A Review of Reduction Methods of Impact of Common-Mode Voltage on Electric Drives.
PublicationIn this survey paper, typical solutions that focus on the reduction in negative effects resulting from the common-mode voltage influence in AC motor drive applications are re-examined. The critical effectiveness evaluation of the considered methods is based on experimental results of tests performed in a laboratory setup with an induction machine fed by an inverter. The capacity of a common-mode voltage level reduction and voltage...
-
Common-Mode Voltage and Bearing Currents in PWM Inverters: Causes, Effects and Prevention
PublicationIn modern induction motor drives an increase of transistors' switching frequency and a decrease of switching times are the sources of some serious problems. The high dv/dt and the common mode voltage generated by the inverter PWM control results in the appearances of bearing currents, shaft voltages, motor terminal overvoltages, the decrease of motor efficiency, and electromagnetic interference. The aspects of common mode (CM)...
-
Series Passive Compensation of Common Mode Voltage in Multilevel Inverter Drives
PublicationThis paper presents an approach to the problem of a magnetic saturation of CM chokes that accompanies the method of passive compensation of a common mode (CM) voltage in an inverter drive system. Measurements have been provided in a drive system including multilevel inverters and the filter having sinusoidal output voltages and zero CM voltage. The theoretical analysis and experimental results show that the problem with magnetic...
-
A New Approach to the PWM Modulation for the Multiphase Matrix Converters Supplying Loads with Open-End Winding.
PublicationThis article presents three variants of the Pulse Width Modulation (PWM) for the Double Square Multiphase type Conventional Matrix Converters (DSM-CMC) supplying loads with the open-end winding. The first variant of PWM offers the ability to obtain zero value of the common-mode voltage at the load's terminals and applies only six switches within the modulation period. The second proposal archives for less Total Harmonic Distortion...
-
Resonant DC link inverters for AC motor drive systems – critical evaluation
PublicationIn this survey paper, resonant and quasiresonant DC link inverters are reexamined for AC motor drive applications. Critical evaluation of representative topologies is based on simulation and waveform analysis to characterize current/voltage stress of components, control timing constraints and feasibility. A special concern over inverter common-mode voltage and voltage gradient du/dt limitation capacity is discussed for motor bearing...
-
Quasi-resonant DC-link voltage inverter with enhanced zero-voltage switching control
PublicationA new topology modification of the parallel quasi-resonant circuit for a dc-link voltage inverter enables regulation of the zero voltage dc-link subperiods and the dc-link voltage gradient settings. The proposed circuit is based on four MOSFET switches with free-wheeling diodes for controlled quasi-resonant recharging between L-C tank in order to assure inverter zero voltage switching (ZVS) conditions. Design optimization of the...
-
Voltage and Reactive Power Load Flow Optimization in the Power System Using Fuzzy Logic
PublicationThe paper presents issues related to voltage control in the power system. An original method of reactive power flow optimization is considered, which leads to improved voltages in the power system and reduced active power losses. The optimization method is based on a procedure that employs fuzzy logic and is supported by a gradient search algorithm. The method has been implemented in PLANS software and verified.
-
A Five-Leg Three-Level Dual-Output Inverter
PublicationClassical 3-level dual-output inverter, 3-L DOI, involves two similar 3-level inverters that provides a pair of 3-phase output voltages with same or different frequencies from common input voltage source. Flexibility of either operation of the constituting inverters is evident in this DOI; but total duplication of power switches is a major drawback. State of the art coupled 3-L DOIs reduce this drawback by providing series-shared...
-
Reducing common mode voltage and bearing currents in quasi - resonant DC - link inverter
PublicationIn the paper, a concept of separation of an inverter-fed induction motor drive from its mains supply by two transistor switches inserted in the dc-link circuit is reexamined based on the proposed parallel quasi-resonant dc-link inverter (PQRDCLI). The objective of the paper is to show an advantage of the proposed topology in limiting high frequency common mode voltage and bearing currents. In the laboratory setup, an induction...
-
Modeling of a Quasi-Resonant DC Link Inverter Dedicated to Common-Mode Voltage and Ground Current Reduction
PublicationIn this paper, the modeling methodology of the AC drive system with a Parallel Quasi-Resonant DC Link Inverter (PQRDCLI) is described. A presented modeling approach is an attractive tool used for the effective evaluation of a common-mode (CM) voltage and grounds current reduction methods. Designed models of inverter, induction machine (IM), and cable are simple, thus the methods for parameter extraction are not complicated. Verification...
