Wyniki wyszukiwania dla: INLET%20AIR%20FOGGING
-
Velocity Field Characteristics at the Inlet to a Pipe Culvert
PublikacjaA poorly designed culvert inlet structure causes scouring, which can lead to the collapse of the culvert and significant damage to the neighboring land. A set of laboratory tests was evaluated to examine velocity distribution at the culvert inlet. A three-dimensional acoustic Doppler velocimeterwas used to measure instantaneous flowvelocity upstream of the culvert. The analysis of mean velocities, turbulence strength, and Reynolds...
-
APPLICABILITY OF INLET AIR FOGGING TO MARINE GAS TURBINE
PublikacjaThe dependency of marine gas turbine on the ambient temperature leads to a decrease of the gas turbine power output in arid areas. Very often gas turbine power output demand is high and the power margins originally designed into the driver , has been exhausted. In such circumstances the inlet air fogging is an effective compensation of gas turbine power. In this paper an analysis of inlet air fogging applicability to marine gas...
-
INFLUENCE OF INLET GEOMETRY ON THE EFFICIENCY OF 1MW STEAM TURBINE
PublikacjaThe process of the design of the 1MW steam turbine includes designing the stator and rotor blades, the steam turbine inlet and exit, the casing and the rotor. A turbine that operates at rotation speeds other than 3000 rpm requires a gear box and generator with complex electronic software. This paper analyses the efficiency of eight turbine variants, including seven inlet geometries and three stages of stator as well as an eight...
-
Inlet air fogging of marine gas turbine in power output loss compensation
PublikacjaThe use of inlet air fogging installation to boost the power for gas turbine engines is widely applied in the power generation sector. The application of fogging to mechanical drive is rarely considered in the literature [1]. This paper will cover some considerations relating to its application to gas turbines in ship drive. There is an important evaporative cooling potential throughout the world when the dynamic data is evaluated,...
-
Thermal and Hydrodynamic Phenomena in the Stagnation Zone — Impact of the Inlet Turbulence Characteristics on the Numerical Analyses
PublikacjaOne of the methods of heat transfer enhancement is utilization of the turbulent impinging jets, which were recently applied, for example, in the heat exchangers. Their positive impact on the heat transfer performance was proven, but many questions related to the origin of this impact are still unanswered. In general, the wall-jet interaction and the near-wall turbulence are supposed to be its main reason, but their accurate numerical...
-
Volute scroll as an alternative to guide vanes at inlet to turbine.
PublikacjaW pracy przedstawiono alternatywny sposób zasilania turbin parowych poprzez zastosowanie podwójnej spirali zasilającej. Przedstawiono model jednowymiarowy obliczania przepływu przez spirale oraz zamieszczono wyniki obliczeń typu 3D. Pokazano jak zależy parametr nierównomierności rozkładu prędkości na wylocie od sposobu kształtowania przekroju spiral.
-
Identification of damages in the inlet air duct of a diesel engine based on exhaust gas temperature measurements
PublikacjaThe temperature of the exhaust gas of a diesel piston engine, measured in the characteristic control sections of its thermo-flow system, can be a valuable source of diagnostic information about the technical condition of the elements limiting the working spaces thus separated, including the turbocharging system, but also its fuel supply system and replacement of the medium. In standard marine engine measurement systems equipped...
-
Effects of n-butanol presence, inlet loading, empty bed residence time and starvation periods on the performance of a biotrickling filter removing cyclohexane vapors from air
PublikacjaThis paper presents the results of investigations on the removal of cyclohexane vapors from air using a peat-perlite packed biotrickling filter. Effects of basic process parameters i.e. IL (inlet loading) and EBRT (empty bed residence time) as well as introduction of n-butanol to the treated air stream and starvation periods on the process performance were evaluated. The results show that the introduction of hydrophilic n-butanol...
-
Prediction of Wastewater Quality at a Wastewater Treatment Plant Inlet Using a System Based on Machine Learning Methods
PublikacjaOne of the important factors determining the biochemical processes in bioreactors is the quality of the wastewater inflow to the wastewater treatment plant (WWTP). Information on the quality of wastewater, sufficiently in advance, makes it possible to properly select bioreactor settings to obtain optimal process conditions. This paper presents the use of classification models to predict the variability of wastewater quality at...
