Filters
total: 859
filtered: 772
Search results for: MICRO-VOLUME GLASS CAPILLARY FLUOROMETER PEPTIDE-BASED SENSOR
-
Peptide-Based Rapid and Selective Detection of Mercury in Aqueous Samples with Micro-Volume Glass Capillary Fluorometer
PublicationMercury, a toxic heavy metal produced through both natural and anthropogenic processes, is found in all of Earth’s major systems. Mercury’s bioaccumulation characteristics in the human body have a significant impact on the liver, kidneys, brain, and muscles. In order to detect Hg2+ ions, a highly sensitive and specific fluorescent biosensor has been developed using a novel, modified seven amino acid peptide, FY7. The tyrosine ring...
-
Determination of long-chain aldehydes using a novel quartz crystal microbalance sensor based on a biomimetic peptide
PublicationThere is an increasingly popular trend aimed at improvement of fundamental metrological parameters of sensors via implementation of materials mimicking biological olfactory systems. This study presents investigation on usefulness of the peptide mimicking HarmOBP7 region as a receptor element of the piezoelectric sensor for selective analysis of long-chain aldehydes. Identification of odorant binding proteins creates new possibilities...
-
Low-volume label-free SARS-CoV-2 detection with the microcavity-based optical fiber sensor
PublicationAccurate and fast detection of viruses is crucial for controlling outbreaks of many diseases; therefore, to date, numerous sensing systems for their detection have been studied. On top of the performance of these sensing systems, the availability of biorecognition elements specific to especially the new etiological agents is an additional fundamental challenge. Therefore, besides high sensitivity and selectivity, such advantages...
-
A Highly Selective Biosensor Based on Peptide Directly Derived from the HarmOBP7 Aldehyde Binding Site
PublicationThis paper presents the results of research on determining the optimal length of a peptide chain to eectively bind octanal molecules. Peptides that map the aldehyde binding site in HarmOBP7 were immobilized on piezoelectric transducers. Based on computational studies, four Odorant Binding Protein-derived Peptides (OBPPs) with dierent sequences were selected. Molecular modelling results of ligand docking with selected peptides were...
-
Evaluation of Linkers’ Influence on Peptide-Based Piezoelectric Biosensors’ Sensitivity to Aldehydes in the Gas Phase
PublicationRecent findings qualified aldehydes as potential biomarkers for disease diagnosis. One of the possibilities is to use electrochemical biosensors in point-of-care (PoC), but these need further development to overcome some limitations. Currently, the primary goal is to enhance their metrological parameters in terms of sensitivity and selectivity. Previous findings indicate that peptide OBPP4 (KLLFDSLTDLKKKMSEC-NH2) is a promising...
-
Polypyrrole based gas sensor for ammonia detection
PublicationThe nature of polypyrrole response to toxic gases does not allow using the sensor in a conventional way. The main aim of this study is to acquire the information about the concentration using different approaches: a linear approximation, a non-linear approximation and a tangent method. In this paper a two-steps procedure for sensor response measurements has been utilized. Polypyrrole films were electrochemically synthesized on...
-
Design of Microwave-Based Angular Displacement Sensor
PublicationThis letter presents a novel microwave-based rotation sensor having a wide dynamic range to detect and measure the angular displacement in terms of the change in resonant frequency. The proposed sensor is based on the microstrip technology, where a rotor comprised of a complementary splitring resonator (CSRR) placed on the ground plane of the microstrip line is free to rotate around its axis. The mechanical rotation of CSRR determines...
-
Microwave Ring Resonator Based Pressure Sensor
PublicationThis paper demonstrates a microwave pressure sensor, which is based on microstrip line-fed ring resonators. The first ring resonator is loaded with the concentric cylindrical shafts, while the same number of the hollow shanks as the shafts are mounted on the second ring resonator. The arrangement of the cylindrical shaft and hollow shank allows for mechanical movement between two substrates while maintaining electrical contact....
-
An Implementation of a Compact Smart Resistive Sensor Based on a Microcontroller with an Internal ADC
PublicationIn the paper a new implementation of a compact smart resistive sensor based on a microcontroller with internal ADCs is proposed and analysed. The solution is based only on a (already existing in the system) microcontroller and a simple sensor interface circuit working as a voltage divider consisting of a reference resistor and the resistive sensor connected in parallel with an interference suppression capacitor. The measurement...
