Filters
total: 3449
filtered: 2953
displaying 1000 best results Help
Search results for: BRIDGE LOAD TESTS
-
Pedestrian bridge. Load and response
PublicationW pracy zdefiniowano dynamiczny model obciążenia pieszym w zależności od jego masy, rytmu chodu oraz drgań mostu. Zdefiniowana funkcja obciążenia zaimplementowana do komercyjnego programu MES, pozwala na symulacje dynamicznej odpowiedzi konstrukcji na zadane obciążenie. Przedstawiono dwa przykłady modelu teoretycznego w porównaniu z wynikami badań.
-
Displacement measurements during load testing of railway arch bridge
PublicationThe paper discusses issues concerning load tests carried out on a twin-track, arch railway bridge over the Martwa Wisla river in Gdansk. Currently, it is the bridge with the longest span in its class in Poland. The load-bearing structure consists of three no-hinge arches and an orthotropic deck suspended from them. The studies of the structure assumed the performing of static and dynamic tests. The paper presents the method for...
-
Investigation of stability and limit load of a truss overhead opened bridge
PublicationThe paper presents selected methods of determining stability and limit load of a truss top chord in opened bridges. These methods include linear buckling and non-linear static analysis based on the finite element method and algorithms based on design code procedures. The described methods were tested on an example of a steel footbridge situated in Straszyn. The results of stability analysis are compared. The results of geometrical...
-
DISPLACEMENT MEASUREMENTS DURING LOAD TESTING OF THE RAILWAY ARCH BRIDGE
Publication -
Numerical analysis and in situ tests of the Grot Rowecki Bridge in Warsaw
PublicationThe paper presents the FEM analysis of the reconstructed the Grot-Rowecki Bridge over Vistula river in Warsaw. The bridge has seven spans and consists of two independent structures with the longest spans of 120 m. After reconstruction the bridge is over 10 m wider. The numerical, nonlinear analysis has been con-ducted on a global and local FEM models. These models are defined so as they strictly comply with global structural bridge...
-
Dynamic load tests of piles in non-cohesive soils.
PublicationThe results of investigations of various types of piles, the analysis of dynamic tests carried out recently in Poland and the correlations between the results of dynamic and static tests of piles are presented. Przedstawiono wyniki badań nośności różnych rodzajów pali, analizę badań dynamicznych wykonanych w Polsce w ostatnich latach oraz korelacje pomiędzy wynikami badań statycznych i dynamicznych.
-
Load Tests of the Movable Footbridge Over the Port Canal in Ustka
PublicationThe paper presents the acceptance tests carried out on the open footbridge over the port canal in the Port of Ustka. The steel footbridge construction is created by a single pylon to which a movable truss span is suspended with a theoretical span of 52.3 m. The studies about load test of the object included static and dynamic extortion and measurements. In static tests the ballast was of pallets with concrete blocks. Dynamic studies...
-
The assessment of load-settlement curve for Atlas piles correlated with CPT tests
PublicationRacjonalne stosowanie pali przemieszczeniowych typu Atlas wymaga analitycznej oceny pełnej krzywej obciążenie - osiadanie. W pracy przedstawiono możliwości wykorzystania metody funkcji transformacyjnych t-z (dla pobocznicy) oraz q-z (dla podstawy) dla oceny krzywej osiadania. Jednostkowe graniczne opory na pobocznicy, tmax, oraz pod podstawą, gf, określono na podstawie metody bezpośredniej, wykorzystując opory stożka sondy, qc....
-
Analysis of the cyclic load-unload-reload tests of VALMEX aged fabric
PublicationThe paper presents mechanical response of the VALMEX fabric during the cyclic loading-unloading and re-loading experiments. Two types of the aged material used for nearly 20 years as the roofing of the Forest Opera in Sopot (Poland) have been tested. The results have been separately obtained for the warp and fill di-rections. The comparative analysis has revealed that the material aged in service is more durable in the fill di-rection,...
-
Identification of residual force in static load tests on instrumented screw displacement piles
PublicationOccurrence of the so-called residual force of an unknown value significantly disturbs interpretation of static load tests performed on piles equipped with additional measuring instruments. Screw displacement piles are the piling technology in which the residual force phenomenon is very common. Its formation mechanism is closely related to the installation method of this type of piles, which initiates generation of negative pile...
