Filtry
wszystkich: 343
wybranych: 292
Wyniki wyszukiwania dla: OPTICAL COHERENCE TOMOGRAPHY, MAGNETIC RESONANCE IMAGING
-
Optical coherence tomography and magnetic resonance imaging visual pathway evaluation in Wolfram syndrome
Publikacja -
Latent fingerprint imaging by spectroscopic optical coherence tomography
PublikacjaOptical coherence tomography (OCT) is a non-contact and non-invasive optical method for evaluating semitransparent and scattering objects. Its unique features, such as non-destructive 3D measurements of tested objects with a fast scanning rate, make this technique interesting for latent fingerprint reading, which is the subject of this paper. So far, OCT has not found widespread use for reading fingerprints directly from surfaces...
-
Optical method for verification of homogeneity of phantoms for calibration of magnetic resonance
PublikacjaThe primary purpose of this study was to develop a laboratory photonic set-up for characterisation of homogeneity of gel phantoms for calibration of magnetic resonance. In this system, optical coherence tomography allows the detection of micro- and macroscopic heterogeneities of a structure. The set-up was used to perform measurements of agar and agar-carrageenan gels, which are the basis for more complex phantoms for magnetic...
-
1D portable optical coherence tomography system
Publikacja—Imaging methods are an expanding branch of technology, which involves data acquisition and analysis of images for research and diagnostics. This paper has been devoted to the description of the optical design for a one-dimensional, portable optical coherence tomography (OCT) system. The Mach-Zehnder interferometer has been designed in the presented study. The description of the construction and applied hardware solutions have...
-
Polarization-sensitive optical coherence tomography for ceramic materials inspection
PublikacjaCeramics production is looking for a fast, reliable and non-destructive method that can be implemented on site for defect detection and analysis. In this paper we present polarization-sensitive optical coherence tomography (PS-OCT) as a method for defect inspection. Proposed extensions to standard OCT provide additional information for complete characterization of tested object. We compare OCT and microscope imaging that can easily...
-
Nanoparticles displacement analysis using optical coherence tomography
PublikacjaOptical coherence tomography (OCT) is a versatile optical method for cross-sectional and 3D imaging of biological and non-biological objects. Here we are going to present the application of polarization sensitive spectroscopic OCT system (PS-SOCT) for quantitative measurements of materials containing nanoparticles. The PS-SOCT combines the polarization sensitive analysis with time-frequency analysis. In this contribution the benefits...
-
Advanced polarization sensitive analysis in optical coherence tomography
PublikacjaThe optical coherence tomography (OCT) is an optical imaging method, which is widely applied in variety applications. This technology is used to cross-sectional or surface imaging with high resolution in non-contact and non-destructive way. OCT is very useful in medical applications like ophthalmology, dermatology or dentistry, as well as beyond biomedical fields like stress mapping in polymers or protective coatings defects detection....
-
Efficient signal processing in spectroscopic optical coherence tomography
PublikacjaSpectroscopic optical coherence tomography (SOCT) is an extension of a standard OCT technique, which allows to obtain depth-resolved, spectroscopic information on the examined sample. It can be used as a source of additional contrast in OCT images e.g. by encoding certain features of the light spectrum into the hue of the image pixels. However, SOCT require computation of time-frequency distributions of each OCT A-scan, what is...
-
Advanced Monte Carlo simulator of the polarization-sensitive optical coherence tomography systems
PublikacjaSimulations of the optical coherence tomography (OCT) systems using the Monte Carlo method is a widely explored research area. However, there are several difficulties that need to be overcome in order to properly model the OCT imaging with the Monte Carlo algorithm. First of all, the temporal and the spatial coherence of the scattered light need to be considered, since OCT is based on the interference phenomenon. For the same reason,...
-
Nanodiamonds Doped with Manganese for Applications in Magnetic Resonance Imaging
PublikacjaNanodiamonds (NDs) are emerging with great potential in biomedical applications like biomarking through fluorescence and magnetic resonance imaging (MRI), targeted drug delivery, and cancer therapy. The magnetic and optical properties of NDs could be tuned by selective doping. Therefore, we report multifunctional manganese-incorporated NDs (Mn-NDs) fabricated by Mn ion implantation. The fluorescent properties of Mn-NDs were tuned...
-
Molecular Imaging and Nanotechnology—Emerging Tools in Diagnostics and Therapy
PublikacjaPersonalized medicine is emerging as a new goal in the diagnosis and treatment of diseases. This approach aims to establish differences between patients suffering from the same disease, which allows to choose the most effective treatment. Molecular imaging (MI) enables advanced insight into molecule interactions and disease pathology, improving the process of diagnosis and therapy and, for that reason, plays a crucial role in personalized...
