Potential changes in an electric field and electrolytic corrosion.
PublikacjaSources have been described of corrosively hazardous electric fields and methods of determination of the corrosion hazard to metal structures caused by electrolytic corrosion. Results of potential and impedance investigations in the field of stray currents flowing out of a tram traction and in the presence of a defined electric field of low frequency have been presented. Uncertainties have been indicated relating to the generally...
-
Prognozowanie krzywej osiadania pala wierconego z iniekcją ciśnieniową pod podstawą
PublikacjaArtykuł jest kontynuacją tematyki autora dotyczącą mechanizmu działania iniekcji ciśnieniowej pod podstawą pala wierconego. W poprzednich publikacjach, autor wykazał, że iniekcja ta w głównej mierze uaktywnia zwiększone opory gruntu wzdłuż pobocznicy pala. Na tej podstawie w niniejszym artykule zaprezentowano procedurę obliczeniową prognozowania krzywą osiadania pala wierconego z iniekcją ciśnieniową pod podstawą. Przedstawiono...
-
Przykłady realizacji i interpretacji wyników sondażowych pomiarów terenowych w czynnych systemach wodociągowych
PublikacjaW pracy przedstawiono przebieg realizacji i rezultaty sondażowych pomiarów terenowych w trzech układach dystrybucji wody o zróżnicowanym przewymiarowaniu sieci wodociągowej. Pomiary przeprowadzono w dążeniu do identyfikacji właściwości (cech) strukturalnych i funkcjonalnych układów po wieloletniej ich eksploatacji. Ustalenia te determinują opracowanie programu realizacji pomiarów dla potrzeb tarowania komputerowego modelu przepływu...
-
Przykłady realizacji i interpretacji wyników sondażowych pomiarów terenowych w czynnych systemach dystrybucji wody
PublikacjaW pracy przedstawiono przebieg realizacji i rezultaty sondażowych pomiarów terenowych w trzech układach dystrybucji wody o zróżnicowanym przewymiarowaniu sieci wodociągowej. Pomiary przeprowadzono w dążeniu do identyfikacji właściwości (cech) strukturalnych i funkcjonalnych układów po wieloletniej ich eksploatacji. Ustalenia te determinują opracowanie programu realizacji pomiarów dla potrzeb tarowania komputerowego modelu przepływu...
-
Retrievable strain measuring system in screw displacement piles - readings and results interpretation problems
PublikacjaStatic load tests on foundation piles are generally carried out in order to determine load – displacement characteristic of the pile. For more detailed information, e.g. force distribution along the shaft, load transfer mechanism and characteristics of soil-structure interaction (unit resistance curves t-z, q-z) additional pile instrumentation is required. Most popular techniques focus on direct concrete strain measurements and...
-
Projektowanie zbiornika na nieczystości ciekłe
PublikacjaW artykule przedstawiono proces projektowania zbiornika podziemnego na nieczystości ciekłe o pojemności ok. 10 m3 posadowionego na gruntach niespoistych (sypkich). Porównano wartości sił wewnętrznych w przypadku skrajnie różnych warunków gruntowych: piasku drobnego o ID = 0,2 oraz żwiru o I D = 0,7. Dodatkowo przeanalizowano wpływ modelu obliczeniowego podłoża na wyniki sił wewnętrznych. Opisano procedurę normową pozwalającą na...
-
Effect of soil moisture on current-carrying capacity of low-voltage power cables
PublikacjaOne of the factors affecting current-carrying capacity of underground power cables is the thermal resistivity of soil. Its value in the close proximity of the cable is the most important, and for this reason, in some cases, the local soil is replaced with an another soil type or with a cement-sand mixture. The thermal resistivity of the soil is strongly affected by moisture, and in the case of a cement-sand mixture – as tested...
-
Model tests of cast-in-place piles formed by using different types of auger
PublikacjaModel tests are still a popular research tool used to observe and determine the mechanisms of pile-soil interaction. Due to the significant scale effect, the results of model tests performed in the 1g system can only be analysed from the qualitative side. This article describes and presents the results of 1g pile model tests carried out for comparative purposes. There were tested the effectiveness and efficiency of various types...
