wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: AUTOMATIC SYSTEM, OPTICAL MEASUREMENTS, MEASUREMENTS OF BIOLOGICAL TISSUES
-
Framework for extracting rails and setting-out railway line axis based on UAV photogrammetric measurements
PublikacjaTechnical diagnostics enables assessing the current technical condition of a railway line and adjacent infrastructure, and forecasting its changes over a specific time horizon. One of its elements is the periodic monitoring of rail position and their geometry. This article presents a new framework for the setting-out of a railway track axis. The process presented in the manuscript is based on the specific filtration and extraction...
-
Application of image processing methods for the characterization of selected features and wear analysis in surface topography measurements
Publikacja -
Selected Aspects of Testing the Positioning Accuracy of GNSS Receivers Used in Sports and Recreation by Dynamic Measurements
Publikacja -
Framework for extracting rails and setting-out railway line axis based on UAV photogrammetric measurements
Publikacja -
Evaluation of the possibility of identifying a complex polygonal tram track layout using multiple satellite measurements
Publikacja -
Measurements of displacement and acceleration of the railway bridge at km 333-254 of the Vilnius - Klaipeda railway line
PublikacjaThe purpose of this work is to perform a report of static and dynamic test realized on the bridge at km 333-254 of the Vilnius - Klaipeda railway line over the Salantas River in Kūlupėnų.
-
Device characteristics extraction by low frequency noise measurements; Someresults on the state-of-the-art MOSFET´s
PublikacjaPrzedstawiono wyniki pomiarów i analizy szumów tranzystorów MOSFET z izolatorem bramki wykonanym z SiO2 i HfO2. Wyniki pomiarów wykorzystano do oszacowania gęstości aktywnych stanów na powierzchni użytego tlenku i porównano z wynikami otrzymanymi metodą charge-pumping.
-
Measurements of absolute total cross sections for electron scattering fromtriatomic polar molecules: SO2 and H2S.
PublikacjaZmierzono całkowity przekrój czynny na rozproszenie elektronów na SO2 i H2S.Pomiary przeprowadzono na zmodyfikowanym spektrometrze elektronów pracującym w oparciu o metodę transmisyjną.
-
Dynamic elektrochemical impedance spectroscopy measurements of passive layer cracking under static tensile stresses.
PublikacjaDynamiczna elektrochemiczna spektroskopia impedancyjna umożliwia badanie podatności i odporności korozyjnej różnych materiałów konstrukcyjnych, a w szczególności określenie właściwości elektrochemicznych warstw pasywnych występujących na ich powierzchni. W wielu przypadkach pęknięcie warstwy pasywnej pod wpływem działania naprężeń rozciągających prowadzi do korozji naprężeniowej. Z tego względu badania pękania warstw pasywnych...
-
Dynamic electrochemical impedance spectroscopy measurements of passive layer cracking under static tensile stresses.
PublikacjaDynamiczna Elektrochemiczna Spektroskopia Impedancyjna umożliwia badanie podatności i odporności korozyjnej różnych materiałów konstrukcyjnych, a w szczególności określenie właściwości elektrochemicznych warstw pasywnych występujących na ich powierzchni. W wielu przypadkach pęknięcie warstwy pasywnej pod wpływem działania naprężeń rozciągających prowadzi do korozji naprężeniowej. Z tego względu badania pękania warstw pasywnych...
-
Measurements of glucose content in scattering media with time-of-flight technique: comparison with Monte Carlo simulations.
PublikacjaZbadano możliwości pomiaru koncentracji glukozy w materiale silnie rozpraszającym światło z wykorzystaniem techniki czasu przelotu. Badania przeprowadzono wykorzystując ''Intralipid'' będącym fantomem tkanki. Stężenie glukozy wynosiło 100, 200, 300, 500, 1000, 2000,4000 lub 8000 mg/dl. Wyniki pomiarów porównano z wynikami uzyskanymi na drodze modelowania matematycznego.
-
Assessment of the Positioning Accuracy of DGPS and EGNOS Systems in the Bay of Gdansk using Maritime Dynamic Measurements
Publikacja -
Comparative analysis of positioning accuracy of GNSS receivers of Samsung Galaxy smartphones in marine dynamic measurements
Publikacja -
AeroSense Measurements: Wind Tunnel EPFL
Dane BadawczeData from wind tunnel tests of Aerosesne measurement system installed on NACA63418 at EPFL wind tunnel.
