Filtry
wszystkich: 1217
wybranych: 564
Wyniki wyszukiwania dla: MENISCUS- BONE ANGLE
-
The Effects of Slaughter Age and Sex on Carcass Traits, Meat Quality, and Leg Bone Characteristics of Farmed Common Pheasants (Phasianus colchicus L.)
Publikacja -
Human Umbilical Vein Endothelial Cells (HUVECs) Co-Culture with Osteogenic Cells: From Molecular Communication to Engineering Prevascularised Bone Grafts
Publikacja -
The changes of antioxidant defense system caused by quercetin administration do not lead to DNA damage and apoptosis in the spleen and bone marrow cells of rats
Publikacja -
Monocyte Chemoattractant Protein-Induced Protein 1 (MCPIP1) Enhances Angiogenic and Cardiomyogenic Potential of Murine Bone Marrow-Derived Mesenchymal Stem Cells
Publikacja -
Proximal fibular osteotomy as a treatment for degenerative meniscal extrusion
PublikacjaMeniscal extrusion treatment is a key focus area for research and clinical study of degenerative knee pathology. The contact forces between the meniscus and the bones cause external displacements of the meniscus that are resisted by the circumferential fibres. The main risk factors for the excessive deformation of the meniscus are meniscal root tears, disruption of the circumferential fibres, knee malalignment and high body mass...
-
Improving osteoblasts cells proliferation via femtosecond laser surface modification of 3D-printed poly-ε-caprolactone scaffolds for bone tissue engineering applications
Publikacja -
Evidence for widespread occurrence of copper in Late Neolithic Poland? A deposit of Funnel Beaker Culture bone products at site 2 in Osłonki (Kuyavia, central Poland)
Publikacja -
Protective effect of Aronia melanocarpa polyphenols against cadmium-induced disorders in bone metabolism: A study in a rat model of lifetime human exposure to this heavy metal
Publikacja -
Protective impact of extract from Aronia melanocarpa berries against low-level exposure to cadmium-induced lipid peroxidation in the bone tissue: a study in a rat model
Publikacja -
Repair Augmentation of Unstable, Complete Vertical Meniscal Tears With Bone Marrow Venting Procedure: A Prospective, Randomized, Double-Blind, Parallel-Group, Placebo-Controlled Study
Publikacja -
Differences in Expression of Genes Involved in Bone Development and Morphogenesis in the Walls of Internal Thoracic Artery and Saphenous Vein Conduits May Provide Markers Useful for Evaluation Graft Patency
Publikacja -
Comparison of Bone Injection Gun and Jamshidi intraosseous access devices by paramedics with and without chemical-biological-radiological-nuclear personal protective equipment: a randomized, crossover, manikin trial
Publikacja -
Author Reply to “Regarding ‘Repair Augmentation of Unstable, Complete Vertical Meniscal Tears With Bone Marrow Venting Procedure: A Prospective, Randomized, Double-Blind, Parallel-Group, Placebo-Controlled Study’”
Publikacja -
Bio and slide biobearings, their lubrication by non-newtonian fluids and application in non-conventional systems. Vol. 1, Principles of human joint lubrication with non-newtonian liquids for deformable bone and cartilage in magnetic field
PublikacjaW monografii przedstawiono zasady smarowania stawów człowieka o odkształcalnych chrząstkach i powierzchniach kostnych w polach indukcji magnetycznej. Uwzględnione zostały nienewtonowskie, lepkosprężyste właściwości cieczy synowialnych jako czynnika smarującego. Monografia prezentuje rozkłady wartości ciśnienia i nośności stawów człowieka w warunkach niestacjonarnego smarowania dla drgań o różnych amplitudach i częstotliwościach...
-
Chosen aspects of skeletal system modeling: Numerical solid and shell models of femur part
PublikacjaThe purpose of this paper is to present a new method of femur part modeling by using the finite element method. This method treats a femur part as a system composed of cortical and trabecular bone. For the purpose of determining a proper shape of femur part model there were created three models: a) the first one describes a femur part as a solid structure; b) the second one describes a femur part as a connection of cortical bone...