-
Computer-aided Analysis of Induced Sheath Voltages in High Voltage Power Cable System
PublicationThis paper concerns the effect of configuration of high voltage power cables on induced voltages in their metallic sheaths. One, two or three cables per phase and phase sequence of the cables are considered. Computing of the voltages was performed for a normal operation and in case of earth fault. Various ways of the sheaths bonding are considered as well. Shock hazard and voltage stress of non-metallic outer sheath of cables are...
-
Broadband Modeling of Motor Cable Impact on Common Mode Currents in VFD
PublicationExamination of conducted EMI generation and propagation in AC motor drives fed by frequency converter requires to consider parasitic capacitances in converters, motor windings and feeding cables to be taken into account. AC motor winding voltage transients and related common mode currents are significantly correlated with resonance effects occurring in converter's load circuits. Intensity levels of these phenomena depend...
-
Safety issues referred to induced sheath voltages in high-voltage power cables – case study
PublicationLoad currents and short-circuit currents in high-voltage power cable lines are sources of the induced voltages in the power cables’ concentric metallic sheaths. When power cables operate with single-point bonding, which is the simplest bonding arrangement, these induced voltages may introduce an electric shock hazard or may lead to damage of the cables’ outer non-metallic sheaths at the unearthed end of the power cable line. To...
-
Analysis of Induced Voltages and Power Losses in High Voltage Power Cables for Selected Methods of Cables Sheaths Bonding
PublicationPower is increasingly supplied to city centres with 110 kV cable lines. This is a convenient way to supply power, and practically the only one possible in areas of dense urban development. A high-voltage cable contains a coaxial metallic sheath, in which in normal operation and in fault conditions (during short-circuits) significant line-to-earth voltages can be induced, which threatens electric shock and/or damage to the cable’s...
-
Modeling of Common Mode Currents Induced by Motor Cable in Converter Fed AC Motor Drives
PublicationInvestigation of conducted EMI generation in AC motor fed by pulse width modulated frequency converters requires to consider parasitic capacitances in converters, motor windings and feeding cables to be taken into account. Motor voltage transients and related common mode currents are significantly correlated with resonance effects occurring in load circuits. An analysis of frequency converter load impedance-frequency characteristics...
-
Spatio-temporal filtering for determination of common mode error in regional GNSS networks
PublicationThe spatial correlation between different stations for individual components in the regional GNSS networks seems to be significant. The mismodelling in satellite orbits, the Earth orientation parameters (EOP), largescale atmospheric effects or satellite antenna phase centre corrections can all cause the regionally correlated errors. This kind of GPS time series errors are referred to as common mode errors (CMEs). They are usually...
-
Output voltage, current and DC-link voltages under SVPWM, experimental results
Open Research DataThe dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The output line-to-line voltage, output current and DC-link voltages were included. The comparison studies between proposed Space Vector Pulse-Width...
-
Output voltage, current and DC-link voltages under SPWM, experimental results
Open Research DataThe dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The output line-to-line voltage, output current and DC-link voltages were included. The Carrier-Based Pulse-Width Modulation (CBPWM) technique was...
-
Motor Cable Effect on the Converter Fed AC Motor Common Mode Current
PublicationAnaliza zaburzeń elektromagnetycznych przewodzonych w przekształtnikowych układach napędowych wymaga uwzględniania pojemności pasożytniczych występujących w przekształtniku, uzwojeniach silnika oraz kablu zasilającym silnik. Dynamiczne zmiany napięć na uzwojeniach silników zasilanych z przekształtników częstotliwości PWM oraz związane bezpośrednio z nimi składowe wspólne prądów zaburzeń przewodzonych są istotnie związane z zjawiskami...
-
Self-testing of fully differential multistage circuits using common-mode excitation
PublicationPrzedmiotem artykułu jest, zorientowane na uszkodzenia, testowanie wielostopniowych układów w pełni różnicowych. Zaproponowano metodę testowania z zastosowaniem pobudzenia układu testowanego sygnałem wspólnym. Rozważane są dwa warianty metody. Pierwszy wariant wykorzystuje do pobudzenia wejście każdego różnicowego stopnia. Drugi wariant wykorzystuje dodatkowe wejście wzmacniacza operacyjnego i testuje wielostopniowy układ bez jego...
