Filters
total: 1095
-
Catalog
displaying 1000 best results Help
Search results for: IMPEDANCJA ELEKTRODOWA
-
Electrochemical impedance spectroscopy measurements - conductivity vs. temperature and conductivity vs. oxygen partial pressure - BaCe0.6Zr0.2Y0.1Tb0.1O3-δ
Open Research DataThe dataset consists of two main catalogs consisting of measurement data: of the electrical conductivity of the BaCe0.6Zr0.2Y0.1Tb0.1O3-δ (BCZYTb) sample as a function of temperature and of the electrical conductivity as a function of oxygen partial pressure (pO2). Measurements as a function of temperature were carried out in dry and wet air (pH2O ~...
-
Evaluation of organic coatings condition with AFM-based method
PublicationThe paper presents an atomic force microscopy (AFM)-based approach to evaluation of local protective properties of organic coatings. Apart from topography, it provides local ac and dc characteristics of examined coating. The method consists in application of ac voltage perturbation signal between conductive AFM tip and coated metal substrate. The resulting current is used to determine local impedance characteristics. Both impedance...
-
Diagnozowanie systemów ochrony katodowej techniką spektroskopii impedancyjnej
PublicationZaprezentowano wyniki badań wykonywanych techniką elektrochemicznej spektroskopii impedancyjnej (EIS) na elementach instalacji ochrony katodowej podziemnego rurociągu stalowego. Przedstawiono widma impedancyjne układów rurociąg-elektrody odniesienia (stacjonarne i przenośne). Wykazano, że przy pomocy EIS można zbadać stan techniczny elektrod odniesienia, co pozwala określić wiarygodność wyników pomiarów potencjału chronionej konstrukcji....
-
Application of harmonic techniques to evaluation of pitting corrosion
PublicationPrzedstawiono próbę zastosowania metod zmiennoprądowych do oceny podatności na korozję wżerową stali stopowych. Na sygnał stałoprądowy nałożono sinusoidę o częstotliwości 10 Hz. Dzięki jednoczesnej, cyfrowej rejestracji sygnału pobudzenia i odpowiedzi układu badanego otrzymano ciągłe zmiany modułu impedancji i modułu pojemności w trakcie klasycznej cyklicznej polaryzacji. Na podstawie jednego eksperymentu istnieje możliwość wyznaczenia...
-
Analizator do spektroskopii wysokoimpedancyjnej powłok antykorozyjnych
PublicationW pracy przedstawiono analizator do spektroskopii wysokoimpedancyjnej, w którym zastosowano sondę wejściową umożliwiającą pomiary impedancji do |Zx|<100Gohm w szerokim zakresie częstotliwości od 10uHz-1MHz. Opracowano metodę pomiaru impedancji opartą na próbkowaniu sygnałów oraz wyznaczaniu ich parametrów za pomocą algorytmów cyfrowego przetwarzania sygnałów. W pracy omówiono rozwiązania układowe i programistyczne, zastosowane...
-
Influence of vacuum sublimation deposited metal layer thickness on metrological parameters of the amperometric gas sensor with Nafion membrane
PublicationThe paper presents the results of investigation on an influence of vacuum sublimation deposited platinum layer thickness on the signal, sensitivity and response time of a prototype of sulphur dioxide sensor with Nafion membrane. The working electrode was made by vacuum sublimation deposition of platinum on a surface of Nafion membrane. Pt layers deposited changed an initial structure of Nafion membrane and that phenomenon was utilized...
-
Badanie przewodnictwa jonowego materiału katodowego do ogniw SOFC na bazie La1-xSrxMnO3-δ
PublicationMieszane przewodniki jonowo-elektronowe na bazie domieszkowanego manganianu lantanu znajdują powszechne zastosowanie m.in. jako elektrody w ogniwach paliwowych, czujnikach gazów lub jako warystory. Jednak wciąż niepoznane do końca mechanizmy występowania zjawiska mieszanego przewodnictwa sprawiają, że prace nad tymi materiałami wciąż trwają. Określenie składowej jonowej tego typu materiałów perowskitowych wymaga zastosowania...
-
Ryszard Katulski prof. dr hab. inż.
People -
Szybkie metody spektroskopii impedancyjnej
PublicationW pracy przedstawiono metody i układy przyspieszające pomiary widma impedancji i identyfikację elementów układów zastępczych obiektów technicznych. Zostały one ukierunkowane na implementację w tanich przyrządach diagnostycznych nadających się do pracy w różnych warunkach, m. in. w terenie. Aby skrócić czas pomiaru impedancji zastosowano różne sygnały pobudzenia: harmoniczne, wieloharmoniczne, impuls prostokątny. Do identyfikacji...