-
Antibiotic-Based Conjugates Containing Antimicrobial HLopt2 Peptide: Design, Synthesis, Antimicrobial and Cytotoxic Activities
PublicationRecent studies have shown that modified human lactoferrin 20−31 fragment, named HLopt2, possesses antibacterial and antifungal activity. Thus, we decided to synthesize and evaluate the biological activity of a series of conjugates based on this peptide and one of the antimicrobials with proven antibacterial (ciprofloxacin, CIP, and levofloxacin, LVX) or antifungal (fluconazole, FLC) activity. The drugs were covalently connected...
-
Development and Assessment of Regeneration Methods for Peptide-Based QCM Biosensors in VOCs Analysis Applications
PublicationCleaning a quartz crystal microbalance (QCM) plays a crucial role in the regeneration of its biosensors for reuse. Imprecise removal of a receptor layer from a transducer’s surface can lead to unsteady operation during measurements. This article compares three approaches to regeneration of the piezoelectric transducers using the electrochemical, oxygen plasma and Piranha solution methods. Optimization of the cleaning method allowed...
-
Effect of oxygenation time on signal of a sensor based on ionic liquids
PublicationThe paper presents an oxygen sensor based on ionic liquids and solid electrodes. The following ionic liquids have been employed: [BMIM][BF4], [HMIM][Cl], [BMIM][N(CN2)]. Minimum time of the sensor exposure to analyte, after which the signal (current intensity) was stable, has been evaluated. An impact of volumetric flow rate of analyte on the sensor exposure time and signal has been determined. A product of permeability coefficient...
-
Properties of Nasicon-based CO2 sensor with Bi8Nb2O17 reference electrode
PublicationGas sensors are useful for the carbon dioxide concentration monitoring in many applications. The major challenge is to develop a potentiometric sensor working without the necessity of a reference gas and without a need of the reference electrode encapsulation. Important issue is a selection of reference electrode material, which should provide stable reference potential. For example as reference electrode material in sensor based...
-
A compact smart sensor based on a neural classifier for objects modeled by Beaunier's model
PublicationA new solution of a smart microcontroller sensor based on a simple direct sensor-microcontroller interface for technical objects modeled by two-terminal networks and by the Beaunier’s model of anticorrosion coating is proposed. The tested object is stimulated by a square pulse and its time voltage response is sampled four times by the internal ADC of microcontroller. A neural classifier based on measurement data classifies the...
-
Hardware-Software Implementation of a Sensor Network for CityTraffic Monitoring Using the FPGA- and ASIC-Based Sensor Nodes
PublicationArtykuł opisuje prototypową sieć sensorową do monitorowania ruchu pojazdów w mieście. Węzły sieci sensorowej, wyposażone w kamerę o niskiej rozdzielczości, obserwują ulice i wykrywają poruszające się obiekty. Detekcja obiektów jest realizowana w oparciu o własny algorytm segmentacji obrazów, wykorzystujący podwójne odejmowanie tła, wykrywanie krawędzi i cieni, działający na dedykowanym systemie mikroelektronicznym typu ''System...
-
Amino Acid and Peptide‐Based Antiviral Agents
PublicationA significant number of antiviral agents used in clinical practice are amino acids, short peptides, or peptidomimetics. Among them, several HIV protease inhibitors (e. g. lopinavir, atazanavir), HCV protease inhibitors (e. g. grazoprevir, glecaprevir), and HCV NS5A protein inhibitors have contributed to a significant decrease in mortality from AIDS and hepatitis. However, there is an ongoing need for the discovery of new antiviral...
-
The effective elastic properties of human trabecular bone may be approximated using micro-finite element analyses of embedded volume elements.
PublicationBoundary conditions (BCs) and sample size affect the measured elastic properties of cancellous bone. Samples too small to be representative appear stiffer under kinematic uniform BCs (KUBCs) than under periodicity-compatible mixed uniform BCs (PMUBCs). To avoid those effects, we propose to determine the effective properties of trabecular bone using an embedded configuration. Cubic samples of various sizes (2.63, 5.29, 7.96, 10.58...