-
Dynamic range comparison of voltage-mode and current-mode state-space Gm-Cbiquad filters in reciprocal structures
PublicationW pracy dokonano porównania zakresu dynamicznego bikwadratowych filtrówGm-C zmiennych stanu, których struktury układowe oparte są na zasadzie tran-sformacji układu dołączonego. Przeprowadzono rozważania teoretyczne w wynikuktórych określono ogóne formuły zakresu dynamicznego dla klasy filtrów Gm-Ctrybu napięciowego i prądowego. Weryfikacja rezultatów teoretycznych byłazrealizowana za pomocą symulatora SPICE.
-
The extended model predictive-sliding mode control of three-level AC/DC power converters with output voltage and load resistance variations
Publication -
Five-phase induction motor drive with sine-wave filter
PublicationThe paper presents closed loop ac drive with 5 phase induction motor operating with voltage source inverter and sine wave filter. The motor supply voltages and currents have sinusoidal shape. For well known adjustable electric drives the field oriented control method with flux and speed co ntrol can be applied. In the presence of output filter both control and estimation algorithms should be modified due to sine wave filter installation....
-
Low-Voltage LDO Regulator Based on Native MOS Transistor with Improved PSR and Fast Response
PublicationIn this paper, a low-voltage low-dropout analog regulator (ALDO) based on a native n-channel MOS transistor is proposed. Application of the native transistor with the threshold voltage close to zero allows elimination of the charge pump in low-voltage regulators using the pass element in a common drain configuration. Such a native pass transistor configuration allows simplification of regulator design and improved performance,...
-
Multi-transformer primary-side regulated flyback converter for supplying isolated IGBT and MOSFET drivers
PublicationThis paper presents primary-side voltage regulated multi-transformer quasi-resonant flyback converter (MTFC) for supplying isolated power switch drivers. The proposed topology offers distinct advantages over frequently used flyback converter possessing one high frequency transformer with isolated multiple outputs. Particularly, when a large number of separate dc supply units is required, then MTFC enables improved regular distribution...
-
Impact of configuration of earth continuity conductor on induced sheath voltages in power cables
PublicationIn high voltage power cable systems a problem of induced sheath voltages exist. Due to these voltages electric shock and damage of non-metallic outer sheath of the cables may occur. Exposure to voltage of the outer sheath may be very high in case of earth fault with high value of earth current. In order to reduce induced sheath voltages an earth continuity conductor (conductors) along power cables is applied. Configuration of this...
-
EMI attenuation in a DC-DC buck converter using GaN HEMT
PublicationA dc-dc buck converter using gallium nitride (GaN) high electron mobility transistors (HEMT) is experimentally investigated at the discontinuous current mode (DCM) and at the triangular current mode (TCM) operation. The paper objective is to specify the power conversion efficiency and attenuation of common mode (CM) and differential mode (DM) noise voltage, measured at the line impedance stabilization network (LISN) for compared...
-
Niekorzystny wpływ przekształtnikowego zasilania PWM na silniki asynchroniczne trakcyjne
PublicationThe electric traction drives with an AC motor fed by a frequency converter are used more and more often nowadays. The most significant side effects, of a converter's output voltage forming PWM method for AC motor windings, are steep voltage changes, which can initiate several destructive phenomena. The paper presents the adverse influence of a converter common mode voltage on the motor windings' increased voltage exposure and the...
-
Destructive impact of PWM inverters on traction AC motors
PublicationThe electric traction drives with an AC motor fed by a frequency converter are used more and more often nowadays. The most significant side effects, of a converter's output voltage forming PWM method for AC motor windings, are steep voltage changes, which can initiate several destructive phenomena. The paper presents the adverse influence of a converter common mode voltage on the motor windings's increased voltage exposure and...
-
Destructive Consequences of PWM Inverter Feeding for Traction AC Motors
PublicationThe electric traction drives with an AC motor fed by a frequency converter are used more and more often nowadays. The most significant side effects, of a converter's output voltage forming PWM method for AC motor windings, are steep voltage changes, which can initiate several destructive phenomena. The paper presents the adverse influence of a converter common mode voltage on the motor windings' increased voltage exposure and the...
