Search results for: ELECTRODE DETECTION
-
Electrode arrays applicable to EIT based mine detection: a comparison ofspatial sensitivity distribution.
PublicationPrzebadano trzy konfiguracje matryc elektrodowych. Określono optymalne wzorce pobudzeń oraz odpowiadające im rozkłady czułości.
-
Reduced graphene oxide/iron(II) porphyrazine hybrids on glassy carbon electrode for amperometric detection of NADH and L-cysteine
Publication -
Electrochemical detection of bacterial endotoxin lipopolysaccharide (LPS) on gold electrode modified with DAL-PEG-DK5-PEG-OH - Antimicrobial peptide conjugate
PublicationThis work describes fabrication of gold electrodes modified with peptide conjugate DAL-PEG-DK5-PEG-OH that enables ultra-sensitive detection of lipopolysaccharide (LPS) isolated from the reference strain of Escherichia coli O26:B6. The initial step of the established procedure implies immobilization of the fully protected DAL-PEG-DK5-PEG-OH peptide on the surface of the gold electrode previously modified by cysteamine. Then side...
-
Caffeine detection using CB-PLA electrode after Nd:YAG laser ablation in He atmosphere
Open Research DataThe dataset contains electrochemical studies in form of cyclic voltammetry (CV) and differential pulse voltammetry (DPV) of laser-activated 3D printed CB-PLA electrodes. The ablation of the 3D-printed CB-PLA electrodes was carried out using a pulsed LaserBlast 500 Nd:YAG laser (Quantel, France) operating at 1064 nm and a 6 ns pulse duration.
-
High resolution XPS analysis of BDD electrode functionalization steps towards SARS-CoV-2 detection
Open Research DataThis dataset contains the results of the high-resolution XPS analyses of a set of boron-doped diamond (BDD) electrodes after consecutive functionalization steps toward anchoring of a receptor capable of SARS-CoV-2 virus detection. The analysis was carried out in the binding energy range of C1s, N1s, O1s, Ni2p3/2. The measurements were carried out on...
-
Application of bismuth film electrode for determination of heavy metals by stripping voltammetry
PublicationWhen Wang's research group introduced a new type of a working electrode: bismuth film plated electrode (BiFE), it has started attracting increasing attention in the field of electrochemical stripping analysis. These electrodes are shown to be very attractive alternative to common mercury-based electrodes, which are predominantly used in analysis of trace heavy metals.For the determination of heavy metals (Zn, Cd, Pb, Cu) used square...
-
Measurement of sub-nanometer molecular layers with ISFET without a reference electrode dependency
PublicationA new method of detection and measurement with sub-nanometer resolution of layers adsorbed or bonded to the ISFET's gate dielectric was presented. The sensitivity of this method is high enough to detect even partial mono-layer covering. The transconductance measurement of the ISFET provides independence of the output signal from pH changes and the driving electrode electrochemical potential instabilities. The stable reference electrode...
-
Comparison of the paracetamol electrochemical determination using boron-doped diamond electrode and boron-doped carbon nanowalls
PublicationTwo different type of electrodes, boron-doped diamond electrode (BDD) and boron-doped carbon nanowalls (B:CNW) electrode, were used for the electrochemical determination of paracetamol using the cyclic voltammetry and the differential pulse voltammetry in phosphate buffered saline, pH = 7.0. The main advantage of these electrodes is their utilization without any additional modification of the electrode surface. The peak current...
-
Non-Contact Monitoring of ECG in the Home Environment—Selecting Optimal Electrode Configuration
PublicationCapacitive electrocardiography (cECG) is most often used in wearable or embedded measurement systems. The latter is considered in the paper. An optimal electrocardiographic lead, as an individual feature, was determined based on model studies. It was defined as the possibly highest value of the R-wave amplitude measured on the back of the examined person. The lead configuration was also analyzed in terms of minimizing its susceptibility...
-
Electrochemical glucose sensor based on the glucose oxidase entrapped in chitosan immobilized onto laser-processed Au-Ti electrode
PublicationThe study on novel electrode material composed of structured titanium foil with embedded Au nanoparticles and modified with chitosan with entrapped glucose oxidase is presented. To confirm the successful immobilization of glucose oxidase FT-IR analysis was performed. The response of electrodes were tested towards glucose in the presence of different interference compounds and biological fluids. The prepared material exhibits excellent...
