Filtry
wszystkich: 94
Wyniki wyszukiwania dla: CABLE LINE
-
Energy losses reduction in the medium voltage cable line – case study
PublikacjaThe paper presents an analysis of energy losses in a power cable system, which is composed of two 30 kV cable lines. This cable system is located at the seaside holiday area, so the load profile during a year is specific. Energy losses related to reactive power transmission, as well as to currents induced in the sheaths of the cables, are subject to analysis. Measurements were made in the system in order to prepare a computer model...
-
Modelling of MV and HV Cable Lines
PublikacjaOverhead and cable lines are fundamental elements of power systems. Participation of cable lines is smaller and their percentage decreases as voltage is increased. HV cable lines are often built with the use of cables which are composed of coaxial metallic sheaths. Such cables are also often used in MV networks. The sheath may operate in different confgurations. In the case of Polish MV network the sheaths are earthed at both ends....
-
Overheating of underground power cable line due to its partial exposition to solar radiation
PublikacjaCurrent-carrying capacity of underground power cable lines depends, among others, on thermal resistivity of the soil and cables layout: trefoil formation, flat formation with or without spacing. If conditions for heat transfer in the ground are favorable, the current-carrying capacity is relatively high. Therefore, it generates risk of the power cables overheating, if part of the cable line is located vertically in the air, to...
-
Incomplete Cross-Bonding in the MV Line. Experience from the Operation of MV Single Cable Lines
PublikacjaCable lines are one of the basic components of power systems. Medium and high voltage cables mainly comprise a metallic sheath, which is concentric to the main core conductor. There are several operating schemes of such cable lines, which differ in the place of earthing of sheaths and the possible use of the sheaths and/or conductors crossing. The sheaths cross-bonding is typically done in two places of one cable line section,...
-
A new approach to cross-bonding in medium voltage cable lines
PublikacjaThe medium voltage underground cable sheaths are usually bonded and earthed in every substation on the cable route. This results in additional power losses in the sheaths. The paper presents an idea of reducing power losses caused by sheaths cross-bonding. The idea of sheaths cross-connecting only in selected MV/LV substations is given instead of a typical solution, where sheaths cross-bonding requires installing additional joints...
-
Cross-Bonding of MV Cable Lines for Energy Losses Decrease
PublikacjaCurrently, almost all medium voltage cable lines (MV) operate with the return wires earthed at both ends of the cable. Such a way of operation causes that during normal states of operation as well as during disturbances, e.g. short-circuits, in the return wires induce currents whose values mainly depend on the currents flowing in the phase wires. These currents in normal operating states are a source of additional energy losses...
-
Design of power cable lines partially exposed to direct solar radiation – special aspects
PublikacjaPower cable lines are usually buried in the ground. However, in some cases, their ending sections are mounted along the supports of overhead lines. This leads to a situation where the cables are exposed to direct solar radiation and, consequentially, overheat. The paper presents the advanced computer modelling of power cables’ heating, considering their insolation as well as the effect of wind. The temperature and current-carrying...
-
Analysis of Induced Voltages and Power Losses in High Voltage Power Cables for Selected Methods of Cables Sheaths Bonding
PublikacjaPower is increasingly supplied to city centres with 110 kV cable lines. This is a convenient way to supply power, and practically the only one possible in areas of dense urban development. A high-voltage cable contains a coaxial metallic sheath, in which in normal operation and in fault conditions (during short-circuits) significant line-to-earth voltages can be induced, which threatens electric shock and/or damage to the cable’s...
-
AC motor feeding cable consequences on EMC performance of ASD
PublikacjaHigh level of conducted EMI emissions of adjustable speed drives (ASD) is one of the most difficult problems in contemporary applications. Many investigations are carried out in order to find more effective methods allowing to predict this emission at early stage of design, and therefore to predict adequate countermeasures. This paper deals with the method which allows to estimate by simulation the influence of motor feeding cable...
-
Reference FEM model for SHM system of cable-stayed bridge in Rzeszów
PublikacjaThe paper presents the references model for structural health monitoring system (SHM) of cable-stayed bridge recently constructed in Rzeszów over Wisłok River. The SHM system is design to provide on-line information on the structure state and facilitate its maintenance procedures. The main feature of the SHM system is permanent observation of the dynamic behavior of the bridge with focus on cable vibrations. The paper discusses...
-
The effect of cable duct diameter on the ampacity of high-voltage power cables
PublikacjaThe ampacity of power cables depends, among others, on the conditions of heat dissipation from the cable to the environment. Cables are usually laid directly in the ground, but in some sections, they may be placed in ducts, which adversely affects the ampacity of the cable line. The paper presents heat transfer phenomena for cables installed in pipe-type ducts filled with air. The effect of cable duct diameter on this ampacity...