-
Debonding of coin-shaped osseointegrated implants: Coupling of experimental and numerical approaches
PublikacjaWhile cementless implants are now widely used clinically, implant debonding still occur and is difficult to anticipate. Assessing the biomechanical strength of the bone–implant interface can help improving the understanding of osseointegration phenomena and thus preventing surgical failures. A dedicated and standardized implant model was considered. The samples were tested using a mode III cleavage device to assess the mechanical...
-
Możliwości modelowania rozkładu naprężeń i odkształceń w endoprotezie stawu biodrowego w układzie implant - kość z uwzględnieniem własności materiałowych = Possibility of stress and strain modelling in total hip replacement in implant-bone system including material properties
PublikacjaW pracy przedstawiono możliwości wykorzystania numerycznych technik komputerowych do modelowania rozkładu naprężeń i odkształceń w endoprotezie stawu biodrowego w układzie implant-kość z uwzględnieniem własności materiałowych elementów endoprotezy. Przedstawiono komputerowe modele służące do analizy naprężeń i odkształceń w endoprotezie wykonane przy wykorzystaniu metody elementów skończonych. Metody modelowania naprężeń i odkształceń...
-
A new finite element with variable Young's modulus
PublikacjaThe Finite Element Method (FEM) is a numerical technique that is well-established in the field of engineering. However, in biological sciences, it is justtaking its first steps. Bone tissue is an example of biological material which isexposed to high loads in its natural environment. Practically every movementof the body results in changing stress levels in the bone. Nature copes with thisvery well but when human intervention is...
-
Method of Skeletal System Modelling
PublikacjaAn original method of skeletal system modelling is presented in detail. Using DICOM images obtained from CT and PET tests, shell models of nine bones were created (humerus, radius, ulna, scapula, clavicle, femur, tibia, fibula, pelvis). Two methods of bone behaviour are also proposed, the first method treating the bone as a solid structure and the second method treating the bone as a complex porous structure. The behaviour of model...
-
High-dose chemotherapy with autologous stem cell transplantation is an effective treatment of primary refractory Hodgkin's disease. Retrospective study of the Polish Lymphoma Research Group
Publikacja -
Radioimmunotherapy with 90Y-ibritumomab tiuxetan is a safe and efficient treatment for patients with B-cell lymphoma relapsed after auto-SCT: an analysis of the international RIT-Network
Publikacja -
Rozmyty system wnioskowania do oszacowania maksymalnego naprężenia kontaktowego na powierzchni panewki endoprotezy stawu biodrowego w zależności od kąta Wiberga i masy ciała pacjenta = Fuzzy reasoning system for maximal contact stress estimation on acetabular surface in hip endoprosthesis based on Wiberg angle and weight of patient
PublikacjaPrzedstawiono możliwość wykorzystania systemu rozmytego, który wykorzystując rozumowanie przybliżone określa maksymalne naprężenie kontaktowe na powierzchni przenoszenia obciążeń panewki endoprotezy stawu biodrowego, biorąc pod uwagę kąt Wiberga oraz masę ciała pacjenta.
-
Materiały stosowane do wytwarzania implantów kości
PublikacjaMateriały stosowane do wytwarzania implantów kostnych muszą być biokompatybilne, nietoksyczne, bioaktywne oraz wykazywać odpowiednie właściwości mechaniczne, takie jak wytrzymałość na ściskanie, na zginanie oraz sztywność i twardość. Gama stosowanych materiałów jest bardzo szeroka, obejmuje metale, polimery, ceramikę oraz ich kompozyty. Każdy z tych materiałów ma swoje mocne i słabe strony. Praca stanowi przegląd materiałów stosowanych...