-
The voltage across and current through the RC model object tested using pulse excitation in impedance spectroscopy measurement method
Open Research DataThe raw data (voltage across and current through RC model object ) obtained using pulse excitation EIS impedance spectroscopy measurement method. The data was acquired using 12-bit ADC (LTC1420) with sampling frequency changed in time segments. The 1V voltage pulse excitation duration was set to 0.1s and the total acqusition time was set to 1000s. For...
-
Influence of sintering temperature of porous SrTi0.30Fe0.70O3-d oxygen electrode on electrochemical impedance spectroscopy spectra measured at 800 °C
Open Research DataThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at different temperatures (800 °C; 900 °C and 1000 °C). Measure temperature was 800 °C (syntetic air, 40 ml min-1). Results converted to electrode surfaces area and dived by two electrodes.
-
Electrochemical impedance spectroscopy spectra measured at 700 °C on porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at different temperatures
Open Research DataThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at different temperaturs (800 °C, 900 °C and 1000 °C). EIS spectra were measured at 700 °C with synthetic air flow (21% O2, 40 ml min-1). Results converted to electrode surfaces area and dived by two...
-
Influence of sintering temperature of porous SrTi0.50Fe0.50O3-d oxygen electrode on electrochemical impedance spectroscopy spectra measured at 800 °C
Open Research DataThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.50Fe0.50O3-d oxygen electrodes sintered at different temperatures (800 °C; 900 °C and 1000 °C). Measure temperature was 800 °C (syntetic air, 40 ml min-1). Results converted to electrode surfaces area and dived by two electrodes.
-
Electrochemical impedance spectroscopy spectra measured at 700 °C on porous SrTi0.65Fe0.35O3-d oxygen electrodes sintered at different temperatures
Open Research DataThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.65Fe0.35O3-d oxygen electrodes sintered at different temperaturs (800 °C, 900 °C and 1000 °C). EIS spectra were measured at 700 °C with synthetic air flow (21% O2, 40 ml min-1). Results converted to electrode surfaces area and dived by two...
-
Influence of sintering temperature of porous SrTi0.65Fe0.35O3-d oxygen electrode on electrochemical impedance spectroscopy spectra measured at 800 °C
Open Research DataThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.65Fe0.35O3-d oxygen electrodes sintered at different temperatures (800 °C; 900 °C and 1000 °C). Measure temperature was 800 °C (syntetic air, 40 ml min-1). Results converted to electrode surfaces area and dived by two electrodes.
-
Electrochemical impedance spectroscopy spectra measured at 700 °C on porous SrTi0.50Fe0.50O3-d oxygen electrodes sintered at different temperatures
Open Research DataThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.50Fe0.50O3-d oxygen electrodes sintered at different temperaturs (800 °C, 900 °C and 1000 °C). EIS spectra were measured at 700 °C with synthetic air flow (21% O2, 40 ml min-1). Results converted to electrode surfaces area and dived by two...
-
Ryszard Strzelecki prof. dr hab. inż.
People -
The use of numerical methods for the analysis of phase phenomena in multi element antennas.
PublicationW artykule zostały zaprezentowane wyniki analizy wpływu wzajemnej i własnej impedancji promieniowania na fazę sygnału odbieranego przez antenę wieloelementową. Obliczenia dokonano dla elektrycznego modelu zastępczego Mason`a przetwornika ultradźwiękowego.
-
Adaptive estimation of the transformer stray capacitances for DC–DC converter modelling
PublicationNew low cost and accurate estimation method of transformer stray capacitances for wide band DC–DC converter modelling and design is proposed. The Wiener filter (WF) method is applied to estimate the transformer impedance – referred to the selected transformer winding configurations. Laboratory tests are used to adapt the filter, that is to find optimal impedance which minimises mean square error between measured, noise perturbed...
-
Distribution of Relaxation Times analysis results of impedance measured in function of temperature on porous SrTi0.50Fe0.50O3-d oxygen electrode sintered at 800 °C
Open Research DataThis dataset contains results of Distribution of Relaxation Times analysis (DRT) of impedance of symmetrical cells with porous SrTi0.50Fe0.50O3-d oxygen electrodes sintered at 800 °C. Electrochemical impedance spectroscopy were measured at 800 °C; 750 °C and 700 °C (syntetic air). The DRTTools Matlab GUI, available from prof. Ciucci’s group, was used...