-
Simulating coherent light propagation in a random scattering materials using the perturbation expansion
PublikacjaMultiple scattering of a coherent light plays important role in the optical metrology. Probably the most important phenomenon caused by multiple scattering are the speckle patterns present in every optical imaging method based on coherent or partially coherent light illumination. In many cases the speckle patterns are considered as an undesired noise. However, they were found useful in various subsurface imaging methods such as...
-
Computational Methods for Liver Vessel Segmentation in Medical Imaging: A Review
PublikacjaThe segmentation of liver blood vessels is of major importance as it is essential for formulating diagnoses, planning and delivering treatments, as well as evaluating the results of clinical procedures. Different imaging techniques are available for application in clinical practice, so the segmentation methods should take into account the characteristics of the imaging technique. Based on the literature, this review paper presents...
-
Special techniques and future perspectives: Simultaneous macro- and micro-electrode recordings
PublikacjaThere are many approaches to studying the inner workings of the brain and its highly interconnected circuits. One can look at the global activity in different brain structures using non-invasive technologies like positron emission tomography (PET) or functional magnetic resonance imaging (fMRI), which measure physiological changes, e.g. in the glucose uptake or blood flow. These can be very effectively used to localize active patches...
-
Obrazowanie parametryczne w badaniach mózgu metodami MRI/PET
PublikacjaCelem tej monografii jest przedstawienie technik obrazowania metodami tomografii rezonansu magnetycznego (MRI - Magnetic Resonance Imaging) i pozytonowej tomografii emisyjnej (PET - Positron Emission Tomography) w kontekście badań dynamicznych mózgu, szczególnie w zakresie syntezy obrazów parametrycznych opisujących jakościowo lub ilościowo przepływ mózgowy. Obrazowanie parametryczne określa technikę syntezy obrazów na podstawie...
-
New method to monitor changes in the subarachnoid width and pial artery pulsation for physiological and clinical research
PublikacjaThere are several medical conditions associated with brain oedema such as traumatic brain injury, intoxication or tumors. Brain edema and related brain parenchyma expansion may lead to compression and subsequent injury of several brain structures. So far, the only method enabling detection and monitoring of the progress a cerebral oedema in a patient, has been monitoring of intracranial pressure (ICP) with a pressure probe inserted...
-
Gold nanoparticles evaluation using functional optical coherence tomography
PublikacjaThe main object of this research was to assess the ability to characterize the gold nanoparticles using optical modalities like optical coherence tomography. Since the nanoparticles, especially gold one, have been very attractive for medical diagnosis and treatment the amount of research activities have been growing rapidly. The nanoparticles designed for different applications like contrast agents or drugs delivery change the...
-
Detection of petroleum products using optical coherence tomography
PublikacjaIn this work, we present a novel method developed for the analysis of the properties of thin layers for detecting petroleum products on a water surface using a commercially available optical coherence tomography (OCT) system. The spectral density analysis of the signal from a spectroscopic OCT (S-OCT) enables us to perform the precision calculation of the thin layer thickness and other properties like homogeneity, and dispersion,...
-
Microcrystalline diamond film evaluation by spectroscopic optical coherence tomography
PublikacjaThis study has focused on the microcrystalline diamond film (MCD) thickness evaluation. For this purpose, optical coherence tomography (OCT) enhanced by spectroscopic analysis has been used as a method of choice. The average thickness of the tested layer was about 1.5 µm, which is below the standard 2-point OCT resolution. In this case, the usefulness of the spectroscopic analysis was confirmed for the evaluation of the thickness...
-
Optical Coherence Tomography for nanoparticles quantitative characterization
PublikacjaThe unique features of nanocomposite materials depend on the type and size of nanoparticles, as well as their placement in the composite matrices. Therefore the nanocomposites manufacturing process requires inline control over certain parameters of nanoparticles such as dispersion and concentration. Keeping track of nanoparticles parameters inside a matrix is currently a difficult task due to lack of a fast, reliable and cost effective...
-
Detection system for optical coherence tomography: Czerny-Turner spectrometer
PublikacjaResearch methods based on spectral analysis have powerful impact on development in many field of science. Signal spectrum can be a source of useful and important data. It enables to obtain information about physical and chemical properties of tested materials. This paper has been devoted to describe optical design for high resolution spectrometer, which is significant element of optical coherence tomography (OCT) systems. Designed...