-
Load capacity of steel-aluminium brackets under static and cyclic laboratory tests
PublicationThe aim of the research is the laboratory investigation of steel-aluminium brackets employed to fasten lightweight curtain walls to building facilities. Static pressure, suction forces, and cyclic loads parallel to end plates (horizontal – to simulate wind influence) were applied in the study. The steel-aluminium brackets were tested on a reinforced concrete substrate made of C30/37 concrete class to simulate the real working conditions....
-
Experimental tests and numerical simulations of full scale composite sandwich segment of a foot- and cycle- bridge
PublicationIn the paper experimental tests and numerical simulations of a full cross-section segment of ultimately designed foot-and cycle-bridge are presented. The experimental tests were conducted on element with length reduced to 3 m and unchanged (target) cross-section dimensions. The external skin of structure is GFRP laminate while internal core is PET foam. Several quasi-static tests were performed using hydraulic cylinder to generate...
-
GB-SAR in the Diagnosis of Critical City Infrastructure—A Case Study of a Load Test on the Long Tram Extradosed Bridge
Publication -
Bearing capacity of piles based on static load tests and calculation principles provided by EN 1997-1
PublicationW artykule scharakteryzowano i przeanalizowano ogólne zalecenia Eurokodu 7 dotyczące wyznaczania nośności pali na podstawie próbnych obciążeń statycznych. Porównano je z zaleceniami dotychczasowej polskiej normy PN-83/B-02482. Przedstawiono kilka przykładów interpretacji rzeczywistych wyników próbnych obciążeń pali według zaleceń wyżej wymienionych dwóch norm wraz z analizą porównawczą.
-
Comparison the heat load as the results of tests on human subject in a hot environment with the results obtained from numerical simulation
Publication -
Sustainable development requires risky decisions - problematic 300 ton overweight transport passing a bridge
PublicationOversize load passages over bridges are one of the research issues related to sustainable development that engineering and scientific teams around the world have to deal with . The article presents the scope of activities that enabled the passage of an oversized vehicle with a total weight of over 300 tons over a reinforced concrete slab. The bridge load capacity is 30 tons. In order to assess the capacity of the bridge, detailed...
-
Application of probabilistic tools to extend load test design of bridges prior to opening
PublicationLoad tests of bridges are widely performed in a large number of countries. Deterministic comparison of measurement results to the theoretical, FEM (finite element method)-based outcomes with possible further calibration is mostly applied. Sometimes, the data collected in the tests are also used to calibrate the reliability factors of bridge structures or their components. This work proposes to complement the stage of the load test...
-
Load test of new European record holder in span length among extradosed type bridges
PublicationThe article presents acceptance load tests of a newly built extradosed MS-3 bridge located along the national road DK-16 near Ostróda (Poland). The structure features significant dimension in European reference scale. It is a new record holder in span length regarding this distinct bridge category. Its length ranges 206 m. Static and dynamic load tests were performed here. The program was extended by entire structural laser scanning...
-
Dynamics of the small-span railway bridge under moving loads
PublicationThe paper presents the results of dynamic analysis of the small-span railway bridge, subjected to an action of moving trains. Numerical simulations were performed using three different load models: series of moving forces, series of moving single-mass and double-mass oscillators. The parameters of the vehicle were taken from the existing EN57 train. The parameters of the bridge were taken from the existing steel span of 10,24 m...
-
Case Study of Old Steel Riveted Railway Truss Bridge: From Material Characterization to Structural Analysis
PublicationThe structural analysis of an old steel riveted railway truss bridge located over the Maruska River on the Działdowo – Olsztyn, Poland railway line is performed in this paper to check its behaviour under today’s railway loads. The mechanical properties of construction steel extracted from the old steel bridge are investigated by tensile tests, impact tests through the Charpy pendulum impact V-notch, and an optical emission spectrometer....
-
Load testing of a suspended footbridge in Radom (Poland)
PublicationThe footbridge in Radom is a suspended bridge of an interesting architectural form. The structure was de-signed for 4 kN/m2 of crowd loading. Dynamic calculations were not included in the design. The structure’s acceptance tests took place on the 14th of October 2016. The behaviour of the footbridge in static testing met the expectations. Unfortunately, as a result of dynamic tests, dangerous behaviour of the footbridge was revealed....
