Filters
total: 741
filtered: 576
Search results for: POUNDING
-
Analysis of the effect of the seismic gap on the response of buildings experiencing pounding during earthquakes
PublicationThe aim of this paper is to investigate the effect of the seismic gap on the dynamic response of buildings experiencing earthquake-induced pounding. Three buildings have been analysed, which are 5-storey, 7-storey and 9-storey structures. Three possible pounding scenarios have been considered, which are pounding between 5-storey and 7-storey buildings, pounding between 5-storey and 9-storey buildings and pounding between 7-storey...
-
Direction-of-Arrival Estimation Methods in Interferometric Echo Sounding
PublicationNowadays, there are two leading sea sounding technologies: the multibeam echo sounder and the multiphase echo sounder (also known as phase-dierence side scan sonar or bathymetric side scan sonar). Both solutions have their advantages and disadvantages, and they can be perceived as complementary to each other. The article reviews the development of interferometric echo sounding array configurations and the various methods applied...
-
Selection of pointing device for elders
PublicationW artykule przedstawiono metodykę i sposób akwizycji oraz analizy danych dla doboru optymalnego urządzenia wskazującego, dostosowanego do osób starszych. Przedstawiono wyniki próbnych testów na dwóch grupach - docelowej i referencyjnej oraz skomentowano wyniki.
-
FEM analysis of earthquake-induced pounding between two buildings modelled by shell elements
PublicationW artykule przeprowadzono dokładną analizę zderzeń pomiędzy dwoma budynkami stosując metodę elementów skończonych z użyciem elementów powłokowych. Wyniki analizy pokazują, iż kolizje mogą prowadzić do znacznego zwiększenia odpowiedzi konstrukcji lżejszej, podczas gdy zachowanie się cięższego budynku jest jedynie nieznacznie zależne od efektu zderzeń. Wyniki te jednoznacznie wskazują, iż podczas projektowania na terenach sejsmicznych...
-
Assessment of damage due to earthquake-induced pounding between the main building and the stairway tower
PublicationRaporty po trzęsieniach ziemi pokazują, iż występujące podczas wstrząsów sejsmicznych zderzenia pomiędzy sąsiednimi konstrukcjami budowlanymi, lub ich częściami, mogą prowadzić do znacznych uszkodzeń lub nawet całkowitego zniszczenia konstrukcji. Celem niniejszego artykułu jest oszacowanie zakresu i intensywności zniszczeń na skutek zderzeń pomiędzy budynkiem głównym szpitala Olive View a wolnostojącą klatką schodową podczas trzęsienia...
-
Earthquake-induced pounding between equal height buildings with substantially different dynamic properties
PublicationZderzenia pomiędzy konstrukcjami budowlanymi podczas trzęsień ziemi mogą prowadzić do znacznych uszkodzeń czy nawet całkowitego zniszczenia. Celem niniejszego artykuły jest analiza zderzeń pomiędzy budynkami o jednakowej wysokości i różnych parametrach dynamicznych. W artykule przedstawiono wyniki badań numerycznych przeprowadzonych na nieliniowych modelach dyskretnych o skupionych masach z wykorzystaniem nieliniowego modelu lepkosprężystego...
-
Seismic probabilistic assessment of steel and reinforced concrete structures including earthquake-induced pounding
PublicationRecent earthquakes demonstrate that prioritizing the retrofitting of buildings should be of the utmost importance for enhancing the seismic resilience and structural integrity of urban structures. To have a realistic results of the pounding effects in modeling process of retrofitting buildings, the present research provides seismic Probability Factors (PFs), which can be used for estimating collision effects without engaging in...
-
Experimental determination of impact stiffness parameters for the non-linear viscoelastic model of pounding force
PublicationNieliniowy model lepko-sprężysty umożliwia dokładną symulację siły zderzenia w czasie oraz symulację odpowiedzi konstrukcji podatnej na zderzanie podczas trzęsień ziemi. Celem tego artykułu jest eksperymentalne wyznaczenie wartości współczynnika sztywności zderzenia jako parametru tegoż modelu.
-
Seismic pounding behavior of multi-story buildings in series considering the effect of infill panels
PublicationThe aim of the present paper is to study the influence of the infill panels on the seismic pounding response of adjacent structures in series. The contribution of the masonry infill has been simulated using equivalent diagonal compression struts. Steel frames have been assumed to have elastic-plastic behavior with 1% linear strain hardening. The dynamic contact analysis has been utilized where contact surface model (target and...