-
Parallel multithread computing for spectroscopic analysis in optical coherence tomography
PublikacjaSpectroscopic Optical Coherence Tomography (SOCT) is an extension of Optical Coherence Tomography (OCT). It allows gathering spectroscopic information from individual scattering points inside the sample. It is based on time-frequency analysis of interferometric signals. Such analysis requires calculating hundreds of Fourier transforms while performing a single A-scan. Additionally, further processing of acquired spectroscopic information...
-
Novel approach to modeling spectral-domain optical coherence tomography with Monte Carlo method
PublikacjaNumerical modeling Optical Coherence Tomography (OCT) systems is needed for optical setup optimization, development of new signal processing methods and assessment of impact of different physical phenomena inside the sample on OCT signal. The Monte Carlo method has been often used for modeling Optical Coherence Tomography, as it is a well established tool for simulating light propagation in scattering media. However, in this method...
-
The Optical Coherence Tomography and Raman Spectroscopy for Sensing of the Bone Demineralization Process
PublikacjaThe presented research was intended to seek new optical methods to investigate the demineralization process of bones. Optical examination of the bone condition could facilitate clinical trials and improve the safety of patients. The authors used a set of complementary methods: polarization-sensitive optical coherence tomography (PS-OCT) and Raman spectroscopy. Chicken bone samples were used in this research. To stimulate in laboratory...
-
Time-frequency analysis in optical coherence tomography for technical objects examination
PublikacjaOptical coherence tomography (OCT) is one of the most advanced optical measurement techniques for complex structure visualization. The advantages of OCT have been used for surface and subsurface defect detection in composite materials, polymers, ceramics, non-metallic protective coatings, and many more. Our research activity has been focused on timefrequency spectroscopic analysis in OCT. It is based on time resolved spectral analysis...
-
Comment on "Quantitative comparison of analysis methods for spectroscopic optical coherence tomography"
PublikacjaIn a recent paper by Bosschaart et al. [Biomed. Opt. Express 4, 2570 (2013)] various algorithms of time-frequency signal analysis have been tested for their performance in blood analysis with spectroscopic optical coherence tomography sOCT). The measurement of hemoglobin concentration and oxygen saturation based on blood absorption spectra have been considered. Short time Fourier transform (STFT) was found as the best method for...
-
Spectroscopic Optical Coherence Tomography for Thin Layer and Foil Measurements
PublikacjaThe main goal of this research was to assess if it is possible to evaluate the thickness of thin layers (both thin films on the surface and thin layers below the surface of the tested object) and foils using optical coherence tomography (OCT) for thickness assessment under the resolution of the standard commercially available OCT measurement system. In the proposed solution, light backscattered from the evaluated thin layer has...
-
Nanodiamond phantoms mimicking human liver: perspective to calibration of T1 relaxation time in magnetic resonance imaging
PublikacjaPhantoms of biological tissues are materials that mimic the properties of real tissues. This study shows the development of phantoms with nanodiamond particles for calibration of T1 relaxation time in magnetic resonance imaging. Magnetic resonance imaging (MRI) is a commonly used and non-invasive method of detecting pathological changes inside the human body. Nevertheless, before a new MRI device is approved for use, it is necessary...
-
Dispersion compensation in optical coherence tomography
PublikacjaDyspersja wprowadzana przez system optycznej tomografii koherentnej (OCT) oraz badane obiekty powoduje zniekształcenia fazowe w zależności od długości fali widma promieniowania zastosowanego źródła optycznego. powoduje to rozmycie obrazów otrzymanych przekrojów badanych materiałów pogarszając właściwości metrologiczne systemu OCT. W artykule przedstawiono metody kompensacji dyspersji w systemie OCT oraz przedyskutowano ich właściwości.
-
Measurement of selected characteristics of low-coherence optical signal sources for optical coherence tomography
Publikacja -
Measurement of selected characteristics of low-coherence optical signal sources for optical coherence tomography
PublikacjaOCT to nowa metoda badania wewnętrznych struktur materiałów. Wśród wielu technik detekcji sygnału optycznego wykorzystywanych w OCT najpopularniejszą i najbardziej obiecującą jest OLCR (Opticla-Low Coherence Reflectomerty - reflektometria niskokoherentna). OLCR wykorzystuje szerokopasmowe źródła, których parametry, jak np.: charakterystyka widmowa, charakterystyka szumowa, determinują właściwości metrologiczne systemu OCT. W artykule...