-
Evaluation of the significance of the effect of the active cross-sectional area of the inlet air channel on the specific enthalpy of the exhaust gas of a diesel engine using statistics F of the Fisher-Snedecor distribution
PublikacjaThis paper presents the application of Fisher-Snedecor distribution F statistics to assess the significance of the influence of changes in the active cross-sectional area of the inlet air channel (Adol) flow in a diesel engine on the observed diagnostic parameter determined on the basis of measurements of the quick changing exhaust gas temperature in the outlet channel, which is the specific enthalpy of the exhaust gas stream within...
-
Twin volute admission as an alternative inlet configuration for a steam tu- rbine.**2002, 164 s. 155 rys. bibliogr. 14 poz. maszyn. Podwójna spirala zasilająca jako alternatywny wlot do turbiny parowej. Rozprawa doktorska /2002.06.05/. PG, Wydz. Mechaniczny. Promotor: prof. dr hab. inż. R. Puzyrewski.
Publikacja.
-
Research of hydraulic axial piston pump at low ambient temperatures
Dane BadawczePresented data include the results of measurements of oil temperature at the inlet and outlet of the hydraulic pump (theoretical displacement is equal to 16 cm3/rev) , temperature of the heated pump and oil pressure at the inlet and outlet of the pump.
-
Modeling lubricant flow between thrust-bearing pads
PublikacjaInlet temperature is one of the main inputs in all models for the analysis of fluid film bearing performance. At the same time, inlettemperature distribution and also oil velocity distribution at the inlet are the result of flow phenomena in the gap between the bearingpads. These phenomena are complex and in many cases further affected by any special arrangements of forced oil supply to the gapbetween pads. The reason for such...
-
INTENSYFIKACJA WYMIANY CIEPŁA W WYMIENNIKU WĘŻOWNICOWYM Z WYKORZYSTANIEM PRZEGRÓD O RÓŻNEJ GEOMETRII
PublikacjaW pracy zaprezentowano możliwości wykorzystania pasywnej intensyfikacji wymiany ciepła w postaci przegród dla podniesienia efektywności energetycznej wymiennika wężownicowego. Badania zostały przeprowadzone z wykorzystaniem modułowego wymiennika z wężownicą w postaci grzałki elektrycznej. Medium odbierającym ciepło była woda o stałych parametrach cieplnoprzepływowych na wlocie do modułu. Pomiary przeprowadzono dla szerokiego zakresu...
-
Przepustowość przepustu niezatopionego
PublikacjaPodczas przepływu w warunkach niezatopionego wlotu i wylotu w przewodzie przepustu woda tworzyć będzie swobodne zwierciadło. Przepływ bezciśnieniowy w przewodzie przepustu może wystąpić również w warunkach zatopionego wlotu. W pracy porównano wyniki obliczeń przepustowości całego przepustu i samego przewodu o przekroju kołowym i kwadratowym. W warunkach spokojnego ruchu wody, przy braku spiętrzenia na wylocie, o przepustowości...
-
Natural ventilation performance of family building in cold climate during windy days
PublikacjaAdequately designed natural ventilation is the cheapest and easiest way to effectively remove indoor pollutants and keep the fresh air inside a building. A prediction of performance and effectiveness of ventilation in order to determine the design of a ventilation system can provide real and long term cost savings. The paper presents results of performance (air change rate ACH) and effectiveness (CO2 concentration in the breathing...
-
Biotrickling filtration of n-butanol vapors: process monitoring using electronic nose and artificial neural network
PublikacjaBiotrickling filtration is one of the techniques used to reduce odorants in the air. It is based on the aerobic degradation of pollutants by microorganisms located in the filter bed. The research presents the possibility of using the electronic nose prototype combined with artificial neural network for biofiltration process monitoring in terms of reduction in n-butanol concentration and odour intensity of treated air. The study...
-
Natural ventilation performance of family building in cold climate during windless time
PublikacjaIn this paper, the field measurements results are presented on the stack ventilation effect. The paper presents the results of performance (air change rate ACH) natural ventilation for building with inlet gap measured for the transitional season (between heating and summer season). The measurements were performed during a windless time. The house was located in northern Poland, in a cold climate region. The measurement system...
