Filters
total: 994
filtered: 743
-
Catalog
Chosen catalog filters
Search results for: PEDOT-RGO
-
Study of the NO2 sensing mechanism of PEDOT-RGO film using in situ Raman Spectroscopy
PublicationIn this work, the mechanism of the NO2 reaction with PEDOT-RGO composite film has been investigated via in situ Raman spectroscopy. Reduced graphene oxide (RGO), poly(3,4-ethylenedioxytiophene)-reduced graphene oxide (PEDOT-RGO) and poly(3,4-ethylenedioxytiophene)/ClO4− (PEDOT/ClO4−) films were fabricated using an electrodeposition method and used as resistance sensors of gaseous nitrogen dioxide. The experimental results indicate...
-
Deposition of EDOT-Decorated Hollow Nanocapsules into PEDOT Films for Optical and Electrochemical Sensing
Publication -
PEDOT(PSS) as Solid Contact for Ion-Selective Electrodes: The Influence of the PEDOT(PSS) Film Thickness on the Equilibration Times
Publication -
The effect of PEDOT morphology on hexavalent chromium reduction over 2D TiO2/PEDOT photocatalyst under UV–vis light
PublicationThe present study represents an approach to apply organic-inorganic hybrid materials for photocatalytic removal of heavy metals from the aqueous environment. The photocatalytic activity of the semiconductor modified with the conjugated polymer may depends on the conjugated polymer type, its amount and morphology. Therefore, in the present study the effect of poly (3, 4-ethylenedioxythiophene) (PEDOT) morphology on adsorption and photoreduction...
-
Nitrogen dioxide sensing properties of PEDOT polymer films
PublicationThis work presents a simple and fully electrochemical route for the polymerization of poly(3,4-ethylenedioxytiophene) (PEDOT) films for fabricating a NO2 gas sensor prepared by electropolymerization of 3,4-Ethylenedioxythiophene (EDOT) monomer in lithium perchlorate/acetonitrile solution. The main aim of this study is to determine the sensing properties of conductive polymer at elevated temperatures. The effects of the humidity,...
-
Graphene oxide, reduced graphene oxide and composite thin films NO2 sensing properties
PublicationA graphene oxide (GO), reduced graphene oxide (RGO) and poly(3,4-ethylenedioxytiophene)-reduced graphene oxide (PEDOT-RGO composite) gas sensors were successfully fabricated using an electrodeposition method. The electrodeposition was carried out in aqueous GO dispersions. To obtain RGO and PEDOT-RGO, the electrochemical reduction of GO and PEDOT-GO was carried out in 0.1 M KCl at a constant potential of −0.85 V. The GO, RGO and PEDOT-RGO...
-
Graphene oxide, reduced graphene oxide and composite thin films NO2 sensing properties
PublicationA graphene oxide (GO), reduced graphene oxide (RGO) and poly(3,4-ethylenedioxytiophene)- reduced graphene oxide (PEDOT-RGO composite) gas sensors were successfully fabricated using an electrodeposition method. The electrodeposition was carried out in aqueous GO dispersions. In order to obtain RGO and PEDOT-RGO, the electrochemical reduction of GO and PEDOT-GO was carried out in 0.1 M KCl at constant potential of −0.85 V. The GO, RGO...
-
Influence of electropolymerization conditions on the morphological and electrical properties of PEDOT film
PublicationIn this work the effects of electropolymerization conditions on the morphological properties and conductivity of poly(3,4-ethylenedioxythiophene) (PEDOT) film have been studied. PEDOT films were electrochemically synthesized in a one step process from acetonitrile solution containing 3,4-ethylenedioxythiophene (EDOT) and lithium perchlorate. Based on atomic force microscopy, scanning electron microscopy, cyclic voltammetry and...
-
Chemorezystancyjny czujnik gazu na bazie polimeru przewodzącego PEDOT
PublicationPolimery przewodzące, takie jak Poli(3,4-etylenodioksytiofen) (PEDOT) są atrakcyjnymi materiałami elektrodowymi, które posiadają takie zalety, jak biokompatybilność, duża przewodność i elastyczność. Elektroprzewodzące polimery można otrzymać w wyniku chemicznej polimeryzacji lub elektropolimeryzacji. W niniejszej pracy przedstawiono zostanie koncepcja czujnika gazów składająca się z elektrody grzebieniowej oraz polimeru przewodzącego...
-
New light on the photocatalytic performance of NH4V4O10 and its composite with rGO
PublicationSolar-driven photocatalysis has shown great potential as a sustainable wastewater treatment technology that utilizes clean solar energy for pollutant degradation. Consequently, much attention is being paid to the development of new, efficient and low-cost photocatalyst materials. In this study, we report the photocatalytic activity of NH4V4O10 (NVO) and its composite with rGO (NVO/rGO). Samples were synthesized via a facile one-pot...
