Filters
total: 403
-
Catalog
Search results for: implanty kardiologiczne
-
REVIEW OF CURRENT RESEARCH ON CHITOSAN AS A RAW MATERIAL IN THREE-DIMENSIONAL PRINTING TECHNOLOGY IN BIOMEDICAL APPLICATIONS
PublicationThree-dimensional (3D) biomaterial manufacturing strategies show an extraordinary driving force for the development of innovative solutions in the biomedical sector, including drug delivery systems, disease modelling and tissue and organ engineering. Due to its remarkable and promising biological and structural properties, chitosan has been widely studied for decades in several potential applications in the biomedical field. However,...
-
Types of wear and tear of biomaterials used in orthopaedic surgery
PublicationPurpose of this paper is presentation of observations on different kinds of wear and tear of biomaterials used in contemporary orthopaedic surgery. Types of prosthesis damage, encountered in medical practice, and their causes have been described. Results of many clinical studies were analysed to review prosthesis damage from the stage of implanting (such as intrusion of a foreign object between its components) to their natural...
-
Stenty naczyniowe – problematyka i biomateriały
PublicationAngioplastyka z opcjonalną implantacją stentu odgrywa ważną rolę w leczeniu chorób układu sercowo-naczyniowego w przebiegu miażdżycy. Obecnie na rynku można znaleźć implanty naczyniowe z różnych materiałów, pomimo tego nadal prowadzone są badania nad nowymi technologiami zapewniającymi lepsze własności mechaniczne, fizykochemiczne i biologiczne powłokom, a także usprawniającymi sposoby uwalniania leków. Stenty uwalniające leki...
-
Modelling of abdominal wall with hernia and implant within stochastic framework
ProjectsProject realized in Faculty of Civil and Environmental Engineering according to UMO-2015/17/N/ST8/02705 agreement from 2016-01-18
-
Sposób mocowania implantu w wideoskopowych operacjach przepuklin brzusznych
Inventions -
Influence of Two-Stage Anodization on Properties of the Oxide Coatings on the Ti–13Nb–13Zr Alloy
PublicationThe increasing demand for titanium and its alloys used for implants results in need of such innovative surface treatment that may jointly increase corrosion resistance and biocompatibility, and demonstrate antibacterial protection at no cytotoxicity. The purpose of this research was to characterize the effect of two-stage anodization, performed for 30 min in phosphoric acid, at the presence of hydrofluoric acid in the second stage....
-
The effect of dehydration/rehydration of bacterial nanocellulose on its tensile strength and physicochemical properties
PublicationBacterial nanocellulose (BNC) is a natural biomaterial with a wide range of biomedical applications. BNC contains 99 % of water which makes it too thick to be used as a bioimplant material. The aim of the work was to determine the effect of the BNC dehydration followed by rehydration on its mechanical and physicochemical properties, in the context of the use of BNC as bio-prostheses in the cardiovascular system. Dehydration involved the...
-
The Production Possibility of the Antimicrobial Filaments by Co-Extrusion of the PLA Pellet with Chitosan Powder for FDM 3D Printing Technology
PublicationThe last decades have witnessed a major advancement and development in three-dimensional (3D) printing technology. In the future, the trend’s utilization of 3D printing is expected to play an important role in the biomedical field. This work presents co-extrusion of the polylactic acid (PLA), its derivatives (sPLA), and chitosan with the aim of achieving filaments for printing 3D objects, such as biomedical tools or implants. The...
-
Effect of Laser Treatment on Intrinsic Mechanical Stresses in Titanium and Some of Its Alloys
PublicationLaser surface treatment conducted at different power levels is an option to modify titanium bone implants to produce nano- and microtopography. However, such processing can lead to excess mechanical stress within the surface layer. This research aims to calculate the level of such residual stresses after the surface processing of Ti grade IV, Ti15Mo, and Ti6Al7Nb alloys with an Nd:YAG laser. Light and scanning electron microscopies...
-
Powikłania po rekonstrukcji piersi: problem zakażeń i strategii prewencyjnej - przegląd literaturowy
PublicationW niniejszej pracy przedstawiono dane dotyczące powikłań po rekonstrukcji piersi. Manuskrypt ma na celu usystematyzowanie wyników badań z ostatnich lat wraz z aspektami, takimi jak: częstotliwość występowania powikłań oraz ich rodzaj, czynniki predysponujące, a także możliwości profilaktyki. Przeanalizowano dane literaturowe z ogólnie dostępnych artykułów z okresu ostatnich pięciu lat, ze szczególnym uwzględnieniem zakażeń. Do...