-
Safety issues referred to induced sheath voltages in high-voltage power cables – case study
PublikacjaLoad currents and short-circuit currents in high-voltage power cable lines are sources of the induced voltages in the power cables’ concentric metallic sheaths. When power cables operate with single-point bonding, which is the simplest bonding arrangement, these induced voltages may introduce an electric shock hazard or may lead to damage of the cables’ outer non-metallic sheaths at the unearthed end of the power cable line. To...
-
Risk of power cables insulation failure due to the thermal effect of solar radiation
PublikacjaLow-voltage, as well as high-voltage power cable lines, are usually buried in the ground. The ampacity of the power cables in the ground mainly depends on the thermal resistivity of the soil, which may vary in a wide range. A common practice in power cable systems performance is to supply them from a pole of an overhead line. If so, a section of the line is located in free air and can be directly exposed to solar radiation. In...
-
Subjective and Objective Quality Evaluation Study of BPL -PLC Wired Medium
PublikacjaThis paper presents results of research on the effectiveness of bi-directional voice transmission in a 6 kV mine cable network using BPL-PLC (Broadband over Power Line - Power Line Communication) technology. It concerns both emergency cable state (supply outage with cable shorted at both ends) and loaded with distorted current waveforms. The narrowband (0.5 MHz–15 MHz) and broadband (two different modes, frequency range of 3 MHz–7.5...
-
Attempt to a Video-Transmission Capability in MV Mine Cable Network Using BPL-PLC Technology
PublikacjaThis article presents and discusses the attempt to transmit video content using the BPL-PLC (Broadband over Power Line - Power Line Communication) technology. It includes simulation results of a specially developed digital transmitter and receiver, dedicated to a given predefined 6 kV mining power cable. The effect of two different transmission modes (2-7 MHz and 3-7.5 MHz) and two types of coupling (capacitive-inductive and induction-inductive),...
-
Quality Evaluation of Voice Transmission Using BPL Communication System in MV Mine Cable Network
PublikacjaThis article presents results of a quality evaluation study, considering voice transmission in a 6 kV medium voltage cable network using the BPL (Broadband over Power Line) communication system. The tests are carried out under real mining conditions for the selected power cable without voltage, earthed at both sides. Such a method of monitoring work conditions is of great importance, especially during a disaster. Power cables are...
-
Effect of solar radiation on current-carrying capacity of PVC-insulated power cables – the numerical point of view
PublikacjaPower cables are usually buried in the soil, which results in their relatively high current-carrying capacity. However, there are cases in which the starting/final section of a cable line runs along a pole of an overhead power line. Power cables can be directly exposed to solar radiation then, and this negatively influences their current-carrying capacity as well as estimated life of the cables’ insulation. An analysis of thermal...
-
Reliability assessment of an OVH HV power line truss transmission tower subjected to seismic loading
PublikacjaThe study focuses on the reliability of a transmission tower OS24 ON150 + 10, an element of an OVH HV power line, under seismic loading. In order to describe the seismic force, the real-life recording of the horizontal component of the El Centro earthquake was adopted. The amplitude and the period of this excitation are assumed random, their variation is described by Weibull distribution. The possible space state of the phenomenon...
-
Voltage variations and their reduction in a rural low-voltage network with PV sources of energy
PublikacjaRenewable sources of energy (RES), especially photovoltaic (PV) micro-sources, are very popular in many countries. This way of clean power production is applied on a wide scale in Poland as well. The Polish legal regulations and tariffs specify that every prosumer in a low-voltage network may feed this network with a power not higher than the maximum declared consumed power. In power networks with RES, the voltage level changes...
-
Secured wired BPL voice transmission system
PublikacjaDesigning a secured voice transmission system is not a trivial task. Wired media, thanks to their reliability and resistance to mechanical damage, seem an ideal solution. The BPL (Broadband over Power Line) cable is resistant to electricity stoppage and partial damage of phase conductors, ensuring continuity of transmission in case of an emergency. It seems an appropriate tool for delivering critical data, mostly clear and understandable...
-
Subjective Quality Evaluation of Speech Signals Transmitted via BPL-PLC Wired System
PublikacjaThe broadband over power line – power line communication (BPL-PLC) cable is resistant to electricity stoppage and partial damage of phase conductors. It maintains continuity of transmission in case of an emergency. These features make it an ideal solution for delivering data, e.g. in an underground mine environment, especially clear and easily understandable voice messages. This paper describes a subjective quality evaluation of...
-
CFD-based evaluation of current-carrying capacity of power cables installed in free air
PublikacjaEvaluation of current-carrying capacity of power cables and selection of cross-sectional area of their conductors are mainly performed in accordance with requirements of EN, IEC or IEEE standards. However, these standards do not provide all methods of cables installation and location which occur in practice. Thus, in some cases, performance of advanced modeling of various thermal phenomena, affecting power cables current-carrying...
