Filtry
wszystkich: 23151
-
Katalog
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: SAMPLE PREPARATION, EXTRACTION
-
The Application of 2,6-Bis(4-Methoxybenzoyl)-Diaminopyridine in Solvent Extraction and Polymer Membrane Separation for the Recovery of Au(III), Ag(I), Pd(II) and Pt(II) Ions from Aqueous Solutions
Publikacja -
Multianalyte Calibration Methods for Potentiometric Integrated Sensors System for Determination of Ions Concentration in a Body Fluids
PublikacjaIn recent years, integration and miniaturization of ion-selective electrodes (ISEs) have brought many benefits resulting in the possibility of simultaneous determination of the ions concentration in a small sample volume. One of the key problems related to the preparation of integrated sensors systems (ISSs) is a calibration procedure due to the necessity to calibrate each particular sensor separately. The main aim of the research...
-
Application of deep eutectic solvents in bioanalysis
PublikacjaThe application of deep eutectic solvents (DESs) is sharply surging as a green alternative to conventional solvents due to their unique properties in terms of simplicity of preparation, designability and low cost. A great deal of attention has been paid to the application of these green solvents in analytical chemistry in recent years, and a lot of interesting work has been reported. This review summarizes the most relevant applications...
-
Polymeric porous membranes as solid support and protective material in microextraction processes: A review
PublikacjaPolymeric porous membranes have proven to be a versatile and efficient material for microextraction processes. In analytical practice, they are used both as a solid support and as a protective medium for improved sample preparation in various analytical applications. Polymeric porous membranes offer unique advantages in microextraction due to their large surface area and controllable pore size, eliminating interfering effects from...
-
CV (cyclic voltammetry) curves of the CPMD sample at different scan rates
Dane BadawczeThese data contain CV curves of CPMD obtained at a scan rate from 1 mV s−1 to 20 mV s−1. Sample abbreviations (CPMD) are in agreement with the markings used in the linked publication.
-
Microextraction Techniques Used in the Procedures for Determining Organomercury and Organotin Compounds in Environmental Samples
PublikacjaDue to human activities, the concentrations of organometallic compounds in all parts of the environment have increased in recent decades. The toxicity and some biochemical properties of mercury and tin present in the environment depend on the concentration and chemical form of these two elements. The ever-increasing demand for determining compounds at very low concentration levels in samples with complex matrices requires...
-
Determination of Glycerol, Propylene Glycol, and Nicotine as the Main Components in Refill Liquids for Electronic Cigarettes
PublikacjaRefill liquids for electronic cigarettes are an important area of research due to the health safety and quality control of such products. A method was developed for the determination of glycerol, propylene glycol, and nicotine in refill liquids using liquid chromatography, coupled with tandem mass spectrometry (LC-MS/MS) in multiple reaction monitoring (MRM) mode with electrospray ionisation (ESI). Sample preparation was based...
-
DES - polarity, pH and antioxidant potential
Dane BadawczeThis physicochemical properties of selected deep eutectic solvents (DES) were tested. Polarity is important for extraction efficiency. The values of pH can importantly affect growing of bacteria and yeasts strains. Total phenolic content, DPPH and FRAP methods were used for determination of antioxidant potential of the extract produced with DES.
-
Studies on applicability of new solid-phase microextraction and determination of short - chain monocarboxylic acids
PublikacjaA convenient approach to monitor the short-chain monocaroboksylic acids (SCAMs) in different samples is gas chromatography (GC) preceded by sample preparation based on solid-phase microextraction (SPME). The fiber with polar coatings were used to extract the SCAMs from headspace of liquid and solid samples. Recently polimeric ionic liquid (PIL) fiber coatings have been proposed to extract volatile organic compounds, minly polar...
-
Maximum forces in tendon connections for an anchor with a pin in the full sample experiment
Dane BadawczeThe main objective of the all study was to assess the load capacity of a new implant device for knotless tendon anastomosis. During this series of experiments the load capacity of the anchoring element with a pin (see figure 1) was examined. Tendons from fresh swine legs (commercially available) served as the biological material. All samples were subjected...
-
Thermal properties. DSC analysis of poly(xylitol sebacate-co-butylene sebacate) PXBS.
