Filters
total: 1094
filtered: 849
-
Catalog
Chosen catalog filters
Search results for: passive LC filter
-
Limitations of Integrative Passive Samplers as a Tool for the Quantification of Pharmaceuticals in the Environment – A Critical Review with the Latest Innovations
Publication -
A Multichannel Receiver of the Experimental FM Based Passive Radar Using Software Defined Radio Technology
Publication -
Estimating Traffic Intensity Employing Passive Acoustic Radar and Enhanced Microwave Doppler Radar Sensor
PublicationInnovative road signs that can autonomously display the speed limit in cases where the trac situation requires it are under development. The autonomous road sign contains many types of sensors, of which the subject of interest in this article is the Doppler sensor that we have improved and the constructed and calibrated acoustic probe. An algorithm for performing vehicle detection and tracking, as well as vehicle speed measurement,...
-
Comparing traffic intensity estimates employing passive acoustic radar and microwave Doppler radar sensor
PublicationThe purpose of our applied research project is to develop an autonomous road sign with built-in radar devices of our design. In this paper, we show that it is possible to calibrate the acoustic vector sensor so that it can be used to measure traffic volume and count the vehicles involved in the traffic through the analysis of the noise emitted by them. Signals obtained from a Doppler radar are used as a reference source. Although...
-
Molecular interaction sensors: a new detector platform for separation methods
PublicationPotencjometria jest nową metodą detekcji dla chromatografii cieczowej (LC)i elektroforezy kapilarnej (CE). Zastosowanie potencjometrii dla chromatograficznych technik wynika z faktu, że sygnał z detektora jest zależny od stanu rozdzielenia analitów nad pokryciem sensora i od rodzaju eluentu. Rozdzielenie analitu powoduje zmiany potencjału, a zmiany te można zaklasyfikować jako potencjometryczne. Do opisu ilościowego potrzebny jest...
-
Determining pesticide contamination in honey by LC-ESI-MS/MS - Comparison of pesticide recoveries of two liquid-liquid extraction based approaches
PublicationHoney, a valuable food product, may be contaminated by xenobiotics during its production and/or harvest. The determination of trace levels of contaminants in a complex matrix like honey still presents a challenge to analytical chemists. The aim of this work was to assess and compare the extraction efficiencies of 30 pesticide residues (acaricides, insecticides, herbicides, fungicides), belonging to over 15 different chemical classes....
-
Extraction and Analysis of Bisphenols and Their Derivatives in Infant and Toddler Ready-to-feed Meals by Ultrasound-assisted Membrane Extraction Followed by LC MS/MS
PublicationThis research developed an ultrasound-assisted membrane extraction coupled with liquid chromatography-tandem mass spectrometry method for the determination of nineteen bisphenols and their derivatives in infant and toddler ready-to-feed meals. The calibration curves for all analytes were linear in the tested range, and the limit of detection and limit of quantitation were in the range 0.27 to 0.79 ng/g and 0.80 to 2.4 ng/g, respectively....
-
Self-adjusting sub-sample delay estimator based on fractional delaying Hilbert transform filter
PublicationZaprezentowano nowe rozwiązanie samo-nastrajalnego estymatora opóźnienia sygnału sinusoidalnego, działającego w czasie dyskretnym. Zastosowano filtr Hilberta o skończonej odpowiedzi ipulsowej (FIR od ang. finite impulse response) zagregowany z filtrem ułamkowo-opóźniającym. Zilustrowano performancję estymatora, również w obecności szumu. Przeanalizowano jego złożoność numeryczną.
-
Short review on the design and application of fractionl delay Hilbert transform filter using Farrow structure
PublicationThis paper is treated as a brief summary of our hitherto research on the design and utilization of the FDHTF, particularly in the sub-samole delay estimator.