-
Polarization state analysis in optical coherence tomography
PublikacjaW artykule zaprezentowano metody analizy stanu polaryzacji światła w systemach optycznej tomografii kohererentnej. Przedstawiono różne konfiguracje systemu PS-OCT wraz z ich parametrami oraz właściwościami. Omówiono zasadę pomiaru stanu polaryzacji ściatła przy użyciu systemu PS-OCT oraz przeprowadzono dyskusję nad przydatnością metody do badania struktury materiałów silnie rozpraszających promieniowanie.
-
Polarization sensitive optical coherence tomography system
PublikacjaW pracy pokazano system OCT czuły na stan polaryzacji do pomiaru właściwości dwójłomnych wybranych ośrodków rozpraszających światło. W systemie zastosowano detekcję zrównoważoną. Pokazano wstępne wyniki pomiarowe.
-
Synthesized light source for optical coherence tomography
PublikacjaW artykule omówiono wpływ parametrów źródła promieniowania optycznego na właściwości systemu OCT. Szczególną uwagę zwrócono na źródła syntezowane. Omówiono charakterystykę źródła zbudowanego z dwóch różnych diod SLD. Przedstawiono wyniki pomiarów, które wskazują na możliwości znacznego polepszenia czułości i rozdzielczości systemu OCT wykorzystującego takie źródło.
-
Reactivation of seizure‐related changes to interictal spike shape and synchrony during postseizure sleep in patients
PublikacjaOBJECTIVE: Local field potentials (LFPs) arise from synchronous activation of millions of neurons, producing seemingly consistent waveform shapes and relative synchrony across electrodes. Interictal spikes (IISs) are LFPs associated with epilepsy that are commonly used to guide surgical resection. Recently, changes in neuronal firing patterns observed in the minutes preceding seizure onset were found to be reactivated during postseizure...
-
Polarization sensitive optical coherence tomography with spectroscopic analysis
PublikacjaOptyczna tomografia koherentna (OCT) jest nieinwazyjną, nieniszczącą i bezkontaktową metodą obrazowania wewnętrznej struktury obiektów i materiałów rozpraszających. Dodatkowo w połączeniu z analizą stanu polaryzacji metoda ta umożliwia badanie lokalnych zmian optycznej anizotropii występującej w badanym obiekcie. W artykule przedstawiono zalety oraz ograniczenia metody oraz przedstawiono propozycję rozszerzenia analizy o badanie...
-
Nano-particle doped hydroxyapatite material evaluation using Spectroscopic Polarization Sensitive Optical Coherence Tomography
PublikacjaBio-ceramics such as hydroxyapatite (HAp) are widely used materials in medical applications, especially as an interface between implants and living tissues. There are many ways of creating structures from HAp like electrochemical assisted deposition, biomimetic, electrophoresis, pulsed laser deposition or sol-gel processing. Our research is based on analyzing the parameters of the sol-gel method for creating thin layers of HAp....
-
Polarization sensitive optical coherence tomography for technical materials investigation
Publikacja -
Polarization sensitive optical coherence tomography for technical materials investigation
PublikacjaZaprezentowano system optycznej tomografii koherentnej z analizą stanu polaryzacji światła. System umożliwia nieniszczące i bezkontaktowe badanie wewnętrznej struktury materiałów warstwowych. Przedstawiono zastosowaną metodę analizy stanu polaryzacji promieniowana wstecznie rozproszonego od badanego obiektu.
-
An Optical Low-Coherence System for 2-Dimensional Visualization of Thin Polymer Layers
PublikacjaW artykule omówiono zasadę działania i przedstawiono podstawowe właściwości systemu OCT (Optical Coherence Tomography). Na przykładzie folii polietylenowej przedyskutowano możliwości wykorzystania systemu do badanie wewnętrznej struktury warstwowej obiektów niebiologicznych. Przedstawiono i omówiono wyniki przeprowadzonych badań nad warstwowymi materiałami przeźroczystymi.
-
Smart Approach for Glioma Segmentation in Magnetic Resonance Imaging using Modified Convolutional Network Architecture (U-NET)
PublikacjaSegmentation of a brain tumor from magnetic resonance multimodal images is a challenging task in the field of medical imaging. The vast diversity in potential target regions, appearance and multifarious intensity threshold levels of various tumor types are few of the major factors that affect segmentation results. An accurate diagnosis and its treatment demand strict delineation of the tumor affected tissues. Herein, we focus on...