-
Study on polymer elements for mitigation of earthquake-induced pounding between buildings in complex arrangements
PublicationPounding between neighbouring buildings during earthquakes has been identified as one of the reasons for substantial damage or even total collapse of colliding structures, so it has been the subject of numerous studies in the recent years. A major reason leading to interactions between adjacent, insufficiently separated structures results from the differences in their dynamic properties. The problem is much more complicated for...
-
Study on Polymer Elements for Mitigation of Earthquake-Induced Pounding Between Buildings in Complex Arrangements
PublicationPounding between neighboring structures during seismic events has been revealed as one of the most commonly observed reasons for severe damage or even total collapse of the adjacent buildings. Therefore, pounding effects have recently become an issue of great interest of many numerical and experimental investigations in many earthquake-prone regions of the world. It has also been observed that the differences in dynamic characteristics...
-
Non-linear strain rate analysis of earthquake-induced pounding between steel buildings
PublicationPast and recent earthquakes have shown that ground motions may cause severe structural damage to civil engineering structures. Earthquake-induced pounding between adjacent buildings has been identified as one of the reasons which intensifies damages. The aim of this paper is to show the results of the detailed nonlinear FEM analysis of earthquake-induced pounding between two steel buildings. The elastic – perfectly plastic material...
-
Effects of Deck-Abutment Pounding on the Seismic Fragility Curves of Box-Girder Highway Bridges
PublicationEarthquake-induced pounding in bridges is a complex contact phenomenon in which the dynamic responses of structures, including collisions between deck and abutments, are strongly related to structural properties and earthquake excitation. The goal of this study is to develop and compare the seismic fragility curves of overall system and individual components of regular and irregular box-girder highway bridges in two cases: with...
-
Gdansk Bay sea bed sounding and classification of its results
PublicationThe main goal of this paper is to describe the results of sounding the Gdansk Bay sea bed by using a SES-2000 Standard parametric sub-bottom profiler. Quality of data obtained during trials depends inter alia on a proper location of transducer array to reduce influence of pitch, roll and heave motions as well as ship self noise (resulting from bubbles due to propeller and flow around hull, vibration generated by main engine and...
-
Predicting the seismic collapse capacity of adjacent SMRFs retrofitted with fluid viscous dampers in pounding condition
PublicationSevere damages of adjacent structures due to structural pounding during earthquakes have emphasized the need to use some seismic retrofit strategy to enhance the structural performance. The purpose of this paper is to study the influence of using linear and nonlinear Fluid Viscous Dampers (FVDs) on the seismic collapse capacities of adjacent structures prone to pounding and proposing modification factors to modify the median...
-
Experimental study on earthquake-induced pounding between structural elements made of different building materials
PublicationCelem artykułu jest pokazanie wyników dwóch eksperymentów dotyczących zderzeń pomiędzy elementami wykonanymi z różnych materiałów budowlanych, takich jak: stal, beton, drewno i ceramika. Pierwszy z nich polegał na zrzucaniu kul na płaską powierzchnię, drugi dotyczył zderzeń modeli konstrukcji poddanych wymuszeniom sejsmicznym na stole wstrząsowym. Wyniki testów pokazują, iż wpływ materiału elementów kolidujących ze sobą na zachowanie...
-
Analytical and experimental determination of parameters for the non-linear viscoelastic model of earthquake-induced structural pounding
PublicationNieliniowy model lepko-sprężysty umożliwia dokładną symulację siły zderzenia w czasie oraz symulację odpowiedzi konstrukcji podatnej na zderzanie podczas trzęsień ziemi. Jednym z celów niniejszego artykułu jest wyprowadzenie wzoru na zależność pomiędzy liczbą tłumienia zderzenia (parametr wspomnianego modelu), a współczynnikiem odbicia. Kolejnym celem jest wyznaczenie zakresu wartości współczynników odbicia oraz współczynników...
-
Preventing of earthquake-induced pounding between steel structures by using polymer elements – experimental study
PublicationPounding between two, or more, adjacent buildings during earthquakes has been identified as one of the reasons for substantial damage or even total collapse of colliding structures, so it has been the subject of numerous studies in the recent years. A major reason leading to interactions between adjacent, insufficiently separated structures results from the differences in their dynamic properties. A number of different methods...
-
Seismic pounding between adjacent buildings: Identification of parameters, soil interaction issues and mitigation measures
PublicationStructural pounding has been observed in many previous earthquakes due to insufficient gap commonly provided between adjacent structures. The collisions usually generate large impact forces and short duration acceleration pulses which may result in significant damage to the colliding buildings. Because of that, earthquake induced structural pounding has been intensively studied and investigated for the last three decades. Results...