Dane BadawczeIn this work, a bio-based copolyester with good mechanical properties was synthesized andcharacterized in terms of structure, main properties and biodegradability Determining the chemicalstructure of such materials is important to understand their behavior and properties. Performingan extraction of insoluble cross-linked polymer using di erent solvents...
-
Distillation cleanup preceded gc determination of short-chain monocarboxylic acids in aqueous and solid samples of wastewater origin = Oznaczanie krótkołańcuchowych kwasów monokarboksylowych w próbkach wodnych i stałych pochodzących z oczyszczalni ścieków z wykorzystaniem chromatografii gazowej poprzedzonej destylacją
PublikacjaShort-chain monocarboxylic acids (SCMAs) (C2-C5) formed in the process of aerobic biodegradation of larger organic molecules should often be monitored to optimize wastewater biological treatment and study the processes of converting organic waste matter into methane, etc. Gas chromatography (GC) seems a method of choice for such a task. Majority of samples require clean up before they can be injected into GC system. In this work...
-
Box-Behnken design optimization of pipette tip solid phase extraction for methyl orange and acid red determination by spectrophotometry in seawater samples using graphite based magnetic NiFe2O4 decorated exfoliated as sorbent
Publikacja -
FLAME ATOMIC ABSORPTION SPECTROMETRIC DETERMINATION OF TRACE AMOUNTS OF SILVER IN RADIOLOGICAL WASTE SAMPLES AFTER SOLID PHASE EXTRACTION USING MULTI-WALLED CARBON NANO-TUBES MODIFIED BY SODIUM DODECYL SULFATE
Publikacja -
Determination of antifreeze substances in the airport runoff waters by solid-phase microextraction and gas chromatography–mass spectrometry method
PublikacjaA new method has been developed for the determination of antifreeze agents such as ethylene glycol (EG), propylene glycol (PG), and diethylene glycol (DEG) in the samples of airport runoff water. The method is based on headspace solid–phase microextraction (HS–SPME) of target analytes, which is coupled with gas chromatography–mass spectrometry (GC–MS). Until now, there was a lack of appropriate methodology for collecting reliable...
-
Dispersive liquid-liquid microextraction combined with gas chromatography–mass spectrometry for in situ determination of biogenic amines in meat: Estimation of meat's freshness
PublikacjaA dispersive liquid-liquid microextraction (DLLME) gas chromatography–mass spectrometry (GC–MS) technique was developed for the determination of selected biogenic amines (BAs) in samples of poultry, pork and beef. Prior to the extraction process, an appropriate volume of sodium hydroxide solution was added to each of the portioned samples. Next, samples were homogenized, centrifuged and finally sonicated at an increased temperature....
-
The cement-bone bond is weaker than cement-cement bond in cement-in-cement revision arthroplasty. A comparative biomechanical study
PublikacjaThis study compares the strength of the native bone-cement bond and the old-new cement bond under cyclic loading, using third generation cementing technique, rasping and contamination of the surface of the old cement with biological tissue. The possible advantages of additional drilling of the cement surface is also taken into account. Femoral heads from 21 patients who underwent a total hip arthroplasty performed for hip arthritis...
-
Application of chromogenic dye in biogenic amines determination using spectrophotometry
PublikacjaBiogenic amines content can be the source of information in the field of freshness and suitability of certain foods for consumption. However, most analytical methods for their determination require complicated sample preparation and expert knowledge. Because of that, a novel approach based on chromogenic dye application was proposed. After the SN1 reaction of an amine with S 0378 dye, the absorbance of the solution was measured...
-
Development of a solventless stir bar sorptive extraction/thermal desorption large volume injection capillary gas chromatographic-mass spectrometric method for ultra-trace determination of pyrethroids pesticides in river and tap water samples
Publikacja -
Application of Box–Behnken design in the optimization of a simple graphene oxide/zinc oxide nanocomposite-based pipette tip micro-solid phase extraction for the determination of Rhodamine B and Malachite green in seawater samples by spectrophotometry
Publikacja -
Efficient Recovery of Noble Metal Ions (Pd2+, Ag+, Pt2+, and Au3+) from Aqueous Solutions Using N,N'-Bis(salicylidene)ethylenediamine (Salen) as an Extractant (Classic Solvent Extraction) and Carrier (Polymer Membranes)
Publikacja -
Bio-based polyester polyols for polyurethane foams - chemical structure of reference sample
Dane BadawczePresented dataset includes the results of FTIR and H NMR spectroscopy of bio-based polyester polyol - poly(propylene succinate) (reference sample for materials obtained during MINIATURA 4 project realization).