-
Multilayered structures examination using polarization sensitive optical coherence tomography
PublikacjaW artykule przedstawiono wstępne wyniki badań struktur warstwowych z użyciem systemu optycznej tomografii koherentnej z analizą stanu poaryzacji (PS-OCT). Omówiono budowę systemu oraz zakres stosowalności metody do badania złożonych struktur warstwowych.
-
Reply to Comment on ‘Nanodiamond incorporated human liver mimicking phantoms: prospective calibration medium of magnetic resonance imaging’
PublikacjaDependence of the spin–lattice (T1) relaxation times on the nanodiamond concentration in human liver phantoms is discussed. Factors affecting stability and and reproducibility of these phantoms are presented. The need for comparative measurements on multiple MRI scanners for better understanding of potential variations in the obtained imaging data is emphasised.
-
Internal imaging of concrete fracture based on elastic waves and ultrasound computed tomography
PublikacjaThe condition assessment of concrete structures belongs to the greatest challenges of non-destructive testing. Monitoring the fracture process of concrete and detecting cracks at the earliest possible stage is a vital aspect to ensure the safety of civil engineering objects. The use of ultrasound tomography enables imaging the internal structure of a tested element. This study aims at the visualization of fracture damage in concrete...
-
Radiation therapy dosimetry using magnetic resonance imaging of polymer gels
Publikacja -
Quantitative Active Dynamic Thermal IR-Imaging and Thermal Tomography in Medical Diagnostic
PublikacjaPrinciples of Active dynamic thermal (ADT) IR-imaging and Thermal Tomography are described in details. Basic medical applications of this new modality are also discussed.
-
Non invasive optical cellular imaging in humans.
PublikacjaOne of the most appealing and still unsolved problems in biological and medical imaging is the possibility of noninvasive visualization of tissue in vivo with an accuracy of microscopic examination. A major difficulty to solve in biomedical imaging is a degradation of image quality caused by the presence of optical inhomogeneity of tissue. Is there any chance to develop a microscopic method that allows non-invasive observation...
-
T1 RELAXATION TIME CALLIBRATION IN MAGNETIC RESONANCE IMAGING USING NANODIAMOND PHANTOMS
PublikacjaMRI is increasingly used in radiation treatment planning because of the excellent soft tissue contrast in the obtained images. It allows more precise definition of the boundaries between healthy tissues and those affected by cancerous lesions. To obtain good image quality, the difference in signal between two types of tissue must be significant despite the noise so it must be properly calibrated. This calibration includes...
-
Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeter
Publikacja -
Electrochemically directed biofunctionalization of a lossy-mode resonance optical fiber sensor
PublikacjaIn this work, we present a direct electrochemical biofunctionalization of an indium-tin-oxide-coated lossy-mode resonance optical fiber sensor. The functionalization using a biotin derivative was performed by cyclic voltammetry in a 10 mM biotin hydrazide solution. All stages of the experiment were simultaneously verified with optical and electrochemical techniques. Performed measurements indicate the presence of a poly-biotin...
-
Optical monitoring of electrochemical processes with ITO-based lossy-mode resonance optical fiber sensor applied as an electrode
PublikacjaIn this work we discuss the application of optical fiber sensors based on lossy-mode resonance (LMR) phenomenon for real-time optical monitoring of electrochemical processes. The sensors were obtained by a reactive high power impulse magnetron sputtering of indium tin oxide (ITO) on a 2.5 cm-long core of polymer-clad silica fibers. The LMR effect made monitoring of changes in optical properties of both ITO and its surrounding medium...
-
Electrochemical performance of indium-tin-oxide-coated lossy-mode resonance optical fiber sensor
PublikacjaAnalysis of liquids performed in multiple domain, e.g., optical and electrochemical (EC), has recently focus significant attention. Our previous works have shown that a simple device based on indium-tin-oxide (ITO) coated optical fiber core may be used for optical monitoring of EC processes. At satisfying optical properties and thickness of ITO a lossy-mode resonance (LMR) effect can be obtained and used for monitoring of optical...
-
Tuning of the plasmon resonance location in Au nanostructures coated with a ultrathin film of Al2O3 – Optical measurements and FDTD simulations
PublikacjaThe Au nanostructures have been coated with an ultra-thin films of amorphous aluminium oxide. Optical absorption spectra show the influence of the thickness of Al2O3 on plasmon resonance wavelength. The observed red-shift of the resonance location with the increase of the thickness of the Al2O3 film, can be explained by the change in the dielectric function of this film. It allows control of the optical spectra of the coated particles....
-
The Impact of Common Epidemiological Factors on Gray and White Matter Volumes in Magnetic Resonance Imaging–Is Prevention of Brain Degeneration Possible?