-
Zespół Biomateriałów
Research TeamsInżynieria i technologia biomateriałów, inżynieria powierzchni, wytwarzanie implantów metalowych, rozwój materiałów odpornych na korozję
-
The Effect of Surface Modification of Ti13Zr13Nb Alloy on Adhesion of Antibiotic and Nanosilver-Loaded Bone Cement Coatings Dedicated for Application as Spacers
PublicationSpacers, in terms of instruments used in revision surgery for the local treatment of postoperative infection, are usually made of metal rod covered by antibiotic-loaded bone cement. One of the main limitations of this temporary implant is the debonding effect of metal–bone cement interface, leading to aseptic loosening. Material selection, as well as surface treatment, should be evaluated in order to minimize the risk of fraction...
-
Wpływ warunków spawania na skłonność do tworzenia pęknięć zimnych przy spawaniu pod wodą
PublicationPrzedmiotem pracy było określenie skłonności do tworzenia pęknięć zimnych złączy spawanych ze stali 18G2A wykonanych pod wodą metodą lokalnej komory suchej. Problem rozwiązano przy zastosowaniu teorii planowania badań. Określono ilościowy wpływ parametrów spawania: wydatku gazu osłonowego oraz energii liniowej spawania na naprężenia krytyczne z próby implant, wskaźnik skłonności do tworzenia pęknięć zimnych, twardość maksymalną...
-
Recent advances in electrochemically surface treated titanium and its alloys for biomedical applications: A review of anodic and plasma electrolytic oxidation methods
PublicationNowadays, titanium and its alloys are widely used materials in implantology. Nevertheless, the greatest challenge is still its appropriate surface treatment in order to induce optimal properties, which facilitates formation of a permanent bond between the implant and human tissue. The use of electrochemical treatment such as anodic oxidation or plasma electrolytic oxidation allows for the production of porous coating that mimics...
-
Titania Nanotubes/Hydroxyapatite Nanocomposites Produced with the Use of the Atomic Layer Deposition Technique: Estimation of Bioactivity and Nanomechanical Properties
PublicationTitanium dioxide nanotubes/hydroxyapatite nanocomposites were produced on a titanium alloy (Ti6Al4V/TNT/HA) and studied as a biocompatible coating for an implant surface modification. As a novel approach for this type of nanocomposite fabrication, the atomic layer deposition (ALD) method with an extremely low number of cycles was used to enrich titania nanotubes (TNT) with a very thin hydroxyapatite coating. X-ray diffraction (XRD)...
-
EXAMINATION OF SOL-GEL DERIVED HYDROXYAPATITE ENHANCED WITH SILVER NANOPARTICLES USING OCT AND RAMAN SPECTROSCOPY
PublicationHydroxyapatite (HAp) has been attracting widespread interest in medical applications. In a form of coating, it enables to create a durable bond between an implant and surrounding bone tissues. With addition of silver nanoparticles HAp should also provide antibacterial activity. The aim of this research was to evaluate the composition of hydroxyapatite with silver nanoparticles in a non-destructive and non-contact way. For control measurements...
-
The Chemical and Biological Properties of Nanohydroxyapatite Coatings with Antibacterial Nanometals, Obtained in the Electrophoretic Process on the Ti13Zr13Nb Alloy
PublicationThe risk of an early inflammation after implantation surgery of titanium implants has caused the development of different antimicrobial measures. The present research is aimed at characterizing the effects of nanosilver and nanocopper dispersed in the nanohydroxyapatite coatings, deposited on the Ti13Zr13Nb alloy, and on the chemical and biological properties of the coatings.The one-stage deposition process was performed by the...
-
Electrophoretic Deposition and Characteristics of Chitosan–Nanosilver Composite Coatings on a Nanotubular TiO2 Layer
PublicationThe surface treatment of titanium implants has been applied mainly to increase surface bioactivity and, more recently, to introduce antibacterial properties. To this end, composite coatings have been investigated, particularly those based on hydroxyapatite. The present research was aimed at the development of another coating type, chitosan–nanosilver, deposited on a Ti13Zr13Nb alloy. The research comprised characterization of the...
-
Influence of silver nanoparticles addition on antibacterial properties of PEO coatings formed on magnesium
PublicationMagnesium is a biodegradable material and thus could be a choice for bone fixation devices and implants with a specific purpose. This study aims to enhance the anti-corrosive, biocompatible, and antibacterial properties on magnesium-based materials through ceramic coatings formation. To achieve this the silicate-based electrolyte was used to create of Plasma Electrolytic Oxidation (PEO) coatings. During investigation the bioactive...
-
Rafał Jesiołkiewicz mgr inż.