-
Shaking table experimental study on pounding between adjacent structures founded on different soil types
PublicationThe aim of this study is to extensively investigate the effect of the soil type on the response of colliding structures based on shaking table experimental tests. Two single-storey models of steel buildings with different dynamic parameters were considered in this study. Three pounding scenarios were taken into account by applying different seismic gaps (0.5 cm, 1 cm and 1.5 cm as well as the no pounding case). First, the effect...
-
The Effectiveness of Rubber Bumpers in Reducing the Effects of Earthquake-Induced Pounding between Base-Isolated Buildings
PublicationTh e methods for preventing earthquake-induced structural pounding between two adjacent buildings include ensuring a sufficient separation distance between them or decreasing their relative displacement during seismic excitation. Some equations or even specific values of such gap sizes between two buildings have been introduced so as to avoid collisions. Increasing the stiffness of buildings, using tuned mass dampers, applying...
-
Seismic gap between buildings founded on different soil types experiencing pounding during earthquakes
PublicationSeveral formulas have been suggested in the literature to evaluate the minimum seismic gap that would prevent collisions between adjacent buildings during earthquakes, including those based on the absolute sum of the peak displacements (ABS), square root of the sum of the squares (SRSS), the double difference method (DDC), Australian code, and approach proposed by Naderpour et al. The aim of the present study is to evaluate the...
-
Predicting the seismic collapse capacity of adjacent SMRFs retrofitted with fluid viscous dampers in pounding condition
PublicationSevere damages of adjacent structures due to structural pounding during earthquakes have emphasized the need to use some seismic retrofit strategy to enhance the structural performance. The purpose of this paper is to study the influence of using linear and nonlinear Fluid Viscous Dampers (FVDs) on the seismic collapse capacities of adjacent structures prone to pounding and proposing modification factors to modify the median...
-
Optimum shapes and dimensions of rubber bumpers in order to reduce structural pounding during seismic excitations
PublicationLarge displacement of structures observed during seismic excitations may lead to collisions between two adjacent, insufficiently-separated buildings and may result in major damages of both of them. In many building codes, appropriate equations or approximately recommended distances between structures in order to avoid pounding hazard have been introduced. Unfortunately, further, more detailed considerations show that safety situation...
-
Time variable gain for long range sonar with chirp sounding signal
PublicationThe main purpose of applaying Time Variable Gain (TVG) in active sonars with digital signal processing is to reduce dynamic range of echo signal and adapt it to the dynamic range of the analogue to digital conversion. With high transmission losses level, the dynamic range of the input signal in long range sonars can be very high and even exceed 200dB. When chirp sounding signals with matched filtration are used, sonars can raech...
-
Processing data on sea bottom structure obtained by means of the parametric sounding
PublicationThe aim of the paper is to analyze data obtain during sounding of the Gdansk Bay by means of the parametric sonar. The accuracy of the sea bottom structure investigation needs the correct configuration of research equipment and the proper calibration of peripheral devices (GPS, heading sensor, motion sensor MRU-Z and navigation units) which provide necessary data to bathymetrical measurement system enabling its work with whole...
-
Sounding Mechanism of a Flue Organ Pipe—A Multi-Sensor Measurement Approach
PublicationThis work presents an approach that integrates the results of measuring, analyzing, and modeling air flow phenomena driven by pressurized air in a flue organ pipe. The investigation concerns a Bourdon organ pipe. Measurements are performed in an anechoic chamber using the Cartesian robot equipped with a 3D acoustic vector sensor (AVS) that acquires both acoustic pressure and air particle velocity. Also, a high-speed camera is employed...
-
Processing data on sea bottom structure obtained by means of the parametric sounding
PublicationThe aim of the paper is to analyze data obtained during sounding the Gdansk Bay sea bed by means of the parametric echo-sounder. The accuracy of the sea bottom structure investigation needs correct configuration of research equipment and proper calibration of peripheral devices (GPS, heading sensor, MRU-Z motion sensor and navigation instruments which provide necessary data to bathymetrical measurement system, enabling its work...
-
Transcriptomic responses to wounding: meta-analysis of gene expression microarray data
PublicationBackground A vast amount of microarray data on transcriptomic response to injury has been collected so far. We designed the analysis in order to identify the genes displaying significant changes in expression after wounding in different organisms and tissues. This meta-analysis is the first study to compare gene expression profiles in response to wounding in as different tissues as heart, liver, skin, bones, and spinal cord, and...
-
Counting Lattice Paths With Four Types of Steps
Publication -
Pounding mitigation of a short-span cable-stayed bridge using a new hybrid passive control system
PublicationThis paper investigates the effectiveness of a new hybrid passive control system on the seismic response of an existing steel cable-stayed bridge considering the pounding effect. The proposed hybrid passive control system comprises a seismic isolator and a metallic damper. The bridge is located in a high seismic zone and has suffered several damages including the earthquake-induced pounding damage during the 1988 earthquake....