-
Analysis of the possibility of increasing thermal-electric energy conversion ratio in CHP units based on micro gas turbine
PublicationThe aim of this paper is to analyze the possibility of increasing thermal energy to electricity conversion efficiency in combined heat and power (CHP) units based on micro gas turbine during low heat demand periods. At the beginning sustainable development postulates under power engineering are explained. Next micro CHP as part of distributed generation idea is presented. The main part of the article is based on results of thermodynamic...
-
A measurement method for capacitive sensors based on a versatile direct sensor-to-microcontroller interface circuit
PublicationIn the paper, there is presented a new time-domain measurement method for determining the capacitance values of capacitive sensors, dedicated, among others, to capacitive relative humidity sensors. The method is based on a versatile direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators (ACs) and with precision voltage reference sources, e.g. digital-to-analog converters (DACs). The reference...
-
Determination of the Theoretical and Actual Working Volume of a Hydraulic Motor—Part II (The Method Based on the Characteristics of Effective Absorbency of the Motor)
Publication: In this article, the second method of determination of the theoretical and actual working volume of a hydraulic motor is described. The proposed new method is based on the characteristics of effective absorbency of the motor. The effective absorbency has been defined as the ratio of flow rate in a motor to the rotational speed of the motor’s shaft. It has been shown that the effective absorbency is a nonlinear function of the...
-
A New Approach to Capacitive Sensor Measurements Based on a Microcontroller and a Three-Gate Stable RC Oscillator
PublicationA complete smart capacitive sensor solution basedA complete smart capacitive sensor solution based on a microcontroller was developed. This approach includes the development of both the hardware and software. The hardware part comprises an 8-bit microcontroller equipped with two timers/counters and a three-gate stable RC relaxation oscillator. The software part handles system configuration, measurement control, communication control,...
-
Determination of toxic gases based on the responses of a single electrocatalytic sensor and pattern recognition techniques
PublicationA response from an electrocatalytic gas sensor contains fingerprint information about the type of gas and its concentration. As a result, a single gas sensor can be used for the determination of different gases. However, information about the type of gas and its concentration is hidden in the unique shape of the current–voltage response and it is quite difficult to explore. One of the ways to get precise information about the measured...
-
Design and Experimental Validation of a Metamaterial-Based Sensor for Microwave Imaging in Breast, Lung, and Brain Cancer Detection
PublicationThis study proposes an innovative geometry of a microstrip sensor for high-resolution microwave imaging (MWI). The main intended application of the sensor is early detection of breast, lung, and brain cancer. The proposed design consists of a microstrip patch antenna fed by a coplanar waveguide with a metamaterial layer-based lens implemented on the back side, and an artificial magnetic conductor (AMC) realized on as a separate...
-
Multilevel inverter neutral-point voltage sensor diagnostic based on the Extended Kalman Filter
PublicationA new algorithm for neutral point voltage imbalance estimation in DC link of the three-level (3L) neutral point clamped (NPC) voltage source inverter (VSI) is proposed. Application of the proposed algorithm does not require any additional sensors. The unbalanced voltage calculation is based on the information derived from the inverter output measured currents and from the knowledge of the load model parameters. In order to estimate...
-
Zirconia-based mixed potential sensor with Pt electrode prepared by spin-coating of polymeric precursor
PublicationMany types of yttria-stabilized zirconia (YSZ) based gas sensors have been explored extensively in recent years. Great attention have been directed to mixed-potential-type gas sensors. It is due to growing concerns with environmental issues. Not without a significance is the fact of very attractive performance of this type of sensor allowing to detect low concentration of pollutant gases. In this paper two types of YSZ based mixed-potential...
-
An NO2 sensor based on WO3 thin films for automotive applications in the microwave frequency range
PublicationA microwave system dedicated to the detection of nitrogen dioxide in the harsh environment of the Norway highways is proposed. An optimized transmission line type of sensor coated with a tungsten trioxide thin film that changes its electrical properties under NO2 gas exposure is developed. The sensors' response (S) is given in °/GHz and it is calculated based on wideband measurements. The advantage of wideband measurements in comparison...
