Filters
total: 5916
filtered: 4577
-
Catalog
Chosen catalog filters
displaying 1000 best results Help
Search results for: REACTIVE POWER, MATRIX CONVERTER, VOLTAGE SOURCE INVERTER, REACTIVE POWER COMPENSATOR, MULTILEVEL INVERTER
-
Exact generation of voltage vector in voltage inverter with pulse width modulation
PublicationW artykule zaproponowano metodę modulacji szerokości impulsów dla falownika napięcia. Proponowana metoda rozwiązuje problemy związane z kompensacją czasów martwych oraz kompensacją wpływu parametrów łączników energolelektronicznych na napięcie wjściowe falownika. W artykule zaprezentowano metodę kompensacji między innymi pojemności pasożytniczych tranzystorów, dyskretyzacji czasów załączeń tranzystorów. Przedstawiona metoda modulacji...
-
Resonant Conditions in a Node with an SVC Compensator
PublicationThe primary purpose of installing static shunt compensators in power grids is to improve the voltage conditions. Additional reactive power sources increase the system’s voltage stability and enable faster system recovery after a voltage failure. This paper presents the impact of an SVC device’s structure and settings on impedance change in the supply system, and hence on the frequencies at which resonance phenomena can develop.
-
Nuclear power plant as a source of electrical energy and heat
PublicationIn this paper certain issues concerning usage of nuclear power plants as sources of not only electric power but also thermal energy will be discussed. For such a solution appeals most of all the need to limit harmful emissions of gases (including CO2) and ashes, which come from the process of burning fossil fuels, as well as the raising demand for network heat and chill. Additionally combined heat and power production brings measurable...
-
Voltage profiles improvement in a power network with PV energy sources – results of a voltage regulator implementation
PublicationThe constant increase in the number of photovoltaic (PV) energy sources in distribution networks is the cause of serious voltage problems. The networks built at least a dozen years ago are not provided for the installation of a large number of micro-sources. It happens that the previously properly functioning power networks are not able to provide to consumers power with the required parameters, after installing many PV sources....
-
A predictive estimation based control strategy for a quasi-resonant dc-link inverter
PublicationIn this paper the predictive estimation based control strategy for a quasi-resonant dc link inverter (PQRDCLI) is developed. Instead of direct measurement of dc link input inverter current – its estimation with one step prediction is applied. The PQRDCLI fed induction motor, controlled with a predictive current estimation stabilized inverter output voltage slopes independently of load. Moreover, reduction of overvoltage spikes...
-
Open-Phase Fault Detection Method for Sensorless Five-Phase Induction Motor Drives with an Inverter Output Filter
PublicationThe paper presents the sensorless five-phase induction motor drive implementation with an inverter output filter with third harmonic injection. For the sensorless operation, the required observers are presented for the first and third harmonics with consideration of the inverter output filter. Moreover, the interaction of the observers and the control system is capable to handle a deactivation of one or two phases, which improves...
-
Sensorless Fault Detection of Induction Motor with Inverter Output Filter
PublicationThe paper presents the problem of monitoring and fault detection of a sensorless voltage inverter fed squirrel cage induction motor with LC filter. The detection is based on load torque estimation of the investigated torque transmission system. The load torque is calculated besides the computation of other variables that are mandatory for sensorless drive operation such as rotor flux and speed. The implemented LC filter smooths...
-
Influence of Shunt Compensation with SVC Devices on Resonance Risk in Power Systems
PublicationMany analyses are required to locate a new reactive power source in a power system. The choice of a location is a very complex matter which requires various aspects to be considered. Selecting a location also entails the necessity to assess it from the point of view of the selected compensator’s structure as well as the system’s performance in various states with the new device on. The paper presents the issues of assessing compensator...
-
Power Hardware-In-the-Loop Approach for Autonomous Power Generation System Analysis
PublicationThe article presents the Power Hardware-In-the-Loop (PHIL) dynamic model of a synchronous generator of 125 kVA for autonomous power generation system analysis. This type of system is typically composed of electrical energy sources in the form of several diesel generator units with synchronous machines, the main distribution switchboard and different loads. In modern power distribution systems, the proposed power management strategies...
