Testing high impedance analyzer in the field on high-voltage line pylon cell 1 exposition 2
Open Research DataThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 1 exposition 1
Open Research DataThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 1
Open Research DataThe dataset presents impedance spectrum of nano-nickel based coating sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 2 exposition 1
Open Research DataThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Badania eksperymentalne prostownika osiemnastopulsowego o mocy 150 kVA z opcjonalnym szeregowym energetycznym filtrem aktywnym
PublicationW artykule przedstawiono system sterowania oraz wybrane wyniki badań eksperymentalnych przekształtnika AC / DC składającego się z osiemnastopulsowego diodowego prostownika na bazie dławików sprzężonych i szeregowego energetycznego filtra aktywnego. Przebadano i porównano trzy konfiguracje przekształtnika o mocy 150kVA: (1) osiemnastopulsowy prostownik bez dodatkowych elementów, (2) prostownik z dodatkowym dławikiem sieciowym oraz...
-
Oddziaływanie przekształtników energoelektronicznych dużej mocy na jakość energii elektrycznej
PublicationW referacie przedstawiono zagadnienia związane z oddziaływaniem układów przekształtnikowych AC/DC na sieć zasilającą poprzez generowanie prądów odkształconych. Przedstawione wyniki badań porównawczych emisji zaburzeń przewodzonych układów prostownikowych klasycznych (diodowych) oraz nowoczesnych (tranzystorowych) wykazują znaczne zwiększenie emisji w zakresie stosowanych częstotliwości modulacji w typowych aplikacjach przemysłowych....
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 2
Open Research DataThe dataset presents impedance spectrum of epoxy based coating (code-name B2_B3) sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 2 exposition 2
Open Research DataThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 1
Open Research DataThe dataset presents impedance spectrum of epoxy based coating (code-name B2_B3) sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on protective foil using 2-wire probe 24h exposition
Open Research DataThe dataset presents impedance spectrum of anticorrosion foil (coating) protecting aluminium frame . This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on protective foil using 2-wire probe 48h exposition
Open Research DataThe dataset presents impedance spectrum of anticorrosion foil (coating) protecting aluminium frame . This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 3
Open Research DataThe dataset presents impedance spectrum of epoxy based coating (code-name EPCS1) sample 3. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Residual current protective device for circuits of distorted earth fault currents – concept, construction and testing
PublicationThis dissertation presents behavioral and performance verification and analysis of residual current devices (RCDs), as well as a proposal for the construction of a new RCD protection. The state of the art focuses over pre-existing design of the RCD and its behavior and response to the circuits with distorted (non-sinusoidal) earth fault currents. The study highlights the loopholes of the existing design and depicts the problem...
-
Synthesis, structure and physical properties of new intermetallic spin glass-like compounds RE2PdGe3 (RE = Tb and Dy)
PublicationNew intermetallic compounds Tb2Pd1.25Ge2.75 and Dy2Pd1.25Ge2.75 have been synthesized using the arc-melting method. The crystallographic structure and magnetic, electronic transport, and thermal properties are reported. The crystal structure obtained from powder x-ray diffraction analysis suggests that these compounds crystallize in the AlB2-type structure (space group P6/mmm, no. 191) with lattice parameters a = 4.228 53(5)/4.230 54...
-
Analytical comparison between capacitor assisted and diode assisted cascaded quasi-z-source inverters
PublicationQuasi-Z falownik z prostym obwodem impedancyjnym jest bardzo interesującym rozwiązaniem topologicznym ze względu na unikalną możliwość jednostopniowego przekształcanie DC/AC w połączeniu z funkcjami obniżania i podwyższania napięcia. W niektórych aplikacjach jego właściwości podwyższające są jednak niewystarczające. Wyższe napięcie wejściowe można uzyskać w wyniku zastosowania w quasi-Z-falownikach kaskadowych obwodów impedancyjnych....
-
Determination of pitting corrosion stage of stainless steel by galvanodynamic impedance spectroscopy
PublicationThis paper investigates the methodology for differentiation of multistep process of pitting corrosion of AISI 304 stainless steel in the environment of iron (III) chloride. Measurements were performed using Galvanodynamic Electrochemical Impedance Spectroscopy (GDEIS). Application of this methodology allowed monitoring of natural corrosion process without external current (IDC = 0A) nor potential perturbation of the system. Applied...
-
Experimental investigations and simulations of the microturbine unit with permanent magnet generator
PublicationIn dispersed power generation, low power devices are used for local combined generating of heat end electric power. There are developing concepts of micropower plants with electric generators driven by steam or gas microturbines. The paper presents the results of an experimental investigations of the microturbine set consists of the turbine with partial admission, permanent magnet generator and three phase AC-to-DC rectifier. The...