-
Subjective Quality Evaluation of Underground BPL-PLC Voice Communication System
PublikacjaDesigning a reliable voice transmission system is not a trivial task. Wired media, thanks to their resistance to mechanical damage, seem an ideal solution. The BPL-PLC (Broadband over Power Line – Power Line Communication) cable is resilient to electricity stoppage and partial damage of phase conductors. It maintains continuity of transmission in case of an emergency situation, including paramedic rescue operations. These features...
-
Experiment-Based Study of Heat Dissipation from the Power Cable in a Casing Pipe
PublikacjaThe paper deals with the important challenges in terms of electricity transmission by means of underground cable lines. The power cable’s performance is characterized by an ampacity that represents its maximum electric current-carrying capacity. The ampacity of power cables depends on their ability to diffuse the heat generated by the current flow into the environment. In the performed research, the analysis of the efficiency of...
-
Heat Dissipation from the Power Cable in the Casing Pipe
PublikacjaThe current carrying capacity of a power cable determines its ability to carry a specific current and is related to the efficiency of dissipation of heat generated in the cable laid in a specific environment. The studies were conducted in order to determine how the characteristics of the medium around the cable affected its temperature, and thus the ability of the cable to transmit electricity. The experimentation in the lab and...
-
The low-frequency magnetic field emissions on-board of the vessel
Dane BadawczeThe data represents measurement results performed on board of the vessel. The acquired time-waveforms, corresponding to the instantaneous values of the magnetic field (MF) induction were acquired near the cable supplying the bow thruster motor. Data recording of the magnetic field density (MFD) emissions was carried out with a/d converters of the data...
-
Measurements of radiation emission of a portable power bank with a capacity of 5200 mAh
Dane BadawczeThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell. The test setup was configured to measure a portable power bank...
-
Application of Structural Control Systems for the Cables of Cable-Stayed Bridges: State-of-the-Art and State-of-the-Practice
PublikacjaStay cables are one of the key elements of cable-stayed bridges and are characterized by lightweight, low inherent damping, and high flexibility. They are continuously subjected to small-to large-amplitude vibrations due to various types of dynamic loads that may, in the long term, cause fatigue and fracture problems for the cable system, and may eventually compromise the safety of cable-stayed bridges. Thus, several countermeasures...
-
The Laboratory Stand for the Evaluation of Heat Dissipation from the Power Cable in a Casing Pipe
PublikacjaThe current carrying capacity of a power cable determines its efficiency, which depends on its capability to dissipate heat produced inside the cable, as a result of current flow, into the surrounding. The studies were conducted to determine how the characteristics of the medium around the cable affected its temperature and, as a result, its ability to transport electricity. The experimentation in the lab and real measurements...
-
Analysis of passenger car crash with a cable barrier installed with anti-glare screens on a horizontal convex road curve with 400 m radius
PublikacjaHigh-tension cable barriers have been used on roads for a relatively short period compared with other types of road barriers. Hence, there remains a need for further research on various crash scenarios. An important issue is the performance of a cable barrier on a road curve, particularly when a vehicle impacts the convex side of the barrier. To address this issue, the analysis in this study considers a system of anti-glare screens...
-
DETERMINATION OF ADDITIONAL TENSION IN TOWED STREAMER CABLE TRIGGERED BY COLLISION WITH UNDERWATER MOVING OBJECT
PublikacjaThe paper deals with issues connected with the behaviour of a streamer cable towed by a survey seismic vessel when the cable undergoes a strike triggered by collision with an underwater moving object. The consequences of such collisions may be both threat to the life of marine animals or damage to underwater units and large economic losses suffered by vessel owners. The risk of such collisions has increased over the last years...
-
Induced sheath voltages in 110 kV power cables – case study
PublikacjaThis paper considers electric shock hazard due to induced sheath voltages in 110 kV power cables. The purpose of this paper is to find an optimal configuration of the power cable system, taking into account electric shock hazard and ability of the system to transfer maximal power. A computer simulations on a computer model of the local power system, comprising high voltage power cables, were carried out. This model enables to analyse...
-
Position Estimation in Corridors Along the Coupled Mode of Radiating Cables
PublikacjaRadiating cables are mostly used to provide radio communication in tunnels or corridors, but they can also be used to estimate the position of a mobile terminal along the cable. In this paper, a measuring receiver’s position was estimated by measuring the difference in the direct signal’s reception time, which was generated by a transmitter connected to one end of the radiating cable, and the delayed signal retransmitted from another...