-
Testing of the longest span soil-steel bridge in Europe – new quality in measurements
PublicationThe article describes interdisciplinary and comprehensive diagnostic tests of final bridge inspection and acceptance proposed for a soil – steel bridge made of corrugated sheets, being the European span length record holder (25.74 m). As an effect of an original concept a detailed and precise information about the structure response was collected. The load test design was based on the nonlinear numerical simulations performed by...
-
A 95-Year-Old Concrete Arch Bridge: From Materials Characterization to Structural Analysis
PublicationThe structural analysis of a 95-year-old concrete arch bridge located in Jagodnik (Poland) is performed in this paper, in order to check its behavior under today’s traffic loads. The mechanical properties of both the concrete and the reinforcement are investigated by testing cores and bar stubs extracted from the bridge. Structural analysis confirms that the bridge meets today’s load requirements in terms of bearing capacity, serviceability...
-
Improving the procedure of probabilistic load testing design of typical bridges based on structural response similarities
PublicationThis paper concerns load testing of typical bridge structures performed prior to operation. In-situ tests of a two-span post-tensioned bridge loaded with three vehicles of 38-ton mass each formed the input of this study. On the basis of the results of these measurements, an advanced FEM model of the structure was developed for which the sensitivity analysis was performed for chosen uncertainty sources. Three uncorrelated random...
-
Bridge Non-Destructive Measurements Using a Laser Scanning during Acceptance Testing: Case Study
PublicationOwing to the recent proliferation of inventory works on roads and railways, bridge acceptance tests have increased exponentially. These tests’ results are often misinterpreted owing to the use of various measuring equipment types, rendering integrated interpretation problematic. It is also problematic that adjusting the measurement method is difficult when the structure’s response to load is uncertain. Therefore, it is important...
-
A novel sandwich footbridge - Practical application of laminated composites in bridge design and in situ measurements of static response
PublicationA novel sandwich composite footbridge is presented in the paper, as an example of practical application of laminated composites in civil engineering. The in situ static load tests of the footbridge before its acceptation for exploitation are shown and discussed. The results are compared with the corresponding ones from a numerical equivalent single layer model of the sandwich structure created within the framework of finite element...
-
Non-Destructive Testing of the Longest Span Soil-Steel Bridge in Europe—Field Measurements and FEM Calculations
PublicationThe article describes interdisciplinary and comprehensive non-destructive diagnostic tests of final bridge inspection and acceptance proposed for a soil-steel bridge made of corrugated sheets, being the European span length record holder (25.74 m). As an effect of an original concept a detailed and precise information about the structure short-term response was collected. Periodic diagnostics of bridge deformations was done one...
-
Influence of Actual Curing Conditions on Mechanical Properties of Concrete in Bridge Superstructures
PublicationThis article presents the research on the mechanical characteristics of concrete in the construction of three concrete bridges. A system of recording the internal temperature of concrete and automatic control of laboratory ovens was used for specimen curing. This allowed the specimens to be cured under conditions similar to those occurring in the structure. Before the construction, reference blocks were used to define similar curing...
-
Nondestructive methods complemented by FEM calculations in diagnostics of cracks in bridge approach pavement
PublicationNondestructive methods of road pavement diagnostics are an alternative to traditional approach to pavement failure investigation. The article presents a detailed multidisciplinary inspection carried out using ground-penetrating radar (GPR), laser scanning technology and finite element method (FEM) calculations. It was done in order to assess the factors that contributed to occurrence of premature cracks of a bridge approach pavement....
-
Dynamic Response of the Suspended on a Single Cable Footbridge
PublicationThe article presents numerical simulations, dynamic in situ load tests and a structural health monitoring (SHM) system installed in a suspended on a single cable footbridge. Numerical simulations performed prior to construction indicated the possibility of structural dynamics problems, finally confirmed in the course of dynamic test loading. In the dynamic load course the bridge deck developed vibrations displaying accelerations...
-
Structural Health Monitoring System for Suspension Footbridge
PublicationThe article presents the structural health monitoring (SHM) system installed in a footbridge in Radom. The main reason for the need for fitting of such a system was failed acceptance tests of the bridge. While under a dynamic load consisting of a group of 12 pedestrians jumping on the bridge, the bridge developed vibration during which acceleration of the deck of up to 4.5 m/s2 was recorded. Such behavior of the footbridge causes...
