Accuracy Analysis of Determination the Vertical Displacements in Unstable Reference System
PublicationMeasurements of horizontal and vertical displacements are carried out mostly based on reference points identified as fixed. In surveying practice there may be some situations in which there is not possible to perform the measurements with reference to stable points or the difficulties in identification of points’ stability may arise. Accuracy analysis based on the covariance matrices have a special role in this process. In presented...
-
Application ofMsplitestimation to determine control points displacements in networks with unstable reference system
Publication -
The Use of Free Adjustment and Msplit-Estimation for Determination of the Vertical Displacements in Unstable Reference System
PublicationThe problem of the determining of the displacements of engineering objects and their surroundings is the current and important issue in the field of engineering geodesy. Most control measurements are made in relation to reference points (stable points). On the other hand, sometimes it happens that it is not possible perform the measurements with reference to the stable points or identification of stable points is difficult. Therefore,...
-
Identification of Unstable Reference Points and Estimation of Displacements Using Squared Msplit Estimation
PublicationThe article presents a new version of the method for estimating parameters in a split functional model, which enables the determination of displacements of geodetic network points with constrained datum. The main aim of the study is to present theoretical foundations of Msplit CD estimation and its basic properties and possible applications. Particular attention was paid to the efficacy of the method in the context of geodetic...
-
DiSTFAG method robust to gross errors in monitoring displacements and strains in unstable reference systems
PublicationThe DiSTFA method (Displacements and Strains using Transformation and Free Adjustment) was presented in Kamiński (2009). The method has been developed for the determination of displacements and strains of engineering objects in unstable reference systems, as well as for examining the stability of reference points. The DiSTFAG (Gross errors) method presented in the paper is the extension of the DiSTFA method making it robust to...
-
Determination of vertical displacements by using the hydrostatic levelling systems with the variable location of the reference sensor,
PublicationAbstract: In this paper, the author proposed a new method for determination of vertical displacements with the use of hydrostatic levelling systems. The traditional method of hydrostatic levelling uses a rule in which a position of reference sensor is stable. This assumption was not adapted in the proposed method. Regarding the issue mentioned above, the reference sensor is treated in the same way as the others sensors that measure...
-
DETERMINATION OF VERTICAL DISPLACEMENTS IN RELATIVE MONITORING NETWORKS
PublicationThe problem of determining displacements of objects is an important and current issue, in particular in terms of operational safety. This is a requirement that covers geodetic, periodic control measurements in order to determine horizontal and vertical displacements. The paper is focused on the analysis of vertical displacements. Geodetic measurements and their interpretation allow to reduce the risk of possible structural catastrophes....
-
The Concept of Accuracy Analysis of the Vertical Displacements Gained from the Hydrostatic Levelling Systems’ Measurements
PublicationAbstract: Nowadays, hydrostatic levelling is a widely used method for the vertical displacements’ determinations of objects such as bridges, viaducts, wharfs, tunnels, high buildings, historical buildings, special engineering objects (e.g., synchrotron), sports and entertainment halls. The measurements’ sensors implemented in the hydrostatic levelling systems (HLSs) consist of the reference sensor (RS) and sensors located on the...
-
Reference FEM model for SHM system of cable-stayed bridge in Rzeszów
PublicationThe paper presents the references model for structural health monitoring system (SHM) of cable-stayed bridge recently constructed in Rzeszów over Wisłok River. The SHM system is design to provide on-line information on the structure state and facilitate its maintenance procedures. The main feature of the SHM system is permanent observation of the dynamic behavior of the bridge with focus on cable vibrations. The paper discusses...
-
Devices for the production of reference gas mixtures
PublicationFor many years there has been growing demand for gaseous reference materials, which is connected with development in many fields of science and technology. As a result, new methodological and instrumental solutions appear that can be used for this purpose. Appropriate quality assurance/quality control (QA/QC) must be used to make sure that measurement data are a reliable source of information. Reference materials are a significant...
-
Investigation of the impact of ITRF2014/IGS14 on the positions of the reference stations in Europe
PublicationIn January 2017, the new realization of the International Terrestrial Reference Frame (ITRF) – ITRF2014, was released. Besides the higher accuracy and consistency of the new frame, an entirely new element – the post seismic deformation - was included. Moreover, the definition of the fundamental points has also been changed. All changes related to the new reference frame haveconsequences in the precise positioning using GNSS observations....
-
Reference Librarian
Journals -
Automated Generation of Modular Assurance Cases with the System Assurance Reference Model
PublicationAssurance cases are structured arguments used to demonstrate specific system properties such as safety or security. They are used in many industrial sectors including automotive, aviation and medical devices. Assurance cases are usually divided into modules which address goals allocated to specific system properties, components, functions, modes of operation or environmental conditions. Depending on the system and assurance process...