-
Analysis of Induced Voltages and Power Losses in High Voltage Power Cables for Selected Methods of Cables Sheaths Bonding
PublicationPower is increasingly supplied to city centres with 110 kV cable lines. This is a convenient way to supply power, and practically the only one possible in areas of dense urban development. A high-voltage cable contains a coaxial metallic sheath, in which in normal operation and in fault conditions (during short-circuits) significant line-to-earth voltages can be induced, which threatens electric shock and/or damage to the cable’s...
-
AC-DC-DC Converter for Small Power Energy Storage Systems
PublicationThe energy transformation driven by the development of renewable energy sources has become a reality for all power grid users. Prosumer energy, primarily utilizing photovoltaic installations, is one of the fastest-growing market segments. The advancement of technology, a decrease in electrochemical energy storage prices, and changes in the legal framework governing energy billing for grid-fed power have led to a growing interest...
-
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublicationLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...
-
The Possibility to use a Nuclear Power Plant as a Source of Electrical Energy and Heat
PublicationIn this article issues concernig the possibility of nuclear power plant (NPP) operation also as a source of heat, which means combined heat and power production, have been described. CHP work is possible and profitable only in those areas where high thermal power demand occurs, which means near city agglomerations such as Warsaw or the Tri-City. Two levels of thermal power delivered to the heating system have been considered. Preliminary...
-
Control strategy for the multilevel cascaded H-bridge converter
PublicationThe paper presents the control strategy for Cascaded H-bridge (CHB) converter . The converter output voltage using Space-Vector Pulse Width Modulation (SV-PWM) strategy is controlled. The DC-link voltages are controlled by appropriate choice of H-Bridges and appropriate choice of active and passive vectors.
-
Cast polyurethanes obtained from reactive recovered polyol intermediates via crude glycerine decomposition process
PublicationIn this work, the possibility of applying intermediates from polyurethane waste recycling in polyurethane synthesis was presented. Polyurethanes were synthesised in a two-step method using a mixture of petrochemical polyol and glycerolysate, used as a reactive component, 4,4-diphenylmethane diisocyanate (MDI) and 1,4-buthanediol (BD). Glycerolysates were produced during decomposition of polyurethane elastomer by crude glycerine...
-
Light-Powered Starter for Micro-Power Boost DC–DC Converter for CMOS Image Sensors
PublicationThe design of a starter for a low-voltage, micro-power boost DC–DC converter intended for powering CMOS image sensors is presented. A unique feature of the starter is extremely low current, below 1 nA, supplying its control circuit. Therefore, a high-voltage (1.3 V) configuration of series-connected photovoltaic diodes available in a standard CMOS process or a small external LED working in photovoltaic mode can be used as an auxiliary...
-
Effect of nitrogen doping on TiOxNythin film formation at reactive high-power pulsed magnetron sputtering
Publication -
Optimization of thermal backfill configurations for desired high-voltage power cables ampacity
PublicationThe ampacity of high-voltage power cables depends, among others, on their core cross-sectional area as well as thermal resistivity of the thermal backfill surrounding the cables. The cross-sectional area of the power cables’ core is selected according to the expected power to be transferred via the cable system. Usually, the higher the power transfer required, the higher the cross-sectional area of the core. However, the cost of...
-
Over-Voltage Studies in Inverter Fed Induction Motor Drives
PublicationW pracy przedstawiono metodę identyfikacji pojemności pasożytniczych uzwojeń silników asynchronicznych uwzględniającą ich rozłożony charakter. Przedstawiony szerokopasmowy model obwodowy uzwojeń silnika asynchronicznego pozwala na modelowanie zjawisk przepięciowych w silnikach asynchronicznych, w szczególności zasilanych poprzez przekształtniki energoelektroniczne. Zaproponowana metoda analizy umożliwia również określanie składowych...
-
Reactive Energy Billing in Operator Tariffs in Poland
PublicationThe paper describes the current method of reactive energy billing in the tariffs of distribution grid operators in Poland. The current solutions are subject to critical assessment. Issues related to the motivation effect of the current solutions on consumers are analysed. Problems that occur in relation with connecting distributed generators to the distribution grid and challenges related to prosumer billing are indicated.