-
BADANIA KOMPOZYTOWEGO MOSTU DLA PIESZYCH
PublicationThe paper presents in situ load testing of the innovative footbridge of FOBRIDGE grant mounted at Gdansk University of Technology. The span of composite sandwich structure (GFRP skins, PET core) and the scope of static and dynamic tests are presented. The selected, representative results of in situ measurements and data obtained from the SHM monitoring system are discussed. Besides the standard testing procedures on the full scale...
-
Modern GFRP Composite Footbridges
PublicationApplication of GFRP composites in civil engineering is still not large but already noticeable. Advantages of this material, such as: low volume weight, relatively high stiffness and strength, well fatigue resistance, easiness in shaping, high material damping and high environmental resistance, make it attractive for bridge and in particular foot-bridge designers. It is estimated that nowadays in the world there are realized hundreds...
-
Three-point bending test of sandwich beams supporting the GFRP footbridge design process - validation
PublicationSome selected aspects concerning material and construction design issues for pedestrian footbridge made of GFRP composite materials are elaborated in this paper. The analysis is focused on validation tests, which are particularly important because of the advanced technology and materials that are used for this innovative bridge. The considered footbridge is a sandwich-type shell structure comprising of PET foam core and outer skins...
-
Die neue Straßenbrücke in Toruń (Thorn) – Teil 2 – Nachweise
PublicationAls Fortsetzung von Teil 1, der über den Entwurf und den Bau der neuen, die Weichsel querenden Straßenbrücken in Toruń (deutsch: Thorn) berichtet, geht es im Folgenden um die theoretischen und experimentalen Nachweisen zum Montageprozess und zu Probebelastungen. Somit eine umfassende Beurteilung der beschriebenen , herausragenden Ingenieursleistung gegeben.
-
OCENA NOŚNOŚCI STAREGO MOSTU ŁUKOWEGO W JAGODNIKU
PublicationArtykuł opisuje przeprowadzoną analizę statyczno-wytrzymałościowa 95-letniego betonowego mostu łukowego zlokalizowanego w Jagodniku w północnej Polsce. Trwałość i wytrzymałość starego betonu są określane na podstawie wybranych właściwości mechanicznych, fizycznych i chemicznych. Program badań laboratoryjnych składał się z następującego zestawu badań: pomiary głębokości strefy skarbonatyzowanej i gęstości w stanie suchym, badania...
-
Original footbridge in Mikolajki, Poland
PublicationIn summer 2016, a new footbridge in the town of Mikołajki (Poland) was built, over a stream connecting two adjacent lakes – Talty and Mikołajki. Its modern construction, based on the shape of a DN ice-boat, makes it inique in Poland, and probably in the world as well. This novel and dynamic shape became a significant landmark associated not only with Mikołajki, but also with the whole region of Mazury, as well as with sailing...
-
Rebuilding Bailey Bridge to Bridge With Bascule Span – A Case Study
PublicationThe structural analysis of a road foldable prefabricated steel Bailey- type bridge located over the Tuga River in Żelichowo, Poland is performed in this paper. Interesting and untypical bridge redevelopment performed made it possible to lift the middle foldable bridge span by approximately 4.0 m concerning the existing state. The paper begins with a survey of literature carried out on the investigations of foldable Bailey-type...
-
Zmodernizowany most Łazienkowski w Warszawie – analizy z wykorzystaniem modelu numerycznego MES
PublicationW artykule przedstawiono proces modelowania statycznego przęseł mostu Łazienkowskiego w Warszawie, który został poddany odbudowie po pożarze 14 lutego 2015 r. Sprawdzające obliczenia numeryczne wykonano w związku z badaniami konstrukcji podczas próbnego obciążenia. Przeprowadzono weryfikację obliczeń projektowych i zaprojektowano próbne obciążenie. Podsumowano wyniki analizy i badań. Dodatkowo opisano nową, stalową konstrukcję...
-
Lagrangian model of an isolated dc-dc converter with a 3-phase medium frequency transformer accounting magnetic cross saturation
PublicationThis article presents a nonlinear equivalent circuit model of an isolated dc-dc converter with a 3-phase medium frequency transformer. The model takes into account the magnetic cross saturation of the 3-phase core-type magnetic circuit. The model is suitable in detailed electromagnetic transient simulations of power systems involving isolated dc-dc converters. The model is developed using the Lagrange energy method. It involves...