-
Zagrożenie porażeniem podczas gaszenia pożaru w budynkach z fotowoltaicznymi źródłami energii
PublicationPodczas prowadzenia akcji gaśniczej w budynku z fotowoltaicznymi źródłami energii występuje zwiększone ryzyko porażenia prądem elektrycznym ze względu to, że moduły fotowoltaiczne są źródłami autonomicznymi i mogą generować niebezpieczne napięcie mimo odłączenia inwertera zarówno od strony AC, jak i DC instalacji elektrycznej. Szczególnie duże ryzyko porażenia powstaje podczas dotknięcia przez strażaka przewodów pod napięciem przyłączonych...
-
Detekcja i lokalizacja nieprzewodzenia tranzystorów falownika napięcia na podstawie analizy prądu obciążenia
PublicationPrzedstawiono nową metodę detekcji i lokalizacji nieprzewodzenia tranzystorów w falownikach napięcia zasilających silniki indukcyjne małej mocy. Metoda bazuje na monitorowaniu wartości dwóch sygnałów dia-gnostycznych. Pierwszy z nich, wskaźnik braku przepływu prądu, wykorzystano w celu detekcji uszkodzeń. Drugi, stosunek wartości średniej prądu do wartości średniej bezwzględnej, zawiera informacje umożliwiające lokalizację uszkodzonych...
-
The Influence of a Photovoltaic Micro-Installation on the Low-Frequency Parameters of Electricity at PCC and Its Impact on the Thermal Characteristics of Selected Devices
PublicationThis manuscript illustrates the measurement results of parameters describing the quality of energy at the PCC (point of common coupling) of a photovoltaic micro-installation that can significantly affect devices in the same power grid. The analyses reflecting heating of selected devices used in domestic installations, which were performed in an isolated laboratory environment, are also indicated. The conducted study aimed at checking...
-
SiC-based T-type modules for multi-pulse inverter with coupled inductors
PublicationThe paper presents SiC-based three-level T-type modules designed for a high-performance 30kVA DC/AC inverter operating at high frequency 85 kHz with low THD of the output voltage. This inverter system consists of two integrated parts. The first part is active and contains three parallelconnected three-phase T-type modules built with fast-switching SiC power transistors. The second, passive part of the system is a set of inductors...
-
Assessment of Electronic Sensing Techniques for the Rapid Identification of Alveolar Echinococcosis through Exhaled Breath Analysis
PublicationHere we present a proof-of-concept study showing the potential of a chemical gas sensors system to identify the patients with alveolar echinococcosis disease through exhaled breath analysis. The sensors system employed comprised an array of three commercial gas sensors and a custom gas sensor based on WO3 nanowires doped with gold nanoparticles, optimized for the measurement of common breath volatile organic compounds. The measurement...
-
Electrical properties and structure of lead-borate glass containing iron ions.
PublicationThe ac and dc conductivity in iron–lead-borate glass samples was investigated in the frequency range from 1 mHz to 1 MHz and in the temperature range from 153 K to 423 K. The structure was investigated by the means of atomic force microscopy (AFM) and the crystalline phases (if present) were identified by the means of X-ray diffractometry. Two types of ac electrical behaviour were observed. The first group of glass samples which...
-
Long-term measurements from a photovoltaic power plant and meteorological stations at the Laboratory LINTE^2 of Gdańsk University of Technology
Open Research Data1) The Laboratory LINTE^2 is a large research infrastructure operated by the Faculty of Electrical and Control Engineering at Gdańsk University of Technology, to be found in Gdańsk, Poland (54.3690 N, 18.6130 E). 2) The measurements have been collected from a photovoltaic power plant located on the roof of the laboratory, having total capacity...
-
Measurements of radiation emission of a portable power bank with a capacity of 10400 mAh
Open Research DataThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell (Fig. 1). The test setup was configured to measure a portable power...
-
Electrochemical investigations on corosivity of de-icing liquids for railway infrastructure
PublicationThe paper presents the results of electrochemical tests of the de-icing fluid for railway infrastructure. DC and AC electrochemical tests were performed to determine the corrosion rates of structural steel, cast iron and aluminium in the newly produced fluid. The results were compared with the corrosion rates of the same materials in the fluid without corrosion inhibitors. The obtained test results indicate a low corrosion risk...
