Filters
total: 5235
-
Catalog
- Publications 4162 available results
- Journals 32 available results
- Conferences 1 available results
- People 48 available results
- Projects 3 available results
- Research Equipment 1 available results
- e-Learning Courses 26 available results
- Events 1 available results
- Open Research Data 961 available results
displaying 1000 best results Help
Search results for: METAMATERIALS (MTMS), GAIN ENHANCEMENT, LOW IMPEDANCE MTM, MTM LENS, PLANAR ANTENNAS, ZIM
-
Low-Temperature Requirements for Bitumen in Central East European Road Construction
PublicationThe paper presents the proposition of special assessment of lowtemperature requirements for bitumens in the region of Central and Eastern Europe where there is a moderate transitional area from sea to the continental type of climate. The results of the research program conducted on the road neat bitumens, Styrene-Butadiene-Styrene polymer and polymer-rubber modified bitumen, and multigrade bitumen types were presented and discussed....
-
Broadband/Dual-band Metal-Mountable UHF RFID Tag Antennas: A Systematic Review. Taxonomy Analysis, Standards of Seamless RFID System Operation, Supporting IoT implementations, Recommendations and Future Directions
PublicationThe employment of broadband/dual-band ultra-high frequency (UHF) radio frequency identification (RFID) tag antennas contributes to the growth of RFID technology, with many potential implications, such as the increase of international trade, and reducing costs thereof. This study presents all reported articles on RFID tags for metal objects that can work seamlessly across different countries. Moreover, it addresses all available...
-
Linear impedance of strontium–borate glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe linear electrcial properties of strontium–borate glass was measured by impedance spectroscopy method.
-
Enhancement of ibuprofen solubility and skin permeation by conjugation with l-valine alkyl esters
Publication -
Enhancement of second harmonic generation in nanocrystalline SiC films based natural microcavities
Publication -
Symmetry-Dependent Vibrational Circular Dichroism Enhancement in Co(II) Salicylaldiminato Complexes
Publication -
Safety enhancement using 3D multibeam sonar imaging in shallow waters areas
PublicationSonary wielowiazkowe wykorzystanee byc moga do poprawy bezpieczenstwa zeglugi na obszarach wod plytkich. Dzieki istotnej poprawie rozdzielczosci horyzontalnej i wertykalnej pomiarow zastosowane byc moga do obrazowania wod plytkich szczegolnie niebezpiecznych pod wzgledem nawigacyjnym.
-
The Effects of Resisted Post-Activation Sprint Performance Enhancement in Elite Female Sprinters
Publication -
Heat transfer enhancement, flow visualization and friction characteristics in rib-roughened channels
PublicationW pracy przedstawiono wyniki badań eksperymentalnych związanych z intensyfikacją wymiany ciepła w kanałach wyposażonych w żebra, które poprawiają warunki przejmowania ciepła od ścianki do przepływającego medium. W badaniach wykorzystano system PIV oraz termografię ciekłokrystaliczną.
-
Emotional enhancement of memory effect in obstructive sleep apnea syndrome - preliminary results
Publication -
Enhancement of thermal stability of multiwalled carbon nanotubes via different silanization routes
Publication -
THE INTERNATIONAL COMPETITIVENESS OF EUROPEAN UNION COUNTRIES AND STRATEGIES FOR ITS ENHANCEMENT: A TAXONOMIC ANALYSIS
PublicationThe aim of this article is to identify clusters of countries with similar levels of competitiveness among the EU-27 countries and to identify for each of the 27 EU countries the path to growth in competitiveness. The taxonomic cluster analysis conducted confirms the hypothesis that the European Union is an area with a high differentiation in terms of levels of competitiveness. The analysis shows that the strategy to increase competitiveness...
-
Evaluation of Sound Enhancement in Mobile Device Using Virtual Bass Synthesiss Algorithm
PublicationAn experiment conducted to validate possibility of use virtual bass synthesis (VBS) algorithm in a portable computer is presented. The subjective listening tests based on the procedure of pairwise comparison between VBS, based on the so-called missing fundamental phenomenon, and standard bass boost technique are employed. The evaluation was carried out in two types of conditions: in a professional listening room and employing an...
-
Low grade serous carcinoma - Female, 45 - Tissue image [4100730020132541]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Low grade serous carcinoma - Female, 45 - Tissue image [4100730020134161]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
In-situ odd random phase electrochemical impedance spectroscopy study on the electropolymerization of pyrrole on iron in the presence of sodium salicylate – The influence of the monomer concentration
PublicationIn this work, the potentiostatic electropolymerization of polypyrrole (PPy) on iron in aqueous solution of sodium salicylate and pyrrole is studied in situ by odd random phase electrochemical impedance spectroscopy (ORP-EIS). The influence of the pyrrole concentration on the electrosynthesis process is investigated. The ORP-EIS technique ensures a reliable analysis of the PPy electrosynthesis on iron by means of an advanced data...
