Publikacje
Filtry
wszystkich: 482
Katalog Publikacji
Rok 2015
-
ALD thin ZnO layer as an active medium in a fiber-optic Fabry–Perot interferometer
Publikacja -
Enhanced capacitance of composite TiO2 nanotube/boron-doped diamond electrodes studied by impedance spectroscopy
Publikacja
Rok 2014
-
Anatomy of Noise in Quantitative Biological Raman Spectroscopy
Publikacja -
Local impedance imaging of boron-doped polycrystalline diamond thin films
Publikacja -
Performance Analysis of the "Intelligent" Kirchhoff-Law–Johnson-Noise Secure Key Exchange
Publikacja -
Ranking of ecotoxisity tests for underground water assessment using the Hasse diagram technique
PublikacjaThe present study deals with the novel application of the Hasse diagram technique (HDT) for the specific ranking of ecotoxicity tests capable of assessment of underground water quality. The area studied is a multi-municipal landfill in the northern Poland. The monitoring network of the landfill constitutes of 27 piezometers for underground water monitoring and two observation points at surface water courses. After sampling, chemical...
-
Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
Publikacja
Rok 2013
-
Amperometric sensing of chemical oxygen demand at glassy carbon and silicon electrodes modified with boron-doped diamond
Publikacja -
Application of Infrared Thermography to Non-Contact Testing of Varistors
Publikacja -
Electrochemical oxidation of sulphamerazine at boron-doped diamond electrodes: Influence of boron concentration
Publikacja -
Klawiatura ekranowa dla osób posługujących się jedną kończyną górną
Publikacjartykuł prezentuje układ symboli na klawiaturze wirtualnej dedykowanej osobom niepełnosprawnym posługującym się jedną kończyną górną. Rozmieszczenie znaków zostało ustalone na podstawie przeprowadzonej analizy częstotliwości występowania poszczególnych liter w języku polskim. Uwzględniono również najczęściej występujące pary liter, a odpowiadające im klawisze ułożono blisko siebie. Zaproponowany kształt klawiatury jest wynikiem...
-
Role of nitrogen in optical and electrical band gaps of hydrogenated/hydrogen free carbon nitride film
PublikacjaWe report the optical and electrical band gap energy of amorphous hydrogenated carbon nitride (a-HCNx) and carbon nitride (a-CNx) as a function of nitrogen concentration (N/C). The optical band gap of a-HCNx and a-CNx films has been determined by means of Ellipsometry and UV-VIS. Both optical and electrical band gaps increase with elevated nitrogen concentration. Experimentally obtained electrical band gap is compared with the...
Rok 2012
-
A microcontroller system for measurement of three independent components in impedance sensors using a single square pulse
PublikacjaOpracowano nową metodę pomiaru w dziedzinie czasu i wyznaczania trzech składowych elementów modelu czujnika impedancyjnego oraz zaimplementowano ją w inteligentnym czujniku impedancji sterowanym 8-bitowym mikrokontrolerem. Metoda bazuje na pobudzeniu dzielnika napięciowego składającego się z rezystora pełniącego funkcję konwertera prąd na napięcie i z czujnika impedancji pojedynczym impulsem prostokątnym o czasie trwania T bezpośrednio...
-
Application of BDD thin film electrode for electrochemical decomposition of heterogeneous aromatic compounds
PublikacjaThe aim of the presented study is to investigate the applicability of electrochemical oxidation of aromatic compounds containing heteroatoms, e.g. waste from production of pesticides or pharmaceutics, at a borondoped diamond (BDD) electrode. The BDD electrodes were synthesized by microwave plasma enhanced chemical vapour deposition (MW PE CVD). Investigation of the electrode surface by optical microscopy and scanning electron microscopy...
-
Determination of chemical oxygen demand (cod) at boron-doped diamond (bdd) sensor by means of amperometric technique
PublikacjaA boron-doped diamond (BDD) sensor was proposed for effective detection of chemical oxygen demand (COD) by means of amperometric technique. Thin boron doped diamond active sensor layer was deposited on Si wafer and glassy carbon substrate by Microwave Plasma Enhanced Chemical Vapor Deposition (MW PE CVD). The structure of BDD was confirmed by Raman spectra analysis. Broad Raman bands centered at 482 cm-1 and 1219 cm-1 are typical...