-
Current harmonic controller in multiple reference frames for series active power filter integrated with 18-pulse diode rectifier
PublicationThe paper presents the control system and selected results of experimental tests of the AC/DC power converter consisting of an 18-pulse diode rectifier based on coupled reactors and a serial active power filter. Proportional integral controllers with decoupling components are implemented in multiple reference frames for selective line current harmonic suppression. The regulator is provided with a backtracking anti-windup mechanism...
-
Falowniki napięcia z quasi-rezonansowym obwodem pośredniczącym w układach napędowych
PublicationW monografii przedstawiono zagadnienia związane z wykorzystaniem pośrednich przemienników częstotliwości z rezonansowymi oraz quasi-rezonansowymi obwodami pośredniczącymi w układach napędowych. Omówiono wpływ przełączania „twardego” przy niezerowych prądach i napięciach łączników na właściwości eksploatacyjne elektrycznego układu napędowego. Ponadto dokonano przeglądu wybranych topologii przekształtników DC/AC, zapewniających techniki...
-
Nanostructure and dielectric behavior of vanadate glasses containing BaTiO3
PublicationThe ac and dc electrical conductivity of barium titanate doped bismuth-vanadate as-quenched and heat-treated materials was measured in the frequency range from 1 mHz to 1 MHz and in the temperature range from 153 K to 423 K with the impedance spectroscopy method. The microstructure was investigated by means of XRD, scanning electron microscopy (SEM), atomic force microscopy (AFM) and confocal microscopy. The obtained results showed...
-
Electrical properties of Na2O-CaO-P2O5 glasses doped with SiO2 and Si3N4
PublicationSodium-calcium-phosphate glasses doped with SiO2 or Si3N4 having similar sodium ion concentrations were prepared by melt quenching. The conductivity was measured by impedance spectroscopy under nitrogen atmosphere in a wide frequency range (10 mHz–1 MHz) and wide temperature range (153–473 K). At 36.6 °C, DC conductivities of all glasses vary between 1.1 ∗ 10−12 and 8.9 ∗ 10−12 S cm−1 and have similar activation energies (between...
-
AutoCAD - DC Edukacja
e-Learning CoursesAutoCAD DC Edukacja
-
Measurements of radiation emission of a portable power bank with a capacity of 5200 mAh
Open Research DataThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell. The test setup was configured to measure a portable power bank...
-
Measurements of radiation emission of a portable power bank with a capacity of 2600 mAh
Open Research DataThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell. The test setup was configured to measure a portable power bank...
-
New insights into structural, optical, electrical and thermoelectric behavior of Na0.5Bi0.5TiO3 single crystals
PublicationThe single crystals of lead-free Na0.5Bi0.5TiO3 were grown using the Czochralski method. The energy gaps determined from X-ray photoelectron spectroscopy (XPS) and optical measurements were approximately 2.92 eV. The current-voltage characteristics, depolarization current, dc (σdc) and ac (σac) electrical conductivity, and Seebeck coefficient of the crystals were investigated. The frequency/temperature-dependent electrical properties...
-
STANY NIEUSTALONE TOWARZYSZĄCE POMIAROWI IMPEDANCJI PĘTLI ZWARCIA W OBWODACH WYJŚCIOWYCH ZASILACZY BEZPRZERWOWYCH UPS
PublicationW pracy przedstawiono metodykę i wyniki pomiarów stanów nieustalonych w zasilaczu bezprzerwowym (UPS) typu on - line. Do rejestracji zdarzeń po stronie zasilania i na wyjściu UPS wykorzystano dwa przyrządy do pomiaru jakości energii elektrycznej zsynchronizowane czasowo. Rejestratory kompresują uzyskane dane pomiarowe, co może wprowadzać dodatkowe błędy pomiaru wielkości mierzonych – napięć i prądów. Dodatkowe rejestracje oscyloskopem...
-
Power Hardware-In-the-Loop Approach for Autonomous Power Generation System Analysis
PublicationThe article presents the Power Hardware-In-the-Loop (PHIL) dynamic model of a synchronous generator of 125 kVA for autonomous power generation system analysis. This type of system is typically composed of electrical energy sources in the form of several diesel generator units with synchronous machines, the main distribution switchboard and different loads. In modern power distribution systems, the proposed power management strategies...
-
The power spectral density of audible noise and electric disturbances in ship’s electrical drive systems with frequency converters
Open Research DataThe presented dataset is part of research focusing on the impact of the ship's electrical drive systems with frequency converters on vibrations and the level of audible noise on ships.