-
Optimization of thermal backfill configurations for desired high-voltage power cables ampacity
PublikacjaThe ampacity of high-voltage power cables depends, among others, on their core cross-sectional area as well as thermal resistivity of the thermal backfill surrounding the cables. The cross-sectional area of the power cables’ core is selected according to the expected power to be transferred via the cable system. Usually, the higher the power transfer required, the higher the cross-sectional area of the core. However, the cost of...
-
Effect of soil moisture on current-carrying capacity of low-voltage power cables
PublikacjaOne of the factors affecting current-carrying capacity of underground power cables is the thermal resistivity of soil. Its value in the close proximity of the cable is the most important, and for this reason, in some cases, the local soil is replaced with an another soil type or with a cement-sand mixture. The thermal resistivity of the soil is strongly affected by moisture, and in the case of a cement-sand mixture – as tested...
-
How it audit can help your communications branch company increase effectiveness of using it technologies and contributes to implementation of business
PublikacjaText based on the example of Cable Television Ltd. Co. in Koszalin.
-
Calculation of Induced Sheath Voltages in Power Cables – Single Circuit System versus Double Circuit System
PublikacjaThis paper presents comparison of values of induced sheath voltages in power cable metallic sheaths when one or two cables per phase are used. Calculation of voltages is performed for various phase sequences of the power cables. Three types of the sheaths bonding and earthing are considered. Shock hazard and voltage stress of non-metallic outer sheath of cables are evaluated. The proposed, optimal configuration of the power cable...
-
Cerclage cable augmentation does not increase stability of the fixation of intertrochanteric fractures. A biomechanical study
PublikacjaBackground: Intertrochanteric fractures with a posteromedial intermediate fragment are unstable because of the loss of medial support. Additional fixation with a cerclage is used in subtrochanteric fractures, but not in intertrochanteric fractures. The aim of this biomechanical study is to evaluate whether cerclage fixation improves stability of intertrochanteric fractures. Hypothesis: Our hypothesis is that the cerclage fixation...
-
Numerical studies on the influence of selected construction features and road conditions on the performance of road cable barriers
PublikacjaCable barriers are commonly used on Polish roads, including motorways and local roads. Their main elements are pre-stressed wire ropes, which are usually anchored at two ends in concrete blocks buried in the soil. In this work numerical studies concerning the influence of selected construction features and parameters of the vehicle motion on the performance of cable barriers were performed. Numerical simulations are a useful tool...
-
The Impact of Thermal Stresses on Volume Resistivity: Performance Comparison between TR-XLPE and XLPE Cables
PublikacjaMost failures in electric power cables are attributed to the development of water trees inside the insulating materials. Thus, the development and utilization of Tree Retardant Cross-Linked Polyethylene (TR-XLPE) based cables have recently been given great attention to overcome the treeing issues. TR-XLPE cables use low-density polyethylene compounds suppressing the formation of water trees while retaining excellent electrical,...
-
The Effect of Protrusions on the Initiation of Partial Discharges in XLPE High Voltage Cables
PublikacjaThis paper is focusing on 3D Finite Elements Analysis (FEA) based modelling of protrusions as defects or imperfections in the XLPE high voltage cable. This study is aiming to examine the impact protrusions have on the initiation of partial discharges. Spherical and ellipsoidal protrusions with different sizes at the conductor screen of the high voltage cable is an essential content of this paper. In addition, a spherical gas-filled...
-
Impact of configuration of earth continuity conductor on induced sheath voltages in power cables
PublikacjaIn high voltage power cable systems a problem of induced sheath voltages exist. Due to these voltages electric shock and damage of non-metallic outer sheath of the cables may occur. Exposure to voltage of the outer sheath may be very high in case of earth fault with high value of earth current. In order to reduce induced sheath voltages an earth continuity conductor (conductors) along power cables is applied. Configuration of this...
-
Waves in a short cable at low frequencies, or just hand-waving? What does physics say? (Invited paper)
PublikacjaWe address the question of low-frequency signals in a short cable, which are often considered as waves in engineering calculations. Such an assumption violates several laws of physics, but exact calculations can be carried out via linear network theory.
-
Broadband Modeling of Motor Cable Impact on Common Mode Currents in VFD
PublikacjaExamination of conducted EMI generation and propagation in AC motor drives fed by frequency converter requires to consider parasitic capacitances in converters, motor windings and feeding cables to be taken into account. AC motor winding voltage transients and related common mode currents are significantly correlated with resonance effects occurring in converter's load circuits. Intensity levels of these phenomena depend...
-
Motor Cable Influence on the Conducted EMI Emission of the Converter Fed AC Motor Drive. - Vol. 1
PublikacjaInvestigation of conducted electromagnetic interference in AC motor drives fed by pulse width modulated voltage converters requires considering parasitic capacitances in converters, motor windings and feeding cables to be taken into account. Motor voltage transients and related conducted electromagnetic emission are significantly correlated with resonance effects occurring in load circuits. The levels of intensity of these phenomena...
