Search results for: PERFUSION COMPUTED TOMOGRAPHY
-
Using the ultrasonic tomography method to study the condition of wooden beams from historical buildngs
PublicationThe need to evaluate the integrity of wooden structural elements is constantly increasing. Non-destructive methods are becoming more popular in this field of research. One type of non-destructive testing is the ultrasonic imaging method, which allows the analysis of internal wood structures without disturbing their state and integrity. In this study, we are interested in assessing the effect of wood condition on the ultrasound...
-
Tome-lapse X-ray tomography imaging of flow patterns in versatile silo model
PublicationThe paper introduces a new versatile silo model that was especially designed for in situ X-ray tomography studies of silo discharge for various flow conditions, namely concentric and eccentric. The presented work focuses on organic granular materials where low fraction of short-grain white rice is mixed with spheroidal sorghum particles. The high-quality tomography images combined with adequate image processing strategy allows...
-
A compartment model of alveolar–capillary oxygen diffusion with ventilation–perfusion gradient and dynamics of air transport through the respiratory tract
PublicationThis paper presents a model of alveolar–capillary oxygen diffusion with dynamics of air transport through the respiratory tract. For this purpose electrical model representing the respiratory tract mechanics and differentia equations representing oxygen membrane diffusion are combined. Relevant thermodynamic relations describing the mass of oxygen transported into the human body are proposed as the connection between these models,...
-
International Journal of Tomography and Simulation
Journals -
Advanced polarization sensitive analysis in optical coherence tomography
PublicationThe optical coherence tomography (OCT) is an optical imaging method, which is widely applied in variety applications. This technology is used to cross-sectional or surface imaging with high resolution in non-contact and non-destructive way. OCT is very useful in medical applications like ophthalmology, dermatology or dentistry, as well as beyond biomedical fields like stress mapping in polymers or protective coatings defects detection....
-
Assessment of Wooden Beams from Historical Buildings Using Ultrasonic Transmission Tomography
PublicationThe main goal of this study was non-destructive evaluation of wooden elements using ultrasonic waves. The inspection was carried out on wooden beams from a historical object. Elastic wave signals were processed by ultrasonic transmission tomography to obtain imaging of the internal structure of tested elements without disturbing their state and integrity. The focus was on the influence of wood anisotropy on the propagation of ultrasonic...
-
Design of a modular impedance tomography
PublicationW pracy przedstawiono konstrukcję, zasadę działania oraz podstawowe parametry tomografu impedancyjnedo przeznaczonego do pomiarów w gruncie.
-
Objective, observer-independent evaluation of myocardial perfusion and function: the role of SPECT
Publication -
Novel approach to modeling spectral-domain optical coherence tomography with Monte Carlo method
PublicationNumerical modeling Optical Coherence Tomography (OCT) systems is needed for optical setup optimization, development of new signal processing methods and assessment of impact of different physical phenomena inside the sample on OCT signal. The Monte Carlo method has been often used for modeling Optical Coherence Tomography, as it is a well established tool for simulating light propagation in scattering media. However, in this method...
-
Comment on "Quantitative comparison of analysis methods for spectroscopic optical coherence tomography"
PublicationIn a recent paper by Bosschaart et al. [Biomed. Opt. Express 4, 2570 (2013)] various algorithms of time-frequency signal analysis have been tested for their performance in blood analysis with spectroscopic optical coherence tomography sOCT). The measurement of hemoglobin concentration and oxygen saturation based on blood absorption spectra have been considered. Short time Fourier transform (STFT) was found as the best method for...
-
The Optical Coherence Tomography and Raman Spectroscopy for Sensing of the Bone Demineralization Process
PublicationThe presented research was intended to seek new optical methods to investigate the demineralization process of bones. Optical examination of the bone condition could facilitate clinical trials and improve the safety of patients. The authors used a set of complementary methods: polarization-sensitive optical coherence tomography (PS-OCT) and Raman spectroscopy. Chicken bone samples were used in this research. To stimulate in laboratory...
-
Spectroscopic Optical Coherence Tomography for Thin Layer and Foil Measurements
PublicationThe main goal of this research was to assess if it is possible to evaluate the thickness of thin layers (both thin films on the surface and thin layers below the surface of the tested object) and foils using optical coherence tomography (OCT) for thickness assessment under the resolution of the standard commercially available OCT measurement system. In the proposed solution, light backscattered from the evaluated thin layer has...
-
Selection of material for X-ray tomography analysis and DEM simulations: comparison between granular materials of biological and non-biological origins
PublicationPhysical properties and X-ray tomography images of five different granular materials: glass bead, glass grit, short grain white rice, sorghum and clay granules (Seramis) are investigated to select the most promising materials for numerical simulations and time-lapse X-ray tomography imaging. The examined materials represent granular materials of non-biological origin (glass bead, glass grit and Seramis) and granular plant materials...