-
Measurements of the chemical composition of LTO:Cu powders
Dane BadawczeLithium titanate doped by copper was measured by X-ray photoemission spectroscopy (XPS). For sol-gel synthesis lithium acetate dehydrate and titanium (IV) butoxide 97% and copper (II) nitrate from Alfa Aesar were used as a reagents. Cu precursor was added in the proper weight to get an x index equal 0, 0.1 and 0.2. In the first step lithium acetate...
-
Accumulation and fate of selected heavy metals in biological wastewater treatment system
PublikacjaBadano akumulację oraz stopień usuwania metali ciężkich (Cd, Cu, Pb, Zn) w systemie biologicznego oczyszczania ścieków. Porównano zawartość wybranych metali w ściekach surowych i oczyszczonych, a także ich stężenie w osadzie czynnym przed i po beztlenowej stabilizacji.
-
Modeling of broadband light source to use with optical coherenttomography system
PublikacjaW pracy przedstawiono modelowanie źródeł szerokopasmowych na potrzeby systemów koherentnej tomografii optycznej z punktu widzenia uzyskiwanej zdolności podłużnej i jakości otrzymywanych obrazów. Pokazano na przykładzie źródła szerokopasmowego wykorzystującego światłowód fotoniczny do generacji w wyniku zjawisk nieliniowych ''supercontinuum'' wpływ kształtowania wiązki na możliwości pomiarowe systemu OCT.
-
Proposal of a mobile medical waste incinerator with automatic waste feeder and heat recovery system
PublikacjaThe paper presents and discusses the issue of medical waste (including hazardous ones) and their proper management. Inappropriate handling of infectious medical waste directly endangers the human being health and the environment. Infectious waste must therefore be properly disposed of – one of the most commonly used methods is the thermal treatment in the incinerators tailored for this purpose. During designing an incinerator unit,...
-
Electrochemical impedance spectroscopy measurements - conductivity vs. temperature and conductivity vs. oxygen partial pressure - BaCe0.6Zr0.2Y0.1Tb0.1O3-δ
Dane BadawczeThe dataset consists of two main catalogs consisting of measurement data: of the electrical conductivity of the BaCe0.6Zr0.2Y0.1Tb0.1O3-δ (BCZYTb) sample as a function of temperature and of the electrical conductivity as a function of oxygen partial pressure (pO2). Measurements as a function of temperature were carried out in dry and wet air (pH2O ~...
-
Measurement data of cyclic voltammetry and electrochemical impedance measurements of carbon samples synthesized on axes and off axes
Dane BadawczeThe electrochemical performance of the multielectrode samples were investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) using a VMP-300 BioLogic galvanostat potentiostat (France) under the EC-lab software. All electrochemical investigations were carried out in a three-electrode cell system. The carbon multi-electrode,...
-
The fixed state in impedance measurements of a two-step electrode reaction proceeding with accompanying adsorption of an intermediate product
Publikacja -
Solubility of sulfanilamide in binary solvents containing water: Measurements and prediction using Buchowski-Ksiazczak solubility model
Publikacja -
A novel sandwich footbridge - Practical application of laminated composites in bridge design and in situ measurements of static response
PublikacjaA novel sandwich composite footbridge is presented in the paper, as an example of practical application of laminated composites in civil engineering. The in situ static load tests of the footbridge before its acceptation for exploitation are shown and discussed. The results are compared with the corresponding ones from a numerical equivalent single layer model of the sandwich structure created within the framework of finite element...
-
Assessment of fatigue life of aluminized, coarse-grained MAR247 alloy supported by full-field ESPI measurements
Publikacja -
Increasing Energy Efficiency and Productivity of the Comminution Process in Tumbling Mills by Indirect Measurements of Internal Dynamics—An Overview
Publikacja -
Folding kinetics of WW domains with the united residue force field for bridging microscopic motions and experimental measurements
Publikacja -
Towards Designing an Innovative Industrial Fan: Developing Regression and Neural Models Based on Remote Mass Measurements
PublikacjaThis article presents the process of the construction and testing a remote, fully autonomous system for measuring the operational parameters of fans. The measurement results obtained made it possible to create and verify mathematical models using linear regression and neural networks. The process was implemented as part of the first stage of an innovative project. The article presents detailed steps of constructing a system to...