-
Dependence between Ionic Liquid Structure and Mechanism of Visible-Light-Induced Activity of TiO2 Obtained by Ionic-Liquid-Assisted Solvothermal Synthesis
PublikacjaBecause of the tremendous structural diversityof ionic liquids (ILs), simple transfer of observations performed for one IL used for IL-TiO2 preparation on different samples is not possible. Therefore, four ionic liquids, all containing distinct nitrogen-bearing organic cations (pyridinium, pyrrolidinium, ammonium, imidazolium), were used for the first time for the preparation of IL-TiO2 composites. The role of the individual IL...
-
Main strategies, analytical trends and challenges in LC-MS and ambient mass spectrometry-based metabolomics
PublikacjaA plethora of analytical LC-MS-based methods have been successfully applied to analyses of complex samples of various origin for metabolomics investigations. Over the last ten years, the substantial evolution of ambient mass spectrometry (AMS) techniques has highlighted their tremendous potential in metabolomic studies due to the minimal sample pretreatment requirement and the ability to analyse samples in their native state. This...
-
Application of deep eutectic solvents in atomic absorption spectrometry
PublikacjaAtomic absorption spectrometry (AAS) is a widely applied technique for metal quantification due to its practicality, easy use and low cost. However, to improve the metrological characteristics of AAS, in particular the sensitivity and the detection limit, sample pretreatment is commonly used before the detection step itself. In consideration of the principles of Green Analytical Chemistry, new solvents are being introduced into...
-
Maximum forces in tendon connections for an anchor with pin in the single-side sample experiment
Dane BadawczeThe main objective of the all study was to assess the load capacity of a new implant device for knotless tendon anastomosis. During this series of experiments the load capacity of the anchoring element with a pin (see figure 1) was examined. Tendons from fresh swine legs (commercially available) served as the biological material. All samples were subjected...
-
Maximum forces in tendon connections for the Kessler suture in the single-side sample experiment
Dane BadawczeThe main objective of the all study was to assess the load capacity of a new implant device for knotless tendon anastomosis. During this series of experiments the load capacity of the traditional two-strand Kessler sutures (3-0 sutures) was examined. Tendons from fresh swine legs (commercially available) served as the biological material. All samples...
-
Anna Zielińska-Jurek prof. dr hab. inż.
OsobyResearch work on photocatalysis by Prof. Anna Zielinska-Jurek started in 2006 at Gdansk University of Technology (Poland), including 3-month research stay at Hokkaido University, Training School “Environmental Applications of TiO2 Photocatalysis” at the University of Oulu in Finland granted by COST Program and Training School “NanoBiophotonics” at the Beckmann Institute, Urbana-Champaign in the USA granted by University of Illinois....
-
Nowoczesne techniki przygotowania próbki do oznaczania analitów organicznych z zastosowaniem chromatografii gazowej. Część II. Aparatura. Modern techniques of preparation of samples for determining organic analytes by gas chromatography. Part II. Instrumentation.
PublikacjaW pracy dokonano przeglądu szerokiego spektrum technik przygotowania próbki ze szczególnym uwzględnieniem technik o charakterze prośrodowiskowym. Opisu technik dokonano pod kątem wykorzystywanych mechanizmów izolacji analitów oraz stosowanych rozwiązań aparaturowych.
-
Determination of antibiotic residues in honey
PublikacjaHoney produced by honeybees is a valuable food product. The presence of xenobiotics in honey may harm its quality and constitute a danger to human health. Antibiotics are commonly applied by beekeepers to eliminate disease among honeybees. Moreover, ubiquitous administration of antibiotics may cause bacteria to become resistant to many drugs and spread antibioticresistant strains of bacteria. Appropriate sample preparation and...
-
Porous material-based sorbent coatings in Solid-phase microextraction technique: Recent trends and future perspectives
PublikacjaThe use of porous materials as sorbents in sample preparation techniques has gained recent scientific attention in the context of developing novel fibers for the Solid-phase microextraction (SPME) technique. SPME requires the appropriate selection of a robust sorbent for successful utilization under variable conditions. A deeper understanding of the nature of newly developed porous SPME coatings and the impact of their structures...