-
Analysis of AC/DC/DC Converter Modules for Direct Current Fast-Charging Applications
PublicationThe paper is a comprehensive laboratory comparison study of two galvanic isolated solution off-board battery chargers: (1) Si-based cost-effective case, and (2) SiC-bidirectional ready for vehicle to grid concept case. All circuits are modular, and in both cases the DC/DC converter can be replaced according to the end user requirements (the coupled transformer remains the same and is constructed based on 12xC100 cores to avoid...
-
Dynamic analysis of the railway bridge span under moving loads
PublicationThe first part of this paper provides a review of the state of knowledge of the dynamic behaviour of railway bridges under moving loads. Particular attention is paid to developments in modelling railway bridge loading and dynamic vehicle-span (structure) interaction. The most important aspects determining the advancements in this area of knowledge are identified. The contemporary techniques for defining bridge span finite element...
-
Diagnostics and monitoring of the longest span extradosed bridge in Europe
PublicationThe article presents complex diagnostic procedures applied for the purpose of behavior analysis of the extradosed bridge with the longest span in Europe that was built in 2018 in Poland. The system of health monitoring was used to: register internal forces in temporary supports, monitor concrete bonding, perform in situ diagnostics and operation tests. The bridge is a continuous four-span structure with spans theoretical lengths...
-
A dynamic vehicle-bridge model based on the modal identification results of an existing EN57 train and bridge spans with non-ballasted tracks
PublicationThis paper addresses the methodology of the bridge-vehicle dynamic model definition based on the free response measurements of an existing train and existing bridge spans. In the case of the railway vehicle, the methodology uses the impulse excitations of a single car by means of the wedge method. In the case of the bridge spans, free responses are collected after the passages of trains. The global modal parameters (frequencies...
-
3-phase medium frequency transformer for a 100kW 1.2kV 20kHz Dual Active Bridge converter
PublicationThe article presents a three-phase Medium Frequency Transformer being a part of a 100kW 1.2kV 20kHz Dual Active Bridge DC-DC converter. The transformer design is detailed focusing on winding and core power loss calculation. The high power three-phase MFT prototype is presented. The experimental results include the transformer impedance characteristics, no load test and three-phase DAB full load test waveforms
-
Pylon foundation of a cable stayed bridge at the motorway ring road of Wrocław
PublicationThe largest bridge of the motorway ring road of Wroclaw is a cable stayed bridge over the Odra river near Rędzin. Due to hydrogeological conditions of the ground it was not convenient to use standard bored piles of high length. Instead shorter piles were applied with additional improvement by cement injections at the pile toes. This decision was possible by extending ground investigation program and application of numerical modeling...
-
Determination of Thermophysical Parameters Involved in The Numerical Model to Predict the Temperature Field of Cast-In-Place Concrete Bridge Deck
PublicationThe paper dealswith a concept of a practical computationmethod to simulate the temperature distribution in an extradosed bridge deck. The main goal of the study is to develop a feasible model of hardening of concrete consistent with in-situ measurement capabilities. The presented investigations include laboratory tests of high performance concrete, measurements of temperature evolution in the bridge deck and above all, numerical...
-
Numerical Modeling of Water and Ice Dynamics for Analysis of Flow Around the Kiezmark Bridge Piers
PublicationThis paper presents the results of a numerical model study on the effect of ice on the proposed bridge piers in the Vistula River outlet and its effect on flow conditions in the river. The model DynaRICE is used in this study, which is a two-dimensional hydro-ice dynamic numerical model developed for dynamic ice transport and jamming in rivers. To simulate river hydrodynamics in the vicinity of the bridge piers, 2-dimensional numerical...
-
Historical crane on the redesigned original trestle bridge as a memorial of Gdansk Shipyard
PublicationThe paper includes selected aspects of the study, whose goal is to hold the historical crane 642-24 in its current location after the modification of trestle bridge static scheme. The scope of the paper includes the assessment of current technical condition of the object, a presentation of FEM analyses, a description of the assumed load cases, results of the static calculations, checking the effort of construction elements, global...
-
Chemical, Physical, and Mechanical Properties of 95-Year-Old Concrete Built-In Arch Bridge
PublicationThis research aimed to determine the durability and strength of an old concrete built-in arch bridge based on selected mechanical, physical, and chemical properties of the concrete. The bridge was erected in 1925 and is located in Jagodnik (northern Poland). Cylindrical specimens were taken from the side ribs connected to the top plate using a concrete core borehole diamond drill machine. The properties of the old concrete were...