-
Distribution of Relaxation Times analysis results of impedance measured in function of temperature on porous SrTi0.30Fe0.70O3-d oxygen electrode sintered at 800 °C
Open Research DataThis dataset contains results of Distribution of Relaxation Times analysis (DRT) of impedance of symmetrical cells with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C. Electrochemical impedance spectroscopy were measured at 800 °C; 750 °C and 700 °C (syntetic air). The DRTTools Matlab GUI, available from prof. Ciucci’s group, was used...
-
Distribution of Relaxation Times analysis results of impedance measured in function of temperature on porous SrTi0.65Fe0.35O3-d oxygen electrode sintered at 800 °C
Open Research DataThis dataset contains results of Distribution of Relaxation Times analysis (DRT) of impedance of symmetrical cells with porous SrTi0.65Fe0.35O3-d oxygen electrodes sintered at 800 °C. Electrochemical impedance spectroscopy were measured at 800 °C; 750 °C and 700 °C (syntetic air). The DRTTools Matlab GUI, available from prof. Ciucci’s group, was used...
-
Elektrochemiczny gazowy czujnik na bazie cieczy jonowej do oznaczania benzaldehydu
PublicationW pracy przedstawiono wyniki badań dotyczące opracowania dwóch wersji prototypowego, laboratoryjnego elektrochemicznego czujnika do oznaczania par benzaldehydu. Elektrolitem w tych czujnikach była ciecz jonowa [HMIM][Tf2N] (bis(trifluorometylosulfonylo)imidek 1-heksylo,3-metyloimidazolinowy). Jeden z czujników zbudowany był wg koncepcji Clarka z membraną PDMS, drugi z użyciem komercyjnych elektrod firmy DropSens Co. W obu wersjach,...
-
Zastosowanie lasera femto - sekundowego do modyfikacji fotoelektrody TiO2 w barwnikowym ogniwie fotowoltaicznym,
PublicationW pracy przedstawiono wyniki badań dla barwnikowych ogniw fotowoltaicznych, w których złącze półprzezroczysta elektroda przewodząca (TCO)/porowata warstwa ditlenku tytanu zostało zmodyfikowane przy użyciu wiązki lasera femtosekundowego. Przeprowadzone badania charakterystyki prądowo-napięciowej oraz elektrochemicznej spektroskopii impedancyjnej pozwoliły na opisanie wpływu modyfikacji granicy faz na parametry elektryczne urządzeń....
-
Distribution of Relaxation Times analysis results of impedance measured at 700 °C on porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at different temperatures
Open Research DataThis dataset contains results of Distribution of Relaxation Times analysis (DRT) of impedance of symmetrical cells with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at different temperatures (800 °C, 900 °C and 1000 °C). Electrochemical impedance spectroscopy were measured at 700 °C (syntetic air). The DRTTools Matlab GUI, available from prof....
-
Distribution of Relaxation Times analysis results of impedance measured at 700 °C on porous SrTi0.50Fe0.50O3-d oxygen electrodes sintered at different temperatures
Open Research DataThis dataset contains results of Distribution of Relaxation Times analysis (DRT) of impedance of symmetrical cells with porous SrTi0.50Fe0.50O3-d oxygen electrodes sintered at different temperatures (800 °C, 900 °C and 1000 °C). Electrochemical impedance spectroscopy were measured at 700 °C (syntetic air). The DRTTools Matlab GUI, available from prof....
-
Distribution of Relaxation Times analysis results of impedance measured at 700 °C on porous SrTi0.65Fe0.35O3-d oxygen electrodes sintered at different temperatures
Open Research DataThis dataset contains results of Distribution of Relaxation Times analysis (DRT) of impedance of symmetrical cells with porous SrTi0.65Fe0.35O3-d oxygen electrodes sintered at different temperatures (800 °C, 900 °C and 1000 °C). Electrochemical impedance spectroscopy were measured at 700 °C (syntetic air). The DRTTools Matlab GUI, available from prof....