-
Selective Harmonic Elimination PWM For a Cascaded Multi-level Inverter
PublicationThis paper deals with the selective harmonic elimination pulse width modulation (SHE-PWM) technique. This technique is used for the elimination of selected dominant low order harmonics in the multi-level inverter output voltage. The presence of these harmonics is the essential drawback of such kind of inverters; especially when it is used for the control of different AC drivers. The SHE-PWM is based...
-
Conducted EMI Propagation Paths in DC-AC Hard Switching Converter
PublicationIn order to limit the electromagnetic interference (EMI) in power electronics devices, knowledge about the phenomena connected with EMI generation and propagation is necessary. This papers describes the propagation paths in the 3 phase voltage source inverter using wide-band simulation and laboratory test with the signal processing method Wiener filtering, where the transfer functions between voltage across switches and the perturbation...
-
Starter for Voltage Boost Converter to Harvest Thermoelectric Energy for Body-Worn Sensors
PublicationThis paper examines the suitability of selected configurations of ultra-low voltage (ULV) oscilla-tors as starters for a voltage boost converter to harvest energy from a thermoelectric generator (TEG). Important properties of particularly promising configurations, suitable for on-chip imple-mentation are compared. On this basis, an improved oscillator with a low startup voltage and a high output voltage swing is proposed. The applicability...
-
Sensorless Control of Induction Motor Supplied by Current Source Inverter
Publication -
Variable Speed AC Drives with Inverter Output Filters
PublicationThe advance of variable speed drives systems (VSDs) engineering highlights the need of specific technical guidance provision by electrical machines and drives manufacturers, so that such applications can be properly designed to present advantages in terms of both energy efficiency and expenditure. This book presents problems and solutions related to inverter-fed electrical motors. Practically orientated, the book describes the...
-
An Extended Control of the Input Angle for Matrix Converters Connected with the Non-Unity Power Factor Loads.
PublicationThis paper proposes a novel PWM modulation algorithm for Multiphase Conventional Matrix Converters (MCMC), with 3 inputs and k outputs, using the transfer function of the load angle. The proposed approach extends the range of power angle control at the input during the operation with a maximum voltage transfer ratio. The proposed concept is based on the Direct Analytic Voltage PWM (DAV--PWM) modulation with an elliptical trajectory...
-
The Influence of LED Lighting Sources on the Nature of Power Factor
PublicationThis article presents measurements of electric power absorbed by a newly built facility for office and scientific research activities. These measurements highlighted the need for compensation of capacitive reactive power—not predicted by the designer—due to the vast use of LED lighting in the facility. The article also describes a reactive power compensation system, designed on the basis of the above-mentioned measurements, and...
-
Speed sensorless asynchronous motor drive with inverter output lc filter
PublicationIn this paper a speed sensorless ac drive with inverter and output LC filter is proposed. A nonlinear, decoupled field oriented control algorithm with a flux and speed close-loop observer is used. In spite of using LC filter on the inverter output, the sensorless system works precisely. That result are obtained as a result of the appropriate estimation and control system use. The theory, simulation, and experimental results are...
-
Computer-aided Analysis of Induced Sheath Voltages in High Voltage Power Cable System
PublicationThis paper concerns the effect of configuration of high voltage power cables on induced voltages in their metallic sheaths. One, two or three cables per phase and phase sequence of the cables are considered. Computing of the voltages was performed for a normal operation and in case of earth fault. Various ways of the sheaths bonding are considered as well. Shock hazard and voltage stress of non-metallic outer sheath of cables are...
-
Analysis of Ferroresonance Mitigation Effectiveness in Auxiliary Power Systems of High-Voltage Substations
PublicationFerroresonance in power networks is a dangerous phenomenon, which may result in overcurrents and overvoltages, causing damage to power equipment and the faulty operation of protection systems. For this reason, the possibility of the occurrence of ferroresonance has to be identified, and adequate methods need to be incorporated to eliminate or reduce its effects. The aim of this paper is to evaluate the effectiveness of ferroresonance...