-
Grzegorz Gołaszewski dr inż.
OsobyGrzegorz Gołaszewski, wykładowca na wydziale Elektroniki, Telekomunikacji i Informatyki Politechniki Gdańskiej, informatyk, specjalizujący się w Inżynierii Oprogramowania.Ukończył Wydział ETI PG w roku 2004 ze specjalnością Inżynieria Systemów i Bazy Danych. Pozostał związany z wydziałem po ukończeniu studiów. Uczestniczył w projektach badawczych PIPS oraz ANGEL. W 2017 roku uzyskał stopień doktora w dziedzinie nauk technicznych....
-
Mechanizm współpracy z gruntem pali prefabrykowanych wbijanych w świetle próbnych obciążeń pali oprzyrządowanych
PublikacjaOpis badań i wyniki próbnych obciążeń statycznych dwóch pali prefabrykowanych wbijanych oprzyrządowanych w aparaturę do pomiaru rozkładu siły osiowej wzdłuż trzonu pala. Analiza wpływu czasu i procesu wbijania na charakterystykę osiadania pali prefabrykowanych wbijanych. Identyfikacja siły rezydualnej w palu prefabrykowanym wbijanym i jej wpływ na interpretację pomiarów ekstensometrycznych w próbnym obciążeniu pala. Wnioski na...
-
Reduction of Computational Complexity in Simulations of the Flow Process in Transmission Pipelines
PublikacjaThe paper addresses the problem of computational efficiency of the pipe-flow model used in leak detection and identification systems. Analysis of the model brings attention to its specific structure, where all matrices are sparse. With certain rearrangements, the model can be reduced to a set of equations with tridiagonal matrices. Such equations can be solved using the Thomas algorithm. This method provides almost the same values...
-
A new approach to cross-bonding in medium voltage cable lines
PublikacjaThe medium voltage underground cable sheaths are usually bonded and earthed in every substation on the cable route. This results in additional power losses in the sheaths. The paper presents an idea of reducing power losses caused by sheaths cross-bonding. The idea of sheaths cross-connecting only in selected MV/LV substations is given instead of a typical solution, where sheaths cross-bonding requires installing additional joints...
-
The FEM analysis of pressure installation elements after simulated accidental overheating
PublikacjaThe paper presents innovative analysis focused on the safety aspects of existing pressure installation operation after overheating accidents. Results presented here can be applied in decision-making process concerning further operation of existing pressure installation after cooling system failure. In this paper the results of FEM analysis performed for a straight pipe and 90 degrees elbow, made of super duplex stainless steel,...
-
LDFEM analysis of FDP auger installation in cohesive soil
PublikacjaThis paper deals with large deformation finite element (LDFE) preliminary modelling of Full Displacement Pile (FDP) installation in cohesive soil deposit located in Jazowa, Poland. The detailed FDP auger geometry is applied and the drilling process is modelled with full 3D Coupled Eulerian-Lagrangian (CEL) formulation. The total stress approach and elastic-perfectly plastic model with rate-dependent Mises plasticity is used. The...
-
EFFECT OF WORKING FLUID SELECTION ON THERMAL PERFORMANCE OF HEAT EXCHANGER FILLED BY THE POROUS MATERIAL
PublikacjaThermal management of electronics semiconductor technologies that are located i.e. in a novel marine power plants or computer server rooms become very important issue for designers of such systems. Motivation and need for research in development of novel cooling strategies for modern electronics is of paramount importance. Heat exchangers filled by the porous material are a novel research topic in current heat pipe science. The...
-
MultiRegional PCA for leakage detection and localisation in DWDS - Chojnice case study
PublikacjaThis chapter considers pipe leakage detection and localisation in Drinking Water Distribution Systems (DWDS) by using a novel approach the MultiRegional Principal Component Analysis (MR-PCA). The MR-PCA is an extension of well known PCA method. The main idea of MR-PCA consists in designing a number of regional PCA models and analysing their responses caused by the pipe faults. Moreover, DWDS is decomposed into suitable subnetworks...
