Wyniki wyszukiwania dla: MEASUREMENT CHANNEL CALIBRATION - MOST Wiedzy

Wyszukiwarka

Wyniki wyszukiwania dla: MEASUREMENT CHANNEL CALIBRATION

Wyniki wyszukiwania dla: MEASUREMENT CHANNEL CALIBRATION

  • A novel calibration method for RSS-based DoA estimation using ESPAR antennas

    Publikacja

    In this paper, we introduce a new calibration method that can successfully be used in direction of arrival (DoA) estimation using electronically steerable parasitic array radiator (ESPAR) antennas and employing power-pattern cross-correlation (PPCC) algorithm, which relies on received signal strength (RSS) values recorded at the antenna output port. Instead of the commonly used two-step approach, during which ESPAR antenna calibration...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • The Boltzmann sequence-structure channel

    Publikacja

    - Rok 2016

    We rigorously study a channel that maps binary sequences to self-avoiding walks in the two-dimensional grid, inspired by a model of protein statistics. This channel, which we also call the Boltzmann sequence-structure channel, is characterized by a Boltzmann/Gibbs distribution with a free parameter corresponding to temperature. In our previous work, we verified experimentally that the channel capacity has a phase transition for...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • ADAPTIVE IDENTIFICATION OF TIME-VARYING IMPULSE RESPONSE OF UNDERWATER ACOUSTIC COMMUNICATION CHANNEL

    Publikacja

    The transmission properties of underwater acoustic communication channel can change dynamically due to the movement of acoustic system transmitter and receiver or underwater objects reflecting transmitted signal. The time-varying impulse response measurement and estimation are necessary to match the physical layer of data transmission to instantaneous channel propagation conditions. Using the correlative measurement method, impulse...

    Pełny tekst do pobrania w portalu

  • IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT

    Czasopisma

    ISSN: 0018-9456 , eISSN: 1557-9662

  • Considerations of Adaptive Digital Communications in Underwater Acoustic Channel

    Publikacja

    Down-link communication (DLC) and air transportable communication (ATAC) buoys as well as autonomous underwater vehicles (AUV) use acoustic links for gathering oceanographic data from underwater monitoring systems. The underwater channel propagation conditions are diverse in nature and require a special adaptive approach to the communication system design. The article presents a methodology for the communication systems design,...

    Pełny tekst do pobrania w portalu

  • Wideband Channel Measurements for Polarised Indoor Off-Body Communications

    Publikacja

    - Rok 2018

    This paper presents the initial results of wideband channel measurements for polarised off-body communication at 5.8 GHz, in an indoor environment. Channel Impulse Response measurements were performed simultaneously for two orthogonal polarisations of the wearable antenna, and repeated for vertical and horizontal orientations of the off-body one. Four types of measurement scenarios were considered in order to investigate the influence...

  • Influence of vision measurement system spatial configuration on measurement uncertainty, based on the example of electric traction application

    Publikacja

    Technical diagnostics plays a significant role in ensuring operational reliability of electrified rail transport. The most critical point in the transmission of electric energy to vehicles is the sliding contact of the current collector with the traction network. For this reason, work is currently being carried on new measuring methods, whose appliance allows for more complete diagnostics of the contact line and current collectors,...

    Pełny tekst do pobrania w portalu

  • MEASUREMENT OF NOISE IN SUPERCAPACITORS

    A developed method and measurement setup for measurement of noise generated in a supercapacitor is presented. The requirements for noise data recording are considered and correlated with working modes of supercapacitors. An example of results of low-frequency noise measurements in commercially available supercapacitors are presented. The ability of flicker noise measurements suggests that they can be used to assess quality of tested supercapacitors.

    Pełny tekst do pobrania w portalu

  • Methane (CH4) calibration set of FTIR spectra

    Dane Badawcze
    open access - seria: DIR-SOFC

    The calibration spectra for CH4 concentration calibration were supplied with this dataset 

  • Phase Transition in a Sequence-Structure Channel

    Publikacja

    - Rok 2015

    We study an interesting channel which maps binary sequences to self-avoiding walks in the two-dimensional grid, inspired by a model of protein folding from statistical physics. The channel is characterized by a Boltzmann/Gibbs distribution with a free parameter corresponding to temperature. We estimate the conditional entropy between the input sequence and the output fold, giving an upper bound which exhibits an unusual phase transition...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Measurements and Measurement Systems [2022/23]

    Kursy Online
    • A. Golijanek-Jędrzejczyk
    • A. Dzwonkowski

    Opis kursu: (np. numer semestru, dla którego przeznaczony jest kurs, cel lub tematyka przedmiotu) IV semestr kierunku Energy Technologies.  Celem kursu jest zapoznanie teoretyczne i praktyczne studentów z podstawowymi i zaawansowanymi metodami pomiarowymi różnych wielkości pomiarowych oraz budową i zasadą działania systemów pomiarowych.  The aim of the course is to introduce theoretical and practical students with basic...