-
Suppression of the High-Frequency Errors in Surface Topography Measurements Based on Comparison of Various Spline Filtering Methods
Publikacja -
Investigation of DPPC effect on SiO2 particles and in the presence of phospho(lipases) by zeta potential and effective diameter measurements
Publikacja -
Investigations of DPPC effect on Al2O3 particles in the presence of (phospho)lipases by the zeta potential and effective diameter measurements
Publikacja -
Measurements of OF QoS/QoE parameters for media streaming in a PMIPv6 TESTBED WITH 802.11 b/g/n WLANs
PublikacjaA growing number of mobile devices and the increasing popularity of multimedia services result in a new challenge of providing mobility in access networks. The paper describes experimental research on media (audio and video) streaming in a mobile IEEE 802.11 b/g/n environment realizing network-based mobility. It is an approach to mobility that requires little or no modification of the mobile terminal. Assessment of relevant parameters...
-
Measurements of Spectral Spatial Distribution of Scattering Materials for Rear Projection Screens used in Virtual Reality Systems
PublikacjaRapid development of computing and visualisation systems has resulted in an unprecedented capability to display, in real time, realistic computer-generated worlds. Advanced techniques, including three-dimensional (3D) projection, supplemented by multi-channel surround sound, create immersive environments whose applications range from entertainment to military to scientific. One of the most advanced virtual reality systems are CAVE-type...
-
Measurements of Activity Coefficients at Infinite Dilution for Organic Solutes in the Ionic Liquids N-Ethyl- and N-Octyl-N-methylmorpholinium Bis(trifluoromethanesulfonyl)imide. A Useful Tool for Solvent Selection
PublikacjaIn recent years, many papers describing ionic liquids (IL) as promising solvents in separation techniques have been published. The conscious choice of appropriate ionic liquid as absorption media in effective extraction of selected types of analytes requires deeper understanding of the analyte−IL interactions. Therefore, intensive research is conducted to determine the values of activity coefficient at infinite dilution, which...
-
Measurement file of PEEK 70 mm bushing measurements in original condition perforemed on custom-built 3d measuring stand
Dane BadawczeAfter manufacturing process (lathe turning) bearing was measured on custom bulit measurement stan developed during research project financed by National Centre of Science. Measurements consist of 110 000 points in 3D space taken on bushing inner surface. Bearing was measured taking vertical steps of 0,2 mm.
-
Measurements of photoionization of mercury atoms into the 6s 2S1/2, 5d96s2 2D5/2 and 5d96s2 2D3/2 ionic states over the energy range from 10.5 eV to 18.7 eV
PublikacjaPhotoionization of mercury atoms into the three lowest ionic states, 5d106s 2S1/2, 5d96s2 2D5/2 and 5d96s2 2D3/2 has been studied in the photon energy ranges from their respective thresholds to 18.7 eV. The photoionization spectra were obtained with high energy resolution at an angle of 0° with respect to the polarization vector of the photon beam. The high energy resolution and sensitivity achieved in the measurements permitted...
-
Long term measurements of PM1, PM2.5, PM10 and NO2 in open-air at Gdansk (Poland) area using low-cost sensors together with the reference results
Dane BadawczeThe measurements results of open-air measurements made using the following low-cost sensors: particulate matter (PM) sensor SPS30 from Sensirion, NO2 electrochemical sensor SGX-7NO2 from SGX Sensortech, NO2 electrochemical sensor 7E4-NO2 from SemaTech, compact MOS air quality sensor MiCS 2714 from SGX Sensortech, BME280 (Bosch) environmental sensor...
-
Simultaneous measurements of ECG, body Impedance and temperature
Dane BadawczeThe data are complementary part of the experiment designed to demonstrate how to use the network protocols to transmit medical data. The dataset contains biomedical signals of ECG, Impedanc and temperature acquired simultaneously. The data allow students to become familiar with data acquisition methods (simulate data transmission by medical device over...
-
AeroSense Measurements: Wind Tunnel ETH Zurich
Dane BadawczeData from wind tunnel tests of Aerosesne measurement system installed on NACA 0012 at ETH Zurich wind tunnel.
-
XPS measurements of the Fe-Bi based glass
Dane BadawczeFe-Si-O and Fe-Si-Pb-O glass was measured by XPS method. The influence of Pb dopand on the glass structure, including the valence of iron, was investigated. The influence of the annealing temperature on the behavior of iron in glass was also investigated. Studies have confirmed the mixed valence of iron in glasses and a high proportion of metallic Fe.