-
Investigation of H2:CH4 plasma composition by means of spatially resolved optical spectroscopy
PublikacjaThe system based on spatially resolved optical emission spectroscopy dedicated for in situ diagnostics of plasma assisted CVD processes is presented in this paper. Measurement system coupled with chemical vapour deposition chamber by dedicated fiber-optic paths enables investigation of spatial distribution of species densities (Hx, H+, CH, CH+) during chemical vapour deposition process. Experiments were performed for a various...
-
Testing an evaporator operation with a concave manifold, condenser temperature 30, evaporator temperature 70 and preheater temperature 60
Dane BadawczeThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a bifurcation manifold, condenser temperature 20 and evaporator temperature 85
Dane BadawczeThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a concave manifold, condenser temperature 30, evaporator temperature 70 and preheater temperature 40
Dane BadawczeThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a trapezoidal manifold, condenser temperature 90 and evaporator temperature 90
Dane BadawczeThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a bifurcation manifold, condenser temperature 20 and evaporator temperature 70
Dane BadawczeThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a rectangular manifold, condenser temperature 30 and evaporator temperature 90
Dane BadawczeThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a trapezoidal manifold, condenser temperature 70 and evaporator temperature 60
Dane BadawczeThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a bifurcation manifold, condenser temperature 20 and evaporator temperature 95
Dane BadawczeThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a bifurcation manifold, condenser temperature 20 and evaporator temperature 90
Dane BadawczeThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
FTIR spectra of gas mixtures from the methanation chamber filled with 50-50wt.% NiO-Al2O3
Dane BadawczeThe dataset includes the FTIR spectra collection of the outlet gas mixtures (CO2, CO, CH4) from reactor chamber filled with 50/50 wt.% NiO-Al2O3 catalyst for perfoming methanation reaction. The inlet gas mixture was composed of 3:1 by vol. H2:CO. Spectra were collected using PerkinElmer FTIR every 1 min.
-
FTIR spectra of gas mixtures from the methanation chamber filled with 25-75wt.% NiO-Al2O3
Dane BadawczeThe dataset includes the FTIR spectra collection of the outlet gas mixtures (CO2, CO, CH4) from reactor chamber filled with 25/75 wt.% NiO-Al2O3 catalyst for perfoming methanation reaction. The inlet gas mixture was composed of 3:1 by vol. H2:CO. Spectra were collected using PerkinElmer FTIR every 1 min.
-
Modelowanie przepływu pary przez okołodźwiękowe wieńce turbinowe z użyciem sztucznych sieci neuronoych
PublikacjaNiniejszy artykuł stanowi opis modelu przepływu pary przez okołodźwiękowe stopnie turbinowe, stworzonego w oparciu o sztuczne sieci neuronowe (SSN). Przedstawiony model neuronowy pozwala na wyznaczenie rozkładu wybranych parametrów w analizowanym przekroju kanału przepływowego turbiny dla rozpatrywanego zakresu wartości ciśnienia wlotowego.
-
FTIR spectra of gas mixtures from the methanation chamber filled with 50-50wt.% NiO-GDC
Dane BadawczeThe dataset includes the FTIR spectra collection of the outlet gas mixtures (CO2, CO, CH4) from reactor chamber filled with 50/50 wt.% NiO-GDC (Gadolinia Doped Ceria 20mol.%Gd2O3) catalyst for perfoming methanation reaction. The inlet gas mixture was composed of 3:1 by vol. H2:CO. Spectra were collected using PerkinElmer FTIR every 1 min.
-
Direct-Ultrasonic Assisted Microextraction Coupled with RTL-GC-FID/GC-MS as a Future Standard Procedure for Monitoring 26 potentially Allergenic Fragrances in Water Samples
PublikacjaThis research topic grew up as a result of awareness of constant anthropogenic and natural input to the environment constituents of personal care products (PCPs) residues. This group of emerging pollutants encompasses a wide range of chemicals, including potentially allergenic fragrance compounds. The aim of the present study was to investigate presence of 26 fragrance allergens in water samples. Simple and rapid methodology based...