-
Measurements of power supply system properties of "Magnetic SpeedLine" ultra-fast robot prototype for IML labeling
Open Research DataTests of the power supply system of "SpeedLine magnetic" ultra-fast industrial robot for IML labeling were carried out to analyze the effect of the active power filter (APF) parameters on the power quality. at the target duty cycle. Tests were performed with the target duty cycle. Linear synchronous motors with permanent magnets were used to drive...
-
Low Frequency Conducted Emissions of Grid Connected Static Converters
PublicationPulse-width modulated rectifiers are nowadays commonly used for AC to DC power conversion. PWM rectification technology is very effective and allows for bidirectional power flow with the possibility of power factor improvement and low-order harmonic emission limitation. Unfortunately, employed PWM boost topology results with generation of input current harmonic distortions in a frequency range tightly correlated to modulation frequency....
-
High Frequency Harmonics Emission in Smart Grids
PublicationPulse-width modulated rectifiers are nowadays commonly used for AC to DC power conversion. PWM rectification technology is very effective and allows for bidirectional power flow with the possibility of power factor improvement and low-order harmonic emission limitation. Unfortunately, employed PWM boost topology results with generation of input current harmonic distortions in a frequency range tightly correlated to modulation frequency....
-
Investigation of structural, thermal, and electrical properties of sodium-doped oxynitride glass-ceramics
PublicationThis study aimed to investigate the influence of Na2O addition on the structural, thermal, and electrical characteristics of oxynitride glass-ceramics within the Na–K–Mg–Ca–Al–Si–O–N system. Oxynitride glass-ceramic samples were prepared via spark plasma sintering (SPS) with sodium oxide doping levels ranging from 0 wt% to 12 wt%. FESEM analysis revealed changes in sample morphology with increasing sodium content, indicating the...
-
Single and Three -Phase PWM AC/AC Converters as Semiconductor Transformers
PublicationAC voltage transformation circuits contain pure or reactance PWM AC/AC converters. These circuits can be treated as AC/AC semiconductor transformers. This paper reviews single-phase and three-phase topologies: both non-isolated and isolated, single as well as two quadrant structure. Additionally, this paper present selected examples of their applications.
-
The conducted EMI in DC-DC converters
PublicationThis book presents the phenomena of conducted electromagnetic interference (EMI) generation in DC-DC converters. The measurement and simulation are used to analyze the impact of the most important parameters on the character, level and propagation path of interference. In this book, the analysis of the interference generation and propagation is presented on the example of three basic converters. The wide banded behavior of all...
-
The new SDMT-family of servo-drives for CNC systems with AC permanent magnet synchronous motors
PublicationW artykule przedstawiono strategię sterowania podstawowe parametry oraz wyniki badań nowej rodziny serwonapędów typu SDMT. Układ sterowania serwonapędu zbudowano na procesorze sygnałowym TMS320F2812 firmy Texas Instruments. W serwonapędzie zastosowano metodę sterowania tupu FOC (ang. Field Oriented Control). Regulatory położenia, prędkości i momentu zreali-zowano na bazie klasycznego regulatora PID z układem ograniczenie sygnału...
-
Cost-Effective Piggyback Forward dc-dc Converter
PublicationThe novel piggyback dc-dc converter as a cost-effective solution is presented in this work. It provides a wide input voltage range of regulation with a low component count. The novel solution is an advanced forward dc-dc converter with an additional clamp output capacitor. The idea of such a type of converter is to transfer magnetizing energy of transformer to the output side, instead of using input clamp circuit. The design guidelines...
-
Prediction of ringing frequencies in DC-DC boost converter
PublicationIn the paper ringing phenomena in a DC-DC boost converter is presented. The ringing frequency is calculated using an analytical formula. The necessary wide band models of MOSFET transistor, passive and parasitics are described. The calculation results are verified in simulation and laboratory tests.
-
Badania symulacyjne wysokonapięciowej przetwornicy DC/DC
PublicationW artykule zaprezentowano wyniki badań symulacyjnych przekształtnika energoelektronicznego typu DC/DC działającego w układzie niepełnego mostka z transformatorem izolacyjnym pracującym przy dużej częstotliwości. Badania symulacyjne wykonano posługując się pakietem Matlab-Simulink z biblioteką SimPowerSystems. Omówiono problemy zastosowania wysokonapięciowych tranzystorów z izolowaną bramką do konstrukcji przekształtników wysokiego...
-
AC loss measurements in superconducting magnet
PublicationThis report contains ordered theoretical informations about AC loss in superconducting magnets and cables. A software program to evaluate data from AC loss measurements with V-I method was made and it is also described. Examples of measurement data and result data are shown here.
-