Search results for: ELECTROMYOGRAPHY AMPLIFIER
-
SIMPLY AND LOW COAST ELECTROMYOGRAPHY SIGNAL AMPLIFIER
PublicationRecently, there has been a noticeable increase in interest in solu tions utilizing electrical signals accompanying muscle activity. Electromyography (EMG) is a technique for recording, analysis and evaluating the electrical activity produced by striated muscle. Its great popularity is due, among other, to the ability to measure with non-invasive electrodes (calle d as sEMG surface electromyography)....
-
Multiple output CMOS current amplifier
PublicationIn this paper the multiple output current amplifier basic cell is proposed. The triple output current mirror and current follower circuit are described in detail. The cell consists of a split nMOS differential pair and accompanying biasing current sources. It is suitable for low voltage operation and exhibits highly linear DC response. Through cell devices scaling, not only unity, but also any current gains are achievable. As...
-
Basic Hand Gestures Classification Based on Surface Electromyography
PublicationThis paper presents an innovative classification system for hand gestures using 2-channel surface electromyography analysis. The system developed uses the Support Vector Machine classifier, for which the kernel function and parameter optimisation are conducted additionally by the Cuckoo Search swarm algorithm. The system developed is compared with standard Support Vector Machine classifiers with various kernel functions. The average...
-
Sounding rocket vibration mechanical filter and amplifier
PublicationMeasuring accelerations and vibrations of a sounding rocket provides both information for engineers on the launcher vehicle performance as well as environment description for future payload designers. Typically, information on the level of vibration and eigenfrequencies are required to properly design a payload. This paper presents a design of a novel mechanical filter and amplifier for mechanical vibrations. Its key feature is...
-
Programmable CMOS operational transconductance amplifier OTA
PublicationW pracy przedstawiono ulepszoną wersję programowalnego wzmacniacza transkonduktacyjnego o szerokim paśmie przepustowym. Zaprojektowany wzmacniacz został przesymulowany komputerowo oraz wyprodukowany w technologii CMOS. Wyniki wskazują na ponad 450 krotną możliwość zmiany współczynnika transkonduktancji oraz 3dB pasmo częstotliwościowe leżące powyżej 300MHz. Przedstawiono również zastosowanie wzmacniacza OTA w analogowej tablicy...
-
Basic evaluation of limb exercises based on electromyography and classification methods
PublicationSymptoms caused by cerebral palsy or stroke deprive a person partially or even completely of his ability to move. Nowadays we can observe more technologically advanced rehabilitation devices which incorporate biofeedback into the process of rehabilitation of such people. However, there is still a lack of devices that would analyse, assess, and control (independently or with limited support) specialised movement exercises. Here...
-
Could thermal imaging supplement surface electromyography measurements for skeletal muscles?
PublicationAbstract—(1) Background: The aim of this study is to present the results of experiments in which surface electromyography (sEMG) and thermal imaging were used to assess muscle activation during gait and to verify the hypothesis that there is a relationship in the case of low fatigue level between sEMG measured muscle activation, assessed in the frequency domain, and thermal factors calculated as minimum, maximum, kurtosis, mean,...
-
Active-Error Feedforward Technique for Linearization of CMOS Transconductance Amplifier
PublicationW pracy przedstawiono koncepcję układową operacyjnego wzmacniacza transkonduktancyjnego CMOS o zwiększonej liniowości charakterystyk przejściowych. Proponowana struktura wzmacniacza transkonduktancyjnego opiera się na wykorzystaniu prostych transkonduktorów realizowanych za pomocą par różnicowych. Linearyzacja charakterystyki przejściowej układu następuje dzięki zastosowaniu w ścieżce "feedforward" wzmacniacza błędu. Wzmacniacz...
-
Leveraging Training Strategies of Artificial Neural Network for Classification of Multiday Electromyography Signals
Publication -
An integrated periodic structure in Silicon technology to improve power amplifier parameters
PublicationNowa zintegrowana struktura periodyczna wykonana w technologii krzemowej została wprowadzona do międzystopniowego układu dopasowania wzmacniacza mocy. Dzięki temu stwiedzono poprawę większości charakterystyk wzmacniacza, jak również własności filtrujących (tłumienie harmonicznych).