-
Room temperature solvent extraction for simple and fast determination of total concentration of Ca, Cu, Fe, Mg, Mn, and Zn in bee pollen by FAAS along with assessment of the bioaccessible fraction of these elements using in vitro gastrointestinal digestion
Publikacja -
Sensitive method for determination of benzoic acid in beverages and food samples using air–assisted hydrophobic deep eutectic solvent-based dispersive liquid-liquid microextraction
PublikacjaA simple, reliable and rapid air–assisted hydrophobic deep eutectic solvent-based dispersive liquid–liquid microextraction (AA-HDES-DLLME) was developed for analysis of benzoic acid in various beverages and food samples. The final determination stage was performed via UV–visible spectrophotometry. The key parameters (extraction time, HDES type and volume, dispersant volume, pH and sample volume) of the AA-HDES-DLLME method were...
-
Temperture-programmed reduction (H2-TPR) of Ni-Mo2CTx_Mo2Ga2C and Ni-Mo2CTx_Mo3AlC2 catalysts
Dane BadawczeThe dataset includes the data for the preparation of plots illustrating the reduction peaks versus the temperature of the catalyst sample.
-
Aqueous Biphasic Systems Using Chiral Ionic Liquids for the Enantioseparation of Mandelic Acid Enantiomers
Publikacja -
Application of Headspace Solid-phase Microextraction with Poly(1-vinyl-3- Hexylimidazolium Chloride) Polymeric Ionic Liquid Coating using GC - MS to Determine Volatile Fatty Acids in Dairy Wastewater
PublikacjaVolatile fatty acids were determined in this study using headspace solid-phase microextraction (HS-SPME) with a poly(1-vinyl-3-hexylimidazolium chloride) polymeric ionic liquid coated fiber followed by gas chromatography - mass spectrometry. Experimental parameters such as extraction time and temperature, sample volume as well as desorption time and temperature were optimized. Detection limits of the method were in the range of...
-
Green Chromatography: State-of-the-art, Opportunities and Future Perspectives
PublikacjaIt is well known that chromatographic procedures could have a significant impact on the environment if laboratory practice is not in line with the principles of green analytical chemistry (GAC). However, chromatographic techniques have the potential to be greener in all steps of the analysis. The approaches used to make chromatographic separations greener differ depending on the type of chromatographic method. This chapter considers...
-
Comparison of different techniques for extracting Polychlorinated Biphenyls from bottom sediment samples using Isotope Dilution Mass Spectrometry
PublikacjaIn this work, problems that may occur during determination of trace levels of polychlorinated biphenyls in sediment samples are described. The main error sources are connected with extraction of analytes prior to final determination. During model studies, polychlorinated biphenyls have been extracted from sediment reference material (METRANAL 2) with the use of different solvents (dichloromethane, hexane, and toluene); the process...
-
Maximum forces in tendon connections for an anchor without pin in the single-side sample experiment
Dane BadawczeThe main objective of the all study was to assess the load capacity of a new implant device for knotless tendon anastomosis. During this series of experiments the load capacity of the anchoring element without a pin (see figure 1) was examined. Tendons from fresh swine legs (commercially available) served as the biological material. All samples were...
-
Identification and characterization of the Indian Yellow dyestuff and its degradation products in historical oil paint tube by liquid chromatography mass spectrometry
PublikacjaAn analytical protocol for identification of dyes using reversed phase liquid chromatography-mass spectrometry with atmospheric pressure electrospray ionization (LC-ESI/MS) is presented. The developed method has been successfully applied in identification of euxanthic acid and euxanthone, the main components of the Indian Yellow dye in a historical oil paint tube produced by Richard Ain`es, a recognizable French company supplying...
-
Validation of result of STM probe fabrication
Dane BadawczeThe scanning tunneling microscope [1] is a powerful research tool that allows, among other things, to obtain images with atomic resolution. A serious limitation of the described microscope is its limited applicability relating to conductive and semiconductor materials and the reproducibility of measurements depending on the preparation of the measuring...