-
A numerical analysis of the thermal effects in the jet impingement stagnation zone
PublikacjaMost of the flows occurring in the engineering systems are turbulent and their accurate numerical analysis is still challenging, especially when combined with the heat transfer. One of the methods of heat transfer enhancement is utilization of the turbulent impinging jets, which were recently applied also in the heat exchangers. Their positive impact on the heat transfer performance was proven, but many questions related to its...
-
An experimental investigation on the effect of new continuous core-baffle geometry on the mixed convection heat transfer in shell and coil heat exchanger
PublikacjaIn the article, the authors presented the influence of continuous core-baffle geometry at mixed convection heat transfer in shell and coil heat exchanger. Experiments were carried out for a large power range, i.e. from 100W to 1200W and mass flow rates ranging from 0.01 kg/s to 0.025 kg/s. During the experiments, the mass flow rate of cooling water, the temperature of water at the inlet and outlet as well as the wall temperature...
-
Sequential treatment of landfill leachate by electrocoagulation/aeration, PMS/ZVI/UV and electro-Fenton: Performance, biodegradability and toxicity studies
PublikacjaThis study presents a systematic study on sequential treatment of highly resistant landfill leachate by electrocoagulation (EC)/aeration, sulfate radical advanced oxidation process (SR-AOP) and electro-Fenton (EF). In case of SR-AOP, peroxymonosulfate (PMS) catalyzed by zero valent iron (ZVI) and ultraviolet irradiation (UV) system was developed. Treatment process was optimized in respect to COD removal. Analysis of results revealed...
-
Improving operating efficiency of a gas turboset via cooperation with an absorption refrigerating machine
PublikacjaThe analysis of increase of ambient air temperature entering the compressor on reduction in power output from the turbine and increase fuel use was conduced. For medium size gas turbine operates in winter and summer conditions elementary power and economical values was calculated. Conditions of the determination of turbine inlet air cooling solution (using thermal storage for reduce equipment size) are presented
-
Thermal energy storage using stearic acid as PCM material
PublikacjaThis work presents an experimental study of thermal energy storage by use of PCM. The aim of the study was to establish the influence of different inlet temperature of heat transfer fluid (HTF) and different Reynolds number of HTF on intensity of charging process. The PCM used in this study was stearic acid and water was used as HTF. A copper helical coil mounted in cylindrical container served as a heat transfer surface.
-
Carbon balance of SOFC fueled by biogas mixture at 750 C
Dane BadawczeThe dataset contains the calculated carbon balance for the SOFC fueled by synthetic biogas mixture (60:40 CH4:CO2). The outlet concentration of the gases from SOFC were measured using novel FTIR-based unit.
-
Rational method of grit chamber efficiency determination
PublikacjaAlthough grot chambers are designed with utmost care, they still remain difficuly to control. As concentration of grit is non-uniform, representative measurements of the sand concentration is a very complex issue. In the paper the results of measure,ents performed at WTP in Gdańsk and Gdynia were analyzed. The proposed method to determine grit chambers efficiency is based on comparison of suspension flow in the inlet and flux of...
-
Exergy analysis of a negative CO2 emission gas power plant based on water oxy-combustion of syngas from sewage sludge gasification and CCS
PublikacjaA power cycle with water-injected oxy-combustion (water cycle) is investigated by exergy analysis. It is fueled with syngas (aka. producer gas) from gasification of sewage sludge. The cycle is equipped with a spray-ejector condenser (SEC). CO2 is separated and compressed for transportation and storage. The net delivered electric power is 31% of the fuel exergy. The task efficiency is 39% when the flue gas bleed to gasification...
-
Variational Method of Finding Streamlines in Ring Cascades for Creeping Flows
PublikacjaThis paper presents a new, analytical method of finding streamlinesfor creeping flows inside a ring cascade which is composed of an infinite number of infinitely thin blades. An analytical solution has been obtained through minimisation of a dissipation functional by means of variational calculus method. The necessary condition for optimum of a functional gives the Stokes equation if some additional assumptions are introduced....