-
Receiver block of antenna amplifier for WLAN systems in 5 GHz band
PublicationDwukierunkowe wzmacniacze antenowe (BDA) są często stosowane do zwiększania zasięgu łączności w sieciach bezprzewodowych WLAN. W artykule przedstawiono teorię, procedurę projektową oraz realizację części odbiorczej dwukierunkowego wzmacniacza do systemów WLAN na pasma 5GHz w standardach 802.11a i HiperLAN-2. Analizowano tylko te bloki, które wpływają na parametry toru odbiorczego. Aby ograniczyć koszt wzmacniacza wszystkie obwody...
-
Phase compensation scheme for feedforward linearised CMOS operational transconductance amplifier.
PublicationW pracy opisano technikę kompensacji charakterystyk fazowych linearyzowanego metodą feedforward operacyjnego wzmacniacza transkonduktancyjnego CMOS. Wykazano, że proponowana koncepcja układowa prowadzi do znacznej poprawy liniowości charakterystyki przejściowej wzmacniacza oraz do rozszerzenia zakresu liniowości prądu wyjściowego. Ponadto w pracy przeprowadzono analizę charakterystyk częstotliwościowych, w wyniku której otrzymano...
-
Theoretical Investigation of Oxazine 170 Perchlorate Doped Polymeric Optical Fiber Amplifier
Publication -
Programmable Input Mode Instrumentation Amplifier Using Multiple Output Current Conveyors
PublicationIn this paper a programmable input mode instrumentation amplifier (IA) utilising second generation, multiple output current conveyors and transmission gates is presented. Its main advantage is the ability to choose a voltage or current mode of inputs by setting the voltage of two configuration nodes. The presented IA is prepared as an integrated circuit block to be used alone or as a sub-block in a microcontroller or in a field...
-
Self-Organising map neural network in the analysis of electromyography data of muscles acting at temporomandibular joint.
PublicationThe temporomandibular joint (TMJ) is the joint that via muscle action and jaw motion allows for necessary physiological performances such as mastication. Whereas mandible translates and rotates [1]. Estimation of activity of muscles acting at the TMJ provides a knowledge of activation pattern solely of a specific patient that an electromyography (EMG) examination was carried out [2]. In this work, a Self-Organising Maps (SOMs)...
-
Active Linear Tunable Resistance Element and Application to Feedforward Linearization of CMOS Transconductance Amplifier
PublicationW pracy przedstawiono koncepcję układową przestrajalnego rezystora liniowego MOS wykorzystującego tranzystory pracujące w zakresie triodowym. Opracowana struktura, jak wykazały symulacje komputerowe, charakteryzuje się dobrymi właściwościami zarówno jeżeli chodzi o zakres przestrajania jak i liniowość charakterystyk przejściowych. Pozwoliło to efektywnie wykorzystać prezentowany element do linearyzacji operacyjnego wzmacniacza...
-
Frequency compensation for two-stage operational amplifiers with improved PSRR characteristic
PublicationW pracy została opisana nowa metoda kompensacji częstotliwościowej dwustopniowych wzmacniaczy operacyjnych. Metoda kompensacji gwarantuje uzyskanie stabilnej pracy wzmacniacza operacyjnego przy założeniu że wzmocnienie układu z zamkniętą pętlą sprzężenia zwrotnego jest ograniczone do wartości kilkunastu decybeli. W porównaniu do innych znanych metod kompensacji, zaproponowana metoda umożliwia co najmniej dziesięciokrotne poszerzenie...
-
ALIS-FLP: amplified ligation selected fragment-length polymorphism method for microbial genotyping
PublicationA DNA fingerprinting method known as ALIS-FLP (amplified ligation selected fragment-length polymorphism) has been developed for selective and specific amplification of restriction fragments from TspRI restriction endonuclease digested genomic DNA. The method is similar to AFLP, but differs in that only one specific restriction enzyme (TspRI) is used. The cohesive ends of the DNA fragments are ligated with two types of oligonucleotide....
-
The current amplifier in low frequency noise measurements; Absolute calibration and rigorous 1/f noise extraction for MOSFET´s
PublicationPrzedstawiono budowę wzmacniacza prądowego i sposób obliczania szumów wyjściowych przy dołączonym do wejścia rezystorze wzorcowym. Przedstawiono wyniki eksperymentów potwierdzających prawidłowość przyjętego sposobu postępowania. Zaproponowano metodę wyznaczania składowej 1/f szumów drenu tranzystora MOSFET.