-
Effect of mid-frequency discharge assistance on dual-high power impulse magnetron sputtering
Publikacja -
Electrochemical oxidation of ionic liquids at highly boron doped diamond electrodes
Publikacja -
Electrochemical oxidation of ionic liquids at highly boron doped diamond electrodes
PublikacjaUtlenianie elektrochemiczne przy zastosowaniu elektrod diamentowych wysoko domieszkowanych borem (BDD) było badane pod względem przydatności do utylizacji roztworów zawierających ciecze jonowe (ILs). Dwustronne elektrody Si/BDD przygotowano metodą chemicznego osadzania z fazy lotnej wspomaganego plazmą (MW PE CVD). Badanie przy użyciu skaningowej mikroskopii elektronowej (SEM) potwierdziło, że wytworzone warstwy były ciągłe i miały...
-
Evaluation of the fast impedance spectroscopy method in the laboratory measurement system
PublikacjaIn this paper the method for fast impedancespectroscopy of technical objects with very high impedance(|Zx| ≥ 1 GΩ) is evaluated by means of simulation and practicalexperiment. The method is based on excitation of an object, witha square pulse and measurements of voltage and currentresponses with DAQ card. The object impedance spectrum isobtained with use of continuous Fourier transform. Someimprovements of the method concerned...
-
Implementation of constant component filter in measurements of random telegraph signal noise
PublikacjaNoise is generated in all semiconductor devices. The intensity of these fluctuations depends on used elements, manufacturing process, operating conditions and device type. The result noise is a superposition of different kinds of fluctuations like thermal noise, generation-recombination noise, 1/f noise, shot noise and Random Telegraph Signal (RTS) noise. The last one, RTS noise is observed as nonstationary impulse fluctuations....
-
Improving AFM images with harmonic interference by spectral analysis
PublikacjaPrzedstawiono sposób usunięcia zakłóceń pojawiających się na obrazach uzyskiwanych z mikroskopu sił atomowych (AFM). Przybliżono kilka metod stosowanych do redukcji zakłóceń w obrazach. Następnie opisano zidentyfikowane zakłócenia harmoniczne oraz zaproponowany sposób ich znaczącej redukcji. W pracy zamieszczono szereg obrazów uzyskanych z mikroskopu AFM ilustrujących efekty powodowane zakłóceniami oraz skuteczność zaproponowanej...
-
Investigation of Noise-Induced Instabilities in Quantitative Biological Spectroscopy and Its Implications for Noninvasive Glucose Monitoring
Publikacja -
Investigation of Noise-Induced Instabilities in Quantitative BiologicalSpectroscopy and Its Implications for Noninvasive Glucose Monitoring
PublikacjaPrzedstawiono sposób oceny błędów jakie pojawiają się przy estymacji poziomu glukozy we krwi za pomocą pomiarów widm Ramana. Zastosowano nieliniowy algorytm regresji według maszyny wektorów nośnych. Określono jak na wyznaczenie stężenia glukozy we krwi wpływają błędy pomiarów widmach Ramana oraz błędów pomiaru referencyjnego stężenia glukozy podczas etapu kalibracji modelu (etapu uczenia algorytmu maszyny wektorów nośnych). Określono...
-
Low Current Transformer Utilizing Co-Based Amorphous Alloys
PublikacjaMetal oxide surge arresters have been widely used for protection of power system networks against overvoltages due to atmospheric discharges or malfunction of devices connected to the network. During its operation a surge arrester structure is degradated, what can be observed as an increase of a surge arrester leakage current. Paper presents an implementation of a new, high-permeability, Co64Fe4Ni1Si15B14 amorphous alloy as a current...
-
Method and measurement system for DC characteristics measurement of power diodes in very wide current range
PublikacjaW artykule przedstawiono układ pomiarowy do pomiaru charakterystyk stałoprądowych diod. Pomiar przeprowadzany jest metodą impulsową w celu zapewnienia stałej temperatury badanego elementu w trakcie pomiaru. Do zapewnienia odpowiedniej liczby punktów pomiarowych wykorzystano układ zmodyfikowanej drabinki R2R z pojedynczymi kluczami sterującymi.
-
Mikro system zasilania bezprzewodowego
PublikacjaWzrastająca na rynku liczba układów mikrokontrolerów o bardzo niskiej konsumpcji energii elektrycznej umożliwia budowę układów zasilania bezprzewodowego, opartych o układy zbierające energię elektryczną z różnych źródeł występujących w naszym otoczeniu. Obecnie powstające układy wytwarzające energie elektryczną korzystają z jej konwersji m.in. z następujących źródeł: promieniowania słonecznego, energii drgań i wibracji, występujących...
-
Non-destructive inspection of anti-corrosion protective coatings using optical coherent tomography
PublikacjaW artykule przedstawiono zastosowanie optycznej tomografii koherentnej (OCT) do badania antykorozyjnych powłok ochronnych. Omówiono właściwości optycznej interferometrii niskokoherentnej jako zastosowanej metody pomiarowej, opisano budowę pomiarowego systemu OCT, zbudowanego w Katedrze Metrologii i Optoelektroniki WETI PG. Przy pomocy zrealizowanego systemu przebadano grupę powierzchni metalicznych pokrytych różnymi powłokami antykorozyjnymi....
