Filters
total: 296
filtered: 239
-
Catalog
Chosen catalog filters
Search results for: CALIBRATION MODEL
-
Extraction and Analysis of Bisphenols and Their Derivatives in Infant and Toddler Ready-to-feed Meals by Ultrasound-assisted Membrane Extraction Followed by LC MS/MS
PublicationThis research developed an ultrasound-assisted membrane extraction coupled with liquid chromatography-tandem mass spectrometry method for the determination of nineteen bisphenols and their derivatives in infant and toddler ready-to-feed meals. The calibration curves for all analytes were linear in the tested range, and the limit of detection and limit of quantitation were in the range 0.27 to 0.79 ng/g and 0.80 to 2.4 ng/g, respectively....
-
Levels of 13 multi-class pesticide residues in Polish honeys determined by LC-ESI-MS/MS
PublicationLevels of 13 pesticides in 40 honey samples form Poland are reported. A rapid and sensitive method was developed for the LC-ESI-MS/MS determination of multi-class pesticide residues in honey samples. Liquid-liquid extraction (LLE) on a diatomaceous earth support (requiring the use of small amounts of organic solvent), followed by chromatographic separation on a C18 column and gradient elution were employed. The method quantifies...
-
MICROCOMPASS FOR SAFE SEA NAVIGATION
PublicationThis paper presents the results of design microcompass for safe sea navigation where navigation, electronic, programming knowledge was joined to make more safe sea navigation. In first part of article presents navigation tools which using in practise. Article underlines that mostly satellite system is used to make navigation, but recommends traditional navigation method like alternative to determinate position in case of breakdown...
-
Evaluating the influence of radiative heat flux on convective heat transfer from a vertical plate in air using an improved heating plate
PublicationThis article examines the influence of radiative heat flux on the accuracy of the results of free convective heat transfer in air. In order to carry out these tests, based on the experience gained during the operation of a plate heated on one side, compensated by a reverse heat loss flux counter-heater, a unique double-sided heating sandwich plate was designed and built, consisting of three thin epoxy resin plates reinforced with...
-
Application of probabilistic tools to extend load test design of bridges prior to opening
PublicationLoad tests of bridges are widely performed in a large number of countries. Deterministic comparison of measurement results to the theoretical, FEM (finite element method)-based outcomes with possible further calibration is mostly applied. Sometimes, the data collected in the tests are also used to calibrate the reliability factors of bridge structures or their components. This work proposes to complement the stage of the load test...
-
Processing data on sea bottom structure obtained by means of the parametric sounding
PublicationThe aim of the paper is to analyze data obtained during sounding the Gdansk Bay sea bed by means of the parametric echo-sounder. The accuracy of the sea bottom structure investigation needs correct configuration of research equipment and proper calibration of peripheral devices (GPS, heading sensor, MRU-Z motion sensor and navigation instruments which provide necessary data to bathymetrical measurement system, enabling its work...
-
Processing data on sea bottom structure obtained by means of the parametric sounding
PublicationThe aim of the paper is to analyze data obtain during sounding of the Gdansk Bay by means of the parametric sonar. The accuracy of the sea bottom structure investigation needs the correct configuration of research equipment and the proper calibration of peripheral devices (GPS, heading sensor, motion sensor MRU-Z and navigation units) which provide necessary data to bathymetrical measurement system enabling its work with whole...
-
Instrumental measurement of odour nuisance in city agglomeration using electronic nose
PublicationThe paper describes an operation principle of odour nuisance monitoring network in a city agglomeration. Moreover, it presents the results of investigation on ambient air quality with respect to odour obtained during six-month period. The investigation was carried out using a network comprised of six prototypes of electronic nose and Nasal Ranger field olfactometers employed as a reference method. The monitoring network consisted...
-
Utilizing pulse dynamics for non-invasive Raman spectroscopy of blood analytes
PublicationNon-invasive measurement methods offer great benefits in the field of medical diagnostics with molecular-specific techniques such as Raman spectroscopy which is increasingly being used for quantitative measurements of tissue biochemistry in vivo. However, some important challenges still remain for label-free optical spectroscopy to be incorporated into the clinical laboratory for routine testing. In particular, non-analyte-specific...
-
The shallow sea experiment with usage of linear hydrophone array
PublicationPurpose of this article is to present designed and made linear hydrophone array and the results obtained during in situ trails on Gulf of Gdańsk. The measuring system allowed to localize hydrophones in the selected points and perform measurements in both the horizontal antenna positioning and vertical. Made in this way recordings allow creating accurate 3D imaging of sound intensity/propagation. During research three floating objects...
-
Development of an Advanced Control Algorithm for DAB DC/DC Converters: Inrush Current Limitation and Enhanced Operation in Transient States.