-
Microstructure–Property Relationship of Polyurethane Foams Modified with Baltic Sea Biomass: Microcomputed Tomography vs. Scanning Electron Microscopy
PublicationIn this paper, novel rigid polyurethane foams modified with Baltic Sea biomass were compared with traditional petro-based polyurethane foam as reference sample. A special attention was focused on complex studies of microstructure, which was visualized and measured in 3D with high-resolution microcomputed tomography (microCT) and, as commonly applied for this purpose, scanning electron microscopy (SEM). The impact of pore volume,...
-
Time-frequency analysis in optical coherence tomography for technical objects examination
PublicationOptical coherence tomography (OCT) is one of the most advanced optical measurement techniques for complex structure visualization. The advantages of OCT have been used for surface and subsurface defect detection in composite materials, polymers, ceramics, non-metallic protective coatings, and many more. Our research activity has been focused on timefrequency spectroscopic analysis in OCT. It is based on time resolved spectral analysis...
-
Brain perfusion imaging with the use of parametric modelling basing on DSC-MRI data
PublicationW pracy do estymacji parametrów perfuzji mózgu: przepływu krwi mózgowej (cerebral blood flow, CBF), objętości krwi mózgowej (cerebral blood volume, CBV) oraz średniego czasu przejścia (mean transit time, MTT) wykorzystano pomiary DSC-MRI (Dynamic Susceptibility Contrast Magnetic Resonance Imaging). W modelowaniu danych MRI zastoswoano model trzykompartmentowy. Przedstawiono i porównano dwa podejścia do identyfikacji modelu różniące...
-
Advanced Monte Carlo simulator of the polarization-sensitive optical coherence tomography systems
PublicationSimulations of the optical coherence tomography (OCT) systems using the Monte Carlo method is a widely explored research area. However, there are several difficulties that need to be overcome in order to properly model the OCT imaging with the Monte Carlo algorithm. First of all, the temporal and the spatial coherence of the scattered light need to be considered, since OCT is based on the interference phenomenon. For the same reason,...
-
Dispersion compensation in optical coherence tomography
PublicationDyspersja wprowadzana przez system optycznej tomografii koherentnej (OCT) oraz badane obiekty powoduje zniekształcenia fazowe w zależności od długości fali widma promieniowania zastosowanego źródła optycznego. powoduje to rozmycie obrazów otrzymanych przekrojów badanych materiałów pogarszając właściwości metrologiczne systemu OCT. W artykule przedstawiono metody kompensacji dyspersji w systemie OCT oraz przedyskutowano ich właściwości.
-
Comparison of thermal and electrical tomography in medicine.
PublicationTechniki pomiarowo diagnostyczne - tomografia termiczna i tomografia elektroimpedancyjna - nowe w aplikacjach klinicznych walczą o zdobycie akceptacji w środowisku medycznym i w diagnostyce medycznej wybranych schorzeń. Porównano właściwości termiczne i elektroimpedancyjne tkanek biologicznych. Pokazano znaczenie obu technik w szeregu aplikacjach medycznych. Przedyskutowano zalety i wady obu metod. Wymieniono podstawowe aplikacje...
-
Application of tomography to granular silo flow.
PublicationPublikacja zawiera opis wyników badań doświadczalnych nad efektami dynamicznymi podczs opróżniania silosów z zastosowaniem tomografii pojemnościowej.
-
Computed aided system for separation and classification of the abnormal erythrocytes in human blood
PublicationThe human peripheral blood consists of cells (red cells, white cells, and platelets) suspended in plasma. In the following research the team assessed an influence of nanodiamond particles on blood elements over various periods of time. The material used in the study consisted of samples taken from ten healthy humans of various age, different blood types and both sexes. The markings were leaded by adding to the blood unmodified...
-
Silica In Silico: A Molecular Dynamics Characterization of the Early Stages of Protein Embedding for Atom Probe Tomography
PublicationA novel procedure for the application of atom probe tomography (APT) to the structural analysis of biological systems, has been recently proposed, whereby the specimen is embedded by a silica matrix and ablated by a pulsed laser source. Such a technique, requires that the silica primer be properly inert and bio-compatible, keeping the native structural features of the system at hand, while condensing into an amorphous, glass-like...