-
sp2-rich dendrite-like carbon nanowalls as effective electrode for environmental monitoring of explosive nitroaromatic
PublicationNitroaromatic compounds are commonly used explosive materials that pose a risk to human health and ecosystems due to their acute toxicity and carcinogenicity. Nitroaromatics have numerous pathways into the environment via discarded munitions (e.g. into the Baltic Sea after World War II), after use in mining operations, and in industrial run-off from factories producing these compounds (which are produced across the world to date)....
-
Ultrasensitive electrochemical determination of the cancer biomarker protein sPD-L1 based on a BMS-8-modified gold electrode
PublicationThis work describes the modification of a gold electrode with the BMS-8 compound that interacts with the Programmed Death-Ligand 1 (PD-L1), an immune checkpoint protein. The results show that we can confirm the presence of the sPD-L1 in the concentration range of 10−18 to 10−8 M using electrochemical impedance spectroscopy (EIS) with a limit of detection (LOD) of 1.87 × 10−14 M for PD-L1 (S/N = 3.3) and at a concentration of 10−14...
-
Jacek Ryl dr hab. inż.
PeopleI have obtained my PhD in chemical technology in 2010. In the same year, I was employed at the Department of Electrochemistry, Corrosion and Materials Engineering at the Faculty of Chemistry. In 2018 I received habilitation at the Faculty of Chemistry GUT in technical sciences in the discipline of chemical technology. From 2021, he was employed at the Institute of Nanotechnology and Materials Science at the Faculty of Technical...
-
Anna Danuta Dettlaff dr inż.
PeopleShe received her Master of Science degree in engineering with honours in 2013 at the Gdańsk University of Technology at the Department of Analytical Chemistry. In 2013-2017, she was a PhD student in the field of Chemical Technology at Faculty of Chemistry. Her doctoral dissertation was entitled “Nanocomposites based on conducting polymer and carbon materials for supercapacitor application”. In 2015, she was doing a three-month...
-
Electrohydrodynamic Flow Patterns in a Narrow Electrostatic Precipitator with Longitudinal Wire Electrode for Various Electrode Geometries
PublicationRecently narrow electrostatic precipitators (ESPs) have become a subject of interest because of their possible application in diesel engines. In this paper results of 2-dimensional (2D) Particle Image Velocimetry (PIV) measurements of the flow patterns in a narrow ESP for a various electrode geometries are presented. The PIV measurements were carried out in the observation plane that is perpendicular to the ESP duct. The ESP was...
-
Conductive printable electrodes tuned by boron-doped nanodiamond foil additives for nitroexplosive detection
PublicationAn efficient additive manufacturing-based composite material fabrication for electrochemical applications is reported. The composite is composed of commercially available graphene-doped polylactide acid (G-PLA) 3D printouts and surface- functionalized with nanocrystalline boron-doped diamond foil (NDF) additives. The NDFs were synthesized on a tantalum substrate and transferred to the 3D-printout surface at 200 °C. No other electrode...
-
Estimation of electrode contact in capacitive ECG measurement
PublicationIn the paper a method of electrode’s contact estimation in capacitive electrocardiogram (CECG) is presented. Proposed solution allows estimation of contact quality for each individual electrode. This enables construction of multi-electrode CECG systems, where electrode pairs can be selected on the basis of the individual electrode contact quality.
-
Hybrid electrode materials for fast performance devices
PublicationEnergy storage devices such as Electrochemical Double Layer Capacitors and other types of the electrochemical capacitors require chemically stable, non-soluble, electrochemically active electrode materials compatible with appropriate electrolytes. Factors which determine their applicability are derived from so called electrochemical window of electroltes, nature of charge accumulation and their kinetics. On the other hand technological...
-
Multisine impedimetric probing of biocatalytic reactions for label-free detection of DEFB1 gene: How to verify that your dog is not human?