PublicationThe publication addresses the dynamic state challenges encountered during development of a dual active bridge (DAB) converter within DC microgrid systems. The conventional startup method is identified as instigating a cascade of unfavorable outcomes, encompassing elevated starting current, transformer current asymmetry, DC voltage distortions, EMI and heightened thermal stress on semiconductor components. Additionally, it necessitates...
-
Novel liquid chromatography method based on linear weighted regression for the fast determination of isoprostane isomers in plasma samples using sensitive tandem mass spectrometry detection
PublicationA simple, fast, sensitive and accurate methodology based on a LLE followed by liquid chromatography–tandem mass spectrometry for simultaneous determination of four regioisomers (8-iso prostaglandin F2α, 8-iso-15(R)-prostaglandin F2α, 11β-prostaglandin F2α, 15(R)-prostaglandin F2α) in routine analysis of human plasma samples was developed. Isoprostanes are stable products of arachidonic acid peroxidation and are regarded as the...
-
Determination of Selected Metals in Fruit Wines by Spectroscopic Techniques
PublicationThe determination of metals in different types of food and beverages samples has drawn significant attention due to several reasons with the most important one being the nutritional and toxic effects of these elements or their compounds. The knowledge of certain elements content in wines/fruit wines is of special interest due to their toxicity in case of excessive intake and also the effect they seem to have on the organoleptic...
-
Solid phase microextraction: state of the art, opportunities and applications
PublicationSolid phase microextraction is one of the most popular green techniques used for sample preparations in analytical chemistry. It is a simple, rapid, sensitive, and solvent-free technique. Since SPME was first introduced in the early 1990s, there has been an intensification of research in order to elaborate new methodical solutions in many research facilities around the world, which could increase the use of this technique. More...
-
In-tube extraction for the determination of the main volatile compounds in Physalis peruviana L
PublicationAn analytical procedure based on in-tube extraction followed by gas chromatography with mass spectrometry has been developed for the analysis of 24 main volatile components in cape gooseberry (Physalis peruviana L.) samples. According to their chemical structure, the compounds were organized into different groups: one hydrocarbon, one aldehyde, four alcohols, four esters, and 14 monoterpenes. By single-factor experiments, incubation...
-
In situ study of a composition of outlet gases from biogas fuelled Solid Oxide Fuel Cell performed by the Fourier Transform Infrared Spectroscopy
PublicationThe purpose of this study was to develop a method and software based on the Fourier Transform Infrared Spectroscopy for the in-situ, quantitative analysis of the composition of outlet gases from Solid Oxide Fuel Cell (SOFC). The calibration procedure performed at the beginning of the experiment indicated a polynomial dependence between the concentration of a calibrating gas (CO, CO2, CH4) and the corresponding integrated absorbance in...
-
Development of a liquid chromatography–tandem mass spectrometryprocedure for determination of endocrine disrupting compounds infish from Mediterranean rivers
PublicationA new, sensitive and rapid method based on QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe)approach followed by ultra high performance liquid chromatography coupled with tandem mass spec-trometry (UHPLC–MS/MS) was developed for the determination of nineteen endocrine disruptors (EDCs)and related compounds belonging to different classes in various fish species. Matrix effect on the analyti-cal performance was evaluated,...
-
Surveillance camera tracking of GEO positioned objects
PublicationRozdział opisuje system sterowania kamerami ruchomymi PTZ realizujący śledzenie poruszającego się obiektu o znanej pozycji GPS. Przedstawione są idea systemu oraz możliwości jego wykorzystania. Opisane są: procedura kalibracji pola widzenia kamery i sposób powiązania z danymi o lokalizacji, procedura predykcji ruchu w celu kompensacji opóźnień czasowych. Omówiony jest zaimplementowany system modułowy, w którego skład wchodzą: terminale...
-
Post processing and selecting data obtain with parametric sub-bottom profiler SES-2000 Standard during sounding the Gulf of Gdansk
PublicationThe main goal of the paper is to describe the results of sounding the Gulf of Gdansk seabed using a parametric sub-bottom profiler SES-2000 Standard. Quality of obtained during trials data depends inter alia on proper location of antenna to reduce influence of pitch, roll, heave and ship noise (bubbles from propeller and a hull flow, vibration from main engine and peripheral devices). Furthermore calibration of complementary units...
-
Capillary gas chromatography using a -cyclodextrin forenantiomeric separation of methylamphetamine, its precursors andchloro intermediates after optimization of the derivatization reaction
PublicationtThe enantiomeric ratio of methylamphetamine (MAMP) is closely related to the optical activity of precur-sors and reagents used for the synthesis and this knowledge can provide useful information concerningthe origins and synthetic methods used for illicit manufacture. The information can be utilized for reg-ulation of the precursors and investigation of the manufacturing sources but this requires analyticalprocedures to determine...