-
Reactive Processing and Functionalization of Ground Tire Rubber
PublicationThe dynamic development of the automotive industry resulted in a sig- nificant increase in rubber wastes, especially end-of-life tires, which are a serious threat to the natural environment and human health. This situation has enforced the industry and academic research groups to search new and cost-effective methods for recycling waste tires. In this field of research, reactive processing and functionaliza- tion seem to be a...
-
Destructive Consequences of PWM Inverter Feeding for Traction AC Motors
PublicationThe electric traction drives with an AC motor fed by a frequency converter are used more and more often nowadays. The most significant side effects, of a converter's output voltage forming PWM method for AC motor windings, are steep voltage changes, which can initiate several destructive phenomena. The paper presents the adverse influence of a converter common mode voltage on the motor windings' increased voltage exposure and the...
-
Dual Active Bridge (DAB) DC-DC converter for multilevel propulsion converters for electrical multiple units (EMU)
PublicationSemiconductor power devices made from silicon carbide (SiC) reached a level of technology enabling their widespread use in power converters. Two different approaches to implementation of modern traction converters in electric multiple units (EMU) have been presented in recent years: (i) 3.3-kV SiC MOSFET-based three-level PWM inverter with regenerative braking and (ii) 6.5-kV IGBT-based four-quadrant power electronic traction transformer...
-
Frequency-Variant Double-Zero Single-Pole Reactive Coupling Networks for Coupled-Resonator Microwave Bandpass Filters
PublicationIn this work, a family of frequency-variant reactive coupling (FVRC) networks is introduced and discussed as new building blocks for the synthesis of coupled-resonator bandpass filters with real or complex transmission zeros (TZs). The FVRC is a type of nonideal frequency-dependent inverter that has nonzero elements on the diagonal of the impedance matrix, along with a nonlinear frequency-variation profile of its transimpedance...
-
Effect of soil moisture on current-carrying capacity of low-voltage power cables
PublicationOne of the factors affecting current-carrying capacity of underground power cables is the thermal resistivity of soil. Its value in the close proximity of the cable is the most important, and for this reason, in some cases, the local soil is replaced with an another soil type or with a cement-sand mixture. The thermal resistivity of the soil is strongly affected by moisture, and in the case of a cement-sand mixture – as tested...
-
Space-vector pulsewidth modulation for a seven-level cascaded H-bridge inverter with the control of DC-link voltages
PublicationThe control strategy of DC-link voltages for a seven-level Cascaded H-Bridge inverter is proposed in this paper. The DC-link voltage balancing is accomplished by appropriate selection of H-Bridges and control of their duty cycles in Space-Vector Modulation (SVM) algorithm. The proposed SVM method allows to maintain the same voltage level on all inverter capacitors. Regardless of the balancing function, the...
-
Failure analysis of a high-speed induction machine driven by a SiC-inverter and operating on a common shaft with a high-speed generator
PublicationDue to ongoing research work, a prototype test rig for testing high-speed motors/generators has been developed. Its design is quite unique as the two high- speed machines share a single shaft with no support bearings between them. A very high maximum operating speed, up to 80,000 rpm, was required. Because of the need to minimise vibration during operation at very high rotational speeds, rolling bearings were used. To eliminate...
-
Optical method supported by machine learning for dynamics of C‐reactive protein concentrations changes detection in biological matrix samples
PublicationIn this article we present the novel spectroscopy method supported with machine learning for real-time detection of infectious agents in wastewater. In the case of infectious diseases, wastewater monitoring can be used to detect the presence of inflammation biomarkers, such as the proposed C-reactive protein, for monitoring inflammatory conditions and mass screening during epidemics for early detection in communities of concern,...
-
CCM and DCM operation analysis of cascaded quasi-Z-source inverter
Publication -
The Method of Multi-criteria Analysis to Support the Decision on Load or Micro-generation Connection to a Low- or Medium-voltage Power Grid
PublicationThis paper presents a method that supports the decision in terms on selecting the best option of a load connection to a low- or medium-voltage power distribution grid, and of a micro-generation source connection to a low-voltage grid. The method is based on the search for the option with the lowest aggregate assessment measure, which is the weighted average of partial assessment measures determined for each of eight considered...