-
The Impact of Range of Motion on Applied Force Characteristics and Electromyographic Activity during Repeated Sets of Bench Press Exercise
Publication -
A Comparison of Electromyographic Inter-Limb Asymmetry during a Standard versus a Sling Shot Assisted Bench Press Exercise
Publication -
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY
Journals -
Evaluation of Lower Limb Muscle Electromyographic Activity during 400 m Indoor Sprinting among Elite Female Athletes: A Cross-Sectional Study
Publication -
SEMG signal database for the automated upper limb rehabilitation process
Open Research DataAn automated rehabilitation device control system requires information about the patient's physiological condition. This is possible thanks to the use of biological feedback in the form of electromyography and surface signals (Surface Electromyography, SEMG).
-
A comparison of muscle activity of the dominant and non-dominant side of the body during low versus high loaded bench press exercise performed to muscular failure
Publication -
Unity-Gain Zero-Offset CMOS Buffer with Improved Feedforward Path
PublicationA voltage unity-gain zero-offset CMOS amplifier with reduced gain error and increased PSRR (power supply rejection ratio) is proposed. The amplifier uses two feed mechanisms, negative feedback and supporting positive feedforward, to achieve low deviation from unit gain over the entire input range. The circuit, designed in a standard 180-nanometer 1.8-voltage CMOS process, is compared with two known buffers of similar topology,...
-
A current-controlled FET
PublicationA novel semiconductor device, viz., Horizontally-Split-Drain Current-Controlled Field-Effect Transistor (HSDCCFET) with two control electrodes is proposed in this works. For the sake of brevity, the device can be called a CCFET. Operating principle of the proposed transistor is based on one of the galvanomagnetic phenomena, the Biot-Savart-Laplace law and a Gradual Channel Detachment Effect (GCDE). The transistor is dedicated...
-
Dedicated power supply subsystem for ultra-low noise preamplifiers
PublicationIn field of electronics there is need for low-noise amplifiers. Noise have the most important influence on analog circuits. Therefore exist necessity to develop new ultra-low noise power supplies, which can cooperate with specified amplifiers and preamplifiers. It is very common that professional power supplies are very expensive and still have disadvantages. This paper proposes simple and inexpensive solution, which fulfill specific...
-
Jaw biomechanics: Estimation of activity of muscles acting at the temporomandibular joint
PublicationThe aim of this study was to elaborate a method of estimation of activity of surface muscles acting at the temporomandibular joint of the healthy subjects by using a surface electromyography (EMG). The scope of this study involved testing chosen jaw motions (open, close, lateral deviation) and process of mastication occurring during eating food with different toughness (chewing gum, cereal and carrot) by using mixed sides, right...
-
Position Estimation in Corridors Along the Coupled Mode of Radiating Cables
PublicationRadiating cables are mostly used to provide radio communication in tunnels or corridors, but they can also be used to estimate the position of a mobile terminal along the cable. In this paper, a measuring receiver’s position was estimated by measuring the difference in the direct signal’s reception time, which was generated by a transmitter connected to one end of the radiating cable, and the delayed signal retransmitted from another...
-
Sequences of internal transcribed spacer 1, 5.8S ribosomal RNA gene and internal transcribed spacer 2 of psychrotolerant pigment-producing yeast-like fungi
Open Research DataDNA encoding ITS1-5.8S-ITS2 fragments of psychrotolerant pigment-producing yeast-like fungi named Red, Pink and Black were PCR amplified using ITS1 5' TCCGTAGGTGAACCTGCGG 3' and ITS4 5’ TCCTCCGCTTATTGATATGC 3’ primers and sequenced by Sanger method using the same primers.
-
Sequences of large subunit ribosomal RNA gene, partial sequence encoding D1/D2 domain of psychrotolerant pigment-producing yeast-like fungi
Open Research DataDNA fragments encoding D1/D2 domain of large subunit ribosomal RNA of psychrotolerant pigment-producing yeast-like fungi named Red, Pink and Black were PCR amplified using NL1 5’ GCATATCAATAAGCGGAGGAAAAG 3’ and NL4 5’ GGTCCGTGTTTCAAGACGG 3’ primers and sequenced by Sanger method using the same primers.