-
Laser patterned platform with PEDOT–graphene composite film for NO2 sensing
PublicationThis work presents a simple and fully electrochemical route used for fabricating of a NO2 gas sensor made of reduced-graphene-oxide-poly(3,4-ethylenedioxythiophene) composite film. The sensing platform was fabricated from alumina substrate and equipped with gold interdigitated electrodes and built-in heater.The temperature distribution on the surface of interdigitated electrodes was investigated by a thermalimaging camera and compared...
-
The optimal construction of fiber-optic Fabry-Perot interferometer
PublicationTematem artykułu jest optymalizacja sensorów światłowodowych, wykorzystujących interferometer Fabry-Perota, pracujących w modzie odbiciowym. Celem optymalizacji była maksymalizacja rozdzielczości i dokładności sensora. Autorzy przedstawili analizę teoretyczną oraz wyniki eksperymentalnej optymalizacji światłowodowego interferometru Fabry-Perota, zaprojektowanego i zrealizowanego w laboratorium KOiSE PG.
-
Electroactive polymer/graphene oxide nanostructured composites; evidence for direct chemical interactions between PEDOT and GOx
PublicationThis work concerns electrochemical synthesis of nanocomposites consisting of conducting polymer and reduced graphene oxide (rGOx) as electrode materials for supercapacitors. The electrosynthesis was performed in an aqueous solution of the 3,4-ethylenedioxytiophene (EDOT) monomer and graphene oxide (GOx) without supporting electrolyte. The amount of GOx was optimized to obtain the best electrochemical performance of the nanocomposite...
-
Modeling of multi-cavity Fabry-Perot optical fiber sensors
PublicationReflectance characteristics of a two-cavity extrinsic Fabry-Perot optical fiber sensor were investigated using computer modeling. Calculations were performed using a plane wave-based approach, selected for clarity of results. Based on the modeling results, it can be concluded that the two-cavity Fabry-Perot interferometer can be used to measure two different quantities, such as refractive index and temperature, independently. It...
-
Electrodes consisting of PEDOT modified by Prussian Blue analogues deposited onto titania nanotubes – Their highly improved capacitance
PublicationIn this work we present the outstanding energy storage of prepared inorganic-organic heterojunction where hydrogenated ordered titania nanotubes (H-TiO2NT) were modified by the hybrid made of poly(3,4-ethylenedioxythiophene) (pEDOT) and iron hexacyanoferrate centres (Fehcf, Prussian Blue). The material TiO2NT/pEDOT:Fechf was obtained electrochemically by means of: anodization, hydrogenation and finally, electropolymerization of...
-
The Influence of PEDOT to PSS Ratio on the Optical Properties of PEDOT:PSS Thin Solid Films - Insight from Spectroscopic Ellipsometry
Publication -
Differences in Electrochemically Deposited PEDOT(PSS) Films on Au and Pt Substrate Electrodes: A Quartz Crystal Microbalance Study
Publication -
Electrochemical characterization of a composite comprising PEDOT/PSS and N doped TiO2 performed in aqueous and non-aqueous electrolytes
PublicationNitrogen doped titania (N-TiO2) was used as an inorganic component of composite electrodes containing poly(3,4-ethylenedioxythiophene) with poly(4-styrenesulphonate) PEDOT/PSS/N-TiO2. The composite materials were obtained by direct electrodeposition from an N-TiO2 suspension containing polyelectrolyte (NaPSS) and monomer EDOT. The electrodes were electrochemically tested in aqueous and non-aqueous electrolytes using cyclic voltammetry...
-
Solid-Contact pH Sensor without CO2Interference with a Superhydrophobic PEDOT-C14as Solid Contact: The Ultimate “Water Layer” Test
Publication -
Electrical Interface Parameters of PEDOT: PSS: Effect of Electrodeposition Charge Evaluated Under Body Conditions for Neural Electrode Applications
PublicationThis study explores the influence of the deposition charge of poly(3,4-ethylenedioxythiophene) doped with polystyrene sulfonate (PEDOT:PSS) on its electrical interface parameters. For this purpose, PEDOT:PSS was fabricated by electrodeposition on commercial platinum electrodes with the time limited by different charges (1, 3, 6, 9 mC). Further, the electrodes were characterized regarding their electrical interface such as interfacial...
-
A simple route of providing a soft interface for PEDOT: PSS film metallic electrodes without loss of their electrical interface parameters
PublicationThe work presents the development of a soft interface at PEDOT:PSS film without changing its electrical interface parameters. In the first step, PEDOT:PSS is electrodeposited on the commercial platinum electrode under the state-of-the-art conditions desirable for different electrochemical electrodes. Secondly, a pure hydrogel layer is deposited on the top of the electrodeposited PEDOT:PSS film under conditions that provide desirable...