-
Measurements of radiation emission of a portable power bank with a capacity of 2600 mAh
Dane BadawczeThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell. The test setup was configured to measure a portable power bank...
-
Ampacity of power cables exposed to solar radiation – recommendations of standards vs. CFD simulations
PublikacjaThe aim of the paper is to evaluate the ampacity of a low-voltage single power cable according to: 1) recommendations of the standard IEC 60287, 2) a Computational Fluid Dynamics method, implemented in Ansys software; and comparison of the results obtained for these two cases. Moreover, limitations of recommendations of the above mentioned standard are indicated.
-
The roadway bridge over Vistula River in Plock - design and construction.
PublikacjaThe paper presents the design and construction works of the Roadway Bridge over Vistula River in Plock (Poland), designed by first two paper authors as being the winners of international competition for design oraganized by Polish association of the bridge engineers. Total length of the bridge is 1,200 m; 615 m is the length of main bridge part over the Vistula riverbed, and 585 m is the length of access bridge part over river...
-
Determination of the Bending Properties of Wire Rope Used in Cable Barrier Systems
PublikacjaThis paper presents research on the bending properties of 3 × 7 19-mm wire rope commonly used in road cable barriers. A total of 19 experimental tests were conducted. In addition, two nonlinear 3D numerical models of the wire rope using beam and solid finite elements were developed. Based on these models, four numerical simulations were carried out. The numerical results were validated against the experimental ones and a very good...
-
Impact of thermal backfill parameters on current-carrying capacity of power cables installed in the ground
PublikacjaProper design of power installations with the participation of power cables buried in homogeneous and thermally well-conductive ground does not constitute a major problem. The situation changes when the ground is non-homogeneous and thermally low-conductive. In such a situation, a thermal backfill near the cables is commonly used. The optimization of thermal backfill parameters to achieve the highest possible current-carrying capacity...
-
Modeling of Common Mode Currents Induced by Motor Cable in Converter Fed AC Motor Drives
PublikacjaInvestigation of conducted EMI generation in AC motor fed by pulse width modulated frequency converters requires to consider parasitic capacitances in converters, motor windings and feeding cables to be taken into account. Motor voltage transients and related common mode currents are significantly correlated with resonance effects occurring in load circuits. An analysis of frequency converter load impedance-frequency characteristics...
-
Computer-aided Analysis of Induced Sheath Voltages in High Voltage Power Cable System
PublikacjaThis paper concerns the effect of configuration of high voltage power cables on induced voltages in their metallic sheaths. One, two or three cables per phase and phase sequence of the cables are considered. Computing of the voltages was performed for a normal operation and in case of earth fault. Various ways of the sheaths bonding are considered as well. Shock hazard and voltage stress of non-metallic outer sheath of cables are...
-
Optimum number of actuators to minimize the cross-sectional area of prestressable cable and truss structures
PublikacjaThis paper describes a new computational method for determining the optimum number of actuators to design the optimal and economic cross-sectional area of pin-jointed assemblies based on the conventional force method. The most active members are selected to be prestressed to redistribute stress in the whole structure, resulting in regulating the internal force of bars that face high stress. Reducing stress in critical members allows...
-
The influence of position of the post or its absence on the performance of the cable barrier system
PublikacjaRoad safety barriers are used to increase safety in potentially dangerous places on the roads. They are designed and installed on the roads to prevent any vehicle from getting outside the travelled way or from entering the opposite lane of the road. Barriers, which are used on European roads, have to undergo full scale crash tests according to the EN 1317 standards. Nowadays as a supplement to real crash tests, numerical simulations...
-
Dynamic effect of the vehicle passing under lightweight footbridge.
PublikacjaThe paper describes a numerical study of dynamic response of cable-stayed steel footbridge for a big lorry passing underneath. The footbridge is an existing object crossing Wolska street in Warsaw. The structural model of footbridge was verified by dynamic test loading. A numerical study of a vehicle passing under footbridge is presented. 2D and 3D incompressible flow fields are modeled using sliding mesh in transient CFD computation....
-
Theoretical analysis of the cable-stayed bridge over brda river in Bydgoszcz
PublikacjaThe topic of this article is the numerical analysis carried out for the cable-stayed tram (road) bridge over Brda river in Bydgoszcz. The goal of numerical studies was the verification of project assumptions and construction solutions elaborated by the autonomous team. The bridge calculations were conducted on three independent FEM models The internal forces and the elements effort under different loading schemes were examined....