Publikacja -
Three-dimensional visualization and measurement of conformal dose distributions using magnetic resonance imaging of bang polymer gel dosimeters
Publikacja -
Simultaneous optical and electrochemical label-free biosensing with ITO-coated lossy-mode resonance sensor
PublikacjaIn this work we discuss a new label-free biosensing device based on indium tin oxide (ITO) overlaid section of a multimode optical fiber fused silica core. The sensor has been used to optical measurements also simultaneously interrogated electrochemically (EC). Due to optimized thickness and optical properties of ITO film, a lossy-mode resonance (LMR) could be observed in the optical domain, where electrical properties of the film...
-
First-order magnetic transition in single-crystallineCaFe2As2detected byA75snuclear magnetic resonance
Publikacja -
Electron magnetic resonance study of the Ni47Co3Mn35.5In14.5 ribbons
Publikacja -
Enhancing electrochemical properties of an ITO-coated lossy-mode resonance optical fiber sensor by electrodeposition of PEDOT:PSS
PublikacjaA sensor working in multiple domains may offer enhanced information about the properties of an investigated analyte, including those containing biological species. It has already been shown that a dual-domain sensing capability, i.e., in optical and electrochemical domains, can be offered by lossy-mode resonance (LMR) sensors based on indium-tin-oxide (ITO) thin film. The spectral response of the LMR sensors depends on the refractive...
-
Optical low-coherence interferometry for selected technical applications
PublikacjaW artykule przedstawiono teoretyczne podstawy optycznej interferometrii niskokoherentnej i przedyskutowano jej unikatowe właściwości. Opisano w nim opracowany przez autorów system OCT przeznaczony do badań strukturalnych materiałów technicznych. Badania te obejmują także zmiany stanu polaryzacji promieniowania rozproszonego w badanym obiekcie. W artykule zawarto wyniki badań wybranych materiałów silnie rozpraszających promieniowanie...
-
Corrigendum to “T1 relaxation time callibration in magnetic resonance imaging using nanodiamond phantoms” [Phys Med 94 (2022) S119–S120/EPV029]
PublikacjaThe authors want to update the incorrect funding information. The correct funding note is: “The authors acknowledge the financial support from Gdańsk University of Technology by the 4/2020/IDUB/III.4.1/Tc grant under the Technetium Talent Management Grants ‘Excellence Initiative – Research University’. The financial support from Gdańsk University of Technology by the 1/2021/IDUB/II.2/Np grant under NEPTUNIUM Enhancing Baltic Region...
-
Activation maps of convolutional neural networks as a tool for brain degeneration tracking in early diagnosis of dementia in Parkinson's disease based on magnetic resonance imaging
Publikacja -
Common methods for the chiral determination of amphetamine and related compounds II: Capillary electrophoresis and nuclear magnetic resonance
PublikacjaAmphetamine group and related ring-substituted substances are generally synthetic compounds, belonging to one of the most heavily abused drug groups in recent years. Some compounds in this class also originate from plants. Analysis of the enantiomers of AM-type compounds and metabolites is extremely important for a number of scientific disciplines. From studies of biological activity or mechanisms through determination of precursor...
-
Nuclear Magnetic Resonance Metabolomics Reveals Qualitative and Quantitative Differences in the Composition of Human Breast Milk and Milk Formulas
PublikacjaCommercial formula milk (FM) constitutes the best alternative to fulfill the nutritional requirements of infants when breastfeeding is precluded. Here, we present the comparative study of polar metabolite composition of human breast milk (HBM) and seven different brands of FM by nuclear magnetic resonance spectroscopy. The results of the multivariate data analysis exposed qualitative and quantitative differences between HBM and...
-
Theoretical and experimental investigation of Optical Coherent Tomography topologies
PublikacjaW artykule przedstawiono teoretyczną i eksperymentalną analizę konfiguracji interferometrów w układach koherentnego tomografu optycznego. Zaprezentowano zrealizowany układ, którego specjalnie zaprojektowana konfiguracja pozawala na analizę zmian polaryzacji sygnału pomiarowego.
-
Spectroscopic analysis for polarization sensitive optical coherent tomography
PublikacjaW artykule przedstawiono właściwości oraz ograniczenia optycznej tomografii koherentnej z analizą stanu polaryzacji promieniowania optycznego. Zaproponowano nową spektroskopową metodę analizy sygnału pomiarowego w PS-OCT oraz przedstawiono i omówiono zalety nowego rozwiązania na bazie uzyskanych wyników pomiarowych.