-
Structural and Material Determinants Influencing the Behavior of Porous Ti and Its Alloys Made by Additive Manufacturing Techniques for Biomedical Applications
PublikacjaOne of the biggest challenges in tissue engineering is the manufacturing of porous structures that are customized in size and shape and that mimic natural bone structure. Additive manufacturing is known as a sufficient method to produce 3D porous structures used as bone substitutes in large segmental bone defects. The literature indicates that the mechanical and biological properties of scaffolds highly depend on geometrical features...
-
Degradable poly(ester-ether) urethanes of improved surface calcium deposition developed as novel biomaterials
PublikacjaBones, which are considered as hard tissues, work as scaffold for human body. They provide physical support for muscles and protect intestinal organs. Percentage of hard tissues in human body depends on age, weight, and gender. Human skeleton consists of 206 connected bones. Therefore, it is natural that the hard-tissue damage such as fractures, osteoporosis, and congenital lack of bone may appear. The innovative way of bone healing...
-
Modyfikacja cementu kostnego w celu uzyskania długotrwałej ochrony antybakteryjnej
PublikacjaNiniejsza rozprawa doktorska stanowi przewodnik po jednotematycznym cyklu publikacji, dotyczącym modyfikacji akrylowego cementu kostnego celem uzyskania długotrwałej i efektywnej ochrony antybakteryjnej. W ramach niego przeprowadzono badania eksperymentalne polegające na opracowaniu technologii wytwarzania modyfikowanego cementu kostnego oraz procedury medycznej jego stosowania. Cement kostny był modyfikowany przez zastosowanie...
-
Determinants of the primary stability of cementless acetabular cup implants: A 3D finite element study
PublikacjaPrimary stability of cementless implants is crucial for the surgical success and long–term stability. However, primary stability is difficult to quantify in vivo and the biomechanical phenomena occurring during the press–fit insertion of an acetabular cup (AC) implant are still poorly understood. The aim of this study is to investigate the influence of the cortical and trabecular bone Young's moduli Ec and Et, the interference...
-
Modeling the debonding process of osseointegrated implants due to coupled adhesion and friction
PublikacjaCementless implants have become widely used for total hip replacement surgery. The long-term stability of these implants is achieved by bone growing around and into the rough surface of the implant, a process called osseointegration. However, debonding of the bone–implant interface can still occur due to aseptic implant loosening and insufficient osseointegration, which may have dramatic consequences. The aim of this work is to...
-
Polyurethane Composite Scaffolds Modified with the Mixture of Gelatin and Hydroxyapatite Characterized by Improved Calcium Deposition
PublikacjaThe skeleton is a crucial element of the motion system in the human body, whose main function is to support and protect the soft tissues. Furthermore, the elements of the skeleton act as a storage place for minerals and participate in the production of red blood cells. The bone tissue includes the craniomaxillofacial bones, ribs, and spine. There are abundant reports in the literature indicating that the amount of treatments related...
-
Variable Order Differential Models of Bone Remodelling * *This work was supported by FCT, through IDMEC, under LAETA, projects UID/EMS/50022/2013, BoneSys, joint Polish-Portuguese project Modelling and controlling cancer evolution using fractional calculus, PERSEIDS (PTDC/EMS-SIS/0642/2014) and IF/00653/2012
Publikacja -
Mesh dependence study for numerical assessment of hydrodynamic characteristics of windsurfing fin
PublikacjaThe presented research aims to assess the drag coefficient and lift coefficient versus angle of attack curves for windsurfing fin. Special attention in the research was being paid to the evaluation of the stall angle value. The angle of incidence for which the stall occurs was searched, and the sensitivity of the solution for the mesh resolution was studied. The mesh resolution sensitivity analysis was done by systematically decreasing...
-
Wpływ kąta pochylenia koła na opór toczenia opon samochodowych
PublikacjaW pracy przedstawiono wpływ kąta pochylenia koła na opór toczenia opon do samochodów osobowych. Pomiary oporu toczenia kół toczących się z kątem pochylenia od -6º do +3º wykonano na bębnowej maszynie bieżnej metodą momentową. Wyniki pomiarów przedstawiono w formie zależności współczynnika oporu toczenia oraz przyrostu współczynnika oporu toczenia w funkcji kąta pochylenia badanego koła.