-
A method to monitor urinary carbon dioxide in patients with septic shock
PublicationSevere sepsis and septic shock are life-threatening conditions with mortality rates exceeding 31% (Levy et al., 2012) [1]. Septicemia was the most expensive US hospital condition in 2011 (Torio and Andrews, 2006)[2]. Urinary carbon dioxide may provide rapid, clinically useful information about a patient’s status, empowering physicians to intervene earlier and improve septic shock mortality. The objective of this paper is to validate...
-
Multi-layered tissue head phantoms for noninvasive optical diagnostics
PublicationExtensive research in the area of optical sensing for medical diagnostics requires development of tissue phantoms with optical properties similar to those of living human tissues. Development and improvement of in vivo optical measurement systems requires the use of stable tissue phantoms with known characteristics, which are mainly used for calibration of such systems and testing their performance over time. Optical and mechanical...
-
Investigation method of large-volume tire with mobile test rig
PublicationThe goal of this research is to develop the tire test method and mobile tire test rig. The test rig enables measurement of tire properties as stiffness and viscous damping in vertical direction, and tire–ground characteristics on the asphalt rigid surface. The tire-ground characteristics are measured by force and a torque measurement hub. The design, calibration and the algorithm for calculating the forces in the wheel center are...
-
Direction of Arrival Estimation Based on Received Signal Strength Using Two-Row Electronically Steerable Parasitic Array Radiator Antenna
PublicationIn this paper, we present a novel approach to direction-of-arrival (DoA) estimation using two-row electronically steerable parasitic array radiator (ESPAR) antenna which has 12 passive elements and allows for elevation and azimuth beam switching using a simple microcontroller, relying solely on received signal strength (RSS) values measured at the antenna output port. To this end, we thoroughly investigate all 18 available 3D antenna...
-
A fast procedure of stress state evaluation in magnetically anisotropic steels with the help of a probe with adjustable magnetizing field direction
PublicationThe paper presents a novel approach to the stress state evaluation issue. It deals with a strongly (magnetically) anisotropic materials for which a direct interpretation of the Barkhausen effect (BE) intensity would lead to erroneous results. In such a case one has to take into account both the measured BE intensity and the orientation of the magnetisation direction relative to the magnetic easy axis. For the in plane stress distribution...
-
The presence of polycyclic aromatic hydrocarbons in disposable baby diapers: A facile determination method via salting-out assisted liquid-liquid extraction coupled with gas chromatography-mass spectrometry
PublicationIn this paper we demonstrate the development of the extraction procedure of polycyclic aromatic hy- drocarbons from baby diapers along with their quantification by gas chromatography-mass spectrometry. Apart from covering plastic foil, disposable baby diapers contain sorbents intended to absorb urine and feces. A hygroscopic, adsorptive, and tough-to-homogenize fibrous sorbent, represents an analytical chal- lenge to analytical...
-
Determination of high-intensity sweeteners in beverages by high-performance liquid chromatography with mass spectrometry detection.
PublicationThe objective of the present study was to measure the concentration of nine high intensity sweeteners (acesulfame-K, aspartame, alitame, cyclamate, dulcin, neohesperidin dihydrochalcon, neotame, saccharin and sucralose) in different types of beverages available on the polish market. The proposed methodology reported here consists of a extraction with buffer composed of formic acid and N,N-diisopropylethylamine (pH 4.5) followed...
-
Simultaneous Determination of Indolic Compounds in Plant Extracts by Solid-Phase Extraction and High-Performance Liquid Chromatography with UV and Fluorescence Detection
PublicationA high-performance liquid chromatographic method with UV and fluorescence detection (HPLC-DAD-FLD) was developed for simultaneous determination of indolic compounds in plant material. Indole-3-carbinol (I3C), indole-3-acetic acid (I3AA), indole-3-acetonitrile (I3ACN), and 3,3′-diindolylmethane (DIM) were used as representative compounds that cover a wide spectrum of indole structures occurring in nature. For concentration and purification...
-
Comparison of hydrophilic interaction and reversed phase liquid chromatography coupled with tandem mass spectrometry for the determination of eight artificial sweeteners and common steviol glycosides in popular beverages
PublicationHydrophilic interaction liquid chromatography (HILIC) coupled with tandem mass spectrometry (MS/MS) was used to separate artificial and natural sweeteners approved for use in European Union (EU). Among three tested HILIC columns (BlueOrchid PAL-HILIC, Ascentis Express Si and Acclaim™ Trinity™ P2) the last one was selected for the development of HILIC method due to the best results obtained with it. Early eluting and coeluting compounds...
-
Measuring research on radio wave propagation
PublicationTelecommunication connections are increasingly based on the wireless links, both fixed and mobile, carried out under different radio systems. This kind of solution has many advantages. However, the propagation medium is a factor that causes many difficulties in designing wireless networks, because of large diversity of propagation environments. Transmission loss in each environment is determined by many variables phenomena and...
