displaying 1000 best results Help
Search results for: STRAY-CURRENT CORROSION
-
Remote current measurement with FPGA digital processing
PublicationThe work presents an implementation of a modular measurement and control systemthat controls variants of mains supply of 230V electrical equipment. The system allowsto supervise power consumption in the office electronic equipment. The system detectsthe instant of the reduced power consumption by a device and makes possible itsswitch-off in order to reduce energy cost. The current is measured with integratedcurrent/voltage converters....
-
Yerba Mate - A Long but Current History
PublicationBearing in mind the growing interest in Yerba Mate, a comprehensive study has been prepared containing the most important aspects and possibilities of its use. The introduction of the work contains the species characteristics of Yerba Mate, as well as information about the origin and places of cultivation. The next part focuses on the analysis of the composition, pointing to purine alkaloids, polyphenols, saponins, and minerals...
-
Corrosion Properties of Dissimilar AA6082/AA6060 Friction Stir Welded Butt Joints in Different NaCl Concentrations
PublicationA solid-state friction stir welding method which is increasingly used in the marine and shipbuilding industry, has been developed to produce welds with high mechanical properties. In seawater, the oxide layer of aluminium is attacked by Cl− ions resulting in its disruption and formation of pitting corrosion. It is particularly important to determine the electrochemical properties of the produced welds and to evaluate the efect...
-
Acoustic emission studies of the 7075 aluminium alloy pitting corrosion process
Open Research DataThe dataset contains the cyclic polarization studies and corresponding acoustic emission measurements, revealing the pitting corrosion process of the passive layer at the surface of the 7075 aluminum alloy in the borate buffer with different chloride ions concentrations, in the range between 0.05 and 25 mM.
-
Improving sensitivity of residual current transformers to high frequency earth fault currents
PublicationFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed...
-
Characterization of Corrosion-Induced Fracture in Reinforced Concrete Beams Using Electrical Potential, Ultrasound and Low-Frequency Vibration
PublicationThe paper deals with the non-destructive experimental testing of the reinforced concrete beams under progressive corrosion. A series of experiments using electrical potential, ultrasound and low-frequency vibrations techniques are reported. Electrical potential and natural frequencies were used to characterise and monitor the corrosion process at its initial state. The P-wave velocity measurements were proved to be effective in...
-
Current advances in membrane processing of wines: A comprehensive review
PublicationBackground Membrane-based operations, especially pressure-driven membrane operations, are today well-established procedures for various applications in the wine industry thanks to their intrinsic properties and undoubted advantages over traditional methods. Emerging membrane processes, such as pervaporation, electrodialysis and osmotic distillation, forward osmosis, membrane contactors, offer new and interesting perspectives to...
-
Understanding the origin of high corrosion inhibition efficiency of bee products towards aluminium alloys in alkaline environments
PublicationVarious bee products were found to be efficient corrosion inhibitors of aluminium in different environments. In particular, bee pollen was found to be highly effective in alkaline electrolytes, yet its highly complex composition and possible synergistic interactions hinder determination of the compounds acting as active corrosion inhibitors. The main purpose of the following work is to investigate the effect of solvents used for...
-
Experimental and Quantum Chemical Evaluation of 8-Hydroxyquinoline as a Corrosion Inhibitor for Copper in 0.1 M HCl
PublicationThe corrosion inhibition properties of 8-hydroxyquinoline (8-HQ) in 0.1 M HCl for copper have been investigated by using experimental (electrochemical impedance spectroscopy (EIS), dynamic electrochemical impedance spectroscopy (DEIS), and potentiodynamic polarization) and theoretical methods complemented by surface morphological examination with the aid of scanning electron microscopy (SEM) and electron dispersive X-ray spectroscopy...
-
Requirements for Residual Current Devices Intended for Electric Vehicle Charging Systems
PublicationThe properties of residual current devices have been presented from the point of view of their ability to detect a specific shape of the residual current waveform. Moreover, the standard requirements relating to residual current protection used in electric vehicle charging installations have been pointed out. The operating characteristics of the IC-CPD and RDC-DD protections, which are intended for charging electric vehicles in...