-
Polarization state analysis in optical coherence tomography
PublicationW artykule zaprezentowano metody analizy stanu polaryzacji światła w systemach optycznej tomografii kohererentnej. Przedstawiono różne konfiguracje systemu PS-OCT wraz z ich parametrami oraz właściwościami. Omówiono zasadę pomiaru stanu polaryzacji ściatła przy użyciu systemu PS-OCT oraz przeprowadzono dyskusję nad przydatnością metody do badania struktury materiałów silnie rozpraszających promieniowanie.
-
Polarization sensitive optical coherence tomography system
PublicationW pracy pokazano system OCT czuły na stan polaryzacji do pomiaru właściwości dwójłomnych wybranych ośrodków rozpraszających światło. W systemie zastosowano detekcję zrównoważoną. Pokazano wstępne wyniki pomiarowe.
-
Synthesized light source for optical coherence tomography
PublicationW artykule omówiono wpływ parametrów źródła promieniowania optycznego na właściwości systemu OCT. Szczególną uwagę zwrócono na źródła syntezowane. Omówiono charakterystykę źródła zbudowanego z dwóch różnych diod SLD. Przedstawiono wyniki pomiarów, które wskazują na możliwości znacznego polepszenia czułości i rozdzielczości systemu OCT wykorzystującego takie źródło.
-
Anisotropy and compaction gradient assessment on rammed earth specimens through sonic tomography approach
PublicationRammed earth is a traditional construction technique that has recently gained attention because of its benefits from an ecological perspective. The conservation of the existing valuable cultural heritage sites and the quality control of new constructions built with this material require the development and application of practical inspection techniques. This paper explores the application of sonic tests and sonic tomography as...
-
X-Ray Computer Tomography Study of Degradation of the Zircaloy-2 Tubes Oxidized at High Temperatures
PublicationThe investigations of high-temperature oxidation of zirconium alloys, applied for fuel pellets in nuclear power plants, are usually limited to oxidation kinetics, phase transformations and microstructural characterization. The purpose of this research was to characterize the degradation phenomena occurring within oxide layer and at the interface oxide/metal, on internal and external Zircaloy-2 tube...
-
Evaluation of early cerebral metabolic, perfusion and microstructural changes in HCV-positive patients: A pilot study
Publication -
The POCOBIO Database for Computed Scattering Cross-Sections for Positron Collisions with Biomolecular Systems
PublicationThe design of a database for positron interactions with biomolecular systems is outlined. The database contains only scattering cross sections, which are derived from theory. The data model is defined in a very flexible way, which facilitates the usage of weakly bound clusters of molecules and molecular systems with many tautomeric forms.
-
Polarization sensitive optical coherence tomography with spectroscopic analysis
PublicationOptyczna tomografia koherentna (OCT) jest nieinwazyjną, nieniszczącą i bezkontaktową metodą obrazowania wewnętrznej struktury obiektów i materiałów rozpraszających. Dodatkowo w połączeniu z analizą stanu polaryzacji metoda ta umożliwia badanie lokalnych zmian optycznej anizotropii występującej w badanym obiekcie. W artykule przedstawiono zalety oraz ograniczenia metody oraz przedstawiono propozycję rozszerzenia analizy o badanie...
-
Spectroscopic analysis for polarization sensitive optical coherent tomography
PublicationW artykule przedstawiono właściwości oraz ograniczenia optycznej tomografii koherentnej z analizą stanu polaryzacji promieniowania optycznego. Zaproponowano nową spektroskopową metodę analizy sygnału pomiarowego w PS-OCT oraz przedstawiono i omówiono zalety nowego rozwiązania na bazie uzyskanych wyników pomiarowych.
-
Theoretical and experimental investigation of Optical Coherent Tomography topologies
PublicationW artykule przedstawiono teoretyczną i eksperymentalną analizę konfiguracji interferometrów w układach koherentnego tomografu optycznego. Zaprezentowano zrealizowany układ, którego specjalnie zaprojektowana konfiguracja pozawala na analizę zmian polaryzacji sygnału pomiarowego.
-
Bbulk solids flow in silos by electrical capacitance tomography
PublicationW artykule przedstawiono wyniki doświadczeń w silosach z zastosowaniem elektrycznej tomografii pojemnościowej do pomiaru zmian wskaźnika porowatości.
-
Formulation of the inverse problem in thermal tomography for burn diagnostics.
PublicationZdefiniowano zagadnienie odwrotne w analizie przepływów ciepła w strukturach biologicznych, którego rozwiązanie jest niezbędne w tomografii termicznej. Celem jest rekonstrukcja rozkładu właściwości cieplnych w strukturze geometrycznej badanych obiektów. Wektor decyzyjny może być zdefiniowany na podstawie wiedzy o badanym obiekcie. Można wybrać liczbę nieznanych parametrów modelu termicznego tego obiektu. Dla małej liczby niezbędna...