-
Space Vector Pulsewidth Modulation Strategy for Multilevel Cascaded H-Bridge Inverter With DC-Link Voltage Balancing Ability
PublicationSpace vector pulsewidth modulation (SVPWM) algorithms for cascaded H-bridge multilevel (CHB ML) inverter usually provide the possibility of using several combinations of active voltage vectors to generate the same output voltage vector. For preselected H-bridges, some of them may generate output voltages opposite to the assumed direction. This results in the change of the dc-link voltages of these H-bridges in the opposite direction...
-
A method of self-testing of analog circuits based on fully differential op-amps with theTCBF classifier
PublicationA new approach of self-testing of analog circuits based on fully differential op-amps of mixed-signal systems controlled by microcontrollers is presented. It consists of a measurement procedure and a fault diagnosis procedure. We measure voltage samples of a time response of a tested circuit on a stimulation of a unit step function given at the common-mode reference voltage input of the op-amp. The fault detection and fault localization...
-
Electrical Tree Growth Behavior Under AC and DC High Voltage in Power Cables
PublicationThis work investigates the impact of an applied AC and DC high voltage on the electrical tree behavior in extruded cross-linked polyethylene (XLPE) insulation based on simulation and experimental validation. Extensive partial discharge (PD) testing methods are being implemented for high voltage cables under AC voltage for monitoring their condition. However, these PD testing methods cannot be utilized for power cables under DC...
-
Space-vector pulsewidth modulation for a seven-level cascaded H-bridge inverter with the control of DC-link voltages
PublicationThe control strategy of DC-link voltages for a seven-level Cascaded H-Bridge inverter is proposed in this paper. The DC-link voltage balancing is accomplished by appropriate selection of H-Bridges and control of their duty cycles in Space-Vector Modulation (SVM) algorithm. The proposed SVM method allows to maintain the same voltage level on all inverter capacitors. Regardless of the balancing function, the...
-
Comprehensive distortion compensation of grid-connected inverter currents
PublicationThe paper presents a comprehensive approach to the compensation of phase current distortion of grid-connected power inverters. Four different sources of current distortion are addressed: imperfect grid synchronization caused by the distortion in the grid voltages, voltage fluctuations in the dc link, time delays in the estimation of grid voltages, and the distortion of inverter output voltages due to dead-time effects and related...
-
NARAŻENIA NAPIĘCIOWE SILNIKÓW INDUKCYJNYCH ZASILANYCH Z FALOWNIKÓW NAPIĘCIA
PublicationW artykule przedstawiono zagadnienia związane z narażeniami izolacji silników pracujących w układach napędowych z falownikami napięcia. Znaczne stromości napięć oraz zjawiska falowe w przewodach zasilających powodują przyspieszoną degradacje izolacji maszyn. Rozwiązaniem jest stosowanie filtrów biernych na wyjściu falownika.
-
Application of Analytic Signal and Smooth Interpolation in Pulse Width Modulation for Conventional Matrix Converters
PublicationThe paper proposes an alternative and novel approach to the PWM duty cycles computation for Conventional Matrix Converters (CMC) fed by balanced, unbalanced or non–sinusoidal AC voltage sources. The presented solution simplifies the prototyping of direct modulation algorithms. PWM duty cycles are calculated faster by the smooth interpolation technique, using only vector coordinates, without trigonometric functions and angles. Both...
-
Structure and the space vector modulation for a medium-voltage power-electronic-transformer based on two seven-level cascade H-bridge inverters
PublicationThis study presents the structure and the space vector pulse-width modulation (SVPWM) for power electronic transformer (PET) based on two seven-level cascade H-bridge (CHB) inverters. The DC links of CHB inverters are coupled with nine dual-active bridge (DAB) converters with medium-frequency transformers. The DC-link voltages are equalised with two methods – through the control of DAB voltages...
-
Compensation of Dead Time Effects for Shunt Active Power Filters
PublicationThe paper presents a comprehensive approach to the compensation of the grid current distortion for shunt active power filter systems. Four different sources of current distortion are addressed: imperfect grid synchronization caused by the distortion in the grid voltages, time delays in the estimation of compensating currents and grid voltages, fluctuations of the dc bus voltage, and the distortion of inverter output voltages due...
-
Comprehensive compensation of grid current distortion by shunt active power filters
PublicationThe paper presents a comprehensive approach to the compensation of grid current distortion in shunt active power filter systems. Four sources of current distortion are addressed: imperfect grid synchronization caused by the distortion in the grid voltages, time delays in the evaluation of grid voltages and computation of compensating currents, fluctuations of the dc bus voltage, and the distortion of inverter output voltages due...
