Filters
total: 1152
-
Catalog
- Publications 887 available results
- Journals 15 available results
- People 24 available results
- Inventions 4 available results
- Projects 8 available results
- Research Equipment 11 available results
- e-Learning Courses 16 available results
- Events 10 available results
- Open Research Data 177 available results
displaying 1000 best results Help
Search results for: VORTEX GENERATORS
-
A Wind Energy Conversion System Based on a Generator with Modulated Magnetic Flux
PublicationIn this work, the concept of an energy conversion system for wind turbines based on the modified permanent magnet synchronous generator (PMSG) is presented. In the generator, a pair of three-phase windings is used, one of which is connected in a “star” and the second in a “delta” configuration. At the outputs of both windings, two six-pulse uncontrolled (diode) rectifiers are included. These rectifiers are mutually coupled by a...
-
Comparative Study of Integer and Non-Integer Order Models of Synchronous Generator
PublicationThis article presents a comparison between integer and non-integer order modelling of a synchronous generator, in the frequency domain as well as in the time domain. The classical integer order model was compared to one containing half -order systems. The half-order systems are represented in a Park d-q axis equivalent circuit as impedances modelled by half-order transmittances. Using a direct method based on the approximation...
-
Design of synchronous generator voltage regulator based on h control theory
PublicationThe power system is highly nonlinear system, which dynamics depends on system network configuration, system loading…etc. To overcome the above mentioned difficulties and to fulfill the performance requirements the different control methods are considered and tested for application to generating control unit. Application of the H optimization method to automatic voltage regulator is studied in this paper. Simulation results have...
-
Generator synchroniczny jako regulowane źródło napięcia i mocy biernej
PublicationW referacie przedstawiono problemy sterowania i regulacji generatora synchronicznego jako podstawowego elementu hierarchicznej wielopoziomowej struktury regulacji napięć i rozpływu mocy biernej w krajowym systemie elektro-energetycznym.
-
Design of synchronous generator voltage regulator based on H control theory
PublicationSystemy dużej mocy są z reguły systemami o dużej nieliniowości. Wynika to z dynamiki takiego obiektu jak również jego konfiguracji itd. Istnieje wiele metod umożliwiających sterowanie czy testowanie zaprojektowanych generatorów. W artykule analizowana jest metoda projektowania regulatora napięcia w oparciu o H. Wyniki symulacji są zadowalające, ponieważ tak zaprojektowany regulator lepiej tłumi kołysania elektromechaniczne niż...
-
Control of a wind power generator in case of voltage sags in power network
PublicationW artykule poruszono problem związany ze sposobem sterowania generatorem elektrowni wiatrowej w przypadku wystąpienia po stronie sieci zapadów napięcia.Jako generator wykorzystano maszynę dwustronnie zasilaną której stojan podłączono bezpośrednio do sieci natomiast wirnik zasilano poprzez kaskadę przekształtników. Wystąpienie spadku lub zapadu napięcia sieci w przypadku pracy tego typu generatora może doprowadzić do uszkodzenia...
-
Voltage Control of a Stand-Alone Multiphase Doubly Fed Induction Generator
PublicationThis article presents a multiphase doubly fed induction generator (MDFIG) with a dedicated and unique control algorithm in a stand-alone wind energy conversion system. The algorithm has been developed and elaborated in the case of different emergency modes. Compared with the traditional double-fed induction generator, the MDFIG has increased reliability, reduced current level per phase, and low rotor harmonic currents. The control...
-
Advanced Control Structures of Turbo Generator System of Nuclear Power Plant
PublicationIn the paper a synthesis of advanced control structures of turbine and synchronous generator for nuclear power plant working under changing operating conditions (supplied power level) is presented. It is based on the nonlinear models of the steam turbine and synchronous generator cooperating with the power system. Considered control structure consists of multi-regional fuzzy control systems with local linear controllers, including...
-
Feedback Control of Doubly-Fed Generator Connected to Current Source Converter
PublicationDoubly-fed induction generator (DFIG) system supplied by current source converter (CSC) is considered in this article. The DFIG can work in two independent modes: AC grid connection and stand-alone mode. The DFIG is connected to the ac grid directly through its stator and the CSC links the rotor side. In this mode, the active and reactive powers of the DFIG must be controlled. This article proposes two control system structures...