-
Production of gaseous matrix-free reference materials. Application of thermoanalytical techniques
PublicationMateriały odniesienia są wykorzystywane w każdym laboratorium w celu zapewnienia jakości wyników pomiarów analitycznych. Produkcja materiałów odniesienia nie jest zadaniem łatwym, szczególnie w przypadku składników gazowych, toksycznych i o nieprzyjemnym zapachu. Termiczny rozkład związków powierzchniowych jest bardzo dogodnym sposobem sporządzania właśnie tego rodzaju mieszanin. Ważną rolę w procesie termicznego rozkładu związków...
-
System do spektroskopii impedancyjnej z wykorzystaniem oscyloskopu cyfrowego.
PublicationW artykule przedstawiono alternatywną dla fabrycznych mierników impedancji metodę badań spektroskopowych materiałów biologicznych. System pomiarowy pozwala na osiągnięcie dużej dokładności pomiarów w szerokim zakresie częstotliwości, zwłaszcza w zakresie niskich częstotliwości.
-
Odporność korozyjna staliwa wysokochromowego
PublicationBadano odporność korozyjną staliwa wysokochromowego w dwóch stanach: lanym i po obróbce cieplnej - hartowaniu i odpuszczaniu. Stwierdzono korzystny wpływ obróbki cieplnej na odporność korozyjną, ocenianą metodą badania polaryzacji i impedancji.
-
Fitted impedance spectra of a symmetrical porous Sr0.86Ti0.65Fe0.35O3 oxygen electrode (sintered at 1000 °C, measured at 700 °C and 0.1% pO2) with an individual contributions of the respective fitting elements
Open Research DataThis dataset contains exemplary impedance spectra (measured at 700 °C and 0.1% pO2) for porous Sr0.86Ti0.65Fe0.35O3 oxygen electrode sintered at 1000 °C. Results of symmetric cell impedance measurement were converted to electrode surfaces area and dived by two electrodes. Dataset conatins also fitting results and individual contributions of the respective...
-
Fitted impedance spectra of a symmetrical porous Sr0.86Ti0.65Fe0.35O3 oxygen electrode (sintered at 1000 °C, measured at 800 °C and 0.1% pO2) with an individual contributions of the respective fitting elements
Open Research DataThis dataset contains exemplary impedance spectra (measured at 800 °C and 0.1% pO2) for porous Sr0.86Ti0.65Fe0.35O3 oxygen electrode sintered at 1000 °C. Results of symmetric cell impedance measurement were converted to electrode surfaces area and dived by two electrodes. Dataset conatins also fitting results and individual contributions of the respective...
-
Optimal configuration of an electrode array for measuring ventricles' contraction
PublicationAn influence of an electrode-array configuration on an impedance signal composition for a fixed spatial distribution of its sources is examined in the paper. The Finite Element Method and Geselowitz relationship were used for examining three different electrode-arrays. A sensitivity approach was used to evaluate each configuration assuming that localization of the signal source is known. A conductivity change, thus the source of...
-
RECENT ADVANCES IN GRAPHENE APPLICATION FOR ELECTRONIC SENSING
PublicationThe great interest in graphene is caused by its potential for constructing various sensors exhibiting excellent parameters. The high carrier mobility and the unique band structure of graphene makes it promising especially in the field-effect transistors (GFET) applications. In this article, recent advances of the selected graphene-based sensor applications were presented and the possible directions for further investigations were...
-
Nowa metoda optymalizacji pracy ogniw paliwowych.
PublicationPrzedstawiono dynamiczną technikę impedancją jako doskonałe narzędzie służące do określenia optymalnych warunków pracy ogniw paliwowych. Możliwości tej techniki zostały przedstawione na przykładzie ustalenia optymalnej temperatury pracy. Otrzymane wyniki zostały skonfrontowane z charakterystykami prądowo napięciowymi ogniwa.
-
Hybrid biobattery based on arylated carbon nanotubes and laccase
PublicationJednościenne nanorurki węglowe modyfikowano resztami antracenu i antrachinonu Otrzymany materiał posłużył do modyfikacji elektrody węglowej w celu jej zastosowania do redukcji tlenu w bioogniwie paliwowym. Nanorurki z aromatycznymi grupami zwiększyły powierzchnię elektrody oraz przyczyniły się do zwiększenia bezpośredniego przeniesienia elektronów. Grupy arylowe mogą wnikać do hydrofobowej kieszeni enzymu, w której znajduje się...