-
Comparison of various flow maldistribution quantification methods in mini heat exchangers
PublikacjaThe aim of study is to compare various flow maldistribution quantification methods, using velocity, mass flow rate, pressure, and temperature. An experimentally validated numerical study has been prepared and a heat exchanger with 34 semi-circular channels with a diameter of 3.1 mm has been tested. The minichannels were heated from the bottom with a heat flux of 50, 60, 70, and 80 kW/m2. The cases for various inlet velocities of...
-
DETEKCJA FAL UDERZENIOWYCH W UKŁADACH ŁOPATKOWYCH CZĘŚCI NISKOPRĘŻNYCH TURBIN PAROWYCH
PublikacjaW artykule przedstawiono wyniki numerycznych symulacji okołodźwiękowego przepływu pary przez ostatnie stopnie części niskoprężnej turbiny o mocy 50 MW. Celem przeprowadzonych symulacji była detekcja oraz lokalizacja fali uderzeniowej, występującej dla przyjętej geometrii układu łopatkowego. Przeanalizowano również wpływ zmiany wartości ciśnienia na wlocie do rozpatrywanych stopni turbiny na maksymalną wartość...
-
How much a geometrical model of a honeycomb seal can be simpli ed in the CFD calculation
PublikacjaThis paper presents the inuence of geometry simplication on the results obtained in the computational fluid dynamics simulation. The subject of simulation was part of the honeycomb seal located at the inlet to high pressure part of a steam turbine. There were three different geometrical models assumed in the calculations. First one was two-dimensional case and two others were three dimensional, one with the radius of curvature...
-
Management of low-temperature heat source by ORC aided by additional heat source
PublikacjaThe presented work is aimed at utilisation of waste heat in the manner to produce electricity in ORC installation. Therefore the precondition of the study was to use the waste heat available in the form of a stream of hot water at 90°C. Such low enthalpy heat source is rather insufficient to produce a good quality vapour to feed the ORC turbine. That was the incentive to search for the ways of increasing the temperature of the...
-
Parametric study of fluid flow and heat transfer over louvered fins of air heat pump evaporator
PublikacjaTwo-dimensional numerical investigations of the fluid flow and heat transfer have been carried out for the laminar flow of the louvered fin-plate heat exchanger, designed to work as an air-source heat pump evap- orator. The transferred heat and the pressure drop predicted by simulation have been compared with the corresponding experimental data taken from the literature. Two dimensional analyses of the louvered fins with varying...
-
Revalorisation of the Szewalski’s concept of the law of varying the last-stage blade retraction in a gas-steam turbine
PublikacjaThe article presents the implementations of the free vortex law to the blade of the last stage of a gas-steam turbine. First, a thermodynamic analysis was carried out, determining the parameters at the inlet, then the number of stages of the high and low-pressure part of the turbine was constructed, together with the kinematics and velocity vectors for subsequent stages of the axial turbine. The last step of article was to take...
-
Investigations on mixture preparation for two phase adiabatic pressure drop of R134a flowing in 5 mm diameter channel
PublikacjaThe article presents detailed two-phase adiabatic pressure drops data for refrigerant R134a. Study cases have been set for a mass flux varying from 200 to 400 kg/m2 s, at the saturation temperature of 19.4 ◦C. Obtained experimental data was compared with the available correlations from the literature for the frictional pressure drop during adiabatic flow. Influence of mixture preparation on pressure drop was investigated, for...
-
Effect of small quantities of potassium promoter and steam on the catalytic properties of nickel catalysts in dry/combined methane reforming
PublikacjaCarbon dioxide and methane are two of the principal greenhouse gases. Reduction of their content in the atmosphere is currently the subject of much worldwide research. Dry and combined reforming of methane are effective methods of CO2 and CH4 utilization and production of synthesis gas (syngas) in chemical technology. Testing of catalysts that provide the desired H2/CO ratio and long operation time is one of the critical aspects...