-
<title>Synthesized light source for optical coherence tomograph</title>
Publikacja -
Fiber - optic low-coherence tomography system for visualization of internal structure of ceramic materials
PublikacjaW artykule przedstawiono światłowodowy system dwuwymiarowej wizualizacji niejednorodnych struktur warstw ceramicznych. Omówiono projekt i fizyczną realizację układu wykorzystującego optyczną, niskokoherentną reflektometrię optyczną, która umożliwia niedestrukcyjne obrazowanie wewnętrznych struktur różnych materiałów. W pracy przedstawiono przykładowe wyniki pomiarów wewnętrznych warstw LSFO.
-
First-order magnetic transition in single-crystalline CaFe2As2 detected by 75As nuclear magnetic resonance
PublikacjaPrzedstawione są wyniki badań jądrowego rezonansu magnetycznego na 75As dla kryształów CaFe2As2. Wyniki wskazują, że strukturalne i magnetyczne przejścia w CaFe2As2 są silnie skorelowane i są pierwszego rodzaju.
-
Quantitative Active Dynamic Thermal IR-Imaging and Thermal Tomography in Medical Diagnostics
Publikacja.
-
Quantitative active dynamic thermal Ir-Imaging and thermal tomography in medical diagnostics
Publikacja -
Quantitative active dynamic thermal ir-imaging and thermal tomography in medical diagnostics
PublikacjaPraca dotyczy nowych technik obrazowania w diagnostyce medycznej, wykorzystując przetwarzanie obrazów termicznych rejestrowanych w podczerwieni. Opisano właściwości termiczne tkanek biologicznych, omówiono medele termiczne i zdefiniowano zastępcze parametry syntetyczne, metody pomiarów i stosowane urządzenia. Omówiono procedury akwizycji danych i ich przetwarzania. Wprowadzono pojęcie tomografii termicznej. Opisano przeprowadzone...
-
Mixture Model Based Efficient Method for Magnetic Resonance Spectra Quantification
Publikacja -
Strategies for optimizing the phase correction algorithms in Nuclear Magnetic Resonance spectroscopy
Publikacja -
First detection of spectral resonance structures of the ionospheric Alfvén resonance in ULF/ELF magnetic field recorded at Suwałki, Poland
Publikacja -
Spectral profiling of radicals in polymer degradation based on electron spin resonance imaging (ESRI)
Publikacja -
Imaging of Increasing Damage in Steel Plates Using Lamb Waves and Ultrasound Computed Tomography
PublikacjaThis paper concerns inspection of steel plates, with particular emphasis on the assessment of in-creasing damage. Non-destructive tests were performed on four plates, one of which was un-damaged, while the remaining three had a defects in the form of circular holes with a diameter of 2, 5, and 10 cm. Guided Lamb waves were used in the research, and the image reconstruction was performed using ultrasound computed tomography. The...
-
Tome-lapse X-ray tomography imaging of flow patterns in versatile silo model
PublikacjaThe paper introduces a new versatile silo model that was especially designed for in situ X-ray tomography studies of silo discharge for various flow conditions, namely concentric and eccentric. The presented work focuses on organic granular materials where low fraction of short-grain white rice is mixed with spheroidal sorghum particles. The high-quality tomography images combined with adequate image processing strategy allows...
-
Ultrahigh-resolution detection techniques for biomedical applications of optical coherent tomography.
PublikacjaOptyczne metody pomiarowe odgrywają w ostatnich latach coraz większą rolę w badaniach i diagnostyce medycznej. Mają one szereg zalet, do których zaliczyć można odporność na promieniowanie elektromagnetyczne, bezinwazyjność, bezpieczeństwo pomiaru oraz wysoką rozdzielczość. Jedną z najważniejszych technik stosowanych w diagnostyce medycznej jest koherentna tomografia optyczna (OCT). Jest to wysokorozdzielcza metoda obrazowania wewnętrznych...
-
<title>Fiber-optic low-coherence tomography system for visualization of internal structure of ceramic materials</title>
Publikacja -
Surface plasmon resonance imaging biosensor for cathepsin G based on a potent inhibitor: Development and applications
Publikacja -
Investigation of energy deposition and its optical imaging in polymer gel dosimeters
PublikacjaThis following chapter describes methods for verifying the absorbed dose during radiotherapy. Special attention is paid to the method using polymer-gel dosimeters, the dose reading of which is performed by means of Laser Computed Tomography. The chapter also includes considerations on alternative solutions for dosimetric measurements and various types of radiotherapy and their pros and cons. In addition, both the methods of structural...