-
Decision support system for design of long distance heat transportation system
PublikacjaDistrict Heating (DH) systems are commonly supplied using local heat sources. Nowadays, modern insulation materials allow for effective and economically viable heat transportation over long distances (over 20 km). The paper proposes a Decision Support System (DSS) for optimized selection of design and operating parameters of a long distance Heat Transportation System (HTS). The method allows for evaluation of feasibility and effectiveness...
-
Analiza obudowy wykopu dla budynku z kondygnacją podziemną
PublikacjaW pracy poruszono tematykę analizy obudowy wykopu dla budynku z jedną kondygnacją podziemną, zlokalizowanego w gęstej zabudowie śródmiejskiej. Obliczenia przeprowadzono za pomocą dwóch programów obliczeniowych: GEO5 (moduł: Ściana analiza) i Autodesk Robot Structural Analysis Professional. Całość wyników podsumowano, a wnioski sformułowano w odniesieniu do obecnej sytuacji na rynku budowlanym, charakteryzującej się coraz to trudniejszymi...
-
Laboratory research on the influence of swelling clay on the quality of borehole cementing and evaluation of clay-cutting wellbore tool prototype
PublikacjaSwelling clay phenomenon is frequently observed during oil and gas drilling operations and has a significant impact on the quality of cementing procedure. Certain types of clayey minerals increase their volume in contact with water-based drilling fluids. After drilling is completed, borehole remains unsupported and filled with waterbased drilling fluids for several hours, before a casing string is inserted and secured with cement....
-
Annual changes of basic parameters of bottom sediments from the Klodnica River Catchment
PublikacjaThe Klodnica River Catchment is heavily contaminated ecosystem located in area of the Upper Silesia Industrial Region. In this area various forms of human activity can be observed (e.g. mining coal underground, metallurgy, power/heat plants, wastewater discharged directly into the river). The impact of industrial and municipal wastes on this aquatic system causes to changes in the hydrographic network of river and the waters quality. In...
-
Path Loss Analysis for the IoT Applications in the Urban and Indoor Environments
PublikacjaThe Internet of Things (IoT) networks concept implies their presence in a various and untypical locations, usually with a disturbed radio signals propagation. In the presented paper an investigation of an additional path loss observed in an underground environment was described. The proposed measurement locations correspond to the operation areas of rapidly growing narrowband IoT (NBIoT) networks, the ones using the Long Term Evolution...
-
Laboratory assessment of permeability of sand and biopolymer mixtures
PublikacjaLaboratory assessment of permeability of sand and biopolymer mixtures. This research presents a method of creating seepage barriers in a sandy soil using biopolymer additives (biosubstance), which consist of polysaccharides and water. Polysaccharides strongly interact with water to produce a viscous suspension. The paper aims to investigate the infl uence of a biosubstance employed in a highly permeable sandy soil. Amount of the...
-
Airstrip Ground Improvement Works by Blasting Charge Technique and Dredged-Ash Material Mixture
PublikacjaSoil improvement by blasting charge technique is known in geotechnics as one of the efficient and inexpensive method. It can be used in preparing of underground to found road construction and buildings as well. The technique proves usefulness especially when dynamic load is applied. It is because of non-stiff or rather resilient type soil after improvement. In noncohesive or organic soil, blasting charge...
-
Shaft friction from the DMT and direct shear interface tests
PublikacjaThe article presents preliminary attempt to create tri-linear transfer curves for describing pile behaviour under axial loading. Transfer curves would use the parameter measured in dilatometer test, particularly a constrained modulus MDMT. The proposed method is based on concrete rough and smooth interface tests performed in a direct shear apparatus. Based on the obtained mobilization curves, relationships were created between...
-
Planning, Configuration and Usefulness of Microseismic Monitoring on Eastern-Europe Platform – Example from East Pomerania
PublikacjaThe microseismic monitoring is a method of monitoring of fracture propagation during hydraulic fracturing process. The method uses array of geophones to localize micro tremors induced by liquid pumped underground at high rate and pressure. The acquired information helps to optimize fracturing process and prevents fracture growth to aquifer levels. It proved to be useful on several unconventional hydrocarbon reservoirs in the USA....