-
Properties of New Composite Materials Based on Hydroxyapatite Ceramic and Cross-Linked Gelatin for Biomedical Applications
PublikacjaThe main aim of the research was to develop a new biocompatible and injectable composite with the potential for application as a bone-to-implant bonding material or as a bone substitute. A composite based on hydroxyapatite, gelatin, and two various types of commercially available transglutaminase (TgBDF/TgSNF), as a cross-linking agent, was proposed. To evaluate the impacts of composite content and processing parameters on various...
-
Comparative analysis of balancing of V6 engines with common- and split-pin crankshafts
PublikacjaAn analysis of balancing of V6 engines equipped with split-pin crankshafts with any cylinder bank angle based on the mathematical relations derived in the paper was carried out. A comparison of the quality of their balancing with engines equipped with common-pin crankshafts was also carried out. The bank angle ranges beneficial for balancing of moments of inertia forces in reciprocating motion were determined. A mathematical relation...
-
Analytical Steady-State Model of the Pipeline Flow Process
PublikacjaThe paper addresses the issue of modeling the flow process in transmission pipelines. A base model used for numerical simulation is introduced. Under certain assumptions concerning steady state analysis, the differential equations describing the process are solved analytically for two cases: zero and nonzero inclination angle α. These equations describe a constant flow rate and a corresponding distribution of the pressure along...
-
Wettability of Horizontal Stainless Steel Tube by Nanofluid Droplets
PublikacjaThe goal of the present work was the experimental determination of the contact angle of three nanofluids, i.e. water-Al2O3, water-Cu and water-TiO2 on horizontal stainless steel tube of 1.6 mm OD. Of particular interest was the effect of nanoparticle concentration (0.01%, 0.1%, and 1% by weight) on droplet contact angle.
-
Wettability of Horizontal Stainless Steel Tube by Nanofluid Droplets
PublikacjaThe goal of the present work was the experimental determination of the contact angle of three nanofluids, i.e. water-Al2O3, water-Cu and water-TiO2 on horizontal stainless steel tube of 1.6 mm OD. Of particular interest was the effect of nanoparticle concentration (0.01%, 0.1%, and 1% by weight) on droplet contact angle.
-
Titania Nanofiber Scaffolds with Enhanced Biointegration Activity—Preliminary In Vitro Studies
PublikacjaThe increasing need for novel bone replacement materials has been driving numerous studies on modifying their surface to stimulate osteogenic cells expansion and to accelerate bone tissue regeneration. The goal of the presented study was to optimize the production of titania-based bioactive materials with high porosity and defined nanostructure, which supports the cell viability and growth. We have chosen to our experiments TiO2...
-
Numerical Model of Femur Part
PublikacjaThe aim of the study is to create a new more accurate method of femur part modelling by using the finite element method. According to this new method, a femur part is treated as a complex structure composed of trabecular bone (internal part) and cortical bone (external part). The internal part is modelled as a scaffold, thus the external part is modelled as a coat (i.e. covering). Applying the programme ABAQUS, there were created...
-
Experimental study on the effect of selected sterilization methods on mechanical properties of polylactide FFF specimens
PublikacjaPurpose: Biodegradable polymers are widely used in personalized medical devices or scaffolds for tissue engineering. The manufacturing process should be finished with sterilization procedure. However, it is not clear how the different sterilization methods have an impact on the mechanical strength of the three-dimensional (3D)-printed parts, such as bone models or personalized mechanical devices. This paper aims to present the...