-
Natural deep eutectic solvent based ultrasound assisted liquid-liquid micro-extraction method for methyl violet dye determination in contaminated river water
PublicationSimple and green natural deep eutectic solvent (NADES) based ultrasound assisted liquid-liquid micro-extraction (UA-LLME) method was developed for extraction and determination of methyl violet dye in contaminated river water samples using UV/Vis spectrophotometry. Choline chloride - decanoic acid based natural deep eutectic solvent was used for extraction. Important analytical parameters like pH, deep eutectic solvent volume/phase...
-
DISPERSIVE LIQUID-LIQUID MICROEXTRACTION COUPLED WITH MICRO-VOLUME SPECTROPHOTOMETRY FOR DETERMINATION OF TOTAL IODINE IN URINE SAMPLES
Publication -
Multi-functional sensor based on photonic crystal fiber using plasmonic material and magnetic fluid
PublicationA unique highly sensitive photonic crystal fiber is investigated based on plasmonic material and magnetic fluid (MF) for the simultaneous measurement of temperature and magnetic field sensor. The designed sensor is explored by tracing the different parameters such as birefringence, coupling length, power spectrum, and the peak wavelength of the transmission intensity. The magnetic field and temperature computation are attained...
-
Element sensor based on microplasma generators
Publication -
A measurement method for lossy capacitive relative humidity sensors based on a direct sensor-to-microcontroller interface circuit
PublicationA new time-domain measurement method for determining the capacitance and resistance values of lossy relative humidity capacitive sensors is presented. The method is based on a direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators and timers. The interface circuit consists only of four reference resistors (two reference resistors if a microcontroller includes a voltage reference source),...
-
Time-domain measurement methods for R, L and C sensors based on aversatile direct sensor-to-microcontroller interface circuit
PublicationtIn the paper new time-domain measurement methods for determining values of resistive (R), inductive(L) and capacitive (C) sensors based on a versatile direct sensor-to-microcontroller interface for microcon-trollers with internal analog-to-digital converters (ADCs) and analog comparators (ACs) are presented.The interface circuit consists of a reference resistor Rrworking as a voltage divider, a given R, L or C sensorand a microcontroller...
-
Gemcitabine Peptide-Based Conjugates and Their Application in Targeted Tumor Therapy
Publication -
New Peptide Based Fluconazole Conjugates with Expanded Molecular Targets
PublicationInfections of Candida spp. etiology are frequently treated with azole drugs. Among azoles, the most widely used in the clinical scenario remains fluconazole (FLC). Promising results in treatment of dangerous, systemic Candida infections demonstrate the advantages of combined therapies carried out with combinations of at least two different antifungal agents. Here, we report five conjugates composed of covalently linked FLC and...
-
A turbine based domestic micro ORC system
Publication -
Buckling Analysis of a Micro Composite Plate with Nano Coating Based on the Modified Couple Stress Theory
PublicationThe present study investigates the buckling of a thick sandwich plate under the biaxial non-uniform compression using the modified couple stress theory with various boundary conditions. For this purpose, the top and bottom faces are orthotropic graphene sheets and for the central core the isotropic soft materials are investigated. The simplified first order shear deformation theory (S-FSDT) is employed and the governing differential...
-
electrocatalytic sensor based on nasicon with auxiliary layer
PublicationW pracy przedstawiono wyniki badań czujników elektrokatalitycznych z dodatkową warstwą. Właściwości takiego czujnika porównano z czujnikiem o tradycyjnej budowie.
-
A compact smart resistive sensor based on a microcontroller
PublicationPrzedstawiono nowe rozwiązanie inteligentnego czujnika rezystancyjnego bazującego na mikrokontrolerze, w którym czujnik rezystancyjny jest elementem składowym filtra anty-aliazingowego przetwornika A/C. Procedura pomiaru temperatury obejmuje pobudzenie filtra dwoma impulsami prostokątnymi o zadanym czasie trwania oraz próbkowanie jego odpowiedzi czasowej. Następnie na podstawie wartości pomierzonych próbek napięcia wyznaczana jest...
-
Experimental investigation of domestic micro-CHP based on the gas boiler fitted with ORC module
PublicationThe results of investigations conducted on the prototype of vapour driven micro-CHP unit integrated with a gas boiler are presented. The system enables cogeneration of heat and electric energy to cover the energy demand of household. The idea of such system is to produce electricity for own demand or for selling it to the electric grid – in such situation the system user will became the prosumer. A typical commercial gas boiler,...