-
Current Challenges in Targeting Tumor Desmoplasia to Improve the Efficacy of Immunotherapy
Publication -
Tax system in Poland - current situation and direction of changes
Open Research DataThe study conducted on a group of 259 entrepreneurs from various regions of Poland concerns the opinions of business owners on the current tax situation, as well as potential changes in the tax system.
-
The effect of earth fault current harmonics on tripping of residual current devices
PublicationSzerokie zastosowanie przekształtników, a w szczególności przemienników częstotliwości sprawia, że wyłączniki różnicowoprądowe znajdują się w obwodach, w których może płynąć odkształcony prąd ziemnozwarciowy. Prąd ziemnozwarciowy w obwodach z przemiennikami częstotliwości zawiera harmoniczne, których rząd głównie zależy od częstotliwości PWM. Odkształcony prąd wpływa na poprawne wyzwalanie wyłączników różnicowoprądowych. W artykule...
-
Compensation of supply current harmonics, reactive power, and unbalanced load current balance in the closed-loop control of a shunt active power filter
PublicationThis paper presents the compensation tasks performed by a shunt active power filter, including compensation of harmonic currents, reactive power, and an unbalanced load current. The paper demonstrates novel control of the shunt active power filter in a closed-loop system. The control algorithm was verified by performing simulations and compared the simulated results with those obtained in an open-loop control system. All simulations...
-
Behavior of residual current devices at frequencies up to 50 kHz
PublicationThe use of residual current devices (RCDs) is obligatory in many types of low-voltage circuits. They are devices that ensure protection against electric shock in the case of indirect contact and may ensure additional protection in the case of direct contact. For the latter purpose of protection, only RCDs of a rated residual operating current not exceeding 30 mA are suitable. Unfortunately, modem current-using equipment supplied...
-
Automated Diagnostics of Current Pick-Up Disturbances in Electric Traction Networks
PublicationThe present work defines the basic causes of bow disturbances of current pick-up, sets a task of establishing a system of automated control of bow disturbances at feeder zones of electric traction networks, proposes structural variants of the technical system implementation, describes the algorithm of detection of bow disturbances of current pick-up.
-
Evaluation of cavitation erosion–corrosion degradation of mild steel by means of dynamic impedance spectroscopy in galvanostatic mode
Publication -
Evaluation of cavitation erosion-corrosion degradation of mild steel by means of Dynamic Impedance Spectroscopy in galvanostatic mode
PublicationPrzedstawiono wyniki badań degradacji stali węglowych na skutek oddziaływania erozji-korozji kawitacyjnej. Do analizy wykorzystano technikę Dynamicznej Elektrochemicznej Spektroskopii Impedancyjnej w trybie galwanostatycznym, bliżej odwzrorowującym warunki naturalne. Do oceny stopnia degradacji posłużyły również funkcja ubytku masy MDPR oraz obrazy mikroskopowe SEM. Potwierdzono wpływ łączonej degradacji erozyjno-korozyjnej na...
-
A comprehensive evaluation of mimosa extract as a corrosion inhibitor on AA6060 alloy in acid rain solution: part I. Electrochemical AC methods
PublicationThe inhibition effect of mimosa extract on the corrosion of AA6060 aluminum alloy in acid rain solution was investigated by electrochemical impedance spectroscopy and dynamic electrochemical impedance spectroscopy (DEIS). All the studied electrochemical parameters showed good corrosion inhibitive characteristics with respect to the aluminum alloy in the tested solution. Inhibitor efficiency increased with the concentration and...
-
Effective yttrium based coating for steel interconnects of solid oxide cells: Corrosion evaluation in steam-hydrogen atmosphere
PublicationThis work describes manufacture, analysis and test of a new well conducting corrosion-protection coating that can be applied on steel types with high chromium content. Electrolytic deposition of yttrium salts is used to form thin (<100 nm) coatings on both flat steel sheets (material: Crofer 22 APU) and its properties are proven on woven wire-meshes (materials from two different sources: SUS316 and SUS316L). The oxide scale on...
-
Behavior of residual current devices at earth fault currents with DC component
PublicationLow-voltage electrical installations are increasingly saturated with power electronic converters. Due to very high popularity of photovoltaic (PV) installations and the spread of electric vehicles (EV) as well as their charging installations, DC–AC and AC–DC converters are often found in power systems. The transformerless coupling of AC and DC systems via power electronic converters means that an electrical installation containing...