-
Development of the System Assurance Reference Model for Generating Modular Assurance Cases
PublicationAssurance cases are structured arguments used to demonstrate specific system properties such as safety or security. They are used in many industrial sectors including automotive, aviation and medical devices. Larger assurance cases are usually divided into modules to manage the complexity and distribute the work. Each of the modules is developed to address specific goals allocated to the specific objects i.e. components of the...
-
Accuracy of marine gravimetric measurements in terms of geodetic coordinates of land reference benchmark
PublicationThe article presents how the values of (3D) coordinates of land reference points affect the results of gravimetric measurements made from the ship in sea areas. These measurements are the basis for 3D maritime inertial navigation, improving ships' operational safety. The campaign verifying the network absolute point coordinates used as a reference point for relative marine gravity measurements was described. The obtained values...
-
Corporate social responsibility in reference to environmental statements within EMAS system in small and medium enterprises
PublicationAccording to the corporate social responsibility concept, organisations should apply any mechanisms available supporting their business actions contributing i.e. to the improvement of natural environment. Among them is EMAS eco-management and audit scheme. The prove of its implementation is environmental statement and entering the organisation into a national EMAS register. The aim of the statement is informing the society and...
-
Electrocatalytic gas sensor with reference layer
PublicationIn recent years electrochemical gas sensors based on solid state electrolytes have been intensively developed. They are easy to obtain, use and relative durable. Nasicon is one of the most promising materials, which have been used in construction of gas sensors. Most of these devices work in potentiometric or amperometric mode. However, some works are dedicated to sensors working in electrocatalytic mode. Principle of operation...
-
Electrocatalytic Gas Sensor with Reference Layer
PublicationThis paper presents studies of gas sensors prepared in ceramic technology with Nasicon as a solid electrolyte. Sensors work in the voltammetric mode thus based on the excitation of a sensor with a periodic potential signal while current response is recorded. The main aim is to investigate a Bi8Nb2O17 reference layer influence on sensor properties. Sensors I-V characteristics in different concentration of nitrogen dioxide have been...
-
Blurred quantum Darwinism across quantum reference frames
PublicationQuantum Darwinism describes objectivity of quantum systems via their correlations with their environment--information that hypothetical observers can recover by measuring the environments. However, observations are done with respect to a frame of reference. Here, we take the formalism of [Giacomini, Castro-Ruiz, & Brukner. Nat Commun 10, 494 (2019)], and consider the repercussions on objectivity when changing quantum reference...
-
Properties of Nasicon-based CO2 sensor with Bi8Nb2O17 reference electrode
PublicationGas sensors are useful for the carbon dioxide concentration monitoring in many applications. The major challenge is to develop a potentiometric sensor working without the necessity of a reference gas and without a need of the reference electrode encapsulation. Important issue is a selection of reference electrode material, which should provide stable reference potential. For example as reference electrode material in sensor based...
-
Person Tracking in Ultra-Wide Band Hybrid Localization System Using Reduced Number of Reference Nodes
PublicationIn this article a novel method of positional data integration in an indoor hybrid localization system combining inertial navigation with radio distance measurements is presented. A point of interest is the situation when the positional data and the radio distance measurements are obtained from less than thee reference nodes and it is impossible to unambiguously localize the moving person due to undetermined set of positional equations....
-
The importance and availability of marine certified reference materials
PublicationTraceability and reliable results are the two pillars of analytical methods; certified reference materials (CRMs) meet this requirement. ISO 17034:2016 credentials provide brief information on general requirements for the competence of Reference Material Producers (RMPs). The different types of CRMs have been produced in recent years for chemical analysis in food, water, soil, and sediment matrices in recent years. This review...
-
Potentiometric Oxygen Sensor with Solid State Reference Electrode
PublicationThe concentration or the partial pressure of oxygen in an environment can be determined using different measuring principles. For high temperature measurements of oxygen, ceramic-based sensors are the most practical. They are simple in construction, exploration and maintenance. A typical oxygen potentiometric sensor consists of an oxygen ion conducting solid electrolyte and two electrodes deposited...
-
Production of new non-matrix reference material of ethene
PublicationThe main objective of the research is to produce new non-matrix reference materials of ethene. The study are based on thermal decomposition of surface compound chemically bonded with the surface of glass fibers coated with thin layer of aluminum. Positivehomogeneity test, stability test and organization of inter-laboratory comparison are leading to find new non-matrix reference materials which are indispensable tools in the analysis...
-
The effect of tire aging on acoustic performance of CPX reference tires
PublicationReduction of tire/road noise is one of the biggest environmental challenges of road traffic. To reduce that noise it is necessary to perform acoustic measurements on the base of wellproven standard procedures. One method of measurements that is in common use, namely the Close Proximity Method (CPX), is described in standard ISO-DIS 11819-2. As this method is used to classify road surfaces regarding their influence on vehicle noise,...