-
Gas sensors based on conducting polymers-recent developments
PublicationThis work discusses sensing performance dependence of PEDOT polymer and its composites on the counter ions used in the polymerization process. The sensors based on PEDOT-RGO composite show reversible response to NO2, while on PEDOT/LiClO4 irreversible. As a result, PEDOT-RGO could be used as a typical gas sensor, while sensor based PEDOT/LiClO4 could be used as an integrating gas sensor, also known as an accumulating gas sensor....
-
The influance of infiltration of LNF cathode with CGO
Publication -
High Q-factor Microwave Fabry-Perot Resonator With Distributed Bragg Reflectors
PublicationZrealizowany został rezonator Fabry-Perot pracujący na częstotliwości 39 GHz i wykorzystujący dwie pary ćwierćfalowych kwarcowych reflektorów Bragga. Dla fali o długości 98.26 mm otrzymano dobroć ok. 560,000, co oznacza 4.3-krotny wzrost w porównaniu z identycznym rezonatorem bez reflektorów Bragga. Analizę problemu wykonano przy pomocy metody różnic skończonych w dziedzinie częstotliwości (FDFD) i porównano z uproszczonym rozwiązaniem...
-
Microwave Characterization of Dielectric Sheets in a Plano-Concave Fabry-Perot Open Resonator
PublicationDespite its long history, a double-concave (DC) Fabry-Perot open resonator (FPOR) has recently gained popularity in the characterization of dielectrics in the 20–110 GHz range, mainly due to such novel accomplishments as full automation of the measurement process and the development of even ore accurate and computationally efficient electromagnetic model. However, it has been discovered that such a DC resonator suffers from unwanted...
-
Efficient Fabry-Perot Open Resonator Analysis by the use of a Scattering Matrix Method
PublicationIn this paper a comparative study of the computational efficiency of two modeling methods applied to the analysis of the plano- and double-concave Fabry-Perot open resonators is presented. In both numerical approaches, a scattering matrix method was applied, which allows splitting the analysis of the resonator into several sections, including the one with a spherical mirror, which requires the largest computing resources. Two modeling...
-
The in situ construction of three-dimensional core–shell-structured TiO2@PPy/rGO nanocomposites for improved supercapacitor electrode performance
Publication -
Flexible Films as Anode Materials Based on rGO and TiO2/MnO2 in Li-Ion Batteries Free of Non-Active Agents
Publication -
Study on the effect of the metal–support (Fe-MgO and Pt-MgO) interaction in alcohol-CVD synthesis of carbon nanotubes
Publication -
Titania nanotubes infiltrated with conducting polymer PEDOT modified by Prussian Blue – a novel type of organic-inorganic heterojunction characterised with enhanced photoactivity.
PublicationA highly ordered p–n heterojunction was formed based on titania nanotubes containing a conducting polymer with Prussian blue matrix. The study demonstrates, for the first time, cases when a composite based on titania array scaffolding and Prussian blue embedded in PEDOT exhibits reversible FeII/FeIII redox activity. Highly enhanced photoactivity and capacitance of the obtained material are depicted in comparison to pristine titania....
-
Fabrication and photoactivity of organic-inorganic systems based on titania nanotubes and PEDOT containing redox centres formed by different Prussian Blue analogues
PublicationHerein, the heterojunction composed of an inorganic substrate: ordered hydrogenated titania nanotubes (H-TiO2NTs) and a deposited organic film: poly(3,4-ethylenedioxythiophene) (PEDOT) is reported. The conducting polymer is modified with different transition metal haxacyanoferrates (Mehcf), wherein as metal: copper, iron, cobalt and nickel are introduced. The presence of various metal centres provides characteristic redox activity...
-
Optimization of a Fabry-Perot Sensing Interferometer design for an optical fiber sensor of hematocrit level
PublicationContinuous measurement of the hemato crit level in blo o d can p otentially b e p erformed using optical bre sensors. The FabryPerot interferometric sensors are a promising candidate in this application. The most imp ortant step in the design of the sensor is design of the sensing interferometer. Adequate cavity length and high interference contrast are two most imp ortant requirements in this application. The design metho d of...
-
Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
Publication -
ALD thin ZnO layer as an active medium in a fiber-optic Fabry–Perot interferometer
Publication -
Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
PublicationIn this paper, a low-coherence Fabry-Perot sensor with a spectrally measured signal processing response to the refractive index of liquids is presented. Optical fiber sensors are potentially capable of continuous measuring hematocrit levels in blood. Low-coherence Fabry-Perot interferometric sensors offer a robust solution, where information about the measurand is encoded in the full spectrum of light reflected from the sensing...