-
Application of Bayesian Networks in risk diagnostics arising from the degree of urban regeneration area degradation
PublikacjaUrban regeneration as a complex project, generates many extremely specific threats affecting the increase of investment risk. Its unique nature causes that probability parameter, normally applied in the process of risk quantification, is extremely difficult to estimate. Due to lack of historical data urban regeneration related activities are therefore associated with uncertainty. According to the authors, a useful tool for resolving...
-
Application of BN in Risk Diagnostics Arising from the Degree of Urban Regeneration Area Degradation
PublikacjaUrban regeneration as a complex project, generates many extremely specific threats affecting the increase of investment risk. Its unique nature causes that probability parameter, normally applied in the process of risk quantification, is extremely difficult to estimate. Due to lack of historical data urban regeneration related activities are therefore associated with uncertainty. According to the authors, a useful tool for resolving...
-
Inference Mechanisms for Knowledge Management System in E-health Environment
PublikacjaW artykule zaprezentowano badania i ich wyniki osiągnięte w trakcie prac na systemem zarządzania wiedzą dla systemu typu e-health PIPS (ang. Personalised Information Platform for Life and Health Services)Opisano warstwę semantyczną systemu zarządzania wiedzą, a w szczególności skoncentrowano się na silniku wnioskującym.Poddano dyskusji następujące zagadnienia: analizę dostępnych narzędzi wnioskujący i ich zgodności ze standardem...
-
Energy conversion in systems-contained laser irradiated metallic nanoparticles - comparison of results from analytical solutions and numerical methods
PublikacjaThis work introduces the theoretical method of metallic nanoparticles’ (NPs’) heat and mass transfer where the particles are coated on a surface (base), together with considering the case wherein nanoparticles move freely in a pipe. In order to simulate the heat transfer, energy and radiative transfer equations are adjusted to the considered issue. NPs’ properties are determined following the nanofluidic theories, whereas absorption...
-
THE EFFECT OF WOOD DRYING METHOD ON THE GRANULARITY OF SAWDUST OBTAINED DURING THE SAWING PROCESS USING THE FRAME SAWING MACHINE
PublikacjaThe experimental results of the study focused on the effect of drying processes of warm air drying at the temperature of 6580°C and warm air-steam mixture drying at the temperature of 105°C of pine and beech wood to the size of sawdust grains created by cutting using RPW 15M frame saw is presented in the paper. Particle size analysis of dry sawdust was performed using two methods - screening method and optical method based on...
-
Jakub Miler dr inż.
OsobyKariera akademicka: 2000: mgr inż. Wydział ETI, Politechnika Gdańska, praca pt. "Computer system for supporting risk management in a software engineering project", promotor prof. Janusz Górski 2005: dr inż. Wydział ETI, Politechnika Gdańska, rozprawa pt. "A Method of Software Project Risk Identification and Analysis", obroniona z wyróżnieniem, dziedzina nauki techniczne, dyscyplina informatyka, promotor prof. Janusz Górski Zainteresowania...
-
MODELLING OF TRANSIENT FLOW IN STORM SEWERS
PublikacjaThe paper focuses on the assessment of second-order explicit numerical scheme for unsteady flows in sewers. In order to simulate the pressurized flow the 'Preissmann slot' concept is implemented. For simulation of the transcritical flow the original and improved McCormack scheme is used. The calculated results are compared with numerical solutions and laboratory measurements published in the technical literature. Moreover, the...
-
Elastic Fender-Dolphin Interaction for Economic Design of Berthing Dolphins
PublikacjaThe study addresses the question of the possible design benefits when considering the interaction between a modern marine modular rubber fender and a steel tubular pile substructure of a berthing dolphin. Absorption of the berthing kinetic energy of the vessel by a dualelasticity pile-fender berthing system is described in detail using the interactive treatment method (ITM). Application of the ITM is illustrated by a calculative...