-
Numerical Estimate of the Spectral Resonance Structure Frequency Scale of Natural ULF Magnetic Field
Publikacja -
Measuring Diffusion Coefficients of Nitroxide Radicals in Heterophasic Propylene−Ethylene Copolymers by Electron Spin Resonance Imaging
Publikacja -
ESCASA : Analytical estimation of atomic coordinates from coarse‐grained geometry for nuclear‐magnetic‐resonance ‐assisted protein structure modeling. I. Backbone and Hβ protons
PublikacjaA method for the estimation of coordinates of atoms in proteins from coarse-grained geometry by simple analytical formulas (ESCASA), for use in nuclear-magnetic-resonance (NMR) data-assisted coarse-grained simulations of proteins is proposed. In this paper, the formulas for the backbone Hα and amide (HN) protons, and the side-chain Hβ protons, given the Cα-trace, have been derived and parameterized, by using the interproton distances...
-
Comparison of resonance optical scattering of plane waves by infinite gratings of silver cylinders and strips
Publikacja -
<title>Ultrahigh-resolution detection techniques for biomedical applications of optical coherent tomography</title>
Publikacja -
<title>Modeling of broadband light source to use with optical coherent tomography system</title>
Publikacja -
Non-destructive inspection of anti-corrosion protective coatings using optical coherent tomography
PublikacjaW artykule przedstawiono zastosowanie optycznej tomografii koherentnej (OCT) do badania antykorozyjnych powłok ochronnych. Omówiono właściwości optycznej interferometrii niskokoherentnej jako zastosowanej metody pomiarowej, opisano budowę pomiarowego systemu OCT, zbudowanego w Katedrze Metrologii i Optoelektroniki WETI PG. Przy pomocy zrealizowanego systemu przebadano grupę powierzchni metalicznych pokrytych różnymi powłokami antykorozyjnymi....
-
<title>An optical low-coherence system for 2-dimensional visualization of thin polymer layers</title>
Publikacja -
Determination of cathepsin G in endometrial tissue using a surface plasmon resonance imaging biosensor with tailored phosphonic inhibitor
Publikacja -
Bimodal Nd-Doped LuVO4 Nanoprobes Functionalized with Polyacrilic Acid for X-Ray Computed Tomography and NIR Luminescent Imaging
Publikacja -
Dynamic Study of Dual High-Power Impulse Magnetron Sputtering Discharge by Optical Emission Imaging
Publikacja -
Effect of Double-Slope Modulation Signals on Conducted Emissions and Efficiency of Strongly Coupled Magnetic Resonance WPT Systems
Publikacja -
Quantitative magnetic resonance assessment of brain atrophy related to selected aspects of disability in patients with multiple sclerosis: preliminary results
Publikacja -
On Raman optical activity sign-switching between the ground and excited states leading to an unusual resonance ROA induced chirality
Publikacja -
Ln2(SeO3)2(SO4)(H2O)2 (Ln=Sm, Dy, Yb): A Mixed‐Ligand Pathway to New Lanthanide(III) Multifunctional Materials Featuring Nonlinear Optical and Magnetic Anisotropy Properties
PublikacjaBottom-up assembly of optically nonlinear and magnetically anisotropic lanthanide materials involving precisely placed spin carriers and optimized metal-ligand coordination offers a potential route to developing electronic architectures for coherent radiation generation and spin-based technologies, but the chemical design historically has been extremely hard to achieve. To address this, we developed a worthwhile avenue for creating...
-
Study of Aliphatic Polyurethanes by the Low-Field 1H NMR Relaxometry Method with the Inversion of the Integral Transformation
PublikacjaIn this paper, the distributions of the 1H nuclear magnetic resonance (NMR) spin–lattice and spin–spin relaxation times are used to characterize the mobility of different sections of macromolecules of aliphatic polyurethanes and the cross-linking density of polymer chains. The NMR relaxometry method with inversion of integral transformation is applied to study the effect of poly (ethylene glycol) and glycerol phosphate calcium...
-
ID and 2D Electron Spin Resonance Imaging (ESRI) of Nitroxide Radicals in Stabilized Poly(acrylonitrile−butadiene−styrene) (ABS): UV vs Thermal Degradation
Publikacja -
Microemulsion-Mediated Synthesis and Properties of Uniform Ln:CaWO4(Ln = Eu, Dy) Nanophosphors with Multicolor Luminescence for Optical and CT Imaging
Publikacja