-
Dynamic Response of the Suspended on a Single Cable Footbridge
PublikacjaThe article presents numerical simulations, dynamic in situ load tests and a structural health monitoring (SHM) system installed in a suspended on a single cable footbridge. Numerical simulations performed prior to construction indicated the possibility of structural dynamics problems, finally confirmed in the course of dynamic test loading. In the dynamic load course the bridge deck developed vibrations displaying accelerations...
-
Inception and Propagation of Electrical Trees in the Presence of Space Charge in HVAC Extruded Cables
PublikacjaThis paper presents the space charge impact on the inception and propagation of electrical trees in cross-linked polyethylene (XLPE) insulation via simulations and experimentation. A 3D finite element analysis (FEA)-based modeling is proposed to simulate electrical trees via a needle embedded on the XLPE insulation. The proposed FEA model demonstrates the influence of the space charge magnitude and polarity on the initiation of...
-
Pylon foundation of a cable stayed bridge at the motorway ring road of Wrocław
PublikacjaThe largest bridge of the motorway ring road of Wroclaw is a cable stayed bridge over the Odra river near Rędzin. Due to hydrogeological conditions of the ground it was not convenient to use standard bored piles of high length. Instead shorter piles were applied with additional improvement by cement injections at the pile toes. This decision was possible by extending ground investigation program and application of numerical modeling...
-
Numerical Analysis of TB32 Crash Tests for 4-cable Guardrail Barrier System Installed on the Horizontal Convex Curves of Road
PublikacjaHorizontal curves are one of the elements of road infrastructure where statistically a relatively high number of accidents have been reported. In the last ten years in Poland approx. 10% of all road accidents happened on horizontal curves of roads and was responsible for approx. 14% of all fatalities on Polish roads. Thus, this issue is important and requires extensive research and proper road safety treatments. One possible measure...
-
Measurements of radiation emission of a portable power bank with a capacity of 10400 mAh
Dane BadawczeThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell (Fig. 1). The test setup was configured to measure a portable power...
-
RESOURCE ALLOCATION IN DAB+ BROADCASTING SYSTEM
PublikacjaWith over two billion receivers operating worldwide, radio transmission is by far the most accessible medium. It has been a part of our lives since the 1920’s and has become one of the most trusted and friendly mass media. Today, its popularity is still strong, despite the outcome of many electronic media. In order to transform the radio into a viable medium of the 21st century, it will have to migrate from analogue to digital...
-
Improving the Survivability of Carrier Networks to Large-Scale Disasters
PublikacjaThis chapter is dedicated to the description of methods aiming to improve the survivability of carrier networks to large-scale disasters. First, a disaster classification and associated risk analysis is described, and the disaster-aware submarine fibre-optic cable deployment is addressed aiming to minimize the expected costs in case of natural disasters. Then, the chapter addresses the improvement of the network connectivity resilience...
-
Cable-stayed bridges. Basic static schemes
PublikacjaThe paper presents an overview of shaping of cable-stayed bridges. Historical background, basic static sketches and overview of selected bridges are included. Selected natural solutions and interesting unrealized projects were presented. Basic ideas and most important principals are discussed. The examples and sketches were given an author's comment. Static diagrams of two pylon structures with three variants of the arrangement...
-
Pedestrian on footbridges, vertical loads and response
PublikacjaThe paper is a synthesis of the experimental and theoretical investigations on dynamics of pedestrian bridges under vertical load The subject is divided into four issues.1) The pedestrian as a vertical dynamic load on footbridges, theoretic load function for walking and crouching.2) Crowd walking on the footbridge - pedestrian flow.3) Vertical lock-in effect.4) Response of the footbridge - numeric and side test results, -...
-
Evaluation of fire hazard in electrical installations due to unfavorable ambient thermal conditions
PublikacjaEvaluation of fire hazard caused by electrical installations is a difficult and important topic, and it limits the possibility of loss of life or health of people, as well as the occurrence of significant property damage. In particular, this hazard was caused by power cables and especially photovoltaic (PV) installations. The authors proved that power cables directly exposed to strong solar radiation are likely to exceed maximum...
-
Experimental and numerical analysis of the modified TB32 crash tests of the cable barrier system
PublikacjaRoad restraint systems, including safety barriers, are one of the means used to improve road safety. Currently, they can be allowed to general use after passing the specific crash tests. However, it is always important and desirable to evaluate their performance under various realistic conditions, which can happen on the roads. In this study, the behaviour of the cable barrier system in impact conditions different than assumed...
-
Original footbridge in Mikolajki, Poland
PublikacjaIn summer 2016, a new footbridge in the town of Mikołajki (Poland) was built, over a stream connecting two adjacent lakes – Talty and Mikołajki. Its modern construction, based on the shape of a DN ice-boat, makes it inique in Poland, and probably in the world as well. This novel and dynamic shape became a significant landmark associated not only with Mikołajki, but also with the whole region of Mazury, as well as with sailing...
