensors
PublicationFiber-optic Fabry-Pérot interferometers (FPI) can be applied as optical sensors, and excellent measurement sensitivity can be obtained by fine-tuning the interferometer design. In this work, we evaluate the ability of selected dielectric thin films to optimize the reflectivity of the Fabry-Pérot cavity. The spectral reflectance and transmittance of dielectric films made of titanium dioxide (TiO2) and aluminum oxide (Al2O3) with...
-
Assessment of Electronic Sensing Techniques for the Rapid Identification of Alveolar Echinococcosis through Exhaled Breath Analysis
PublicationHere we present a proof-of-concept study showing the potential of a chemical gas sensors system to identify the patients with alveolar echinococcosis disease through exhaled breath analysis. The sensors system employed comprised an array of three commercial gas sensors and a custom gas sensor based on WO3 nanowires doped with gold nanoparticles, optimized for the measurement of common breath volatile organic compounds. The measurement...
-
Comparative study on the effectiveness of various types of road traffic intensity detectors
PublicationVehicle detection and speed measurements are crucial tasks in traffic monitoring systems. In this work, we focus on several types of electronic sensors, operating on different physical principles in order to compare their effectiveness in real traffic conditions. Commercial solutions are based on road tubes, microwave sensors, LiDARs, and video cameras. Distributed traffic monitoring systems require a high number of monitoring...
-
Kontrola procesowa za pomocą technik czujnikowych nowych metod selektywnego oczyszczania biogazu ze związków uciążliwych zapachowo
PublicationW obecnym czasie dużą uwagę zwraca się na opracowanie efektywnej technologii oczyszczania biogazu do gazu wysokometanowego. Głównym celem rozprawy doktorskiej było opracowanie ekonomicznie opłacalnych absorbentów do efektywnego oczyszczania strumieni biogazu z substancji uciążliwych zapachowo. Procesy absorpcji fizycznej prowadzono z wykorzystaniem zaprojektowanych i otrzymanych dotąd jeszcze nie publikowanych sorbentów na bazie...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 0 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 40 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 30 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 200 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 20 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 80 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 170 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 20 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 140 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 130 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 50 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 120 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 110 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 130 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 90 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 120 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 200 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 170 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 90 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 180 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 140 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 60 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...