-
A comprehensive evaluation of mimosa extract as a corrosion inhibitor on AA6060 alloy in acid rain solution: part I. Electrochemical AC methods
PublicationThe inhibition effect of mimosa extract on the corrosion of AA6060 aluminum alloy in acid rain solution was investigated by electrochemical impedance spectroscopy and dynamic electrochemical impedance spectroscopy (DEIS). All the studied electrochemical parameters showed good corrosion inhibitive characteristics with respect to the aluminum alloy in the tested solution. Inhibitor efficiency increased with the concentration and...
-
Wyznaczanie właściwości uziemień metodami statycznymi, wysokoczęstotliwościowymi i udarowymi
PublicationW artykule przedstawiono różne metody pomiaru rezystancji statycznej i udarowej oraz impedancji uziemień. Przedstawiono wyniki badań porównawczych wykonanych przy użyciu metody statycznej, wysokoczęstotliwościowej oraz udarowej. Omówiono obszary zastosowań oraz ograniczenia omawianych metod.
-
Mechanizm korozji stopu Al-Si nadtapianego laserowo w niskiej temperaturze.
PublicationBadano odporność na korozję elektrochemiczną stopu Al-Si metodami krzywych polaryzacji i impedancji. Ujawniono wyraźny wzrost odporności na korozję stopu nadtapianego laserowo po schłodzeniu do niskiej temperatury. Zaproponowano mechanizm korozji warstwy wierzchniej stopu.
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on polyvinyl coating using 2-wire probe sample 1
Open Research DataThe dataset presents impedance spectrum of polyvinyl coating (code-name PW_2_2_1) sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on polyvinyl coating using 2-wire probe sample 2
Open Research DataThe dataset presents impedance spectrum of polyvinyl coating (code-name PW_2_2_1) sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 2
Open Research DataThe dataset presents impedance spectrum of nano-nickel based coating sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 1
Open Research DataThe dataset presents impedance spectrum of nano-nickel based coating sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
Impulse and high frequency methods of lighting earthing testes.
PublicationUziemienia projektowane dla prądów zwarciowych nie zawsze są właściwe do odprowadzania prądów piorunowych, gdzie należy brać pod uwagę impedancję uziemień. W pracy porównano metody: udarową oraz wysokiej częstotliwości zastosowane do oceny przydatności uziemień odgromowych.
-
Stan wiedzy na temat analizy pyłów z wykorzystaniem mikroskopii elektronowej
PublicationDo oceny stopnia zanieczyszczenia środowiska wykorzystuje się różnorodne metody i techniki analityczne. Jedną z metod jest mikroskopia elektronowa, która może być wykorzystana także do monitoringu jakości powietrza, a w szczególności pyłów, których wielkość jest tak mała, że nie mogą być obserwowane z wykorzystaniem mikroskopii optycznej.W 2006 roku badania pyłów z wykorzystaniem mikroskopii elektronowej rozpoczęto także na Politechnice...
-
Electronic structure of PrBa2Cu3O7 after high-pressure compressionfrom first principles
PublicationW pracy zbadano wpływ ściskania wysokociśnieniowego (P=9GPa) na elektronową strukturę pasmową, rozkład ładunku i momenty magnetyczne w pełni utlenionego stechiometrycznego układu PrBa2Cu3O7. Zaobserwowano następujące zmiany wywołane ściskaniem: (1) zmniejszoną gęstość stanów (DOS) na poziomie Fermiego Ef, (2) zwiększona różnicę pomiędzy wartościami DOS dla stanów "spin-up" i "spin-down" w najbliższym otoczeniu Ef, (3) zmniejszone...
-
Electrochemical Charakterization of Prussian blue type nickel hexacyanoferrate redox mediator for potential application as charge relay in dye-sensitized solar cells
PublicationMateriał nieorganiczny o mieszanym przewodnictwie elektronowo jonowym jakim jest heksacyjanożelazian (II,III) niklu (II) (NiHCF) rozpatrywany był jako potencjalny przenośnik ładunku w ogniwach słonecznych sensybilizowanych pigmentem (DSSC). Stwierdzono, że reakcje redoksowe NiHCF są szybkie i odwracalne nie tylko w obecności elektrolitu wspomagającego ale również w stanie stałym. Użyteczność NiHCF zbadana została za pomocą tradycyjnego...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 2
Open Research DataThe dataset presents impedance spectrum of epoxy based coating (code-name B2_B3) sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 1
Open Research DataThe dataset presents impedance spectrum of epoxy based coating (code-name B2_B3) sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 3
Open Research DataThe dataset presents impedance spectrum of epoxy based coating (code-name EPCS1) sample 3. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...