-
Mitigation of the Flow Maldistribution in Minichannel and Minigap Heat Exchangers by Introducing Threshold in the Manifolds
PublikacjaIn the present paper, a detailed numerical investigation has been carried out to analyze the flow maldistribution in 50 parallel rectangular cross-section (1 mm depth and 1 mm width) minichannels and minigap section (1 mm depth and 99 mm width) with rectangular/trapezoidal manifolds in Z-type flow configuration. The author carried out numerical investigation with various mass flowrates, namely 0.05 kg/s, 0.1 kg/s and 0.2 kg/s which...
-
Wind Conditions in Urban Layout – Numerical and Experimental Research
PublikacjaThis paper presents research which compares the numerical and the experimental results for different cases of airflow around a few urban layouts. The study is concerned mostly with the analysis of parameters, such as pressure and velocity fields, which are essential in the building industry. Numerical simulations have been performed by the commercial software Fluent, with the use of a few different turbulence models, including...
-
COMPUTER ANALYSIS OF HYDRAULIC CONDITIONS IN A SANITARY CHAMBER
PublikacjaThis paper presents analysis of hydraulic conditions of sewage flow down the slipway (ramp) in the collecting sanitary chamber connecting 3 collectors on the inlet: ⌀600, ⌀800 and ⌀1400 and one on the outlet ⌀1600 mm, with a maximum difference of elevation 5 m. The mathematical model has been made and hydraulic calculations were carried out in steady flow conditions. Then wastewater surface elevation, energy grade line elevation,...
-
Analysing selection of low-temperature medium for cogeneration micro power plant
PublikacjaThe article analyses the ORC system working with dry and wet low-boiling media which are most frequently used in installations of this type. Two types of cycles were examined, which were the cycle with heat regeneration for dry media: fc72, hfe7100, R227ea, R245fa, R423a and R600a, and the cycle without heat regeneration for wet media: R11, R12, R134a, R718 and 507a. The calculations were performed for the assumed required thermal...
-
Analysing selection of low-temperature medium for cogeneration micro power plant
PublikacjaThe article analyses the ORC system working with dry and wet low-boiling media which are most frequently used in installations of this type. Two types of cycles were examined, which were the cycle with heat regeneration for dry media: fc72, hfe7100, R227ea, R245fa, R423a and R600a, and the cycle without heat regeneration for wet media: R11, R12, R134a, R718 and 507a. The calculations were performed for the assumed required thermal...
-
Preliminary design of the last stage of supercritical steam turbine and proposition of anti-erosion coating for blades surface
PublikacjaIn this article a preliminary design of the last stage of supercritical steam turbine has been presented. A computational model of supercritical thermal cycle has been created in order to determine steam parameters at the stage inlet and outlet. The model was based on the structure of German coal-fired power plant Datteln 4. Further steam-flow parame-ters and dimensions of stator and rotor blades have been calculated analytically....
-
Comparative Analysis of Numerical and Experimental Studies of the Airflow Around the Sample of Urban Development
PublikacjaIn this paper, on the background of a short overview of the recent advances in the field of Environmental Wind Engineering (EWE), a comparison of wind tunnel experiment and numerical simulation for some cases of airflow around an urban layout have been reported. The purpose of the study is quantitative and qualitative comparison of measurements in the wind tunnel as well as numerical simulation using Ansys Fluent software. The...
-
A conceptual design and numerical analysis of the mixerless urea-SCR system
PublikacjaIn the present study, an innovative design of the urea-selective catalytic reduction (SCR) system without conventional mixing elements was developed. The aim was to obtain a high degree of urea decomposition, and uniform ammonia distribution at the inlet to the catalyst, while minimising the liquid film deposition and keeping the compact design. The concept of the design was based on creating high turbulences and elongating...
-
Numerical Model of the Aortic Valve Implanted Within Real Human Aorta
PublikacjaCardiovascular system diseases are the main cause of deaths in developed and developing countries. The main reasons are myocardial infarction, heart failure, stroke and valvular diseases. These are caused mainly by arteriosclerosis. The valvular diseases involve a significant burden for the health care system and their frequency is rising with the patient age. This work describes the tools and numerical models appropriate for modeling...