-
Dynamic and tomography analysis of granular flow in cylindrical shell
PublicationW pracy przedstawiono wyniki badań ekperymentalnych dotyczących efektów dynamicznych występujących podczas przepływu materiałów sypkich w silosie cylindrycznym.
-
Computed vibrational excitation ofCF4by low-energy electrons and positrons: Comparing calculations and experiments
PublicationQuantum calculations for the excitation of the asymmetric modes of the CF4 target gas, ν3 and ν4, by impact of low-energy electrons and positrons are carried out in the energy range around 1 eV and are compared with recent experimental findings. The similarities and differences between the two types of projectiles, and the two different modes, are analyzed and discussed vis à vis the present accord with the experimental results.
-
Nano-particle doped hydroxyapatite material evaluation using Spectroscopic Polarization Sensitive Optical Coherence Tomography
PublicationBio-ceramics such as hydroxyapatite (HAp) are widely used materials in medical applications, especially as an interface between implants and living tissues. There are many ways of creating structures from HAp like electrochemical assisted deposition, biomimetic, electrophoresis, pulsed laser deposition or sol-gel processing. Our research is based on analyzing the parameters of the sol-gel method for creating thin layers of HAp....
-
Polarization sensitive optical coherence tomography for technical materials investigation
Publication -
Polarization sensitive optical coherence tomography for technical materials investigation
PublicationZaprezentowano system optycznej tomografii koherentnej z analizą stanu polaryzacji światła. System umożliwia nieniszczące i bezkontaktowe badanie wewnętrznej struktury materiałów warstwowych. Przedstawiono zastosowaną metodę analizy stanu polaryzacji promieniowana wstecznie rozproszonego od badanego obiektu.
-
Advances of thermal tomography in non-destructive testing and medical diagnostics
Publication -
Electrical capacitance tomography for studying the flow of friable materials in silos.
PublicationArtykuł opisuje możliwość aplikacji tomografii do pomiarów przepływu materiałów sypkich w silosach
-
Interferon‐free therapy as the cause of white matter tracts and cerebral perfusion recovery in patients with chronic hepatitis C
Publication -
Analysis of the posibbility of detect determination using cold excitation in thermal tomography
Publication -
Application of Electrical Capacitance Tomography for bulk solids flow analysis in silos
PublicationW artykule przedstawiono wyniki aplikacji metody ECT w analizie przepływów materiałów sypkich, zarówno bezkohezyjnych, jak również kohezyjnych. Omówiono podstawy techniczne metody ECT, przeprowadzono dyskusje parametrów zmiennych (zagęszczenie początkowe, szorstkość ścian).
-
Multilayered structures examination using polarization sensitive optical coherence tomography
PublicationW artykule przedstawiono wstępne wyniki badań struktur warstwowych z użyciem systemu optycznej tomografii koherentnej z analizą stanu poaryzacji (PS-OCT). Omówiono budowę systemu oraz zakres stosowalności metody do badania złożonych struktur warstwowych.
-
Ultrahigh-resolution detection techniques for biomedical applications of optical coherent tomography.
PublicationOptyczne metody pomiarowe odgrywają w ostatnich latach coraz większą rolę w badaniach i diagnostyce medycznej. Mają one szereg zalet, do których zaliczyć można odporność na promieniowanie elektromagnetyczne, bezinwazyjność, bezpieczeństwo pomiaru oraz wysoką rozdzielczość. Jedną z najważniejszych technik stosowanych w diagnostyce medycznej jest koherentna tomografia optyczna (OCT). Jest to wysokorozdzielcza metoda obrazowania wewnętrznych...
-
Quantitative active dynamic thermal Ir-Imaging and thermal tomography in medical diagnostics
Publication -
Quantitative active dynamic thermal ir-imaging and thermal tomography in medical diagnostics
PublicationPraca dotyczy nowych technik obrazowania w diagnostyce medycznej, wykorzystując przetwarzanie obrazów termicznych rejestrowanych w podczerwieni. Opisano właściwości termiczne tkanek biologicznych, omówiono medele termiczne i zdefiniowano zastępcze parametry syntetyczne, metody pomiarów i stosowane urządzenia. Omówiono procedury akwizycji danych i ich przetwarzania. Wprowadzono pojęcie tomografii termicznej. Opisano przeprowadzone...
-
Quantitative Active Dynamic Thermal IR-Imaging and Thermal Tomography in Medical Diagnostics
Publication.
-
Value of Perfusion-Weighted MR Imaging in the Assessment of Early Cerebral Alterations in Neurologically Asymptomatic HIV-1-Positive and HCV-Positive Patients
Publication