-
Estimation of Synchronous Generator and AVR Parameters Based on Gradient and Genetic Methods
PublicationThe author present a method for the estimation of selected synchronous generator model and AVR parameters using a gradient and a genetic algorithm. The paper shows an example of model parameter estimation for a turbogenerator, based on the generator voltage time responses obtained during an active and reactive power rejection test
-
Identification and non-integer order modelling of synchronous machines operating as generator
PublicationThis paper presents an original mathematical model of a synchronous generator using derivatives of fractional order. In contrast to classical models composed of a large number of R-L ladders, it comprises half-order impedances, which enable the accurate description of the electromagnetic induction phenomena in a wide frequency range, while minimizing the order and number of model parameters. The proposed model takes into account...
-
Failure of austenitic stainless steel tubes during steam generator operation
PublicationThe article presents the failure process of austenitic stainless steels used in power devices, such as heat exchangers, steam generators, in terms of local corrosion: pitting, stress and intergranular corrosion, paying particular attention to welded joints area. The effect of steel chemical composition, microstructure, welding process and work environment was analyzed. The second part of the article presents the results of the...
-
Application of the Harmonic Balance Method for Spatial Harmonic Interactions Analysis in Axial Flux PM Generators
Publication -
Podsystem wizualizacji w adaptacyjnym synchronizatorze prądnic =The vizualizzation subsystem of adaptabile synchronizer of power generators
PublicationZamieszczono opis podsystemu wizualizacji układu automatycznej synchronizacji układu autopmatycznej synchronizacji prądnic pracującego wg opracowanej adaptacyjnej metody synchronizacji. Zawarto synchronizacje dot. zadań podsystemu wizualizacji wraz z prezentacją wybranych okien graficznego interfejsu uzytkownika. Omówiono również sposób realizacji podsystemu wizualizacji. Zwrócono uwagę na znaczenie i rolę dobrze zorganizowanej...
-
Realizacja stanowiska badawczego synchronizacji obiektów elektroenergetycznych = The realization of the reserch station of synchronazing power generators
PublicationW artykule opisano sposób realizacji układu automatycznej synchronizacji obiektów elektroenergetycznych pracującego według opracowanej metody. Skupiono się na opisie sposobu praktycznej realizacji układu, nie zaś na opisie samej metody synchronizacji, której opis można znaleźć w podanych w przypisach pozycjach literaturowych. Dokonano charakterystyki stanowiska badawczego z podaniem wymagań oraz wyróżnieniem poszczególnych składowych...
-
Problem of optimal load distribution between generators minimizing risk of enegretic ship system overload.
PublicationOmówiono system rozdziału mocy czynnych pomiędzy generatorami w systemie energetycznym statku. Minimalizuje się ryzyko przeciążeń systemu przy jednoczesnej minimalizacji kosztów wytwarzania energii w systemie.
-
A cortex-like model for animal recognition based on texture using feature-selective hashing
Publication -
Similarities and Differences Between the Vertex Cover Number and the Weakly Connected Domination Number of a Graph
PublicationA vertex cover of a graph G = (V, E) is a set X ⊂ V such that each edge of G is incident to at least one vertex of X. The ve cardinality of a vertex cover of G. A dominating set D ⊆ V is a weakly connected dominating set of G if the subgraph G[D]w = (N[D], Ew) weakly induced by D, is connected, where Ew is the set of all edges having at least one vertex in D. The weakly connected domination number γw(G) of G is the minimum cardinality...
-
INFLUENCE OF A VERTEX REMOVING ON THE CONNECTED DOMINATION NUMBER – APPLICATION TO AD-HOC WIRELESS NETWORKS
PublicationA minimum connected dominating set (MCDS) can be used as virtual backbone in ad-hoc wireless networks for efficient routing and broadcasting tasks. To find the MCDS is an NP- complete problem even in unit disk graphs. Many suboptimal algorithms are reported in the literature to find the MCDS using local information instead to use global network knowledge, achieving an important reduction in complexity. Since a wireless network...
-
An Experimental and Numerical Study of the Vortces Generated by Hydrofoils
PublicationArtykuł przedstawia wyniki projektu badawczego poświęconego wirom generowanym przez płaty nośne. W części eksperymentalnej wykonano anemometrem laserowym pomiary pól prędkości w poprzecznych przekrojach wirów. W częsci numerycznej przeprowadzono obliczenia używając różnych struktur siatki obliczeniowej i różnych modeli turbulencji. Na podstawie porównania wybrano model turbulencji i strukturę siatki najlepiej odzwieciedlające pole...
-
Miejsce logistyki w zarządzaniu strategicznym portem.