  • A calibration model for gas sensor array in varying environmental conditions

    Abstract: Gas-analyzing systems based on gas sensors, commonly referred to as electronic noses, are the systems which enable the recognition of volatile compounds in their working environment and provide the on-line results of analysis. The most commonly used type of sensors in such systems is semiconductor gas sensors. They are considered to be the most reliable in the long-term applications (more than 1 year), however,...

  • A calibration model for gas sensor array in varying environmental conditions

    Abstract: Gas-analyzing systems based on gas sensors, commonly referred to as electronic noses, are the systems which enable the recognition of volatile compounds in their working environment and provide the on-line results of analysis. The most commonly used type of sensors in such systems is semiconductor gas sensors. They are considered to be the most reliable in the long-term applications (more than 1 year), however,...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Time-Gating method with automatic calibration for accurate measurements of electrically small antenna radiation patterns in Non-Anechoic environments

    Publikacja

    Non-anechoic sites represent a cheap alternative to measurements of antennas in dedicated facilities. However, due to a high noise—from the external EM signal sources and multipath interferences—the quality of radiation patterns obtained in non-anechoic conditions is poor. The characteristics can be corrected using a time-gating method (TGM), which involves filtering of the noise based on temporal analysis of the measured signals....

    Pełny tekst do pobrania w portalu

  • [ITiT] Transmission Channel in Radio Communication Systems - 2023/2024

    Kursy Online
    • S. J. Ambroziak

    {mlang pl} Dyscyplina: informatyka techniczna i telekomunikacja Zajęcia fakultatywne dla doktorantów II roku Prowadzący:  dr hab. inż. Sławomir Ambroziak, prof. PG Liczba godzin: 15 Forma zajęć: wykład {mlang} {mlang en} Discipline: technical informatics and telecommunications Elective course for 2nd-year PhD students Academic teachers: dr hab. inż. Sławomir Ambroziak, prof. PG Total hours of training: 15 teaching hours Course...

  • DESIGN AND CALIBRATION OF ROLLING RESISTANCE TEST TRAILER R2mk.2

    The paper describes construction nad calibration procedures of the rolling resistance test trailer R2 Mk2. The trailer is design to measure rolling resistance of passenger car tyres in various road conditions on trafficked road. The trailer utilizes so called angle method also known as vertical arm method. The paper presents also calibration procedures that are necessary to ascertain good precision of the measurements.

    Pełny tekst do pobrania w portalu

  • Carbon dioxide (CO2) calibration set of FTIR spectra

    Dane Badawcze
    open access - seria: DIR-SOFC

    The calibration spectra for CO2 concentration calibration were supplied with this dataset 

  • Calibration of acoustic vector sensor based on MEMS microphones for DOA estimation

    Publikacja

    A procedure of calibration of a custom 3D acoustic vector sensor (AVS) for the purpose of direction of arrival (DoA) estimation, is presented and validated in the paper. AVS devices working on a p-p principle may be constructed from standard pressure sensors and a signal processing system. However, in order to ensure accurate DoA estimation, each sensor needs to be calibrated. The proposed algorithm divides the calibration process...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Optical method for verification of homogeneity of phantoms for calibration of magnetic resonance

    The primary purpose of this study was to develop a laboratory photonic set-up for characterisation of homogeneity of gel phantoms for calibration of magnetic resonance. In this system, optical coherence tomography allows the detection of micro- and macroscopic heterogeneities of a structure. The set-up was used to perform measurements of agar and agar-carrageenan gels, which are the basis for more complex phantoms for magnetic...

    Pełny tekst do pobrania w portalu

  • Wiktoria Wojnicz dr hab. inż.

    DSc in Mechanics (in the field of Biomechanics)  - Lodz Univeristy of Technology, 2019  PhD in Mechanics (in the field of Biomechanics)  - Lodz Univeristy of Technology, 2009 (with distinction)   Publikacje z listy MNiSW (2009 - ) Wojnicz W., Wittbrodt E., Analysis of muscles' behaviour. Part I. The computational model of muscle. Acta of Bioengineering and Biomechanics, Vol. 11, No.4, 2009, p. 15-21 Wojnicz W., Wittbrodt E., Analysis...