-
Ocena efektywności monitoringu obiektów inżynierskich za pomocą sieci Bayesa
PublikacjaW swojej pracy autorzy zaproponowali zastosowanie sieci Bayesa do projektowania monitoringu i podejmowania decyzji w działaniach eksploatacyjnych. Ponadto pokazano dwie metody oceny wartości informacji diagnostycznych. Pierwszą z nich jest wartość oczekiwana EVSI (ang. Expected Value of Sample Information), która stanowi podstawę do wyboru spośród alternatywnych obserwacji symptomów zmiennej diagnostycznej. Natomiast drugą metodą...
-
Green, simple analytical method for biogenic amines determination in fruit juice samples using salting-out assisted liquid-liquid microextraction and gas chromatography-mass spectrometry
PublikacjaSalting-out assisted liquid-liquid microextraction (SALLME) was integrated with the derivatization procedure to establish a one-step sample pre-treatment approach for rapid analysis of 14 biogenic amines (BAs) in fruit juices. The methodology consists of salting-out of analytes, derivatization with ethyl chloroformate (ECF), extraction with ethyl acetate (EtAc), and the analysis of the derivatized BAs using gas chromatography-mass...
-
Raman Spectra Measurements for Chemical Identifications - Aspect of Uncertainty Sources and Reduction of Their Effects
PublikacjaRaman spectrometers enable fast and non-contact identification of examined chemicals. These devices measure Raman spectra and compare with the spectra database to identify unknown and often illicit chemicals (e.g. drugs, explosives) usually without any sample preparation. Raman spectra measurements are a challenge due to noise and interferences present outside the laboratories (field applications). The design of a portable Raman...
-
Investigation of vortex assisted magnetic deep eutectic solvent based dispersive liquid–liquid microextraction for separation and determination of vanadium from water and food matrices: Multivariate analysis
PublikacjaA new and simple vortex assisted magnetic deep eutectic solvent dispersive liquid–liquid microextraction procedure (VA-MDES-DLLME) was developed for the determination of vanadium (V) in food and water samples by flame atomic absorption spectrometry (FAAS). In the extraction medium, a bis(acetylpivalylmethane) ethylenediimine (H2APM2en) was used for the complexation of V(V) in sample solution at pH 6. The VA-MDES-DLLME was optimized...
-
Direct injection liquid chromatography-mass spectrometry (DI-LC-MS) analysis for rapid lipidomic profiling of extracellular vesicles
PublikacjaExtracellular vesicles (EVs) are small, spherical particles produced by eukaryotic and prokaryotic cells, surrounded by a bilayer membrane and carrying various bioactive molecules, such as proteins, surface receptors, membrane and soluble proteins, lipids, and nucleic acids. EVs are of substantial interest because of their important roles in cell communication, epigenetic regulation and possible application in disease diagnosis...
-
Methods of assaying volatile oxygenated organic compounds in effluent samples by gas chromatography—A review
PublikacjaThe paper is a review of the procedures for the determination of volatile and semivolatile oxygenated organic compounds (O-VOCs) in effluent samples by gas chromatography. Current trends and outlook for individual steps of the procedure for the determination of O-VOCs in effluents are discussed. The available sample preparation techniques and their limitations are described along with GC capillary columns used for O-VOCs separation...
-
Paweł Burdziakowski dr inż.
Osobydr inż. Paweł Burdziakowski jest specjalista w zakresie fotogrametrii i teledetekcji lotniczej niskiego pułapu, nawigacji morskiej i lotniczej. Jest również licencjonowanym instruktorem lotniczym oraz programistą. Głównymi obszarami zainteresowania jest fotogrametria cyfrowa, nawigacja platform bezzałogowych oraz systemy bezzałogowe, w tym lotnicze, nawodne, podwodne. Prowadzi badania w zakresie algorytmów i metod poprawiających...
-
Discrepancies in determination of biogenic amines in beer samples by reversed phase and hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry
PublikacjaBiogenic amines (BAs) are nitrogenous organic bases occurring mainly in fermented food and beverages as a result of free amino acids bacterial decarboxylation. The reversed phase liquid chromatography (RPLC) and hydrophilic interaction liquid chromatography (HILIC) based methods were compared in terms of usefulness for determination of BAs in beer samples. Analysis of BAs with the use of RPLC method were carried out after their...
-
Rain Gardens LC_MS/MS analysis dataset
Dane BadawczeThis dataset contains the results of samples analysis (target analysis with certified reference materials) using ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS, Shimadzu, Japan).