-
GNSS reference solution for permanent sition stability monitoring and geodynamical investigations - the ASG-EUPOS case study
PublicationThe aim of this paper is to present the strategy of determination of the reference solution for the ASG-EUPOS (ActiveGeodetic Network – European Position Determination System) coordinate monitoring system. ASG-EUPOS is a network of permanent GNSS (Global Navigation Satellite System) stations controlled by the Polish Head Office of Geodesy and Cartography (HOGC), which main role is to realize the ETRS89 (European Terrestrial Reference...
-
Configuration of the reference stations as the element of national reference frame reliability
Publication -
AN ORIGINAL APPROACH IN THE FIELD OF PREPARATION REFERENCE MATERIALS OF VOLATILE ANALYTES
PublicationStandard gas mixtures (SGM) are indispensable reference materials for ensuring the reliability of analytical work. Reference materials are an excellent tool for the quality control and assurance of analytical results. Standard gas mixtures are unique among reference materials. The rapid progress of SGM production is connected with the instability of gaseous analytes which make them difficult to obtain. The use of standards with...
-
REFERENCE SERVICES REVIEW
Journals -
Reference Series in Phytochemistry
Journals -
Properties of Nasicon-based CO2 sensors with Bi8Nb2O17 reference electrode
PublicationPotentiometric CO2 sensors based on Nasicon (Na+ conductor, Na3Zr2Si2PO12) electrolyte, Bi8Nb2O17/Pt reference electrode and different sensing electrodes have been prepared. Besides the sensing electrode material, sensors differ from each other in the reference electrode preparation technique. The main aim of this study is to investigate sensor construction and electrode fabrication process influence on sensor properties. The optimal...
-
Non-matrix reference materials-the challenges in the preparation of standard gas mixtures
PublicationIn the last few years particularly great pressure is exerted on quality control and assurance of analytical measurement results. An invaluable role in this process is played by reference materials. The paper presents the characteristics of basic types of reference materials, with particular attention to gaseous reference materials.
-
Degradation of reference tyres used for CPX measurements
PublicationMeasurements of tyre/road noise using the Close Proximity Method are based on reference tyres that are described in ISO/TS 11819-3. The standard specifies two tyres, namely "P1" and "H1" that should be used during measurements. To be used for measurements each tyre must fulfill certain conditions that are listed in the standard. The conditions are related to the tread pattern depth and rubber hardness. During experiments performed...
-
Non-matrix reference matrials- chalanges in the preparation of standard gas mixtures
PublicationIn the last few years particularly great pressure is exerted on quality control and assurance of analytical measurement results. An invaluable role in this process is played by reference materials. The paper presents the characteristics of basic types of reference materials, with particular attention to gaseous reference materials. In addition, a review of literature on techniques of preparation of gaseous standard materials, published...
-
Novel Vision Monitoring Method Based on Multi Light Points for Space-Time Analysis of Overhead Contact Line Displacements
PublicationThe article presents an innovative vision monitoring method of overhead contact line (OCL) displacement, which utilizes a set of LED light points installed along it. A light point is an, LED fed from a battery. Displacements of the LED points, recorded by a camera, are interpreted as a change of OCL shape in time and space. The vision system comprises a camera, properly situated with respect to the OCL, which is capable of capturing...
-
Efficiency Increasing of No-reference Image Quality Assessment in UAV Applications
PublicationUnmanned aerial vehicle (UAV) imaging is a dynamically developing field, where the effectiveness of imaging applications highly depends on quality of the acquired images. No-reference image quality assessment is widely used for quality control and image processing management. However, there is a lack of accuracy and adequacy of existing quality metrics for human visual perception. In this paper, we demonstrate that this...
-
THE APPLICATION OF KALMAN FILTERING TO PREDICT VERTICAL RAIL AXIS DISPLACEMENTS OF THE OVERHEAD CRANE BEING A COMPONENT OF SEAPORT TRANSPORT STRUCTURE
PublicationAs the devices designed to transport materials, the overhead cranes should meet certain geometric requirements for their operation to be safe. The presently available geodetic equipment, in particular total stations, provides opportunities for precise 3D measurements of coordinates of the controlled points. These coordinates make a basis for correcting the height of crane runway axes. The paper presents a method to calculate position...
-
Standard gas mixtures- indispensable reference materials in the analysis of gaseous media
PublicationIn recent years the need for the quality control and assurance of analytical measurement results has been particularly strongly emphasised. Certified reference materials play an invaluable role in this process. The article characterises the basic types of reference materials, focusing in particular on those in the gaseous state. It also reviews the literature on the techniques of preparing standard gas mixtures over the last ten...