-
DETERMINATION OF THE EFFECT OF ENVIRONMENTAL FACTORS ON THE CORROSION OF WATER DISTRIBUTION SYSTEM BASED ON ANALYSIS OF ON-LINE CORROSION MONITORING RESULTS
PublikacjaCorrosion of water distribution system is a significant issue causing problems with quality, safety and continuity of distribution. The changes of corrosion rates of the water distribution systems in Cracow made of carbon steel were investigated by analysis of online corrosion monitoring system results. Corrosion rates were determined using the linear polarization method. The impact of rain, temperatures, conductivity, dissolved...
-
Hydraulic conductivity of a biopolymer treated sand
PublikacjaThis paper presents results of laboratory assessment of creating seepage barriers in a sandy soil using biopolymer additives (bio substance), which consist of polysaccharides and water. Polysaccharides strongly interact with water to produce a viscous suspension. The aim of the conducted work was to investigate the influence of a biosubstance employed in a highly permeable sandy soil. The amount of the biopolymer used in a sample...
-
Some geomechanical properties of a biopolymer treated medium sand
PublikacjaSome geomechanical properties of a biopolymer treated medium sand. This paper presents a laboratory assessment of geomechanical properties of sandy soil improved by biopolymer application. Additives (biosubstance) consist of polysaccharides and water. Biosubstance used in the project was xanthan gum, which comes from bacteria Xanthomonas campestris. Triaxial shear compression tests and unconfi ned compression tests were carried...
-
MATCHED FILTER APPROACH FOR MICROSEISMIC SIGNAL PROCESSING OF REAL DATA FROM EAST POMERANIA SHALE GAS
PublikacjaThe microseismic monitoring is a method of monitoring of fracture propagation during hydraulic fracturing (HF)process. An array of several hundred geophones is placed on the surface to record little ground tremors induced by fracturing process. Filtration and summation of signals from geophones is essential to identify and locate fracturing events from underground. Authors propose a method of matched filtering, that is usually...
-
Wood Moisture-Content Measurement Accuracy of Impregnated and Nonimpregnated Wood
PublikacjaThe influence of the impregnation process of pine wood (Pinus sylvestris L.) samples on the electrical resistance changes and the moisture-content measurement accuracy is presented in this paper. In this study, the resistances of impregnated and nonimpregnated green pine timber harvested from northern Poland were compared. An impregnation method based on a vacuum-pressure chamber was used. Copper salts were applied as the impregnated...
-
INFLUENCE OF TIME ON THE BEARING CAPACITY OF PRECAST PILES
PublikacjaOne of the most popular types of foundations in layered subsoil with very differentiated soil shear strengths are precast piles. One of the reasons is a fact that we can well control the driving process during the installation of these piles. The principles of the assessment of bearing capacity and settlements of the piles given by Eurocode 7, concentrate on two main methods, i.e. Static Pile Load Tests (SPLT) and Dynamic Driving...
-
Visual Content Learning in a Cognitive Vision Platform for Hazard Control (CVP-HC)
PublikacjaThis work is part of an effort for the development of a Cognitive Vision Platform for Hazard Control (CVP-HC) for applications in industrial workplaces, adaptable to a wide range of environments. The paper focuses on hazards resulted from the nonuse of personal protective equipment (PPE). Given the results of previous analysis of supervised techniques for the problem of classification of a few PPE (boots, hard hats, and gloves...
-
Przepustowość przepustu niezatopionego
PublikacjaPodczas przepływu w warunkach niezatopionego wlotu i wylotu w przewodzie przepustu woda tworzyć będzie swobodne zwierciadło. Przepływ bezciśnieniowy w przewodzie przepustu może wystąpić również w warunkach zatopionego wlotu. W pracy porównano wyniki obliczeń przepustowości całego przepustu i samego przewodu o przekroju kołowym i kwadratowym. W warunkach spokojnego ruchu wody, przy braku spiętrzenia na wylocie, o przepustowości...