-
High dimensional Bio medical images denoising using wavelet transform and modified bilateral filter
Publication -
The usefulness of ascorbic acid degradation to analyze the effectiveness of water filtration in household water filter jugs
Publication -
Lattice filter based autoregressive spectrum estimation with joint model order and estimation bandwidth adaptation
PublicationThe problem of parametric, autoregressive model based estimation of a time-varying spectral density function of a nonstationary process is considered. It is shown that estimation results can be considerably improved if identification of the autoregressive model is carried out using the two-sided doubly exponentially weighted lattice algorithm which combines results yielded by two one-sided lattice algorithms running forward in...
-
New possibilities of the passive layer cracking dynamics detection using a new Dynamic Electrochemical Impedance Spectroscopy.
PublicationNowa metoda Dynamicznej Elektrochemicznej Spektroskopii Impedancyjnej opracowana w Katedrze Elektrochemii, Korozji i Inżynierii Materiałowej Politechniki Gdańskiej daje możliwości określania charakterystyki impedancyjnej w dziedzinie czasu podczas procesu pękania ochronnej warstwy pasywnej. Fakt ten jest związany z procedurą analizującą wspomnianej techniki, która umożliwia selektywną analizę czasowo-częstotliwościową uzyskanych...
-
Employment of passive sampling in monitoring indoor air quality in selected residences in a Tri-city area in Poland
PublicationNa etapie pobierania próbek analitów zastosowano dwie techniki: pasywną - wykorzystującą permeacyjne dozymetry pasywne oraz technikę klasyczną - wykorzystującą rurki sorpcyjne. Wyznaczono sumaryczną zawartość TVOC lotnych związków organicznych.
-
Wykorzystanie dozymetrów pasywnych w analityce zanieczyszczeń wody = Use of passive dosimeters in analysis of water pollution
PublicationDozymetry pasywne stanowią coraz powszechniej wykorzystywane narzędzie do pobierania próbek analitów ze środowiska wodnego. W pracy opisano podstawy teoretyczne działania dozymetrów pasywnych oraz czynniki wpływające na szybkość pobierania próbek analitów z wody. Przedstawiono również charakterystykę oraz omówiono obszar praktycznego zastosowania wybranych typów próbników pasywnych.
-
Application of the PASSIL technique for the passive sampling of exemplary polar contaminants (pharmaceuticals and phenolic derivatives) from water
Publication -
Developments in Green Chromatography
PublicationGreen analytical chemistry is a widely recognized concept that has led to the development of new analytical methods with reduced environmental impact and minimized analyst occupational exposure. Achievements include the development of microextraction, ultrasound-assisted extraction (UAE), and microwave-assisted extraction (MAE) techniques. Research towards greener separation processes focuses on the elimination of toxic solvents...
-
Concentration of Potentially Bioactive Compounds in Italian Extra Virgin Olive Oils from Various Sources by Using LC-MS and Multivariate Data Analysis
PublicationHigh quality extra virgin olive oils represent an optimal source of nutraceuticals. The European Union (EU) is the world’s leading olive oil producer, with the Mediterranean region as the main contributor. This makes the EU the greatest exporter and consumer of olive oil in the world. However, small olive oil producers also contribute to olive oil production. Beneficial effects on human health of extra virgin olive oil are well...
-
Microstrip line with short-circuited edge as a high-pass filter operating up to millimeter-wave frequencies
PublicationPrzedstawiono prosty planarny filtr górnoprzepustowy wykorzystujący linię mikropaskową ze zwartym brzegiem. Układy zaprojektowano w taki sposób, aby pasmo przepustowe rozpoczynało się w zakresie K lub Ka. Wykonano dwa prototypy: na podłożu w postaci warstwy dielektrycznej wykonanej z ceramiki alundowej oraz na podłożu organicznym o niskiej przenikalności elektrycznej. Wykazano dużą zgodność teoretycznych i pomierzonych charakterystyk...