PublicationAlbert is a dog (Canis familiaris), but he does not realize this. Albert loves human food (and beer), watching movies on the internet, sleeping in bed, and more. But he should not do all these things. To convince him that, we have desinged a test procedure. The DEFB1 gene is unique to human species. Detecting its presence from saliva and in short periods may offer an advantage in the field of forensic medicine, and influence Albert’s...
-
Optical Detection of Ketoprofen by Its Electropolymerization on an Indium Tin Oxide-Coated Optical Fiber Probe
PublicationIn this work an application of optical fiber sensors for real-time optical monitoring of electrochemical deposition of ketoprofen during its anodic oxidation is discussed. The sensors were fabricated by reactive magnetron sputtering of indium tin oxide (ITO) on a 2.5 cm-long core of polymer-clad silica fibers. ITO tuned in optical properties and thickness allows for achieving a lossy-mode resonance (LMR) phenomenon and it can be...
-
A novel hierarchically-porous diamondized polyacrylonitrile sponge-like electrodes for acetaminophen electrochemical detection
PublicationA novel composite electrode material consisting of tangled fibrous polyacrylonitrile-based hierarchically-struc- tured nanocomposites has been produced by wet-spinning, carbonized and decorated with a carbon nano- architecture by microwave plasma-enhanced chemical vapor deposition and investigated as a metal-free electrode for the enhanced electrochemical detection of acetaminophen. Surprisingly, the hierarchical fiber ar- chitecture...
-
3D polypyrrole structures as a sensing material for glucose detection
PublicationIn this work, 3D polypyrrole (PPy) structures as material for glucose detection is proposed. Polypyrrole was electrochemically polymerized on platinum screen-printed electrode from an aqueous solution of lithium perchlorate and pyrrole. The growth mechanism of such PPy structures was studied by ex-situ scanning electron microscopy. Preliminary studies show that studied here PPy film is a good candidate as a sensing material for...
-
Influence of electrode size on a Jacobian properties.
PublicationW pracy oceniono wpływ geometrii elektrod na jakość obrazowania za pomocą TEI. W tym celu określono zależność pomiędzy uwarunkowaniem Jakobianu a geometrycznymi rozmiarami zastosowanych elektrod.
-
Enhanced stability of electrochemical performance of few-layer black phosphorus electrodes by noncovalent adsorption of 1,4-diamine-9,10-anthraquinone
PublicationIn this paper, the novel noncovalent functionalisation strategy of few-layer black phosphorus by 1,4-diamine-9,10-anthraquinone electrode was proposed and studied. The degradation of few-layer black phosphorus under exposure to oxygen and water is a significant obstacle to its use as an electroanalytical electrode. The anthraquinone compound adsorbed at black phosphorus flakes results in improved prevention of the phosphorus surface...
-
Potentiometric Oxygen Sensor with Solid State Reference Electrode
PublicationThe concentration or the partial pressure of oxygen in an environment can be determined using different measuring principles. For high temperature measurements of oxygen, ceramic-based sensors are the most practical. They are simple in construction, exploration and maintenance. A typical oxygen potentiometric sensor consists of an oxygen ion conducting solid electrolyte and two electrodes deposited...
-
Electrochemical determination of neurotransmitter serotonin using boron/nitrogen co-doped diamond-graphene nanowall-structured particles
PublicationElectrode fouling is a major issue in biological detection due to the adhesion of the protein itself and polymerization of biomolecules on the electrode surface, impeding the electron transfer ability and decreasing the current response. To overcome this issue, the use of anti-fouling material, especially boron-doped diamond (BDD) electrode, is an alternative way. However, the electrocatalytic activity of BDD is inadequate compared...
-
Optimal configuration of an electrode array for measuring ventricles' contraction
PublicationAn influence of an electrode-array configuration on an impedance signal composition for a fixed spatial distribution of its sources is examined in the paper. The Finite Element Method and Geselowitz relationship were used for examining three different electrode-arrays. A sensitivity approach was used to evaluate each configuration assuming that localization of the signal source is known. A conductivity change, thus the source of...
-
A rapid-response ultrasensitive biosensor for influenza virus detection using antibody modified boron-doped diamond
PublicationAccording to the World Health Organization (WHO), almost 2 billion people each year are infected worldwide with flu-like pathogens including influenza. This is a contagious disease caused by viruses belonging to the family Orthomyxoviridae. Employee absenteeism caused by flu infection costs hundreds of millions of dollars every year. To successfully treat influenza virus infections, detection of the virus during the initial development...