  • A simplified channel estimation procedure for NB-IoT downlink

    Publikacja

    - Rok 2024

    This paper presents a low-complexity channel estimation procedure which is suitable for use in energy-efficient NB-IoT user equipment devices. The procedure is based on the well-established least squares scheme, followed by linear interpolation in the time domain and averaging in the frequency domain. The quality of channel estimation vs. signal-to-noise ratio is evaluated for two channel models and compared with the performance...

    Pełny tekst do pobrania w portalu

  • A simple test for quantum channel capacity

    Publikacja

    Based on state and channel isomorphism we point out that semidefiniteprogramming can be used as a quick test for nonzero one-way quantum channelcapacity. This can be achieved by searching for symmetric extensions of statesisomorphic to a given quantum channel. With this method we provide examplesof quantum channels that can lead to high entanglement transmission but stillhave zero one-way capacity, in particular, regions of symmetric...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Channel Impulse Response Measurements at mmWave Band in Office and Conference Rooms

    Publikacja

    In this paper, the measurements of the channel impulse response at mmWave band in office and conference rooms are described. The central frequency is 27 GHz with a bandwidth of 400 MHz. The description of the used measurement stand and considered environments are presented. The initial analysis of the power delay profile, mean delay, and RMS delay spread allows preliminary conclusions to be drawn that there is a significant impact...

    Pełny tekst do pobrania w portalu

  • Synchro-photogrammetry in the measurement of objects in motion - the case study

    Synchronous photographs and digital photogrammetry methods in a measurement of objects in motion - the experiment. In the following paper, a case study example of a photogrammetric method based on synchronous digital photographs has been presented. This measurement method is an effective solution for tracking of moving objects, dynamic studies and dimensioning of geometry movements. Nowadays, the use of synchronous photography...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • A Simplistic Downlink Channel Estimation Method for NB-IoT

    Publikacja

    This paper presents a downlink channel estimation method intended for a Narrowband Internet of Things (NB-IoT) access link. Due to its low computational complexity, this method is well suited for energy-efficient IoT devices, still providing acceptable reception quality in terms of signal-to-noise (SNR) performance. This paper describes the physical layer of NB-IoT within the scope of channel estimation, and also reviews existing...

    Pełny tekst do pobrania w portalu

  • Selected properties and parameters of radio channel impulse response estimation in ISM 2.4 GHz band

    Publikacja

    - Proceedings of SPIE - Rok 2019

    The article presents experimental research indicating that the impulse response of the communication channel, determined in practice, are not of an universal character, but only represent its approximate value for the frequency on which this measurement was made. Phases for each of the replicas of the measurement signal were determined during the analysis of the received signals in the baseband. Phase changes of individual replicas...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • On the Characteristic Graph of a Discrete Symmetric Channel

    We present some characterizations of characteristic graphs of row and/or column symmetric channels. We also give a polynomial-time algorithm that decides whether there exists a discrete symmetric channel whose characteristic graph is equal to a given input graph. In addition, we show several applications of our results.

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Carbon (II) oxide (CO) calibration set of FTIR spectra

    Dane Badawcze
    open access - seria: DIR-SOFC

    The calibration spectra for CO concentration calibration were supplied with this dataset 

  • Local buckling of composite channel columns

    The investigation concerns local buckling of compressed flanges of axially compressed composite channel columns. Cooperation of the member flange and web is taken into account here. The buckling mode of the member flange is defined by rotation angle a flange about the line of its connection with the web. The channel column under investigation is made of unidirectional fibre-reinforced laminate. Two approaches to member orthotropic...

    Pełny tekst do pobrania w portalu

  • A Surrogate-Assisted Measurement Correction Method for Accurate and Low-Cost Monitoring of Particulate Matter Pollutants

    Publikacja

    - MEASUREMENT - Rok 2022

    Air pollution involves multiple health and economic challenges. Its accurate and low-cost monitoring is important for developing services dedicated to reduce the exposure of living beings to the pollution. Particulate matter (PM) measurement sensors belong to the key components that support operation of these systems. In this work, a modular, mobile Internet of Things sensor for PM measurements has been proposed. Due to a limited...