-
Earthquake-induced pounding between equal height multi-storey buildings considering soil-structure interaction
PublicationThe present paper investigates the coupled effect of the supporting soil flexibility and pounding between neighbouring, insufficiently separated equal height buildings under earthquake excitation. Two adjacent three-storey structures, modelled as inelastic lumped mass systems with different structural characteristics, have been considered in the study. The models have been excited using a suit of ground motions with different peak...
-
Non-linear FEM analysis of pounding-involved response of buildings under non-uniform earthquake excitation
PublicationThe aim of the paper is to show the results of the study investigating the influence of non-uniform earthquake excitation, due to spatial seismic effects connected with the propagation of seismic wave, on the pounding-involved response of two buildings. The three-dimensional non-linear FEM analysis has been conducted using the detailed models of colliding structures. Acceleration records for different structural supports have been...
-
Letter to the Editor: Discussion on the Paper “State-of-the-Art of Research on Seismic Pounding Between Buildings with Aligned Slabs”
PublicationThe paper “State-of-the-art of research on seismic pounding between buildings with aligned slabs” (by Kharazian and López-Almansa) has recently been published in the journal of Archives of Computational Methods in Engineering. It can be considered as a kind of continuation of previous ‘state-of-the-art’ publications, including two papers and a book. Unfortunately, the paper contains a number of misleading or wrong statements as...
-
Mitigating the seismic pounding of multi-story buildings in series using linear and nonlinear fluid viscous dampers
PublicationSeismic-induced pounding between adjacent buildings may have serious consequences, ranging from minor damage up to total collapse. Therefore, researchers try to mitigate the pounding problem using different methods, such as coupling the adjacent buildings with stiff beams, connecting them by using viscoelastic links, and installing damping devices in each building individually. In the current paper, the effect of using linear and...
-
Non-Linear Analysis of Inter-Story Pounding between Wood-Framed Buildings during Ground Motion
PublicationPounding between adjacent buildings during ground motion may result in structural damage or lead to total destruction of structures. The research on the phenomenon has recently been much advanced; however, the analyses have been carried out only for concrete, steel, and masonry structures, while pounding between wooden buildings has not been studied so far. The aim of this paper is to show the results of detailed non-linear seismic...
-
Bounding approach to parameter estimation without priori knowledge on model structure error.
PublicationArtykuł przedstawia estymację parametrów modelu ARMA (Autoregresive moving average) metodą zbiorów ograniczonych. Założono brak wiedzy na temat ograniczeń na błąd struktury modelu lub, że wiedza ta jest bardzo konserwatywna. W celu redukcji tego konserwatyzmu, zaproponowano koncepcje modelu punktowo-parametrycznego. W podejściu tym zakłada się istnienie zbioru parametrów modelu oraz błędu struktury odpowiadających każdej z trajektorii...
-
Analytical expression between the impact damping ratio and the coefficient of restitution in the non-linear viscoelastic model of structural pounding
PublicationWyniki wcześniejszych badań pokazują, iż nieliniowy model lepko-sprężysty zderzeń konstrukcji budowlanych podczas trzęsień ziemi najdokładniej symuluje siłę zderzenia w czasie kontaktu oraz odpowiedź konstrukcji. Celem niniejszego artykułu jest wyprowadzenie wzoru na zależność pomiędzy liczbą tłumienia zderzenia (parametr wspomnianego modelu) a współczynnikiem odbicia, który jest parametrem często stosowanym i analizowanym w literaturze....
-
Influence of soil–structure interaction on seismic pounding between steel frame buildings considering the effect of infill panels
PublicationThe present research aims to study the influence of the soil-structure interaction (SSI) and existence or absence of masonry infill panels in steel frame structures on the earthquake-induced pounding-involved response of adjacent buildings. The study was further extended to compare the pounding-involved behavior versus the independent behavior of structures without collisions, focusing much on dynamic behavior of single frames....
-
Incremental Dynamic Analysis and Fragility Assessment of Buildings with Different Structural Arrangements Experiencing Earthquake-Induced Structural Pounding
PublicationStructural pounding is considered as one of the most critical phenomena occurring during earthquakes. This paper presents the incremental dynamic analysis and fragility assessment of buildings experiencing earthquake-induced pounding. Three 3-D buildings with different number of storeys and under different structural arrangements have been considered. Three pounding scenarios have been taken into account, i.e. pounding between...