PublicationPodwyższenie poziomu zdolności konkurencyjnych portów zarówno w sferze kosztowej jak i jakościowej warunkowane jest aktywnym wprowadzeniem systemów logistycznych do portów morskich. Logistyka wychodzi naprzeciw postępującym zjawiskom integracyjnym w transporcie morsko-lądowym i określa oraz wzmacnia rolę portów w międzynarodowych łańcuchach transportowych, które wychodzą daleko poza port. W opracowaniu przedstawiono koncepcję...
-
Ekspertyza materiałowa osłon palników generatorów gazów obojętnych
PublicationNa zlecenie firmy PIROMETAL z Gdańska wykonano badania materiałowe osłon palników generatorów gazów obojętnych. Wykonano analizy składu chemicznego 4 próbek pobranych z osłon palników, identyfikację zastosowanych materiałów.Przeprowadzono analizę przydatności zastosowanych stali na osłony palników oraz przedstawiono opinię nt. doboru materiału na osłony palnika w generatorach gazów obojętnych.
-
Koordynacja algorytmów działania regulatora transformatora blokowego z wieloparametrowym regulatorem generatora
PublicationArtykuł przedstawia wady i zalety różnych rozwiązań podziału kryteriów regulacji pomiędzy regulator generatora a regulator transformatora blokowego. Rozważania teoretyczne zilustrowane zostały wynikami badań modelowych.
-
Generatory labiryntów: modyfikacje algorytmu komórkowego i analiza właściwości generowanej klasy
PublicationWyróżniamy trzy podstawowe algorytmy generujące labirynty, których grafowa reprezentacja ma postać drzew: błądzenia losowego, budowania ścian i komórkowy[1]. W pracy przedstawione zostaną modyfikacje algorytmu komórkowego, które potrafią wygenerować tę samą klasę labiryntów, co podstawowa wersja algorytmu, przy jednoczesnej zmianie parametrów opisujących ich wygląd (preferencja kierunku wyjścia, średnia liczba wyjść z pokoju, średnia...
-
Wielkopowierzchniowe obiekty handlowe - zwykłe generatory ruchu czy źródła problemów transportowych?
PublicationW artykule zaprezentowano dane na temat funkcjonowania dużych centrów handlowych w miastach, uzyskane z polskich i obcojęzycznych źródeł literatury oraz badań realizowanych w Polsce i za granicą. Przedstawione zagadnienia pozwalają na zapoznanie się z podstawową wiedzą na temat zachowań klientów oraz poznanie uwarunkowań określania oferty parkingowej wielkopowierzchniowych obiektów handlowych. Przedstawiono także charakterystyki...
-
Functional singlet oxygen generators based on porphyrazines with peripheral 2,5-dimethylpyrrol-1-yl and dimethylamino groups
Publication -
Effects of La0.8Sr0.2MnO3 and Ag electrodes on bismuth-oxide-based low-temperature solid electrolyte oxygen generators
PublicationIn this study, La0.8Sr0.2MnO3 (LSM) was used as the ceramic electrode in a (Bi1.50Y0.50)0.98Zr0.04O3+δ (BYO)-based solid electrolyte oxygen generator (SEOG) and its performance was compared with that of a previously studied high-fire Ag electrode. Among La0.6Sr0.4Co0.2Fe0.8O3, LaNi0.6Fe0.4O3, Cu1.4Mn1.6O4, and LSM materials, only LSM materials did not trigger any chemical reaction or interdiffusion with BYO at temperatures up to...
-
Dielectric Barrier Discharge Systems with HV Generators and Discharge Chambers for Surface Treatment and Decontamination of Organic Products
PublicationThe article presents applications of systems with power electronic converters, high voltage transformers, and discharge chambers used for nonthermal, dielectric barrier discharge plasma treatment of a plastic surface and decontamination of organic loose products. In these installations, the inductance of the high voltage transformers and the capacitances of the electrode sets form resonant circuits that are excited by inverters....
-
A rapid spectrofluorimetric method for the determination of malondialdehyde in human plasma after its derivatization with thiobarbituric acid and vortex assisted liquid–liquid microextraction
Publication -
Optimization of vortex-assisted hydrophobic magnetic deep eutectic solvent-based dispersive liquid phase microextraction for quantification of niclosamide in real samples
PublicationIn this manuscript, a green and fast vortex-assisted hydrophobic magnetic deep eutectic solvent-based dispersive liquid phase microextraction (VA-HMDES-DLPME) method was developed for the selective extraction and determination of niclosamide in read samples, including rice, medicine tablets, and water samples. Here, hydrophobic magnetic deep eutectic solvents were used as the extracting solvent without requiring any centrifugation...