-
Miscanthus × giganteus growth and photosynthetic rate measurements
Dane BadawczeThis data set contains the findings of the growth development, gas exchange, and specific leaf area of the plants during the experiment in which straw and wood chips-based biochars were used as soil amendment for Miscanthus × giganteus (M×g) cultivation.
-
Experimental data of galvanic electric cells measurements
Dane BadawczeInternal temperature of an electric cell can be measured and monitored using microsphere-based fiber-optic sensors with thin ALD ZnO coating. Their compact size will allow to integrate them easily and effectively within the electric cells. Utilization of presented sensors allows to detect, in real time, damages to the structure of the sensor head that...
-
Electrical performance measurement of reference and SOFC with LSCNT layer fueled by H2 and 20ppm H2S/biogas mixture at 750 C - cyclic measurements (12h per cycle)
Dane BadawczeThe dataset contains the electrical IV measurements collected during the cyclic measurements of H2S poisoning in DIR-SOFC with/-out LSCNT layer. The H2S poisoning and H2 regenrating cycles were 12 h each. The spectra were collected every 10 min.
-
Measurements of ultrasonic bulk and guided wave propagation in additively manufactured cubes and plates obtained by ultrasonic pulse velocity analyzer and scanning laser vibrometry
Dane BadawczeThe DataSet contains the results of measurements of ultrasonic wave propagation in additively manufactured samples made of polylactic acid (PLA). Three types of raster angles in two consecutive layers were assumed: 0°/90° (#1), 45°/-45° (#2) and 90°/90° (#3) with respect to the x-axis. For each printing variants a cubic sample (#C1-3) with dimensions...
-
Measurements and calculation of self inductance of testing coils used in physical transformer model construction and its frequency analysis
Publikacja -
Direct measurements and numerical predictions of welding-induced initial deformations in a full-scale steel stiffened plate structure
Publikacja -
Pitting corrosion characterization by electrochemical noise measurements on asymmetric electrodes. [DOI 10.1007/s10008-008-0643-y]
PublikacjaObecność korozji wżerowej może być wykryta na podstawie występowania charakterystycznych przebiegów prądu płynącego między dwiema elektrodami, których wyprowadzenia są zwarte. Autorzy proponują nową metodę, która zachowuje informacje o stałej czasowej tych charakterystycznych dla procesów wżerowania przebiegów. Metoda została zastosowana do analizy szumów występujących podczas korozji stali 0H18N9 pod wpływem 1M roztworu FeCl3...
-
Cutting forces and temperature measurements in cryogenic assisted turning of AA2024-T351 alloy: An experimentally validated simulation approach
Publikacja -
Raman scattering measurements in monitoring of polymer synthesis process. Lightmetry 2002 : Metrology and Testing Techniques Using Light.
PublikacjaW artykule omówiono możliwości wykorzystania pomiarów ramanowskich do monitorowania w czasie rzeczywistym przebiegu procesów syntezy materiałów polimerowych. Wykorzystano sondy światłowodowe do sprzęgnięcia aparatury pomiarowej z typowym stanowiskiem technologicznym. Pomiary miały charakter zdalny, nieniszczący i niezakłócający przebieg reakcji.
-
Water retention curves of sandy soils obtained from direct measurements, particle size distribution, and infiltration experiments
PublikacjaAccurate information about soil water retention curves (SWRCs) of sands is essential for evaluating groundwater recharge and vulnerability to contamination in many shallow sandy aquifers which are widespread on post glacial areas in Northern Europe and North America. Pedotransfer functions (PTFs) allow to estimate SWRC from basic physical characteristics of soils, such as textural composition. However, in the case of clean sands...
-
Study on the applicability of the measurements of magnetoelastic properties for a nondestructive evaluation of thermally inducted microstructure changes in the P91 grade steel
PublikacjaThe paper presents the resuIts of the investigation of the influence of duration and temperature oftempering process on the magnetoacoustic properties of P91 tempered martensite ferritic steeI. Duringtempering of martensitic steels the dislocation density. which initially is very high. systematicallydecreases what is confirmed both by analysis of the width of X-ray diffraction peaks and hardnessmeasurements. Magnetic hysteresis...