    Pełny tekst do pobrania w portalu

  • Intelligent Measurement Systems

    Kursy Online
    • J. Wszołek

  • Photonics measurement techniques

    Kursy Online
    • M. Kosowska
    • M. Szczerska
    • P. Listewnik

    start zajęć 10 listopada terminy zajęć  10.11, 17.11, 24.11, 1.12 --> w tych wszystkich dniach godz. 13-14 w sali EA07 i 14-15 w sali EA20 terminy zajęć  18.11, 25.11, 2.12 --> w tych wszystkich dniach godz. 13-15 w sali NE232

  • Intelligent Measurement Systems

    Kursy Online
    • J. Wszołek

  • Accurate Lightweight Calibration Methods for Mobile Low-Cost Particulate Matter Sensors

    Publikacja

    - Rok 2023

    Monitoring air pollution is a critical step towards improving public health, particularly when it comes to identifying the primary air pollutants that can have an impact on human health. Among these pollutants, particulate matter (PM) with a diameter of up to 2.5 μ m (or PM2.5) is of particular concern, making it important to continuously and accurately monitor pollution related to PM. The emergence of mobile low-cost PM sensors...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Estimation of Coherence Bandwidth for Underwater Acoustic Communication Channel

    Publikacja

    A shallow underwater acoustic communication channel is characterized by strong multipath propagation. The signal reaching the receiver consists of a direct waveform and a number of its delayed and suppressed replica. A significant time dispersion of the transmitted signal and selective fading of its spectrum are observed. Coherence bandwidth defines maximal bandwidth, wherein the channel amplitude characteristic remains constant...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Calibration-Free Single-Anchor Indoor Localization Using an ESPAR Antenna

    Publikacja

    In this paper, we present a novel, low-cost approach to indoor localization that is capable of performing localization processes in real indoor environments and does not require calibration or recalibration procedures. To this end, we propose a single-anchor architecture and design based on an electronically steerable parasitic array radiator (ESPAR) antenna and Nordic Semiconductor nRF52840 utilizing Bluetooth Low Energy (BLE)...

    Pełny tekst do pobrania w portalu

  • Mechanical characterization of a gravel column in a calibration chamber operating as a triaxial cell

    Publikacja

    - Rok 2016

    A series of tests considering the behavior of gravel columns was performed. A segment of column with a height of 1 m and a diameter of 0.53 m was modelled in a calibration chamber used as a triaxial cell at three different lateral stress applied. The vertical load transferred on the column head was simulated with steady increase of water pressures in the upper and lower membranes. During the loading the volumetric changes in the...

  • Spatial Calibration of a Dual PTZ-Fixed Camera System for Tracking Moving Objects in Video

    A dual camera setup is proposed, consisting of a fixed (stationary) camera and a pan-tilt-zoom (PTZ) camera, employed in an automatic video surveillance system. The PTZ camera is zoomed in on a selected point in the fixed camera view and it may automatically track a moving object. For this purpose, two camera spatial calibration procedures are proposed. The PTZ camera is calibrated in relation to the fixed camera image, using interpolated...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • The computational methods in the development of a novel multianalyte calibration technique for potentiometric integrated sensors systems

    Publikacja

    - JOURNAL OF SOLID STATE ELECTROCHEMISTRY - Rok 2019

    In recent years, integration and miniaturization of ion-selective electrodes (ISEs) have brought many benefits resulting in the possibility of simultaneous determination of the ions concentration in small volume samples. One of the key problems related to the preparation of potentiometric integrated sensors systems (PISSs) is a calibration procedure due to the necessity to calibrate each particular sensor separately. The main aim...

    Pełny tekst do pobrania w portalu

  • Limitations of WSSUS modeling of stationary underwater acoustic communication channel

    Publikacja

    - HYDROACOUSTICS - Rok 2016

    Performances of underwater acoustic communication (UAC) systems are strongly related to specific propagation conditions of the underwater channel. Due to their large variability, there is a need for adaptive matching of the UAC systems signaling to the transmission properties of the channel. This requires a knowledge of instantaneous channel characteristics, in terms of the specific parameters of stochastic models. The wide-sense...

    Pełny tekst do pobrania w portalu

  • Kalibracja magnetometru magnetorezystancyjnego = Calibration of magnetoresistive magnetometer

    Obiekt o właściwościach ferromagnetycznych zaburza w bliskim otoczeniu równomierność ziemskiego pola magnetycznego. Mierząc indukcję magnetyczną można tego rodzaju obiekt wykryć i zlokalizować. W systemach magnetometrycznych wykrywających ukryte obiekty ferromagnetyczne stosowane są magnetometry transduktorowe, protonowe, pompowane optycznie oraz SQUID. Rozwój technologii półprzewodnikowej pozwala zastosować do tego rodzaju poszukiwań...