-
Quality assessment of low voltage surge arresters
PublicationUsers expect reliable operation of the surge arrester during overvoltages, which may originate from a switching process or a lightning discharge. The necessary conditions to guarantee these expectations are: appropriate construction of the surge arrester, its production being maintained in accordance with technical standards, and a positive results of the type test (as well routine and acceptance tests). The recipient, especially...
-
Mucinous cystic neoplasm with low grade dysplasia - Female, 65 - Tissue image [11010630088562941]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mucinous cystic neoplasm with low grade dysplasia - Female, 65 - Tissue image [3300730069454481]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mucinous cystic neoplasm with low grade dysplasia - Female, 65 - Tissue image [1101063008856651]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mucinous cystic neoplasm with low grade dysplasia - Female, 65 - Tissue image [3300730069451541]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mucinous cystic neoplasm with low grade dysplasia - Female, 65 - Tissue image [11010630088568781]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mucinous cystic neoplasm with low grade dysplasia - Female, 65 - Tissue image [1101063008856751]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mucinous cystic neoplasm with low grade dysplasia - Female, 65 - Tissue image [11010630088561471]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mucinous cystic neoplasm with low grade dysplasia - Female, 65 - Tissue image [3300730069451791]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mucinous cystic neoplasm with low grade dysplasia - Female, 65 - Tissue image [11010630088566441]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 64 - Tissue image [127063001269211]
Open Research DataThis is the histopathological image of OTHER AN UNSPECIFIED FEMALE GENITAL ORGANS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 64 - Tissue image [1270630012698451]
Open Research DataThis is the histopathological image of OTHER AND ILL-DEFINED SITES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 64 - Tissue image [3300730069467771]
Open Research DataThis is the histopathological image of OTHER AND ILL-DEFINED SITES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 64 - Tissue image [1270630012691521]
Open Research DataThis is the histopathological image of OTHER AND ILL-DEFINED SITES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Simple 60 GHz Switched Beam Antenna for 5G Millimeter-Wave Applications
PublicationA new 60 GHz band single-input switched beam antenna is proposed for the fifth-generation (5G) millimeter-wave network applications. The presented design is capable of electronically switching the main beam in two different directions via a proposed microstrip-line-to-slotline single-pole dual-throw (SPDT) switch based on commercially available p-i-n diodes. The antenna is fabricated in a low-cost printed circuit board process...
-
A strategy of minimal torque modifications in a question of actuation strategy for an over-actuated system of a planar walking robot
PublicationPraca opisuje zagadnienia modelowania i napędzania robotów kroczących. Na pewnych etapach ruchu, konstrukcje takie są układami napędzanymi nadmiarowo (liczba napędów/silników jest większa niż liczba stopni swobody układu). Dzieje się tak z uwagi na więzy jednostronne występujące w układzie. Dla układów płaskich, po pojawieniu się kontaktu koła i odnóża, układ o sześciu stopniach swobody przechodzi w układ o trzech stopniach swobody....
-
Fundamental-harmonic impedance of first-order electrode reactions
Publication -
Determination of electrode impedance by means of exponential chirp signal
Publication -
Application of Dynamic Impedance Spectroscopy to Scanning Probe Microscopy
Publication -
Application of dynamic impedance spectroscopy to atomic force microscopy
Publication -
Impedance Investigations of the Mechanism of Oxygen Evolution on Composite Electrodes
Publication -
Theoretical description of the measuring method of instantaneous impedance spectra
Publication -
Determination of electrode impedance by means of exponential chirp signal.
PublicationPrzedstawiona została nowa metoda pomiaru impedancji elektrodowej. Jako pobudzenie zastosowany został niestacjonarny sygnał napięciowy, którego częstotliwość jest ekspotencjalną funkcją czasu. Zastosowanie zmodyfikowanej któtko-czasowej transformaty Fouriera (STFT) w analizie napięciowego pobudzenia i odpowiedzi prądowej pozwala na otrzymanie widma impedancyjnego.
-
Influence of test procedure on surge impedance of lightning earthings.
PublicationUziemienia systemu ochrony odgromowej powinny być badane prądami o parametrach czasowych podobnych do rejestrowanych podczas wyładowań atmosferycznych.Podano definicję impedancji i warunki jej pomiaru. omówiono pojęcie długości efektywnej uziomu.
-
Impedance measurements of skin layered structure for burns determination.