-
Fluid Mechanics and Hydraulics EE Msc sem. I r.a. 22/23
Kursy OnlineBasic definitions. Physical properties of liquids. Forces acting on fluids. Hydrostatics - basic equations. Pressure on a flat and curved wall. Buoyancy. Archimedes' law. Balance of submerged bodies. The balance of floating bodies. Hydrodynamics. Hydrodynamic quantities. Continuity equation for the liquid stream. Bernoulli equation. Basic laws of hydrodynamics. Equation of mass behavior, preservation of the amount of motion, Bernoulli's...
-
Fluid Mechanics and Hydraulics EE Msc sem. I r.a. 23/24
Kursy OnlineBasic definitions. Physical properties of liquids. Forces acting on fluids. Hydrostatics - basic equations. Pressure on a flat and curved wall. Buoyancy. Archimedes' law. Balance of submerged bodies. The balance of floating bodies. Hydrodynamics. Hydrodynamic quantities. Continuity equation for the liquid stream. Bernoulli equation. Basic laws of hydrodynamics. Equation of mass behavior, preservation of the amount of motion, Bernoulli's...
-
Effect of asymmetric fluid flow distribution on flow boiling in a microchannel heat sink – An experimental investigation
PublikacjaFlow boiling in microchannels is emerging as an exclusive cooling solution for miniaturized high-power electronic devices alongside having other high heat flux applications. Size miniaturization at microscale strangely increases heat transfer performance as well as flow boiling instabilities. Many flow boiling instabilities are interrelated and result from imperfect hydrodynamic conditions. One of such problems is flow maldistribution among...
-
Validation of atmospheric aerosols sampling in equivalent fractions
PublikacjaPhysical properties and chemical composition of atmospheric aerosols are of extreme importance, in many fields of interest, namely the Environment even with legal implications. Atmospheric sampling poses inherent problems with consequent demands on sampling optimisation, with sampling strategies requiring validation. In this work a study was conducted aiming at validating the collection of atmospheric aerosols in equivalent fractions....
-
Plate heat exchanger with porous structure for potential use in ORC system
PublikacjaThe experimental analysis of passive heat transfer intensification in the case of plate heat exchanger has been carried out. The passive intensification was obtained by a modification of the heat transfer surface, which was covered by a metallic porous microlayer. The experiment was accomplished in two stages. In the first stage the commercial stainless steel gasketed plate heat exchanger was investigated, while in the second one...
-
Plate heat exchanger with porous structure for potential use in ORC system
PublikacjaThe experimental analysis of passive heat transfer intensification in the case of plate heat exchanger has been carried out. The passive intensification was obtained by a modification of the heat transfer surface, which was covered by a metallic porous microlayer. The experiment was accomplished in two stages. In the first stage the commercial stainless steel gasketed plate heat exchanger was investigated, while in the second one...
-
Influence of metallic porous microlayer on pressure drop and heat transfer of stainless steel plate heat exchanger
PublikacjaThe experimental analysis of passive heat transfer intensification in the case of plate heat exchanger has been carried out. On the heat transfer surface of heat exchanger the metallic porous layer was created. The experiment was accomplished in two stages. In the first stage the commercial stainless steel gasketed plate heat exchanger was investigated, while in the second one – the identical heat exchanger but with the modified...
-
Thermodynamic and geometrical characteristics of mixed convection heat transfer in the shell and coil tube heat exchanger with baffles
PublikacjaThe article presents passive heat transfer enhancement method in the form of baffles to increase the energy efficiency of the shell coil heat exchanger. Conducted literature review shows that, despite numer- ous studies, there is little work on the intensification of heat transfer at the shell side. Most of the work focuses on the impact of geometrical parameters of the coil itself. This article successfully proves that it is possible...
-
ECG measurement in the bathtub - getting into the bathtub- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Combined operation of 900MW power plant with the ORC through the bleed steam extraction point and CO2 recovery system
PublikacjaThe work presented here is aimed at utylisation of waste heat in the reference supercritical power plant in the manner to produce electricity in ORC installation. The waste heat is available in the form of a stream of hot water at 90 C, recovered from the exhaust gases in the amount of 200MW. Such low enthalpy heat source is rather insufficient to produce a good quality vapour to feed the ORC turbine. Therefore an original approach...