-
Technical evaluation of marine auxiliary diesel engine on the basis of parameters synchronous generator
PublicationThe article presents a method for evaluating the technical condition of selected structural elements of the reciprocating internal combustion engine driving a synchronous generator. Th results of measurements of the electric generator parameters are the diagnostic information source. On this basis it is possible to determine the instantaneous angular speed marine engine crankshaft which, in turn, is the basis for reasoning about...
-
Low speed permanent magnet synchronous generator for vertical axis wind turbine
PublicationThe paper presents design process and tests of a prototype low speed permanent magnet synchronous generator (PMSG) dedicated for the innovative vertical-axis wind turbine. The rated data of the designed generator are following: power - 15 kVA, voltage - 400 V (Y), rotation speed - 93.75 rpm. The design assumptions, chosen results of the design process and experimental tests of the prototype PMSG are presented. The considered PMSG...
-
Synchronous generator model taking into account the non-uniform saturation of the pole shoes
PublicationFor the evaluation of modern electric power systems with regard to their behavior, weight, and reliability a novel modeling and simulation tools have been developed. The paper presents circuit model of synchronous generator taking into account both the non-sinusoidal distribution of the stator and rotor winding, and non-uniform saturation of the pole shoes. This model is suitable for simulation of both salient and no-salient pole...
-
Steady State Analysis of Twin Stator Cascaded Doubly Fed Induction Generator
Publication -
Nonlinear model of a synchronous generator for analysis of more electric aircraft power systems
PublicationA nonlinear model for studying a variable-speed synchronous generator (SG) in more electric aircraft (MEA) power system has been developed. The saturation effects of the SG magnetic circuit have been considered. The model has been implemented in the Synopys/Saber simulation environment. The modelling language MAST has been used to elaborate the SG model. The model exhibit a network with the same number of external terminals/ports...
-
Design advantages and analysis of a novel five-phase doubly-fed induction generator
PublicationPurpose – The purpose of this paper is to provide an analysis of the performance of a new five-phase doubly fed induction generator (DFIG). Design/methodology/approach – This paper presents the results of a research work related to fivephase DFIG framing, including the development of an analytical model, FEM analysis as well as the results of laboratory tests of the prototype. The proposed behavioral level analytical model is based...
-
Power System Stabilizer as a Part of a Generator MPC Adaptive Predictive Control System
PublicationIn this paper, a model predictive controller based on a generator model for prediction purposes is proposed to replace a standard generator controller with a stabilizer of a power system. Such a local controller utilizes an input-output model of the system taking into consideration not only a generator voltage Ug but also an additional, auxiliary signal (e.g., α, Pg, or ωg). This additional piece of information allows for taking...
-
Numbers, Please: Power- and Voltage-Related Indices in Control of a Turbine-Generator Set
PublicationThis paper discusses the proper selection and interpretation of aggregated control performance indices values mirroring the quality of electrical energy generation by a turbine-generator set cooperating with a power system. Typically, a set of basic/classical and individual indices is used in energy engineering to ensure the mirroring feature and is related to voltage, frequency and active or reactive power deviations from their...
-
Fault-tolerant performance of the novel five-phase doubly-fed induction generator
PublicationThe article presents the concept of a new design of a multi-phase doubly-fed induction generator (DFIG). The innovative design approach uses a five-phase power supply from the rotor side of the generator with a three-phase classic stator power supply. Modern three-phase doubly-fed induction generators are the dominant choice for Wind Energy Conversion Systems (WECS). Solutions of this type are sensitive to the loss of at least...
-
Self-Adaptive Mesh Generator for Global Complex Roots and Poles Finding Algorithm
PublicationIn any global method of searching for roots and poles, increasing the number of samples increases the chances of finding them precisely in a given area. However, the global complex roots and poles finding algorithm (GRPF) (as one of the few) has direct control over the accuracy of the results. In addition, this algorithm has a simple condition for finding all roots and poles in a given area: it only requires a sufficiently dense...
-
Real-time hybrid model of a wind turbine with doubly fed induction generator
PublicationIn recent years renewable sources have been dominating power system. The share of wind power in energy production increases year by year, which meets the need to protect the environment. Possibility of conducting, not only computer simulation, but also laboratory studies of wind turbine operation and impact on the power system and other power devices in laboratory conditions would be very useful. This article presents a method...
-
The distributed model predictive controller for the nuclear power plant turbo-generator set
PublicationTypically there are two main control loops with PI controllers operating at each turbo-generator set. In this paper a distributed model predictive controller DMPC, with local QDMC controllers for the turbine generator, is proposed instead of a typical PI controllers. The local QDMC controllers utilize step-response models for the controlled system components. These models parameters are determined based on the proposed black-box...