PublicationW pracy analizowany jest dwuwarstwowy model skóry. Pokazano, że za pomocą wielokrotnych pomiarów immitancyjnych jest możliwe wyznaczenia zarówno parametrów elektrycznych oparzonej skóry jak i geometrycznych. Przedstawiono algorytm estymacji i procedurę pomiarową wyżej wymienionych parametrów.
-
Modular impedance tomograph for shallow soil subsurface investigation.
PublicationW pracy przedstawiono konstrukcję i procedury pomiarowe konfigurowalnego systemu pomiarowego. Konstrukcja systemu oparta jest idei tzw. elektrody aktywnej, która zbudowana jest z wykorzystaniem mikrokontrolera ADuC 812.
-
Impedance matching in dual-frequency induction heating systems
Publication -
Measurement microsystem for high impedance spectroscopy of anticorrosion coatings
PublicationW artykule przedstawiono mikrosystem do pomiarów bardzo dużych impedancji ukierunkowany na identyfikację parametrów powłok antykorozyjnych metodą spektroskopii impedancyjnej. Do wyznaczania składowych ortogonalnych sygnałów pomiarowych zastosowano w nim technikę cyfrowego przetwarzania sygnałów. Pozwoliła ona na uzyskanie szerokiego zakresu częstotliwości pomiarowych, zwłaszcza bardzo niskich, od ćHz, przy zachowaniu prostej konstrukcji...
-
An analysis of a measurement probe for a high impedance spectroscopy analyzer
PublicationW artykule przedstawiono sondę będącą obwodem wejściowym analizatora do spektroskopii wysokoimpedancyjnej. Sonda umożliwia pomiar impedancji jednym zaciskiem uziemnionej w zakresie od 100ohm do 100Gohm. Sonda umożliwia wydzielenie dwóch sygnałów proporcjonalnych do prądu i napięcia na impedancji mierzonej w szerokim zakresie częstotliwosci od 100uHz do 100MHz.Przeprowadzono analizę sondy w której uwzględniono najważniejsze czynniki...
-
Fast impedance measurement method using Laplace transformation
PublicationArtykuł przedstawia metodę pomiaru impedancji wykorzystującą rzeczywisty uskok jednostkowy step jako sygnał pobudzenia i transformację Laplace jako narzędzie analizy sygnału odpowiedzi testowanego obiektu. Metoda jest dedykowana do badania różnych obiektów technicznych (np. powłok antykorozyjnych, czujników gazu, ceramik, tkanek biologicznych itp.) gdy czas pomiaru nie może być długi. Przedstawiona metoda jest znana ale niezbyt...
-
New concept of a measurement probe for high impedance spectrocopy
PublicationArtykuł przedstawia nową koncepcję sondy pomiarowej służącej jako obwód wejściowy analizatora do spektroskopii wysokoimpedancyjnej. Dzięki wykorzystaniu przetwornika prąd na napięcie uzyskano najmniejszy możliwy wpływ pojemności kabli dołączających mierzony obiekt na wynik pomiaru. Przeprowadzono analizę sondy biorąc pod uwagę najważniejsze parametry wpływające na dokładność pomiaru: pojemności pasożytnicze oraz rzeczywiste parametry...
-
An analysis of a measurement probe for a high impedance spectroscopy analyzer
PublicationW artykule przedstawiono sondę będącą obwodem wejściowym analizatora do spektroskopii wysokoimpedancyjnej. Sonda umożliwia pomiar impedancji jednym zaciskiem uziemnionej w zakresie od 100ohm do 100Gohm. Sonda umożliwia wydzielenie dwóch sygnałów proporcjonalnych do prądu i napięcia na impedancji mierzonej w szerokim zakresie częstotliwości od 100uHz do 100MHz.Przeprowadzono analizę sondy w której uwzględniono najważniejsze czynniki...
-
Application of dynamic impedance spectroscopy to atomic force microscopy
PublicationMikroskopia sił atomowych jest uniwersalną techniką obrazowania powierzchni podczas gdy spektroskopia impedancyjna jest fundamentalną metodą charakteryzowania właściwości elektrycznych materiałów. Z powyższego względu użyteczne jest połączenie powyższych technik dla uzyskania przestrzennego rozkładu wektora impedancji. W pracy autorzy proponują nowe podejście polegające na połączeniu multiczęstotliwościowego pomiaru impedancyjnego...
-
On-line Impedance Monitoring of Direct Methanol Fuel Cell
PublicationW niniejszej pracy została przedstawiona technika badawcza Dynamiczna Elektrochemiczna Spektroskopia Impedancyjna w obszarze badań ogniw paliwowych. Obiektem badań było ogniwo paliwowe zasilane bezpośrednio metanolem. Badano on-line wpływ zmian warunków pracy na globalną impedancję ogniwa. Podczas pomiarów zmianie ulegała temperatura, natężenia przepływu utleniacza oraz obciążenie.