-
Standard gas mixtures- indispensable reference materials in the analysis of gaseous media
PublicationIn recent years the need for the quality control and assurance of analytical measurement results has been particularly strongly emphasised. Certified reference materials play an invaluable role in this process. The article characterises the basic types of reference materials, focusing in particular on those in the gaseous state. It also reviews the literature on the techniques of preparing standard gas mixtures over the last ten...
-
Self-optimizing narrowband interference canceller - can reference signal help?
PublicationSONIC (Self-Optimizing Narrowband Interference Canceller) is an acronym of the recently proposed active noise control algorithm with interesting adaptivity and robustness properties. SONIC is a purely feedback controller, capable of rejecting nonstationary sinusoidal disturbances (with time-varying amplitudes and/or frequencies) in the presence of plant (secondary path) uncertainties. We show that even though SONIC can work reliably...
-
Daylight metrics and requirements: A review of reference documents for architectural practice
PublicationDaylight has always been part of architectural practice since architects have used it to define spaces and create complex structures. Daylighting is, nowadays, seen as key strategy for sustainability, energy efficiency and resilience in buildings. This article aims to investigate daylight requirements in reference documents for architectural practice through the collection and qualitative analysis of documents. 117 reference documents...
-
Exploration of optical fibres as a carrier for new benzene and toluene matrix-free reference materials
PublicationTo meet high expectations concerning precision and accuracy of reference materials, preparation of matrixfree reference materials using thermal decomposition-gas chromatography-mass spectrometry (TD-GC-MS) was proposed in this study. In the paper, the results obtained in preparation of the new reference materials for benzene and toluene are presented, based on the thermal decomposition technique of compounds chemically bound to...
-
New First - Path Detector for LTE Positioning Reference Signals
PublicationIn today's world, where positioning applications reached a huge popularity and became virtually ubiquitous, there is a strong need for determining a device location as accurately as possible. A particularly important role in positioning play cellular networks, such as Long Term Evolution (LTE). In the LTE Observed Time Difference of Arrival (OTDOA) positioning method, precision of device location estimation depends on accuracy...
-
Method and system for disciplining a local reference oscillator by GPS 1PPS signal
Publication -
The application of TD-GC-FID technique for production of matrix-free reference materials
PublicationIn the last few years particular pressure is exerted on finding new analytical methods which would provide real possibilities of monitoring and control of the state of the environment. Intensive development of analytical techniques for measurements of gaseous media and the negative effects of BTX compounds make it necessary to produce new gaseous reference materials. To prepare the appropriate non- matrix reference material thermal...
-
Certified Reference Material - as a necessary tool for the quality control and quality assurance of measurements
PublicationReference materials are necessary to control and ensure the quality of the measurements. The demand for analytical information on the composition of different material objects makes it necessary to produce an even wider range of materials.
-
New matrix-free reference material for ethene in the form of optical fibres
PublicationReference materials are indispensable in the qualitycontrol and quality assurance of analytical measurements. Onenovel approach to the generation of standard gaseous mixturesof toxic, reactive, volatile, labile, and malodorous substancesinvolves thermal decomposition or rearrangement, under definedtemperature conditions, of compounds immobilized, bychemical bonding, on the surface of an appropriate carrier torelease specific amounts...
-
Improving the CPX method by specifying reference tyres and including corrections for rubber hardnes and temperature
PublicationRecently completed work in the EU project ROSANNE and in working group ISO/TC43/SC1/WG33 has allowed substantial improvements to measurements made by the Close-Proximity (CPX) method, intended for measurement of noise properties of road surfaces.The paper summarizes the experimental work and describes the conclusions and implementation in ISO/FDIS 11819-2 (CPX method) and in the supporting ISO (draft) Technical Specifications 11819-3...
-
Homogeneity study of candidate reference material (contaminated soil) based on determination of selected metals, PCBs and PAHs
PublicationReference materials (RMs) are an indispensable part of QA/QC system and have played a critical role in the continual expansion of analytical capabilities of the analytical laboratories. The homogeneity study of the candidate for reference material is essential for the quality of reference material (certified reference material) used in quality assurance activities. The homogeneity study of candidate for reference materials of contaminated...
-
Development of potential candidate reference materials for drugs in bottom sediment, cod and herring tissues
PublicationRegular use of a reference material and participation in a proficiency testing program can improve the reliability of analytical data. This paper presents the preparation of candidate reference materials for the drugs metoprolol, propranolol, carbamazepine, naproxen, and acenocoumarol in freshwater bottom sediment and cod and herring tissues. These reference materials are not available commercially. Drugs (between 7 ng/g and 32...