-
ALD thin ZnO layer as an active medium in a fiber-optic Fabry-Perot interferometer
Publication.
-
Aby ro-ro było bezpieczne
PublicationW artykule przedstawiono skrótowo najważniejsze zasady podziału wodoszczelnego statków ro-ro pod kątem bezpieczeństwa w stanie awaryjnym.
-
On Facial Expressions and Emotions RGB-D Database
PublicationThe goal of this paper is to present the idea of creating reference database of RGB-D video recordings for recognition of facial expressions and emotions. Two different formats of the recordings used for creation of two versions of the database are described and compared using different criteria. Examples of first applications using databases are also presented to evaluate their usefulness.
-
Crack propoagation in MgO-PSZ ceramic materials
PublicationThe properties of ceramic materials such as elevated hardness, high temperature capability, low coefficient of thermal expansion are of interest for rolling element materials. Widely used ceramic materials in engineering applications are silicon nitride, zirconia and alumina. The paper presents an experimental study of the fatigue life of MgO-PSZ ceramic material in lubricated contact with defined types of cracks. A ceramic angular...
-
Correction: Titania nanotubes infiltrated with the conducting polymer PEDOT modified by Prussian blue – a novel type of organic–inorganic heterojunction characterised with enhanced photoactivity
Publication -
Effects of decks on survivability of ro-ro vessels
PublicationPrzedstawiono wpływ pokładów na prawdopodobieństwo przetrwania zatopienia danego przedziału w świetle metody statycznej równoważności.
-
Intrinsic energy resolution and light yield nonproportionality of BGO
Publication -
Application of the Fractional Fourier Transform for dispersion compensation in signals from a fiber-based Fabry-Perot interferometer
PublicationOptical methods of measurement do not require contact of a probe and the object under study, and thus have found use in a broad range of applications such as nondestructive testing (NDT), where noninvasive measurement is crucial. Measuring the refractive index of a material can give a valuable insight into its composition. Low‑coherence radiation sources enable measurement of the sample’s properties across a wide spectrum, while...
-
The influence of polarization of titania nanotubes modified by a hybrid system made of a conducting polymer PEDOT and Prussian Blue redox network on the Raman spectroscopy response and photoelectrochemical properties
PublicationIn this work we show the impact of applied potential on network vibrations and photoelectrochemical properties of a composite material containing hydrogenated titania nanotubes and poly (3,4-ethylenedioxythiophene) with iron hexacyanoferrate (H-TiO2/pEDOT:Fehcf) acting as a redox centre. For this purpose, Raman spectroscopy measurements under the working electrode (WE) polarization were carried out, allowing investigation of changes...
-
A hybrid model of flooding of the ro-ro ships in damaged conditions
PublicationThe paper presents some results on investigations concerning development of a hybrid model for assessment of performance of the ro‐ro ships in damaged conditions. The model is devoted towards assessing the performance of the damaged ro‐ro ships at the preliminary stage of design. The key problems associated with preparing of such the model are associated with working out a method of assessment of the damaged roro ships performance,...
-
Survival criteria for passenger ro-ro vessels and survival time
PublicationArtykuł podaje związek między kryteriami stateczności (mnożnikiem s) a czasem przetrwania dla statków ro-ro. Mnożnik s, zalecany przez IMO, nie ma żadnego związku z czasem przetrwania ani ze stanem morza.
-
MgO/CaO-loaded porous carbons for carbon dioxide capture
Publication -
CGO FILMS ON YSZ ELECTROLYTE FABRICATED BY SPRAY PYROLYSIS FOR SOFC
PublicationINTRODUCTION Solid oxide fuel cells are one of the fastest developing energy converters. The advancement introduced by research community provides steady state progress is stability and performance of the fuel cells. Significant influence on the cell’s performance and stability is related to cell design. The simplest design just consists of an anode, a solid electrolyte and a cathode. However, in order to improve the properties,...
-
Computer-aided analysis of signals from a low-coherence Fabry-Perot interferometer used for measurements of biological samples
PublicationThe aim of the study was to develop an automated computer-aided system for analysis of spectrograms obtained from measurements of biological samples performed with a low-coherence Fabry-Pérot interferometer. Information necessary to determine dispersion characteristics of measured materials can be calculated from the positions of the maxima and minima that are present in their spectra. The main challenge faced during the development...
-
Determination of refractive index dispersion using fiber-optic low-coherence Fabry–Perot interferometer: implementation and validation
PublicationWe present the implementation and validation of low-coherence Fabry–Perot interferometer for refractive index dispersion measurements of liquids. A measurement system has been created with the use of four superluminescent diodes with different optical parameters, a fiber-optic coupler and an optical spectrum analyzer. The Fabry–Perot interferometer cavity has been formed by the fiber-optic end and mirror surfaces mounted on a micromechanical...