  • ECU calibration for gaseous dual fuel supply system in compression ignition engines

    Publikacja

    The dual fuel (DF) combustion mode is proven solution that allows to improve or get at the same level engine performance and reduce toxic compounds in exhaust gases which is confirmed by researchers and end-users. DF combustion mode uses two fuels gaseous fuel as a primary energy source and a pilot quantity of diesel fuel as ignition source. However, in order, to fully take advantage of the potential of the dual fuel mode, DF system...

    Pełny tekst do pobrania w portalu

  • Characteristics of the polarised off-body channel in indoor environments

    Publikacja

    This paper addresses the depolarisation effect in off-body body area networks channels, based on measurements performed at 2.45 GHz in an indoor environment. Seven different scenarios, involving both static and dynamic users, were considered, taking a statistical perspective. The analysis of the cross-polarisation discrimination is performed, as well as the analysis of path loss in co- and cross-polarised channels. Results show...

    Pełny tekst do pobrania w portalu

  • Wideband Off-Body Channel Characteristics with Dynamic User

    Publikacja

    - Rok 2019

    This paper presents the preliminary results of a dynamic off-body channel characterisation study, based on wideband measurements at 5.8 GHz in an indoor environment. The Channel Impulse Response (CIR) was measured for a scenario with the user approaching and departing from the off-body antenna. A CIR deconvolution procedure was performed jointly in two polarisations, and the received signal power, Cross-Polarisation Discrimination...

  • Steady magnetohydrodynamic flow in a diverging channel with suction or blowing

    Publikacja

    - ZEITSCHRIFT FUR ANGEWANDTE MATHEMATIK UND PHYSIK - Rok 2013

    An analysis is made of steady two-dimensional divergent flow of an electrically conducting incompressible viscous fluid in a channel formed by two non-parallel walls, the flow being caused by a source of fluid volume at the intersection of the walls. The fluid is permeated by a magnetic field produced by an electric current along the line of intersection of the channel walls. The walls are porous and subjected to either suction...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Calibration in Metrological Approach

    Publikacja

    - ANALYTICAL LETTERS - Rok 2005

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Calibration and metrological approach.

    Publikacja

    - Rok 2005

    Przedstawiono teraźniejsze podejście do procesu kalibracji. Różnorodność definicji dotyczących pomiarów w chemii analitycznej, nierzadko niekonsekwentnych, może wprowadzić w zakłopotanie. W pracy wyjaśniono pojęcia takie jak: kalibracja, substancje wykorzystywane do kalibracji, walidacja, niepewność materiałów odniesienia. Omówiono również pojęcie spójności pomiarowej w odniesieniu do procesu kalibracji.

  • Sławomir Jerzy Ambroziak dr hab. inż.

    Sławomir J. Ambroziak urodził się w 1982 r. Uzyskał tytuł zawodowy magistra inżyniera w zakresie systemów i usług radiokomunikacyjnych w roku 2008, w 2013 r. uzyskał stopień doktora nauk technicznych w dyscyplinie telekomunikacja, w specjalności radiokomunikacja, natomiast w 2020 r. uzyskał stopień doktora habilitowanego. Od 2008 r. jest pracownikiem Katedry Systemów i Sieci Radiokomunikacyjnych na Wydziale Elektroniki, Telekomunikacji...

  • Equal Baseline Camera Array—Calibration, Testbed and Applications

    Publikacja

    - Applied Sciences-Basel - Rok 2021

    This paper presents research on 3D scanning by taking advantage of a camera array consisting of up to five adjacent cameras. Such an array makes it possible to make a disparity map with a higher precision than a stereo camera, however it preserves the advantages of a stereo camera such as a possibility to operate in wide range of distances and in highly illuminated areas. In an outdoor environment, the array is a competitive alternative...

    Pełny tekst do pobrania w portalu

  • A Method for Underwater Wireless Data Transmission in a Hydroacoustic Channel under NLOS Conditions

    Publikacja

    - SENSORS - Rok 2021

    Wireless data transmission in the hydroacoustic channel under non-line-of-sight (NLOS) propagation conditions, for example, during a wreck penetration, is difficult to implement reliably. This is mostly due to the multipath propagation, which causes a reduction in the quality of data reception. Therefore, in this work an attempt has been made to develop a reliable method of wireless underwater communication test it under the NLOS...

    Pełny tekst do pobrania w portalu