-
A Single-Carrier-Based Pulse-Width Modulation Template for Cascaded H-Bridge Multilevel Inverters
PublicationMultiplicity of the triangular carrier signals is a criterion for the extension of sinusoidal pulsewidth modulation, SPWM, to a number of output voltage levels per phase-leg in cascaded H-bridge (CHB) multilevel inverter (MLI). Considering medium and high voltage applications where appreciable number of output voltage levels from CHB MLI is needed, commensurate high number of carrier signals in either classical level- or phase-shifted...
-
Hybrid stepless distribution transformer with four-quadrant AC/DC/AC converter at low voltage side - simulation tests
PublicationThe article presents the work of the stepless hybrid distribution transformer (HT), as an alternative to the so far applied Automatic Voltage Regulator (AVR) solutions, used to control the voltage in the power system in terms of the fundamental harmonic. The HT is a combination of a conventional distribution transformer and an AC/DC/AC converter connected in series with the transformers secondary winding. In the work the basic...
-
Smart grid technologies in electric traction: Mini inverter station
PublicationThe growing number of trams and trolleybuses equipped with recuperation systems contribute to the increase in the amount of energy recovered during braking. It raises questions about the possibility of its usage. One of such possibilities is the use of smart grid technology. The paper presents a case study of the use of braking energy in the trolleybus system for external loads by implementing mini inverter stations. Analysis is...
-
A Simplified SVPWM Technique for Five-leg Inverter with Dual Three-phase Output
PublicationThis article proposes a simplified space vector pulse-width modulation (SVPWM) technique five-leg inverter with dual three-phase output. An idea to fed the dual tree-phase machine by the multiphase voltage source inverters (VSIs) is not new. Dual- and multi-motor drive systems are widely used in the industry applications. The most popular fields are: electric vehicles (EVs) and traction systems. Moreover, the specific characteristic...
-
Impact of power electronic Var compensators installed in certain grid points on the voltage failure
PublicationThe article presents the test results of the various types of static compensators FACTS models in the power system. The basic case, which was analyzed, it was behavior of compensators which are installed in select points of the system during voltage failure. The article presents selected results of studies conducted as part of a work [2].
-
Medium-Voltage Drives: Challenges and existing technology
PublicationThe article presents an overview of state-of-art solutions, advances, and design and research trends in medium-voltage (MV) drive technologies - and also discusses the challenges and requirements associated with the use of such drives. The choice and deployment of MV drives in industries are associated with numerous requirements related to the front-end converter (grid side) and inverter (machine side). The focus is on solutions...
-
Analytical Estimation of Power Losses in a Dual Active Bridge Converter Controlled with a Single-Phase Shift Switching Scheme
PublicationMicro-grid solutions around the world rely on the operation of DC/DC power conver- sion systems. The most commonly used solution for these topologies is the use of a dual active bridge (DAB) converter. Increasing the efficiency and reliability of this system contributes to the improvement in the stability of the entire microgrid. This paper discussed an analytical method of energy efficiency and power loss estimation in a single...
-
Voltage and Current Unbalance Reduction in Power Networks with Distributed Generation and Electric Vehicles
PublicationThe current development of prosumer microsources and the expected spread of electric vehicles may cause the appearance of significant current and voltage unbalance in low-voltage (LV) networks. This unbalance, which is an unfavorable phenomenon, may occur when using single-phase photovoltaic (PV) microsources and single-phase home chargers for electric vehicles. This paper presents a proposal for the symmetrization of the LV network...
-
Case studies of resonance phenomena in high voltage overhead power lines with shunt reactors
PublicationMisguided design of the towers of power transmission lines can lead to serious problems such as voltage asymmetry, overvoltages, electric arc extinction difficulties or resonance – in case of double circuit line with shunt reactors. The paper points out those threats on example of 400 kV double circuit overhead transmission line with shunt reactors.
-
SiC-based phase-shift dual half bridge DC-DC converter as a key component of multilevel cascaded MV converters
PublicationThe paper describes SiC-based dual half bridge (DHB) DC-DC converter considered as a key component of high frequency isolated multilevel cascaded medium voltage converters. Two topologies of bi-directional DC-DC converters: the resonant half-bridge DC-DC converter and the phase-shift DHB converter are compared in the paper. Experimental results of SiC-based 50 kHz DHB DC-DC converter are presented in the paper.