-
Koncepcja stanowiska oraz badania możliwości bezpompowego przetłaczania czynnika w rurce ciepła z pętlą obiegową. Część I - Wstęp-charakterystyka obiegu LHP
PublikacjaBezpompowa cyrkulacja czynnika roboczego występuje w rurkach ciepła z pętlą obiegową (LHP, ang. Loop Heat Pipe). Rurki ciepła oparte na pętli, to urządzenia dwufazowe służące do transportu ciepła, wykorzystujące grawitacyjne i kapilarne siły do wzbudzania obiegu czynnika roboczego. LHP stało się bardzo obiecującym urządzeniem, możliwym do wykorzystania w różnego rodzaju zaawansowanych urządzeniach pracujących naziemnie. W pierwszej...
-
The effect of cable duct diameter on the ampacity of high-voltage power cables
PublikacjaThe ampacity of power cables depends, among others, on the conditions of heat dissipation from the cable to the environment. Cables are usually laid directly in the ground, but in some sections, they may be placed in ducts, which adversely affects the ampacity of the cable line. The paper presents heat transfer phenomena for cables installed in pipe-type ducts filled with air. The effect of cable duct diameter on this ampacity...
-
Computational Fluid Dynamics Simulation of Gas–Liquid Multiphase Flow in T-junction for CO2 Separation
PublikacjaThe article presents the results of a computational fluid dynamics (CFD) analysis of gas-liquid multiphase flow. The simulation was conducted using CFD code and the Euler–Euler approach. The presented study relates to the non–reactive, steady-state, turbulent flow of water and carbon dioxide mixture in a 3D pipe. Separation phenomenon between phases is observed. The solution was obtained using a mixture model. Different values...
-
Determination of Liquid Detergent Pods as a Potential Microplastic Source
PublikacjaWashing pods became a popular way to add detergent to washing machines. Despite the claims about the degradability of the pod film, the sludge in pipes can be observed after the usage of such pods. This study focused on a quantitative and qualitative analysis of washing pod films as a source of microplastic.
-
Risk of power cables insulation failure due to the thermal effect of solar radiation
PublikacjaLow-voltage, as well as high-voltage power cable lines, are usually buried in the ground. The ampacity of the power cables in the ground mainly depends on the thermal resistivity of the soil, which may vary in a wide range. A common practice in power cable systems performance is to supply them from a pole of an overhead line. If so, a section of the line is located in free air and can be directly exposed to solar radiation. In...
-
Subjective Quality Evaluation of Speech Signals Transmitted via BPL-PLC Wired System
PublikacjaThe broadband over power line – power line communication (BPL-PLC) cable is resistant to electricity stoppage and partial damage of phase conductors. It maintains continuity of transmission in case of an emergency. These features make it an ideal solution for delivering data, e.g. in an underground mine environment, especially clear and easily understandable voice messages. This paper describes a subjective quality evaluation of...
-
Investigation of Liquid–Gas Flow in a Horizontal Pipeline Using Gamma-Ray Technique and Modified Cross-Correlation
PublikacjaThis article presents the application of the radioisotope absorption method in the study of two-phase water–air flow in a horizontal pipe. The measurement principle and the test stand are briefly described. The main part of the article presents the signal analysis methods applied to data obtained from scintillation detectors. Because these signals are mostly stochastic waveforms, they were analyzed statistically using the cross-correlation...
-
Green Approaches in Rubber Recycling Technologies: Present Status and Future Perspective
PublikacjaAs a consequence of massive production and consumption of rubbers, rubber blends, and rubber composites for myriad applications, elastomeric products have enormously accumulated and become an environmental threat. The disposal and burning of rubber wastes have been banned because of environmental and economic reasons. By contrast, a great deal of attention has been directed toward strategies enabling recycling and reuse of rubbers....
-
New Trends in Sample Preparation Techniques for the Analysis of the Residues of Pharmaceuticals in Environmental Samples
PublikacjaPharmaceutical residues in the environment is a field of special interest due to the adverse effects to either human health or aquatic and soil environment. Pharmaceuticals have been already detected in underground, surface and wastewaters, soils, manure and sediments. The growing awareness of environmental pollution arising from human activity forces the need for their comprehensive determination. Environmental samples are complex...