-
VOLTAMMETRIC DETERMINATION OF DEOXYRIBONUCLEIC ACID PRESENCE ON A CARBON ELECTRODE
PublicationThis paper presents a voltammetry as a useful method to analyse DNA from different species. This electrochemical method is well know and used in different analyses. The influence of an area of working electrode and the capacity component, is shown at equals and the measurement. In voltammetry DNA measurement the capacity component is very important and must be taken into consideration. All mathematical analyses were verify at laboratory.
-
Instantaneous electrochemical impedance spectroscopy of electrode reactions
Publication -
Continuous‐Frequency Method of Measurement of Electrode Impedance
Publication -
Continuous frequency method of measurement of electrode impedance.
PublicationPrzedstawione zostały matematyczne podstawy nowej metody pomiaru impedancji elektrodowej. Metoda wykorzystuje sygnał pobudzenia którego częstotliwość zmienia się liniowo w czasie. Amplituda sinusoidalnego niestacjonarnego pobudzenia jest stała. Zapis i analiza sygnału pobudzenia i odpowiedzi pozwalana wyznaczenie ciągłego widma impedancyjnego. Jednoczesna analiza czasowo częstotliwościowa wykonano została przy użyciu transformacji...
-
Instantaneous electrochemical impedance spectroscopy of electrode reactions.
PublicationUstalona została ciągła transformata STFT sinusoidalnego sygnału pobudzeniai odpowiedzi prądowej dla pierwszorzędowej reakcji elektrodowej. Impedancja elektrodowa wyznaczona została w łącznej dziedzinie czasowo-częstotliwościowej. Wykonano pomiary reakcji redukcji Cd(II) na kapiącej elektrodzie rtęciowej w funkcji czasu. Zaprezentowano możliwość wyznaczania chwilowych widm impedancyjnych. Opisano czasowe charakterystyki rezystancji...
-
Investigation of Narrow Electrostatic Precipitator with Wire Multi-Electrode
PublicationDiesel engines emit fine particles, which are harmful to human and animal health. There are several methods for decrease particulate emission from a diesel engines, but up to now, these methods are notenough effective or very expensive. An electrostatic precipitation was proposed as an alternative method for control of a diesel particulate emission. Therefore, narrow electrostatic precipitators (ESPs) have become a subject of interest...
-
Properties of Nasicon-based CO2 sensor with Bi8Nb2O17 reference electrode
PublicationGas sensors are useful for the carbon dioxide concentration monitoring in many applications. The major challenge is to develop a potentiometric sensor working without the necessity of a reference gas and without a need of the reference electrode encapsulation. Important issue is a selection of reference electrode material, which should provide stable reference potential. For example as reference electrode material in sensor based...
-
Properties of Nasicon-based CO2 sensors with Bi8Nb2O17 reference electrode
PublicationPotentiometric CO2 sensors based on Nasicon (Na+ conductor, Na3Zr2Si2PO12) electrolyte, Bi8Nb2O17/Pt reference electrode and different sensing electrodes have been prepared. Besides the sensing electrode material, sensors differ from each other in the reference electrode preparation technique. The main aim of this study is to investigate sensor construction and electrode fabrication process influence on sensor properties. The optimal...
-
Influence of titanium layer on counter electrode on electrical parameters of DSSC
PublicationIn this paper the influence of the Ti layer thickness at counter-electrode on electrical parameters of DSSCs was examined. The transparent conductive oxide – less (TCO-less) counter electrodes (CE) with titanium layers and platinum as catalyst on Bk7 glass were prepared. Thin metallic films were deposited by means of magnetron sputtering (titanium) and Pulsed Laser Deposition (platinum). The counter electrode with Pt layer on Fluorine...