-
Stabilities of bisphenol A diglycidyl ether, bisphenol F diglycidyl ether, and their derivatives under controlled conditions analyzed using liquid chromatography coupled with tandem mass spectrometry
PublicationBisphenol A diglycidyl ether (BADGE), bisphenol F diglycydyl ether (BFDGE), and their related compounds are widely used as precursors in production of epoxy resins. The high reactivity of these compounds makes the development of analytical methodologies that ensure appropriate metrological accuracy crucial. Consequently, we aimed to determine whether and to what extent the composition of the solution and storage conditions affect...
-
Blood concentrations of a new psychoactive substance 4-chloromethcathinone (4-CMC) determined in 15 forensic cases
PublicationPurpose: The 4-chloromethcathinone (4-CMC) is a synthetic derivative of cathinone and belongs to new psychoactive substances. Neither data on the effects of 4-CMC on the human body, nor on nontoxic, toxic and lethal concentrations in biological materials have been published in the literature. This paper describes the results of an analysis of the blood concentrations of 4-CMC determined in 15 forensic cases related to nonfatal...
-
Determination of MDPBP in postmortem blood samples by gas chromatography coupled with mass spectrometry
PublicationMDPBP (1-(3,4-methylenedioxyphenyl)-2-(1-pyrrolidinyl)-1-butanone) is a new psychoactive substance sold on the black market. It has been a controlled drug of abuse in Poland and China since 2015 as some toxic and fatal cases connected with use of synthetic cathinone derivatives were observed. The fatal case outlined here concerns a 19 year-old man, who was found dead with an envelope containing white powder lying nearby the cadaver....
-
Development and validation of a method for the simultaneous analysis of fatty acid ethyl esters, ethyl sulfate and ethyl glucuronide in neonatal meconium: application in two cases of alcohol consumption during pregnancy
PublicationAlcohol consumption during pregnancy constitutes one of the leading preventable causes of birth defects and neurodevelopmental disorders in the exposed children. Fatty acid ethyl esters (FAEEs), ethyl glucuronide (EtG) and ethyl sulfate (EtS) have been studied as potential biomarkers of alcohol consumption. However, most analytical approaches proposed for their analysis in meconium samples consist of separated extraction procedures...
-
An adaptive-noise Augmented Kalman Filter approach for input-state estimation in structural dynamics
PublicationThe establishment of a Digital Twin of an operating engineered system can increase the potency of Structural Health Monitoring (SHM) tools, which are then bestowed with enhanced predictive capabilities. This is particularly relevant for wind energy infrastructures, where the definition of remaining useful life is a main driver for assessing the efficacy of these systems. In order to ensure a proper representation of the physical...
-
Stanowisko do diagnostyki i regulacji wyzwalaczy przekaźników w obwodach lokomotyw elektrycznych
PublicationFast circuit breaker and protective relays play an important role of protecting locomotive’s electrical circuits from damage caused by short circuit or overload. Undisturbed operation and proper circuit protection depends on the technical condition and fine calibration of the over-current trips. Therefore the relays should be subject to periodic inspection and adjustment due to locomotive maintenance schedule. A test stand for...
-
Determination of nine high-intensity sweeteners in various foods by high-performance liquid chromatography with mass spectrometric detection
PublicationAn analytical procedure involving solid-phase extraction (SPE) and high-performance liquid chromatography-mass spectrometry has been developed for the determination of nine high-intensity sweeteners authorised in the EU; acesulfame-K (ACS-K), aspartame (ASP), alitame (ALI), cyclamate (CYC), dulcin (DUL), neohesperidin dihydrochalcone (NHDC), neotame (NEO), saccharin (SAC) and sucralose (SCL) in a variety of food samples (i.e. beverages,...
-
Validation and modification of HPLC method for monitoring acetaminophen plasma concentrations in patients with chronic pancreatitis
PublicationBackground. Pancreatitis is the inflammation of the pancreas. The infl ammation may occur suddenly and resolve in a few days with the treatment in case of acute pancreatitis (AP). Chronic pancreatitis (CP) is a persistent inflammation of the pancreas that results in irreversible morphological changes and impairment of both exocrine and endocrine functions. Abdominal...
-
Rapid and simple multi-analyte LC–MS/MS method for the determination of benzodiazepines and Z-hypnotic drugs in blood samples: Development, validation and application based on three years of toxicological analyses
PublicationBenzodiazepines (BZDs) and Z-drugs have been particularly important treatments for sleeping and anxiety disorders for many years. However, recently, a number of new benzodiazepines (named designer benzodiazepines, DBZDs) were synthesised, but some of them have never been used in the clinic; they reached the black drug market as new psychoactive substances and are used for recreational purposes. The abuse of these substances has...