-
A model development and experimental verification for a vapour microturbine with a permanent magnet synchronous generator
PublicationVapour microturbines with permanent magnet synchronous generators are implemented in micropower plants for dispersed power generation systems. The dynamic model of such a microturbine set was developed and presented. The developed relations result from the generic equations. Experimental data for two different working medium were used for model verification. A microturbine set model was tested during the changes in the parameters...
-
Design of synchronous generator two inputs regulator based on hinf control theory.
PublicationThe power system is highly nonlinear system, its dynamics depends on system network configuration, system loading… etc. To overcome the above mentioned difficulties and fulfill the performance requirements the different control methods are considered and tested for design of synchronous generator control system. Application of the H optimization method to synchronous generator regulator based on measurement of generator voltage...
-
Mild poikilocapnic hypoxia increases very low frequency haemoglobin oxygenation oscillations in prefrontal cortex
PublicationBackground: The aim of the study was to investigate the effect of mild cerebral hypoxia on haemoglobin oxygenation(HbO2), cerebrospinal fluid dynamics and cardiovascular physiology. To achieve this goal, four signals were recorded simultaneously: blood pressure, heart rate / electrocardiogram, HbO2 from right hemisphere and changes of subarachnoid space (SAS) width from left hemisphere. Signals were registered from 30 healthy,...
-
Układ sterowania małą elektrownią wiatrową z generatorem indukcyjnym
PublicationW referacie przedstawiono układ sterowania małej, zasilanej z 1 fazy elektrowni wiatrowej, w której wykorzystano generator indukcyjnyz przekształtnikiem energoelektronicznym i zasobnikiem energii w postaci kondensatora i dławika. Przeprowadzono badania symulacyjne zasobnika energii oraz przedstawiono realizację aplikacyjną z silnikiem wiatrowym o mocy 12kW. Badania symulacyjne jak i doświadczenia eksploatacyjne wykazały dobre właściwości...
-
Układy i schematy zastępcze impusowych generatorów wielkiej mocy
PublicationW pracy przedstawiono generatory impulsowe wielkiej mocy. Generatory te stanowią źródła energii elektrycznej w badaniach fizycznych i technicznych zjawisk o krótkim czasie trwania, wymagających wielkiej mocy. Podano opis, schematy, ważniejsze parametry i odpowiednie zależności charakteryzujące parametry tych generatorów. Przedstawiono dwa główne rodzaje generatorów, tzn. impulsowe generatory pojemnościowe i impulsowe generatory...
-
Badania laboratoryjne wybranych sposobów koordynacji regulatora transformatora blokowego oraz regulatora generatora
PublicationWprowadzenie wymogu stosowania transformatorów blokowych z przekładnią regulowaną pod obciążeniem spowodowało konieczność określenia właściwego sposobu podziału kryteriów sterowania pomiędzy regulator generatora a regulator transformatora blokowego. W referacie zwrócono uwagę na aspekt miejsca pomiaru napięć. Ma to istotny wpływ zarówno na algorytm jak i jakość regulacji. Rozważania teoretyczne zilustrowane zostały wynikami prób...
-
SYMULACJA SZEROKOPASMOWEGO GENERATORA SYGNAŁÓW ZAKŁÓCAJĄCYCH DLA POTRZEB OCHRONY PRZED RC-IED
PublicationReferat został poświęcony symulacji działania generatora zakłóceń szerokopasmowych z uwzględnieniem efektów występujących w rzeczywistym urządzeniu i determinujących kształt widma nadawanego sygnału. W artykule zawarto podstawowe informacje dotyczące projektu Aegis, w ramach którego powstaje mobilny generator kurtyny EM. Następnie opisano przyjęty model symulacyjny, uwzględniający czynniki warunkujące postać sygnału na wyjściu...
-
Praca regulatora generatora w warunkach sprzyjających powstawaniu lawiny napięcia - wybrane problemy
PublicationW referacie zwrócono uwagę na wybrane zagadnienia związane z pracą wieloparamatrowego regulatora generatora w warunkach awarii napięciowej. Przedstawiono wyniki analizy wpływu, tak często pomijanego elementu układu regulatora generatora, jakim jest stabilizator systemowy. Zwrócono uwagę na celowość automatyzacji procesu zaniżania mocy czynnej, dla zwiększenia możliwości generacji mocy biernej. Ponadto, wskazano błędy w strukturze...