-
Organic Rankine as bottoming cycle to a combined Brayton and Clausius-Rankine cycle
PublikacjaThis paper presents an enhanced approach, as it will be considered here that the ORC installation could be extra-heated with the bleed steam, a concept presented by the authors. In such way the efficiency of the bottoming cycle can be increased and an amount of electricity generated increases. A thermodynamic analysis and a comparative study of the cycle efficiency for a simplified steam cycle cooperating with ORC cycle will be...
-
Validation of atmospheric aerosols parallel sampling in a multifold device
PublikacjaIn this work, particulate matter was collected using an active sampling system consisting of a PM10 (<10 μm) inlet coupled to a multifold device containing six channels, connected to a vacuum pump. Each channel was equipped with a filter holder fitted with adequately chosen filters. The system was fixed on a metallic structure, which was placed on the roof of the laboratory building, at the Faculty of Sciences, in Lisbon. Sampling...
-
Improved model of isothermal and incompressible fluid flow in pipelines versus the Darcy–Weisbach equation and the issue of friction factor
PublikacjaIn this article, we consider the modelling of stationary incompressible and isothermal one-dimensional fluid flow through a long pipeline. The approximation of the average pressure in the developed model by the arithmetic mean of inlet and outlet pressures leads to the known empirical Darcy–Weisbach equation. Most importantly, we also present another improved approach that is more accurate because the average pressure is estimated...
-
Ultrafast degradation of brilliant cresyl blue under hydrodynamic cavitation based advanced oxidation processes (AOPs)
PublikacjaThe study highlights effectiveness of hydrodynamic cavitation (HC) in the degradation of effluents polluted by Brilliant Cresyl Blue (BCB) dye. Optimal process parameters were cavitation number 0.27, inlet pressure 1.70 bar, temperature 20 °C and pH 7. The efficiency of HC was investigated in combination with other advanced oxidation processes, including the addition of external oxidants (hydrogen peroxide, ozone, and sodium persulfate)...
-
Thermal and hydraulic phenomena in boundary layer of minijets impingement on curved surfaces
PublikacjaPresented work considers flow and thermal phenomena occurring during the single minijet impingement on curved surfaces, heated with a constant heat flux, as well as the array of minijets. Numerical analyses, based on the mass, momentum and energy conservation laws, were conducted, regarding single phase and two-phase simulations. Focus was placed on the proper model construction, in which turbulence and boundary layer modeling...
-
Influence of metallic porous microlayer on pressure drop and heat transfer of stainless steel plate heat exchanger
PublikacjaThe experimental analysis of passive heat transfer intensification in the case of plate heat exchanger has been carried out. The metallic porous layer was created on the heat transfer surface of analyzed unit. The experiment was accomplished in two stages. In the first stage the commercial stainless steel gasketed plate heat exchanger was investigated, while in the second one – the identical heat exchanger but with the modified...
-
The efficiency of turbomachinery in the zero-and three-dimensional approaches
PublikacjaEfficiency of turbomachinery is usually defined using an isentropic process. This approach provides a reliable reference point only when pressure and temperature measurements are available, e.g. at the casing inlet and outlet. In the case of a single stage internal efficiency determination the reference point is difficult. Computational fluid dynamics allows for an exact calculation of values of losses occurring in a turbine...
-
ECG measurement in the bathtub - drl on the outside of the bathtub on one side- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl behind the back - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at buttocks, strengthening 2x smaller, drl at buttocks - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks, drl at the feet - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - one side of the bathtub is grounded, drl outside the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the knees - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, sitting motionless - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the knees, signal amplification x2 - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks, drills at the feet, grounding the bathtub - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, placed on the back - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on the measuring electrodes, drl outside the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on the outside of the bathtub on both sides, measuring electrodes on the front and back of the bathtub- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in the water, measuring electrodes on the sides of the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on one side of the bath mass on the other - the person is moving- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl outside the bathtub on both sides- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in water, front and back measuring electrodes - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, bath simulation - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on measuring electrodes, drl in water - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl at the buttocks - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on one side of the bath, the mass of the system on the other- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - conversation during measurement, electrodes on the sides of the bathtub, drl in water - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in the bathtub, electrodes on the sides of the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl at the knees - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...