-
Size-controlled synthesis of gold nanoparticles by a novel atmospheric pressure glow discharge system with a metallic pin electrode and a flowing liquid electrode
Publication -
comparison of circular and rectangular narrow esps with longitudinal wire electrode
PublicationDiesel engines emit fine particles, which are harmful to human and animal health. There are several methods for decrease particulate emission from a diesel engines, but up to now, these methods are not enough effective or very expensive. An electrostatic precipitation was proposed as an alternative method for control of a diesel particulate emission. Therefore, narrow electrostatic precipitators (ESPs) have become a subject of...
-
Influence of electrode geometric arrangement on the operation of narrow circular electrostatic precipitator
PublicationIn this work the influence of electrode geometric arrangement on the operation of a circular electrostatic precipitator (ESP) was investigated using Particle Image Velocimetry (PIV) method. The ESP was a glass circular cylinder (29 mm in diameter, 300 mm long) equipped with a wire discharge electrode and circular-cylinder collecting electrode. The stainless-steel discharge wire electrode (0.23 mm in diameter, 100 mm long) was mounted...
-
Frequency dispersion of harmonic components of the current of an electrode process
Publication -
Fundamental-harmonic impedance of first-order electrode reactions
Publication -
Determination of electrode impedance by means of exponential chirp signal
Publication -
Spatial sensitivity to the conductivity changes of a four electrode probe.
PublicationW artykule rozważana jest czułość przestrzenna, czteropunktowej, liniowej sondy na zmiany przewodności zachodzące w badanym materiale. Otrzymane wyniki wskazują, że czułość może być zarówno dodatnia i ujemna, tzn. wzrost przewodności może prowadzić zarówno do wzrostu lub do spadku mierzonej impedancji. W artykule rozważane są materiały zarówno izotropowe jak i anizotropowe. Uzyskane wyniki pozwalają wyjaśnić dlaczego niektóre...
-
Determination of electrode impedance by means of exponential chirp signal.
PublicationPrzedstawiona została nowa metoda pomiaru impedancji elektrodowej. Jako pobudzenie zastosowany został niestacjonarny sygnał napięciowy, którego częstotliwość jest ekspotencjalną funkcją czasu. Zastosowanie zmodyfikowanej któtko-czasowej transformaty Fouriera (STFT) w analizie napięciowego pobudzenia i odpowiedzi prądowej pozwala na otrzymanie widma impedancyjnego.
-
Functionalization of electrode surfaces with monolayers of azocompounds and gold clusters.
PublicationWłaściwości monowarstw z azokoron na powierzchni złota były badane przy pomocy woltametrii i STM. Powierzchnia przypadająca na cząsteczkę została wyznaczona przy pomocy woltametrii i wynosi 0,65 nm kwadratowych. Wartość ta jest zgodna z wyznaczoną w oparciu o monowarstwę utworzoną na granicy powietrze-woda techniką Langmir-Blodgett. Tworzenie się klasterów złota i innych struktur obserwowano przy pomocy STM w przypadku gdy złota...
-
A probe for immittance spectroscopy based on the parallel electrode technique.
PublicationW pracy zaprezentowano konstrukcję sondy do spektroskopowych pomiarów immitancyjnych. Obliczono jej stałą, którą to wartość zweryfikowano eksperymentalnie. Pokazano przykładowe wyniki pomiarów in vivo.
-
The interference between electrode and poly(ethylene oxide) electrolytes
PublicationSpektroskopia impedancyjna zastosowana została do scharakteryzowania granicy faz elektroda-elektrolit poli(oksyetylenowy) zawierający sole litu. Udział rozpuszczalnika w pojemności wewnętrznej warstwy, Cs(σ), dla CH3(OCH2CH2 )nOCH3 DLA N=4,8,10 oraz dla PMEO [(CH2CH2O)mCH2O]m m=5-10 został wyznaczony z wartości pojemności warstwy sztywnej pomniejszonej o udział metalu CM. Wyznaczono wartość pojemności dipolowej Ci(dip) dla PEO...
-
An active electrode for mixed measurement techniqes, with application to EIT
PublicationW pracy przedstawiono budowę elektrody aktywnej wraz z opisem procedur pomiarowych prowadzących do poprawy stosunku sygnał-szum. Elektroda zbudowana jest w technice cyfrowo analogowej.
-
Carbon Based Electrode Materials and their Architectures for Capacitive Deionization
Publication