PeopleCurrently, he is a doctoral student at the PhD Doctoral School at the University of Gdańsk and coordinator of the Scientific Club "Materials in Medicine" at the University of Gdańsk. https://www.facebook.com/knbiomaterialow/ Scientific Titles: Nanotechnology Engineer with specialization: nanomaterials in medicine and cosmetology [PG]. Master of Science in Mechanical and Medical Engineering, specializing in: modern medical structures...
-
Effect of double thermal and electrochemical oxidation on titanium alloys for medical applications
PublicationThe research focuses on the development and characterization of innovative thin hybrid oxide coatings obtained in subsequent processes of thermal (TO) and electrochemical (EO) oxidation. Four different surface modifications were investigated and the microstructure was determined, the mechanical, chemical and biological properties of the Ti-13Nb-13Zr alloy were assessed using scanning electron microscopy, X-ray dispersion analysis,...
-
A Probe into the Corrosion Behavior of a WE43B Magnesium Alloy in a Simulated Body Fluid using Dynamic Electrochemical Impedance Spectroscopy
PublicationWE43B is one of the newest Mg alloys with practical application in biomedical implant technology. This work attempts to scrutinize the corrosion characteristics of WE43B alloy in a simulated body fluid (SBF) at a typical body temperature. The dynamic-electrochemical impedance spectroscopy with the capacity to track changes on surfaces in a dynamic corrosive system is used in combination with other classical techniques namely, linear...
-
High meniscal slope angle as a risk factor for meniscal allograft extrusion
PublicationA meniscal graft extrusion is still an unresolved problem that affects most patients after a meniscal transplantation. Despite the advances in surgical techniques, together with the improved methods for a meniscal allograft sizing, success is only observed in up to 75% of patients after they experience a meniscal allograft transplantation. Because a meniscal extrusion is associated with a cartilage deterioration and the progression...
-
Antimicrobal and ostheointegration activity of bone cement contains nanometals
PublicationPurpose: One of the major problems in bone surgery are infections – especially thoseoccurring in the course of the operating on the patients with lowered immunity system,because they carry the danger of complications. In the Mechanical Department of TechnicalUniversity of Gdansk, there has been carried the research with the use of bone cement andmetal nanoparticles.Design/methodology/approach: The bone cement was used without supplement...
-
Corrosion of titanium biomaterials, mechanisms, effects and modelisation
PublicationBadania in vivo oraz in vitro wskazują na bardzo małą szybkość korozji biostopów tytanu.Najczęstsza przycyną jest korozja ogólna i lokalna oraz korozja frettingowa. Trzy możliwe mechanizmy to: rozpuszczanie warstwy tlenku tytanu, dyfuzja pierwiastków przez warstwę tlenkową oraz reakcje elektrochemiczna w środowisku korozyjnym odsłoniętego metalu. Procesy korozyjne prowadzą do obluzowania implantów i poważnych schorzeń. Standardowe...
-
Application of BAN Network to Increase Security in Transport Systems
PublicationIn the article general characteristics of the BAN network with M2M communications are presented. These are networks that enable the implementation of wireless transmission of signals using special sensors located on the body or implanted subcutaneously. These sensors allow monitoring of different type life parameters of a human. In the next part of work there is proposed the implementation of BAN networks to transport systems as...
-
Wytwarzanie, budowa i właściwości warstw tlenkowych uzyskanych na stopach tytanu do zastosowań biomedycznych
PublicationPraca koncentruje się na zagadnieniach związanych z metodami modyfikacji warstwy wierzchniej stopów tytanu, z ukierunkowaniem na stop tytanu Ti13Nb13Zr, którego skład chemiczny stanowią pierwiastki obojętne dla organizmu żywego, a moduł Yong’a jest zbliżony do kości. Odpowiednia modyfikacja warstwy wierzchniej umożliwia przyspieszenie procesów łączenia żywej tkanki z wprowadzonym elementem i powoduje wydłużenie czasu użytkowania...
-
Corrosion degradation of spacers – examination of changes in bone cement coating.
PublicationSpacer is a special implant used at the time of infection after endoprosthetic surgery. It consists of a metal core and bone cement coating with an antibiotic. In the human body spacers are exposed to degradation processes. This paper looks at the effect of corrosion on spacers. Electrochemical corrosion tests were performer on titanium pins with bone cement coating in two solutions: Ringer’s solution and artificial...
-
Properties of Nanohydroxyapatite Coatings Doped with Nanocopper, Obtained by Electrophoretic Deposition on Ti13Zr13Nb Alloy
PublicationNowadays, hydroxyapatite coatings are the most common surface modification of long-term implants. These coatings are characterized by high thickness and poor adhesion to the metallic substrate. The present research is aimed at characterizing the properties of nanohydroxyapatite (nanoHAp) with the addition of copper nanoparticle (nanoCu) coatings deposited on the Ti13Zr13Nb alloy by an electrophoresis process. The deposition of...