-
Design and characterization of apatite La9.8Si5.7Mg0.3O26±δ-based micro-tubular solid oxide fuel cells
PublicationIn this study, electrolyte-supported (Cell A) and anode-supported (Cell B) micro-tubular solid oxide fuel cells (SOFCs) based on the La9.8Si5.7Mg0.3O26±δ (LSMO) electrolyte is built through an extrusion and dip-coating processes. The formulations and process conditions for these cells are established and optimized. Both cell configurations show no visible delamination or cracking, and reaction zones and inter-diffusion of any species...
-
Chromium‑based metal organic framework for pipette tip micro‑solid phase extraction: an effective approach for determination of methyl and propyl parabens in wastewater and shampoo samples
PublicationAbstract Background A chromium-based metal organic framework was synthesized and employed as an efficient sorbent for pipette tip micro-solid phase extraction and preconcentration of parabens from wastewater and shampoo samples up to sub-ppb level before their spectrophotometric analysis. Results Factors affecting preconcentration including volume and type of solvent, amount of sorbent, number of extraction, and volume and pH of...
-
Evaluation of Glass Powder-Based Geopolymer Stabilized Road Bases Containing Recycled Waste Glass Aggregate
Publication -
Cost-Efficient Measurement Platform and Machine-Learning-Based Sensor Calibration for Precise NO2 Pollution Monitoring
PublicationAir quality significantly impacts human health, the environment, and the economy. Precise real-time monitoring of air pollution is crucial for managing associated risks and developing appropriate short- and long-term measures. Nitrogen dioxide (NO2) stands as a common pollutant, with elevated levels posing risks to the human respiratory tract, exacerbating respiratory infections and asthma, and potentially leading to chronic lung...
-
The dispersive micro-solid phase extraction method for MS-based lipidomics of human breast milk*
PublicationA simple and rapid microextraction method ensuring high lipidome coverage was developed for liquid chromatography mass spectrometry (LC-MS)-based lipidomics of human breast milk. The dispersive microsolid phase extraction (D-µ-SPE) technique, coupled with the design of experiment (DoE) method, enabled the study of the influence of several conditions (desorption solvent, stationary phase ratio, and sorption and desorption time)...
-
Localization in wireless sensor networks based on zigbee platform
PublicationW artykule porównano dwie różne metody lokalizacji w sieciach sensorów bezprzewodowych. Jedną z metod jest implementacja sprzętowa algorytmu w układzie nadawczo odbiorczym CC2431. Drugą metodą jest implementacja programowa. Wyniki testów przeprowadzonych na otwartym terenie oraz w pomieszczeniach zamkniętych zostały przedstawione i porównane w pracy.
-
Electrical properties of polymer humidity sensor based on polyethyleneimine.
PublicationW pracy przedstawiono wyniki badań amperometrycznych właściwości czujników wilgotności na bazie PEI. Pokazano, że przepływ prądu jest wynikiem reakcji elektrodowej na anodzie.
-
Optical monitoring of electrochemical processes with ITO-based lossy-mode resonance optical fiber sensor applied as an electrode
PublicationIn this work we discuss the application of optical fiber sensors based on lossy-mode resonance (LMR) phenomenon for real-time optical monitoring of electrochemical processes. The sensors were obtained by a reactive high power impulse magnetron sputtering of indium tin oxide (ITO) on a 2.5 cm-long core of polymer-clad silica fibers. The LMR effect made monitoring of changes in optical properties of both ITO and its surrounding medium...
-
Electrospinning: An Efficient Biopolymer-Based Micro- and Nanofibers Fabrication Technique
Publication -
Advanced Sensor for Non-Invasive Breast Cancer and Brain Cancer Diagnosis Using Antenna Array with Metamaterial-Based AMC
PublicationMicrowave imaging techniques can identify abnormal cells in early development stages. This study introduces a microstrip patch antenna coupled with artificial magnetic conductor (AMC) to realize improved sensor for non-invasive (early-stage) breast cancer and brain cancer diagnosis. The frequency selectivity of the proposed antenna has been increased by the presence of AMC by creating an additional resonance at 2.276 GHz associated...
-
GNSS-based multi-sensor system for structural monitoring applications
Publication