-
Plasma diagnostics of low pressure high power impulse magnetron sputtering assisted by electron cyclotron wave resonance plasma
Publikacja -
Problems of varistor quality assessment during exploitation
PublikacjaVaristors are commonly used elements which protect power supply networks against high-voltage surges or lightning. Therefore, quality and endurance of these elements is important to avoid losses when an expensive laboratory equipment would not be protected from random overvoltages. Additionally, excessive leakage currents generate serious costs due to high energy consumption. The paper presents shortly properties of varistors that...
-
Przenośny analizator impedancji z detektorem fazoczułym
PublikacjaW artykule przedstawiono prototyp analizatora impedancji, w którym zastosowano dwa mikrosystemy AD5933 do wydzielania składowych ortogonalnych sygnałów pomiarowych w zakresie częstotliwości od 0,01 Hz do 1 kHz i detektory fazoczułe dla częstotliwości z przedziału 1 kHz ÷ 100 kHz. Przyjęte rozwiązanie pozwoliło wyeliminować błędy pomiaru argumentu impedancji wprowadzane przez AD5933 w górnym zakresie częstotliwości. Uzyskany błąd...
-
Quality testing methods of foil-based capacitors
PublikacjaKondensatory foliowe są powszechnie stosowanymi elementami pasywnymi w ukłądach zasilania. Dotychczasowe metody oceny ich jakości są długotrwałe oraz zużywają energię. W pracy przedstawiono propozycje szeregu nowych, bardziej efektywnych metod, które mogą być z sukcesem stosowane podczas ich produkcji.
-
Remote Monitoring System for Impedance Spectroscopy using Wireless Sensor Network
PublikacjaThe architecture of a miniaturized impedanceanalyser with wireless communication module for remoteImpedance Spectroscopy (IS) of anticorrosion coatings ondifficult-to-reach objects (e.g. on the steel construction ofthe bridge) is described in this paper. Some practical aspectsof implementation of a Wireless Sensor Network (WSN) arealso discussed. A low scale, middle range, WSN networkcomposed of a Base Station (BS) with a Personal...
-
Self-testing of analog parts of mixed-signal electronic microsystems based on multiple sampling of time responses
PublikacjaW artykule przedstawiono nowe podejście samo-testowania toru analogowego zakończonego przetwornikiem A/C w mieszanych sygnałowo elektronicznych systemach wbudowanych sterowanych mikrokontrolerami. Bazuje ono na nowej metodzie diagnostycznej opartej na przekształceniu transformującym zbiór próbek odpowiedzi czasowej układu badanego na pobudzenie impulsem prostokątnym na rodzinę krzywych identyfikacyjnych umieszczonych w przestrzeni...
-
Spectroscopic and wireless sensor of hematocrit level
PublikacjaAn optical method for hematocrit measurement has been presented. the sensor, designed and developed by authors, consists of spectroscopic set-up controlled by a microcontroller. measurement results are sent via wireless module. experiment has confirmed the ability of the sensor to determine the hematocrit with appropriate measurementaccuracy.
-
Spectroscopic and Wireless Sensor of Hematocrit Level
Publikacja -
Surface Plasmon-Coupled Emission of Rhodamine 110 Aggregates in a Silica Nanolayer
PublikacjaFirst analysis of strong directional surface plasmon-coupled emission(SPCE) of ground-state formed intermolecular aggregates of Rhodamine 110 (R110) insilica nanofilms deposited on silver nanolayers is reported. Until now, the processes ofenergy transport and its trapping due to aggregate formation have not been studied in the presence of SPCE. A new approach to multicomponent systems with weakly and strongly fluorescent centers...
-
System monitorowania wyładowań elektrostatycznych
PublikacjaWystępowanie wyładowań elektrostatycznych prowadzi do powstawania bardzo dużych strat w produkcji lub serwisie w przypadku jego uszkodzenia. W niektórych przypadkach konieczne jest monitorowanie jego występowania w strefie (obszarze) chronionej. W artykule przedstawiono prowadzone prace nad systemem wykrywania wyładowań elektrostatycznych opartym o odbiór i analizę sygnału emisji elektromagnetycznej powstającego w momencie jego...
-
Testowanie jakości warystorów niskonapięciowych
PublikacjaW pracy przedstawiono budowę warystorów, z uwzględnieniem procesów zachodzących w ich strukturach i prowadzących do zmiany ich parametrów elektrycznych oraz wybrane sposoby testowania ich jakości.