-
Optimal retrofit strategy using viscous dampers between adjacent RC and SMRFs prone to earthquake‑induced pounding
PublicationNowadays, retrofitting-damaged buildings is an important challenge for engineers. Finding the optimal placement of Viscous Dampers (VDs) between adjacent structures prone to earthquake-induced pounding can help designers to implement VDs with optimizing the cost of construction and achieving higher performance levels for both structures. In this research, the optimal placement of linear and nonlinear VDs between the 3-story, 5-story,...
-
An ANN-Based Approach for Prediction of Sufficient Seismic Gap between Adjacent Buildings Prone to Earthquake-Induced Pounding
PublicationEarthquake-induced structural pounding may cause major damages to structures, and therefore it should be prevented. This study is focused on using an artificial neural network (ANN) method to determine the sufficient seismic gap in order to avoid collisions between two adjacent buildings during seismic excitations. Six lumped mass models of structures with a different number of stories (from one to six) have been considered in...
-
Evaluation of pounding effects between reinforced concrete frames subjected to far-field earthquakes in terms of damage index
PublicationIn this paper, three different damage indexes were used to detect nonlinear damages in two adjacent Reinforced Concrete (RC) structures considering pounding effects. 2-, 4- and 8-story benchmark RC Moment Resisting Frames (MRFs) were selected for this purpose with 60%, 75%, and 100% of minimum separation distance and also without any in-between separation gap. These structures were analyzed using the incremental dynamic analysis...
-
Effective Gap Size Index for Determination of Optimum Separation Distance Preventing Pounding between Buildings during Earthquakes
PublicationSeismic excitations may lead to collisions between adjacent civil engineering structures causing major damage. In this paper, an effective equation for calculating the gap size index is proposed so as to provide the optimum separation distance preventing structural pounding during different earthquakes. Evaluation of the best prediction of the required separation distance between two adjacent buildings was carried out by using...
-
Counting and tracking vehicles using acoustic vector sensors
PublicationA method is presented for counting vehicles and for determining their movement direction by means of acoustic vector sensor application. The assumptions of the method employing spatial distribution of sound intensity determined with the help of an integrated 3D intensity probe are discussed. The intensity probe developed by the authors was used for the experiments. The mode of operation of the algorithm is presented in conjunction...
-
A method for counting people attending large public events
PublicationThe algorithm for people counting in crowded scenes, based on the idea of virtual gate which uses optical flow method is presented. The concept and practical application of the developed algorithm under real conditions is depicted. The aim of the work is to estimate the number of people passing through entrances of a large sport hall. The most challenging problem was the unpredicted behavior of people while entering the building....
-
Chalcogen bonding interactions in a series of aromatic selenocyanates
PublicationSelenium atoms in aromatic selenocyanates are characterized by the occurrence of two σ-holes, a stronger one in the prolongation of the NC–Se bond and a weaker one in the prolongation of the Ar–Se bond. The crystal structures of several bis(selenocyanato) derivatives, prepared by a method originally developed for ortho bis-substituted derivatives, illustrate very well this difference, with a short NC–Se⋯NC ChB interaction organizing...
-
Inverse heat transfer problem solution of sounding rocket using moving window optimization
PublicationAn Inverse Heat Transfer Problem is solved for a sounding rocket module given its geometry and measured temperature profile. The solution is obtained via moving window optimization, a technique for solving inverse dynamics. An analysis is performed to modify the method to avoid oscillatory behavior of the resulting heat flux profile. The method parameters are tuned in relation to characteristic phases of the flight. Results are...
-
Non-linear FEM analysis of earthquake-induced pounding between the main building and the stairway tower of the Olive View Hospital
PublicationCelem artykułu jest dokładna, trójwymiarowa analiza MES dotycząca zderzeń pomiędzy budynkiem głównym a konstrukcją wolnostojącej klatki schodowej szpitala Olive View podczas trzęsienia ziemi San Fernando w roku 1971. Wyniki analizy pokazują, iż kolizje mogą prowadzić do znacznego wzrostu odpowiedzi lżejszej konstrukcji klatki schodowej, powodować uszkodzenia w miejscach kontaktu oraz potęgować uszkodzenia u podstawy tej budowli....
-
Probabilistic seismic assessment of RC box-girder highway bridges with unequal-height piers subjected to earthquake-induced pounding
PublicationThis paper uses the probabilistic seismic assessment to study the effects of pounding and irregularity on the seismic behavior of typical concrete box-girder bridges with four levels of altitudinal irregularity. To extend the results for all bridges in the same class, uncertainty related to the earthquake, structural geometries, and materials are considered. Pounding is likely to take place in two cases: the first one concerns...