-
Analysis of electromagnetic disturbances in DC network of grid connected building-integrated photovoltaic system
PublikacjaThis paper focuses on conducted electromagnetic interference (EMI) emissions and propagation in the DC network of grid connected building integrated photovoltaic (PV) system. The investigated PV system, consists of ten solar panels, cabling and the grid-connected one phase inverter. The EMI simulation model of the real PV system has been developed with the aid of impedance analyzer measurements of solar panels and the DC network...
-
Cable-stayed cantilever structures as an expat of unique application in the construction of a building located in seismic area – an author’s project of multifunctional building in Lisbon, Portugal
PublikacjaThe article presents numerical simulations for the modelling of seismic impact on the structure of unique cantilever cablestayed structure with application of two methods. The Response Spectrum method, in which a spectrum of the structure's responses to an earthquake's impact is generated and the Accelerogram method, in which we generate dynamic load in the form of a diagram of the connection between acceleration and time for...
-
Shape and force control of cable structures with minimal actuators and actuation
PublikacjaShape adjustment and stress control can be considered as one of the effective parameters in prestressed cable structures since such structures are widely constructed nowadays due to their characteristics. The assembly errors and applied loads hugely affect the cables’ nodal positions and stress due to their delicacy. The former could disturb the shape, which affects the appearance and the function of the structure. In contrast,...
-
Assessing vehicle restraint systems on horizontal curves
PublikacjaHorizontal curves, an element of road infrastructure, have a statistically high number of accidents. Considering that horizontal curves in the last ten years have had app. 10% of all road accidents representing app. 14% of all fatalities on Polish roads, the issue is serious and requires more research and proper road safety treatments. Data for 2007 - 2016 show that in the case of accidents on horizontal curves app. 45% of the...
-
Modeling of a Quasi-Resonant DC Link Inverter Dedicated to Common-Mode Voltage and Ground Current Reduction
PublikacjaIn this paper, the modeling methodology of the AC drive system with a Parallel Quasi-Resonant DC Link Inverter (PQRDCLI) is described. A presented modeling approach is an attractive tool used for the effective evaluation of a common-mode (CM) voltage and grounds current reduction methods. Designed models of inverter, induction machine (IM), and cable are simple, thus the methods for parameter extraction are not complicated. Verification...
-
Pounding mitigation of a short-span cable-stayed bridge using a new hybrid passive control system
PublikacjaThis paper investigates the effectiveness of a new hybrid passive control system on the seismic response of an existing steel cable-stayed bridge considering the pounding effect. The proposed hybrid passive control system comprises a seismic isolator and a metallic damper. The bridge is located in a high seismic zone and has suffered several damages including the earthquake-induced pounding damage during the 1988 earthquake....
-
Reliable routing and resource allocation scheme for hybrid RF/FSO networks
PublikacjaSignificant success of wireless networks in the last decade has changed the paradigms of communication networks design. In particular, the growing interest in wireless mesh networks (WMNs) is observed. WMNs offer an attractive alternative to conventional cable infrastructures, especially in urban areas, where the cost of new installations is almost prohibitive. Unfortunately, the performance of WMNs is often limited by the cluttered...
-
Cross-layer mDNS/ARP integration for IEEE 802.11s Wireless mesh Network
PublikacjaPopularization of mobile computing devices created a need for robust, efficient and ubiquitous methods of communication and network access. At the same time, evolution and standardization of Wireless Local Area Network (WLAN) technologies made them an attractive solution for building of complex network systems. Moreover, growing maturity of WLAN standards such as IEEE 802.11 allows for introduction of WLAN architectures other than...
-
Miniature reconfigurable antenna
PublikacjaThis work concerns the design of a miniature, low-profile reconfigurable antenna based on Huygens metamaterial sources for frequency f0 = 2.45 GHz. Two planar Huygens sources were designed consisting of near-field resonators. Sources are excited from a specially designed reconfigurable control system. Thanks to the two PIN diodes, the system can realize two cardioid radiation characteristics with...
-
Numerical crash analysis of the cable barrier
PublikacjaSafety barriers are used to increase road safety. Their basic task is to prevent the errant vehicle from getting off the road in places which are potentially dangerous for vehicle passengers. Barriers, which are used on European roads, must fulfill the requirements of EN 1317 standards by passing appropriate crash tests. Because of their high cost, numerical simulations are increasingly used to evaluate the properties of safety...
-
The conducted immunity test of a power supply unit in accordance with EMC standards
Dane BadawczeThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 150 kHz to 230 MHz are...