-
Self-organising maps in the analysis of strains of human abdominal wall to identify areas of similar mechanical behaviour.
PublicationThe study refers to the application of a type of artificial neural network called the Self-Organising Map (SOM) for the identification of areas of the human abdominal wall that behave in a similar mechanical way. The research is based on data acquired during in vivo tests using the digital image correlation technique (DIC). The mechanical behaviour of the human abdominal wall is analysed during changing intra-abdominal pressure....
-
On implementation of fibrous connective tissues’ damage in Abaqus software
PublicationConnective fibrous tissues, such as tendons and ligaments, in humans and animals exhibit hyperelastic behaviour. The constitution of the material of these tissues is anisotropic due to the presence of the collagen fibres, where one family of fibres is the typical case. Traumatic events and/or aging may sometimes lead to the damage of the tissue. The study of motion of affected joints or limbs is usually not permitted in vivo. This...
-
Optymalizacja doboru prawa konstytutywnego membrany o strukturze plecionej
PublicationCelem niniejszej dysertacji jest opracowanie zagadnienia optymalizacyjnego pozwalającego dobrać model konstytutywny opisujący mechaniczne zachowanie membrany technicznej. Do analizy wybrano membrany plecione, stosowane w medycynie, tzw. siatki chirurgiczne. W celu wykonania identyfikacji praw konstytutywnych, wykonano dwuosiowe rozciąganie próbek materiałów, otrzymując wskazanie na nieliniowe anizotropowe zachowanie materiałów....
-
ZINTEGROWANY SYSTEM DOMOWEGO MONITORINGU PARAMETRÓW MEDYCZNYCH OSÓB STARSZYCH I CHORYCH
PublicationProponowane rozwiązania mają na celu wspomaganie osób starszych i chorych, tak by mogły jak najdłużej mieszkać i żyć samodzielnie ze zwiększonym poczuciem bezpieczeństwa, iż są nadzorowane i w razie nagłego zagrożenia życia nie pozostaną bez pomocy. System jednocześnie nie narusza poczucia zachowania prywatności i intymności, gdyż nie są używane do monitoringu kamery wizyjne czy też stały nasłuch audio. Dodatkowo gromadzone informacje...
-
Biomechanical testing of bioactive bone cements – a comparison of the impact of modifiers: antibiotics and nanometals
PublicationApart from its bone filler and fracture stabilizing function, bone cement can be used as a carrier of bioactive substances, and such modified bone cement can protect the implant against microorganisms, treat local infections and combat bacteria introduced during the surgical procedure. In this paper, the effects of modifying antibiotics and nanosilver on the biomechanical properties of bone cement were examined. The following tests...
-
Antibacterial Activity and Cytocompatibility of Bone Cement Enriched with Antibiotic, Nanosilver, and Nanocopper for Bone Regeneration
PublicationBacterial infections due to bone replacement surgeries require modifications of bone cement with antibacterial components. This study aimed to investigate whether the incorporation of gentamicin or nanometals into bone cement may reduce and to what extent bacterial growth without the loss of overall cytocompatibility and adverse effects in vitro. The bone cement Cemex was used as the base material, modified either with gentamicin...
-
Sposób modyfikowania grupami bisfosfonowymi i/lub fosfonowymi materiałów węglowych zwłaszcza nanomateriałów
InventionsModyfikacji grupami bisfosfonowymi i/lub fosfonowymi poddaje się nanomateriały węglowe np. nanorurki, tlenek grafenu, węgiel aktywny, tlenek grafitu, węgiel podobny do diamentu. Zastosowanie tego sposobu umożliwia jednoetapowe, proste i niedrogie otrzymywanie materiałów węglowych z grupami bisfosfonowymi. Z procesu technologicznego łatwo usuwa się nadmiar ciekłych reagentów, z możliwością zawrócenia...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_008)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_007)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_006)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0011)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_009)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0010)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0012)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_004)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_005)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_002)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_003)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0017)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0021)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...
-
Invasive electrophysiological patient recordings from the human brain during memory tasks with pupilometry (MC_0020)
Open Research DataData comprise intracranial EEG (iEEG) brain activity, including electrocorticography (ECoG) signals, recorded from over 100 electrodes implanted in one patient throughout various brain regions. These iEEG signals were recorded in epilepsy patients undergoing invasive monitoring and localization of seizures when they were performing a battery of four...