-
Hydrogen-enhanced stress corrosion cracking and corrosion fatigue of HSLA steels in sea-water
PublicationPrzedstawiono ocenę podatności stali o wysokiej wytrzymałości na naprężeniowe pękanie korozyjne i zmęczenie korozyjne wspomagane przez wodór. Wykonano próby powolnego rozciągania i zmęczenia niskoczęstotliwościowego na stalach 17HMBVA i 14HNMBCu oraz ich złączach spawanych, w środowisku wody morskiej, przy polaryzacji katodowej. Zamieszczono wyniki badań elektrochemicznych oraz przełomów na skaningowym mikroskopie elektronowym.
-
Electrochemical investigations on the corrosion behaviour of reinforcing steel in diatomite- and zeolite-containing concrete exposed to sulphuric acid
PublicationCorrosion is a major concern for most structural applications. Its detrimental effect significantly reduces the life of metallic components. This paper presents the results of an experimental investigation of corrosion in the steel reinforcement of concrete samples having three different substituents: 20% diatomite, 20% zeolite, and a reference without zeolite or diatomite. All concrete specimens were subjected to a solution of...
-
Selection of Organic Coating Systems for Corrosion Protection of Industrial Equipment
PublicationThe most important element of corrosion protection in industrial conditions is the protective coating system. However, selecting the right coating can often be a real problem due to the sheer number of coating manufacturers and their products on the market. A quantitative approach based on the data mining technique used to analyze the obtained multi-site exposure data has been proposed. This was demonstrated by the example of the...
-
Corrosion Inhibition Mechanism and Efficiency Differentiation of Dihydroxybenzene Isomers Towards Aluminum Alloy 5754 in Alkaline Media
PublicationThe selection of efficient corrosion inhibitors requires detailed knowledge regarding the interaction mechanism, which depends on the type and amount of functional groups within the inhibitor molecule. The position of functional groups between different isomers is often overlooked, but is no less important, since factors like steric hinderance may significantly affect the adsorption mechanism. In this study, we have presented how...
-
Testing sensitivity of A-type residual current devices to earth fault currents with harmonics
PublicationIn many applications, modern current-using equipment utilizes power electronic converters to control the consumed power and to adjust the motor speed. Such equipment is used both in industrial and domestic installations. A characteristic feature of the converters is producing distorted earth fault currents, which contain a wide spectrum of harmonics, including high-order harmonics. Nowadays, protection against electric shock in...
-
Comprehensive compensation of grid current distortion by shunt active power filters
PublicationThe paper presents a comprehensive approach to the compensation of grid current distortion in shunt active power filter systems. Four sources of current distortion are addressed: imperfect grid synchronization caused by the distortion in the grid voltages, time delays in the evaluation of grid voltages and computation of compensating currents, fluctuations of the dc bus voltage, and the distortion of inverter output voltages due...
-
Comparison of residual current devices tripping characteristics for selected residual current waveforms
PublicationZgodnie z normami międzynarodowymi, w instalacjach o zwiększonym ryzyku porażenia prądem elektrycznym należy stosować wyłączniki różnicowoprądowe wysokoczułe. Dla zapewnienia skutecznej ochrony przeciwporażeniowej zainstalowany wyłącznik różnicowoprądowy powinien prawidłowo wykrywać określony kształt prądu różnicowego. W artykule przedstawiono charakterystyki działania wyłączników różnicowoprądowych przy wybranych przebiegach odkształconego...
-
Analysis of features of stainless steels in dissimilar welded joints in chloride inducted corrosion
PublicationStainless steels of femtic-austenitic microstructure that means the duplex Cr-Ni-Mo steels, in comparison with austenitic steel includes less expensive nickel and has much better mechanical properties with good formability and corrosion resistance, even in environments containing chloride ions. Similar share of high chromium ferrite and austenite, which is characterized by high ductility, determines that the duplex steels have...
-
Time-current tripping curves of arc fault detection devices
PublicationTripping curves of arc fault detection devices, in accordance with PN-EN 62606 “General requirements for arc fault detection devices” have been presented in the paper. Consequently the most fundamental differences in arc fault detection devices tripping compared to circuit-breakers and residual current devices have been indicated.