-
Emotion Monitor - Concept, Construction and Lessons Learned
PublicationThis paper concerns the design and physical construction of an emotion monitor stand for tracking human emotions in Human-Computer Interaction using multi-modal approach. The concept of the stand using cameras, behavioral analysis tools and a set of physiological sensors such as galvanic skin response, blood-volume pulse, temperature, breath and electromyography is presented and followed...
-
EMG and gaze based interaction with graphic interface of smart glasses application
PublicationIn this paper we investigate the effectiveness of the interaction using eye tracking and electromyography. Smart glasses requires reliable interfaces for controlling the graphic content displayed directly in front of the user's eye. Presented research is related with the eGlasses project, which is focused on the development of an open platform in the form of multisensory electronic glasses and related interaction methods. One of...
-
Data regarding a new, vector-enzymatic DNA fragment amplification-expression technology for the construction of artificial, concatemeric DNA, RNA and proteins, as well as biological effects of selected polypeptides obtained using this method
PublicationApplications of bioactive peptides and polypeptides are emerging in areas such as drug development and drug delivery systems. These compounds are bioactive, biocompatible and represent a wide range of chemical properties, enabling further adjustments of obtained biomaterials. However, delivering large quantities of peptide derivatives is still challenging. Several methods have been developed for the production of concatemers –...
-
A 0.5-V bulk-driven voltage follower / DC level shifter and its application in class AB output stage
PublicationA simple realization of a 0.5-V bulk-driven voltage follower/DC level shifter, designed in a 0.18um CMOS technology is presented in the paper. The circuit is characterized by large input and output voltage swings, and a DC voltage gain close to unity. The DC voltage shift between input and output terminals can be regulated in a certain interval around zero, by means of biasing current sinks. An application of the proposed voltage...
-
Komputerowo wspomagana klasyfikacja wybranych sygnałów elektromiografii powierzchniowej
PublicationWykorzystywanie sygnałów elektromiografii powierzchniowej (ang. Surface Electromyography, SEMG) w procesach sterowania systemami rehabilitacyjnymi stanowi obecnie standardową procedurę. Popularność SEMG wynika z nieinwazyjności metody oraz możliwości szybkiej i precyzyjnej identyfikacji funkcji mięśniowej. W przypadku osób małoletnich proces klasyfikacji sygnałów jest utrudniony ze względu na mniejsze rozmiary i wyższą dynamikę...
-
Dwa zastosowania procesorów sygnałowych w układach przetwarzania i akwizycji danych
PublicationW ciągu ostatnich kilku lat nastąpił skokowy wzrost liczby aplikacji stosujących mikrokontrolery i mikroprocesory w układach pomiarowych. Ten wzrost dotyczy także zastosowań procesorów sygnałowych, pozwalających na wstępne przetwarzanie rejestrowanych danych w czasie rzeczywistym. Możliwość wstępnego przetwarzania istotnie ogranicza liczbę przechowywanych lub przesyłanych do nadrzędnego komputera parametrów w stosunku do liczby...
-
Bulk linearized CMOS differential pair transconductor for continuous-time OTA-C filter design
PublicationIn this paper, the MOS differential pair driven simultaneously from gates and bulk terminals is described. An approximated analytical solution of the voltage to current transfer function has been found for the proposed circuit. Four possible combinations of gate and bulk connections of the input signal are presented. Basing on the configuration giving the best linearity, the operational transconductance amplifier (OTA) has been designed...
-
Ligation Mediated PCR methods, their possibilities and limitations
PublicationThe application of molecular diagnostics for bacterial strain typing or identifying bacteria at the strain level is of particular importance at present. However, among the many genotyping methods that are currently available, no single one is universally ideal. In this article, we thus review the Ligation Mediated PCR group methods as prospects from which to choose. We discuss different strategies for selecting the amplified PCR...
-
Approach for Determination of Functioning of Lower Limb Muscles
PublicationThe purpose of the study is elaboration of approach for determination of functioning of chosen muscles that are essential for gait performance (Tibialis Anterior, Rectus Femoris, Gastrocnemius Medialis, Biceps Femoris). The scope of the study involves the analysis of the symmetric planar motion performing in the sagittal plane of the body by applying planar multibody model and electromyography signals (EMG) registered over normal...