-
The magnetic field measurements in selected places of the industrial building
Dane BadawczeThe dataset is part of a comprehensive study on the assessment of the electromagnetic field intensity in a building of an operating industrial plant. Detailed results of magnetic field measurements, carried out in selected places of this building, are presented.
-
LS-DYNA simulations of the impacts of a 38-ton Heavy Goods Vehicle into a road cable barrier
PublikacjaNowadays, more and more attention is being paid to safety on roads and motorways. It is due to the continuous development of road and motorway network and a significant increase of the number of vehicles on roads. To meet the expectations of improving road safety in Poland, the Road Innovations Development (RID) research programme was implemented in 2016. The aim of the RID 3A - Road Safety Equipment (RoSE) project is a comprehensive...
-
Mechanical Strength of MV Ship-switchgear During Fault Arc
PublikacjaIn the paper the analysis of pressure stressed in enclosure during fault arc inside switchgear is pre-sented as well. There is introduced the method based on determining stresses which are sum of tensile stresses (membrane) and deflection stresses. For tensile stresses nalysis the energy method, for unrestrainedly supported rectangular plate, was used. In the further part of the paper, the calculations and measurements results...
-
The conducted immunity test of an AC adaptor in accordance with EMC standards
Dane BadawczeThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the ac adaptor PHILIPS DC power supply SBC 6654. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 150 kHz...
-
Closed Form Constraint Equations Used to Express Frictionless Slip of Multibody Systems Attached to Finite Elements—Application to a Contact between a Double Pendulum and a Beam
PublikacjaThis paper focuses on the numerical modeling of the dynamics of mechanical systems. Robots that can inspect high-voltage lines inspired this research. Their control systems must anticipate potential grab positions appropriately. We intend to formulate equations dedicated to the numerical description of the robot/cable contact. The investigated problem is not straightforward, since parts of the modeled systems are numerically inhomogeneous....
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 3 V
Dane BadawczeThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 1 V
Dane BadawczeThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 10 V
Dane BadawczeThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
The standard radiated immunity test of an astable multivibrator at a normative field strength
Dane BadawczeThe dataset presents a result of measurements that are a part of electromagnetic field immunity tests. The radiated, radio frequency, immunity tests were carried out for a typical astable electronic multivibrator. Tests of immunity of electronic systems to radiated radio frequency (RF) disturbances in the frequency range from 80 MHz to 1 GHz are performed...
-
The radiated immunity test of an astable multivibrator for various supply voltages
Dane BadawczeThe dataset presents a result of measurements that are a part of electromagnetic field immunity tests. The radiated, radio frequency, immunity tests were carried out for a typical astable electronic multivibrator supplied from a power supply with an output voltage of 6V and 7.5 V. Tests of immunity of electronic systems to radiated radio frequency (RF)...
-
The radiated immunity test of an astable multivibrator in the frequency range from 100 MHz to 300 MHz
Dane BadawczeThe dataset presents a result of measurements that are a part of electromagnetic field immunity tests. The radiated, radio frequency, immunity tests were carried out for a typical astable electronic multivibrator. Tests of immunity of electronic systems to radiated radio frequency (RF) disturbances in the frequency range from 100 MHz to 300 MHz were...
-
High Frequency Conducted Emission in AC Motor Drives Fed By Frequency Converters: Sources and Propagation Paths
PublikacjaProvides a concise and thorough reference for designing electrical and electronic systems that employ adjustable speed drives Electrical and electronic systems that employ adjustable speed drives are being increasingly used in present-day automation applications. They are considered by many application engineers as one of the most interfering components, especially in a contemporarily faced industrial environment. This book fills...
-
Service and Path Discovery Extensions for Self-forming IEEE 802.11s Wireless Mesh Systems
PublikacjaWith the rapid growth of the quantity and capabilities of end-user electronic devices, both stationary and mobile, they are employed in increasing number of applications. In this situation, wireless network technologies begin to play a crucial role as networks access technologies, as cable-based solutions tend to be of limited utility in case of easily portable or mobile devices. Resulting development of wireless technologies reached...
-
Cooperation areas between universities and industry - case studies in the area of civil engineering
PublikacjaThe paper describes the areas of cooperation between universities and industry in the area of civil engineering. Presented examples are related to didactics, research grants and commissioned works. On the basis of the authors own experiences the mutual benefits of cooperation in different areas are described. As well as the assessment criteria of the areas of cooperation by the scientific community. The first area of cooperation...
-
The radiated immunity test of an astable multivibrator at over-normative field strengths
Dane BadawczeThe dataset presents a result of measurements that are a part of electromagnetic field immunity tests. The radiated, radio frequency, immunity tests were carried out for a typical astable electronic multivibrator. Tests of immunity of electronic systems to radiated radio frequency (RF) disturbances in the frequency range from 80 MHz to 1 GHz were performed...