-
Magnetic Field Generated by Short Circuit Current in the 110 kV Power System
PublicationElectric fields within tissues induced by magnetic fields including transients or short-term peaks should not be time averaged and be regarded as instantaneous values as established in the ICNIRP (International Commission on Non - Ionizing Radiation Protection) guidelines. Measurements of power lines magnetic fields with regard to human beings exposure are carried out typically with maximum current load at current balance condition...
-
Modular high precision high current source for special applications — Simulation and verification
PublicationThis paper presents selected issues concerning realization of high precision high current source for special applications, where high demands of output parameters of such device are required. A new 80 kW prototype of modular high precision high current source is presented, where output current accuracy reaches 5x10-5. This paper presents also results of operation of the simulation model and of the prototype converter. In order...
-
Mobility management solutions for current IP and future networks
PublicationEnormous progress in the design of portable electronic devices allowed them to reach a utility level comparable to desktop computers, while still retaining their mobility advantage. At the same time new multimedia services and applications are available for IP users. Unfortunately, the performance of base IP protocol is not satisfactory in mobile environments, due to lack of handover support and higher layer mobility management...
-
Impedance of metastable pitting corrosion
PublicationPrzeprowadzono badania impedancyjne metastabilnego procesu korozji wżerowej. Kształt chwilowych widm impedancyjnych otrzymanych w wyniku eksperymentu jest ściśle związany z przebiegiem prądu dc. O szybkość korozji wewnątrz aktywnego zaatakowania decyduje proces przeniesienia ładunku. Ekspansja aktywnej powierzchni jest proporcjonalna do zmian podwójnej warstwy elektrycznej. Zaobserwowane zostały również zmiany rezystancji elektrolitu...
-
Current based Normalized Triple Covariance as a bearings diagnostic feature in induction motor
PublicationDiagnosis of induction motors, conducted remotely by measuring and analyzing the supply current is attractive with the lack of access to the engine. So far there is no solution, based on analysis of current, the credibility of which allow use in industry. Statistics of IM bearing failures of induction motors indicate, that they constitute more than 40% of IM damage, therefore bearing diagnosis is so important. The article provides...
-
The influence of microstructure on the corrosion resistance for some titanium-based alloys
Open Research DataThis dataset contains scanning electron microscopy (SEM) micrographs revealing the microstructure of some Ti-based alloys, namely: Ti-6Al-4V (file name: TiV), Ti-6Al-7Nb (file name: TiNb) and TC21 (file name: TiAlSnZrMoCrNbSi) alloys and their localized corrosion as a result of passive layer breakdown in a corrosive environment, ie. 0.9% NaCl solution...
-
Speed sensorless induction motor drive with predictive current controller
PublicationToday, speed sensorless modes of operation are becoming standard solutions in the area of electric drives. This paper presents a speed sensorless control system of an induction motor with a predictive current controller. A closed-loop estimation system with robustness against motor parameter variation is used for the control approach. The proposed algorithm has been implemented using field-programmable gate arrays (FPGAs) and a...
-
Actual field corrosion rate of offshore structures in the Baltic Sea along depth profile from water surface to sea bed
PublicationThe paper presents the results of field electrochemical investigations on the corrosion rate of carbon steel in seawater of the Baltic Sea at the location of the Baltic Beta production rig. The measurements were conducted throughout the year in seawater at different depths from the sea surface to the sea bed (about 75 m). The results revealed corrosion aggressiveness of the seawater along the entire depth profile. There was...
-
Juliusz Orlikowski prof. dr hab. inż.
People -
The effect of the motor filters on earth fault current waveform in circuits with variable speed drives
PublicationIn circuits with variable speed drives distorted earth fault current flows. Earth fault current distortion influences the threshold of ventricular fibrillation. This paper presents earth fault current distortion in circuits with variable speed drives when motor filter is used. Two types of motor filter are analyzed. For every type of filter the effect of earth fault current distortion on ventricular fibrillation is evaluated.
-
The effect of the motor filters on earth fault current waveform in circuits with variable speed drives
PublicationIn circuits with variable speed drives distorted earth fault current flows. Earth fault current distortion influences the threshold of ventricular fibrillation. This paper presents earth fault current distortion in circuits with variable speed drives when motor filter is used. Two types of motor filter are analyzed. For every type of filter the effect of earth fault current distortion on ventricular fibrillation is evaluated.