-
Analysis of electromagnetic disturbances in DC network of grid connected building-integrated photovoltaic system
PublicationThis paper focuses on conducted electromagnetic interference (EMI) emissions and propagation in the DC network of grid connected building integrated photovoltaic (PV) system. The investigated PV system, consists of ten solar panels, cabling and the grid-connected one phase inverter. The EMI simulation model of the real PV system has been developed with the aid of impedance analyzer measurements of solar panels and the DC network...
-
Calculation of Induced Sheath Voltages in Power Cables – Single Circuit System versus Double Circuit System
PublicationThis paper presents comparison of values of induced sheath voltages in power cable metallic sheaths when one or two cables per phase are used. Calculation of voltages is performed for various phase sequences of the power cables. Three types of the sheaths bonding and earthing are considered. Shock hazard and voltage stress of non-metallic outer sheath of cables are evaluated. The proposed, optimal configuration of the power cable...
-
Voltage Source Power Line Conditioner for Applications in Local Supply Systems
PublicationThe paper presents the basic principles of operation of voltage source power line conditioners (VSPLC) as well as their energy and filtration properties. A 4-level cascade based Voltage Source Converter (VSC) is used as a voltage source. The advantages of this topology is relatively simple construction and simple way of balancing DC link voltages. Results of the theoretical and experimental investigations confirm good energetic...
-
DC-link voltage balancing in cascaded H-Bridge converters
PublicationIn the paper a DC-link voltage balancing strategy for multilevel Cascaded H-Bridge (CHB) converter is proposed. Presented solution bases on optimal choice of active vector durations in Space-Vector Pulse Width Modulation (SV-PWM). It makes it possible to DC-link voltages control and to properly generate the output voltage vector in the case of DC-link voltage unbalance. Results of simulation and experimental researches...
-
A predictive estimation based control strategy for a quasi-resonant dc-link inverter
PublicationIn this paper the predictive estimation based control strategy for a quasi-resonant dc link inverter (PQRDCLI) is developed. Instead of direct measurement of dc link input inverter current – its estimation with one step prediction is applied. The PQRDCLI fed induction motor, controlled with a predictive current estimation stabilized inverter output voltage slopes independently of load. Moreover, reduction of overvoltage spikes...
-
Diagnostics of zno varistors by means of nondestructive testing
PublicationStandard industrial testing of high-voltage varistors for surge arresters demands application of high voltages and intensive currents. Nondestructive methods for varistor quality and endurance evaluation have been proposed and described. They rely on the application of resonant ultrasound spectroscopy, electro-ultrasonic spectroscopy, noise measurement and nonlinearity testing at voltages lower than continuous operating range....
-
Cascaded Buck Hybrid Interlink Converter for Multiple-Input / Multiple-Output Operation
PublicationThe provision of isolated- and non-isolated DC output voltages by Power electronics power-conditioning devices in the recent ‘green-energy-revolution’ era is on course. In this paper, a structure for multi-input multi-output(MIMO) DC–DC buck converter is proposed to generate output voltages of varying levels with fewer component-count. The DC output voltage of each of the constituting buck converters can be used independently or...
-
Optimized Space Vector Modulation strategy for five phase voltage source inverter with third harmonic injection
PublicationThis paper presents a simple and an effective SVM algorithm for five-phase Voltage-Source Inverters with the possibility to control independently the voltage vectors for fundamental and auxiliary orthogonal subspaces. The essential benefit is that output voltage is generated using only four active voltage vectors with limited numbers of switching. In the proposed solution, four active vectors are arbitrary chosen, independent of...
-
Low frequency nois of supecapacitor
Open Research DataDataset contains results of low frequency noise observation during discharge of commercially available supercapacitor, type DRL 2.7V 10F, with a nominal capacitance 10 F and a nominal voltage 2.7 V. Supercapacitor was charged to various voltages and discharged through a resistor. In the experiment the 50 Ohm and 200 Ohm resistors were used. The supercapacitor...
-
Power Converter Solutions for Industrial PV Applications—A Review
Publication: As the use of photovoltaics becomes more widespread, new technologies for more efficient energy generation, transmission, and distribution based on power electronics converters are being developed. The most common applications are grid-on, energy storage, hybrid, and high voltage gain applications. These applications impose several additional requirements in the design of power converters associated with the solar battery’s maximum...