-
Low cost set-up for supercapacitors parameters evaluation
PublicationWe propose a use of a power amplifier in the circuit of voltage to current converter (current driver) for supercapacitor charging/discharging in controlled conditions. The current driver is controlled by DAC output of DAQ board and voltage of DUT is measured and a control loop is realized by software. In the circuit the DC current method of evaluation of capacitance and equivalent series...
-
Towards hand grip force assessment by using EMG estimators
PublicationThe purpose of this study was to propose a method to assess individual regression (calibration) curves to establish a relationship between an isometric grip force and surface electromyography (EMG) estimator. In this study 18 healthy volunteers (12 male (23.0 ± 2.0 years) and 6 female (23.2 ± 0.7 years)) had been examined. Ten EMG estimators (mean absolute value, root mean square, entropy, energy, turns per second, mean of zero...
-
Rezystor aktywny CMOS oraz jego zastosowanie do budowy wzmacniacza transkonduktancyjnego.
PublicationRezystory aktywne są szeroko stosowane w układach analogowych. Jednym z bardzo ważnych zastosowań jest ich użycie jako elementu linearyzującego stałoprądowe charakterystyki przejściowe wzmacniacza różnicowego wykonanego w postaci pary tranzystorów MOS. W niniejszym artykule przedstawiono w pełni różnicowy, aktywny rezystor MOS. Składa się on z dwóch tranzystorów MOS oraz dwóch nieuziemionych źródeł napięciowych. Jako wykorzystanie...
-
Preliminary results from HEDGEHOG REXUS project – A sounding rocket experiment on accelerations, vibrations and heat flow
PublicationDuring flight, a sounding rocket is subject to a unique environment - severe vibrations and substantial heat flux. In order to design payloads, precise measurement of these conditions is required. This paper presents preliminary results from HEDGEHOG REXUS Project, whose scientific goal was to characterise the thermal and dynamic environment of REXUS sounding rockets. For this purpose, two new sensors have been designed - mechanical...
-
Selection of physiological parameters for optoelectronic system supporting behavioral therapy of autistic children
PublicationIn this article the procedure of selection of physiological parameters for optoelectronic system supporting behavioral therapy of autistic children is proposed. Authors designed and conducted an experiment in which a group of 30 health volunteers (16 females and 14 males) were examined. Under controlled conditions people were exposed to a stressful situation caused by the picture or sound (1kHz constant sound, which was gradually...
-
System supporting behavioral therapy for children with autism
PublicationIn this paper, a system supporting behavioral therapy for autistic children is presented. The system consists of sensors network, base station and a brooch indicating person's emotional states. The system can be used to measure values of physiological parameters that are associated with changes in the emotional state. In the future, it can be useful to inform the autistic child and the therapist about the emotional state of the...
-
Unsupervised Learning for Biomechanical Data Using Self-organising Maps, an Approach for Temporomandibular Joint Analysis
PublicationWe proposed to apply a specific machine learning technique called Self-Organising Maps (SOM) to identify similarities in the performance of muscles around human temporomandibular joint (TMJ). The performance was assessed by measuring muscle activation with the use of surface electromyography (sEMG). SOM algorithm used in the study was able to find clusters of data in sEMG test results. The SOM analysis was based on processed sEMG...
-
Multiple output second-generation current conveyor utilizing high frequency output stage
PublicationIn this paper a multiple output second-generation current conveyor (MOCCII) is presented. The main advantage of the proposed general circuit architecture over a typical structure, well known in the literature, is the use of a high passband multiple output current mplifier block instead of cascaded current mirrors. It gives similar frequency responses for all the outputs of the current conveyor and also maintains simplicity of the...
-
A 1-nS 1-V Sub-1-µW Linear CMOS OTA with Rail-to-Rail Input for Hz-Band Sensory Interfaces
PublicationThe paper presents an operational transconductance amplifier (OTA) with low transconductance (0.62–6.28 nS) and low power consumption (28–270 nW) for the low-frequency analog front-ends in biomedical sensor interfaces. The proposed OTA implements an innovative, highly linear voltage-to-current converter based on the channel-length-modulation effect, which can be rail-to-rail driven. At 1-V supply and 1-Vpp asymmetrical input driving,...