-
Smart Healthy Age-Friendly Environments (SHAFE) Bridging Innovation to Health Promotion and Health Service Provision
Publikacja -
Medially positioned plate in first metatarsophalangeal joint arthrodesis
PublikacjaObjective The purpose of this study was to biomechanically compare the stability of first metatarsophalangeal (MTP1) joint arthrodesis with dorsally and medially positioned plates. Methods A physical model of the MTP1 joint consists of printed synthetic bones, a titanium locking plate and screws. In the experiments, samples with dorsally and medially positioned plates were subjected to loading of ground load character in a universal...
-
Evaluation of the Cathodic Electrodeposition Effectiveness of the Hydroxyapatite Layer Used in Surface Modification of Ti6Al4V-Based Biomaterials
PublikacjaThe important issue associated with the design and the fabrication of the titanium and titanium alloy implants is the increase of their biointegration with bone tissue. In the presented paper, the research results concerning the conditions used in the cathodic deposition of hydroxyapatite on the surface Ti6Al4V substrates primarily modified by the production of TiO2 nanoporous coatings, TiO2 nanofibers, and titanate coatings, are...
-
Analysis of balancing of four stroke V6 engines
PublikacjaAnalysis of balance of V6 engines with a common-pin crankshaft depending on a cylinder bank angle and the crank radius to connecting rod length ratios , based on the relations derived, is presented in the paper. The bank angles providing the lowest moment of inertia forces in reciprocating motion, for selected values, were determined. The position of the plane of the main counterweights in order to maximum balance of the moment...
-
Leaf wettability and plant surface water storage for common wetland species of the Biebrza peatlands (northeast Poland)
PublikacjaWetlands play a crucial role in buffering the effects of climate change. At the same time, they are one of the most endangered ecosystems on the globe. The knowledge of the water cycle and energy exchange is crucial for the practical preservation and exploiting their capabilities. Leaf wettability is an important parameter characterising the plant's ability to retain water on its surface, and is linked to the ecosystems' hydrological...
-
Natural convective heat transfer from isothermalconic
PublikacjaTheoretical considerations on convective heat transfer from isothermal upward conicalsurfaces have been presented. The physical model of this phenomenon consists of an isothermalcone of inclination angle (φ) between the cone generating line (X) and the radius (R) of the cone base. The angle is a parameter of conical surface which varied from (φ = 0−circular horizontal plate) to (φ = π/2—vertical cylinder) . Onthe basis of Navier–Stokes...
-
Position and Orientation Estimation in Radio Network With Groups of Locally Synchronized Nodes
PublikacjaThis article presents a positioning system with groups of locally synchronized nodes. A mobile object is equipped with a group of several synchronized receivers that are able to measure the difference in the time of arrival of signals from reference transmitters. The reference transmitters are synchronized only in local groups, with no global synchronization between groups. It is assumed that the synchronous operation of transmitters...
-
Influence of water and mineral oil on the leaks in satellite motor commutation unit clearances
PublikacjaThe article describes the flow rates of mineral oil and water flowing, as working media, through the commutation unit of a hydraulic satellite motor. It is demonstrated that geometrical dimensions of commutation unit clearances change as a function of the machine shaft rotation angle. Methods for measuring the rate of this flow and the pressure in the working chamber are presented. The results of pressure measurements in the working...
-
Linear Micropolar Elasticity Analysis of Stresses in Bones Under Static Loads
PublikacjaWe discuss the finite element modeling of porous materials such as bones using the linear micropolar elasticity. In order to solve static boundary-value problems, we developed new finite elements, which capture the micropolar behavior of the material. Developed elements were implemented in the commercial software ABAQUS. The modeling of a femur bone with and without implant under various stages of healing is discussed in details
-
Stability Enhancement of Grid-Connected Wind Power Generation System Using PSS, SFCL and STATCOM
PublikacjaThe stability related issues may occur in a power system due to disturbances in generating or loading conditions, especially in the presence of distributed generation (DG) based on renewable energy resources (RERs). This paper proposes a novel strategy for the stability enhancement of a wind power generation system (WPGS) by using a combination of three devices, namely, a power system stabilizer (PSS), resistive superconductor...