-
Usage of Two-Center Basis Function Neural Classifiers in Compact Smart Resistive Sensors
PublikacjaA new solution of the smart resistance sensorwith the Two-Center Basis Function (TCBF) neuralclassifier, for which the resistance sensor is a component ofan anti-aliasing filter of an ADC is proposed. Thetemperature measurement procedure is based on excitationof the filter by square impulses, sampling time response ofthe filter and processing measured voltage values by theTCBF classifier. All steps of the measurement procedure...
-
Wykorzystanie termowizji w badaniach odporności na udary wg EN61000-4-5
PublikacjaPrzedstawiono wyniki badań konstrukcyjnych urządzeń elektronicznych z zastosowaniem kamery podczerwieni do obserwacji obiektu badanego podczas badań odporności na udary napięciowe wykonywane wg normy EN61000-4-5.
Rok 2011
-
A compact smart resistive sensor based on a microcontroller
PublikacjaPrzedstawiono nowe rozwiązanie inteligentnego czujnika rezystancyjnego bazującego na mikrokontrolerze, w którym czujnik rezystancyjny jest elementem składowym filtra anty-aliazingowego przetwornika A/C. Procedura pomiaru temperatury obejmuje pobudzenie filtra dwoma impulsami prostokątnymi o zadanym czasie trwania oraz próbkowanie jego odpowiedzi czasowej. Następnie na podstawie wartości pomierzonych próbek napięcia wyznaczana jest...
-
Acoustic emission for detecting deterioration of capacitors under aging
PublikacjaW pracy przedstawiono wyniki pomiarów kondensatorów foliowych poddanych przyśpieszonemu procesowi starzenia na ramie trwałości. Stwierdzono, że w niektórych typach kondensatorów foliowych istnieje związek między intensywnością sygnału emisji akustycznej mierzonego w kondensatorach po ich wytworzeniu oraz rezystancji izolacji mierzonej po procesie ich starzenia.
-
Application of spectroscopy to the measurement of blood parameters
PublikacjaSpectroscopy is the study of formation and interpretation of the spectra arising from the interactions of all types of radiation on matter, understood as a collection of atoms and molecules. This is a very important department of optics which gives us many opportunities to measure various parameters such as material blood parameters. Among the diseases that are associated significantly with changes in rheological properties of...
-
Characterization of PLZT Thin Films for Fast Electro-Optical Sampling Circuits
PublikacjaW artykule omówiono technologię wytwarzania cienkich warstw wybranych kompozycji ceramik ołowiowo-lantanowo-cyrkonowo-tytanowych, nazywanych ceramikami PLZT. Przedstawiono wyniki badań jakości warstw za pomocą techniki XRD. wyniki pomiaru grubości warstw, ich względnej przenikalności dielektrycznej i współczynnika załamania. Omówiono kierunki dalszych prac.
-
Comparison of effectiveness of gas sensing by low frequency fluctuations in resistance and microbalance quartz gas sensors
Publikacja -
Deposition of thin titanium–copper films with antimicrobial effect by advanced magnetron sputtering methods
Publikacja -
Detection of illicit chemicals by portable Raman spectrometer
Publikacja -
Detection of illicit chemicals by portable Raman spectrometer
PublikacjaThe Raman spectrometers can be built as the portable devices and can be used in various places to detect illicit chemicals. This method has become popular due to deficiency of other fast methods that could be applied against terrorist attacks or could help police at their work. The conception of a portable Raman spectrometer has been presented. The description enclosures presentation of the prepared device and its possible applications...
-
Detekcja gazów za pomocą zjawisk fluktuacyjnych w rezystancyjnych czujnikach gazów
PublikacjaOpracowanie przedstawia problemy wykrywania gazów oraz substancji zapachowych, realizowanych za pomocą układów z czujnikami gazów. Opisano zasady działania tych czujników oraz stosowane układy detekcji. Przedstawiono metodę wykrywania gazów za pomocą analizy zjawisk fluktuacyjnych obserwowanych w rezystancyjnych czujnikach gazów. Proponowaną metodę zastosowano, wykorzystując czujniki dostępne na rynku oraz konstrukcje prototypowe....
-
Diagnosis of fully differential circuits based on a fault dictionary implemented in the microcontroller systems
PublikacjaPrzedstawiono nową koncepcję testera wbudowanego bist przeznaczonego do diagnostyki w pełni różnicowych układów analogowych implementowanych w mikrosystemach mieszanych sygnałowo. w trakcie testowania mierzona jest amplituda i faza wyjściowego napięcia różnicowego. procedura detekcji i lokalizacji uszkodzeń bazuje na słowniku uszkodzeń przechowywanym w pamięci programu mikrokontrolera. korzystną cechą przestrzeni pomiarowej wyznaczonej...