-
Sensorless Control of Induction Machine Supplied by Current Source Inverter
PublicationThe paper describes the voltage control technique of induction machines supplied by a current source inverter. The control system is based on proposed new multi-scalar variables, which are named “r.” The control system contains the output filter capacitor's model. In the sensorless control system the Z type backstepping speed observer was applied. The mathematical dependences are confirmed by simulation and experimental research.
-
Electrochemical methods for corrosion rate determination under cathodic polarisation conditions - a review. Part II - AC methods
PublicationPrzedstawiono krytyczny przegląd prac dotyczących wykorzystania metod elektrochemicznych zmiennoprądowych do wyznaczania prądu korozyjnego metali polaryzowanych katodowo. Przedyskutowano stosowanie klasycznej liniowej spektroskopii impedancyjnej (EIS) z użyciem sygnałów pobudzających niskoamplitudowych, a następnie techniki zmiennoprądowe bazujące na sygnałach wysokoamplitudowych, a więc w zakresie nieliniowej charakterystyki polaryzacyjnej...
-
Electrochemical methods for corrosion rate determination under cathodic polarisation conditions - a review. Part I - DC methods
PublicationPrzedstawiono krytyczny przegląd prac dotyczących wykorzystania metod elektrochemicznych stałoprądowych do wyznaczania prądu korozyjnego metali polaryzowanych katodowo. Opisano dotychczasowe sposoby oceny skuteczności ochrony katodowej na podstawie pomiarów krzywych polaryzacji i rezystancji polaryzacyjnej. Scharakteryzowano metody matematyczne i oprogramowanie opracowane do analizy komputerowej krzywych polaryzacji w celu wyznaczenia...
-
Morphology and corrosion characteristics of laser surface remelted Al-Sialloy at cryogenic conditions
PublicationPrzedstawiono koncepcję obróbki laserowej stopu Al-Si w warunkach kriogenicznych. Określono jej wpływ na lokalny skład chemiczny oraz mikrostrukturę i właściwości korozyjne wymienionego stopu. Stwierdzono znaczącą poprawę właściwości korozyjnych w 0,01 M H2SO4.
-
Programmable Input Mode Instrumentation Amplifier Using Multiple Output Current Conveyors
PublicationIn this paper a programmable input mode instrumentation amplifier (IA) utilising second generation, multiple output current conveyors and transmission gates is presented. Its main advantage is the ability to choose a voltage or current mode of inputs by setting the voltage of two configuration nodes. The presented IA is prepared as an integrated circuit block to be used alone or as a sub-block in a microcontroller or in a field...
-
Corrosion resistance evaluation of Al‐based alloys by means of dynamic electrochemical impedance spectroscopy
Publication -
Instantaneous impedance evaluation of dissolution of aisi 304 stainless steel during intergranular corrosion
PublicationCelem pracy było uzyskanie informacji dotyczących zróżnicowania parametrów elektrycznych uzyskanych na podstawie zarejestrowanych chwilowych widm impedancyjnych w zakresie aktywacji i reaktywacji roztwarzania wysokostopowej stali austenitycznej AISI podczas postępującego procesu korozji międzykrystalicznej. Badania prowadzono z wykorzystaniem dynamicznej elektrochemicznej spektroskopii impedancyjnej (DEIS). Pomiary wykonywano ''on-line''...
-
Corrosion resistance evaluation of Al-based alloys by means of dynamic electrochemical impedance spectroscopy
PublicationW pracy przedstawiono wyniki badań stopów aluminium wykonane za pomocą dynamicznej elektrochemicznej spektroskopii. Na podstawie uzyskanych widm impedancyjnych zostały pokazane zmiany parametrów elektrycznego schematu zastępczego z potencjałem. Stwierdzono, że dodatek magnezu do badanego stopu obniża właściwości przeciwkorozyjne stopu.
-
Modification of the operating point of residual current transformers for high frequency earth fault currents detection
PublicationFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when earth fault current with high frequency components occurs. Serious hazard of electrocution exists then. One of the most important element of residual current devices is a residual current transformer with iron core. Tripping characteristic of residual current devices strictly...