-
Fifth-order low-pass CMOS OTA-C continuous-time filter with on-chip automatic tuning
PublicationW pracy przedstawiono budowę operacyjnego wzmacniacza transkonduktancyjnego (OTA) zasilanego napięciem stałym 2.8-4.5V wykonanego w technologii CMOS0.8um n-well. Wzmacniacz ten wykorzystano do budowy dolnoprzepustowego filtru czasu ciągłego typu OTA-C piątego rzędu. W układzie scalonym umieszczono także blok automatycznego dostrajania częstotliwości odcięcia filtru. Przedstawiono wyniki symulacji komputerowych (modele MOS BSIM3v3)...
-
Filter-Hilbert Method for Automatic Correction of Non-Anechoic Antenna Measurements with Embedded Self-Calibration Mechanism
PublicationOne of the most important steps in the process of antenna development involves measurements of its prototype. Far-field performance of radiators is normally characterized in strictly controlled environments such as anechoic chambers which can ensure certification-grade accuracy. Unfortunately, they are also characterized by high construction costs which might not be justified for low-budget research and/or teaching-related activities....
-
Toward Wide-Band High-Resolution Analog-to-Digital Converters Using Hybrid Filter Bank Architecture
Publication -
Estimation of time-frequency complex phase-based speech attributes using narrow band filter banks
PublicationIn this paper, we present nonlinear estimators of nonstationary and multicomponent signal attributes (parameters, properties) which are instantaneous frequency, spectral (or group) delay, and chirp-rate (also known as instantaneous frequency slope). We estimate all of these distributions in the time-frequency domain using both finite and infinite impulse response (FIR and IIR) narrow band filers for speech analysis. Then, we present...
-
Stability of softly switched multiregional dynamic output controllers with a static antiwindup filter: A discrete-time case
PublicationThis paper addresses the problem of model-based global stability analysis of discrete-time Takagi–Sugeno multiregional dynamic output controllers with static antiwindup filters. The presented analyses are reduced to the problem of a feasibility study of the Linear Matrix Inequalities (LMIs), derived based on Lyapunov stability theory. Two sets of LMIs are considered candidate derived from the classical common quadratic Lyapunov...
-
MATCHED FILTER APPROACH FOR MICROSEISMIC SIGNAL PROCESSING OF REAL DATA FROM EAST POMERANIA SHALE GAS
PublicationThe microseismic monitoring is a method of monitoring of fracture propagation during hydraulic fracturing (HF)process. An array of several hundred geophones is placed on the surface to record little ground tremors induced by fracturing process. Filtration and summation of signals from geophones is essential to identify and locate fracturing events from underground. Authors propose a method of matched filtering, that is usually...
-
Compact, Order Extensible and Wide-Stopband Bandpass Filter Based on SIW Cavity with Rectangular Ring Slot
PublicationThis article introduces novel architectures of bandpass filters (BPFs) using a substrate integrated waveguide (SIW) cavity with a rectangular ring slot (RRS) for compact size, extensible order, and broad stopband responses. Two bandpass filters, which demonstrate a second-and a fourth-order Chebyshev response, respectively, are realized by employing identical cavities with RRS, without increasing the physical size of the circuit....
-
Lattice filter based multivariate autoregressive spectral estimation with joint model order and estimation bandwidth adaptation
PublicationThe problem of parametric, autoregressive model based estimation of a time-varying spectral density function of a multivariate nonstationary process is considered. It is shown that estimation results can be considerably improved if identification of the autoregressive model is carried out using the two-sided doubly exponentially weighted lattice algorithm which combines results yielded by two one-sided lattice algorithms running...
-
Comparative electrochemical analysis of the passive layer cracking process on aluminum alloys performed by means of DC and AC techniques
PublicationZbadano proces pękania warstwy pasywnej na stopach aluminium AA1050, AA5052, AA5056, oraz AA7005 w warunkach zmiennych naprężeń rozciągających i polaryzacji anodowej z wykorzystaniem techniki stałoprądowej, DEIS oraz emisji akustycznej (AE), jako metody porównawczej. Przeprowadzone badania pokazały przewagę techniki DEIS oraz emisji akustycznej nad klasyczną techniką stałoprądową. Wyznaczono dokładny moment pęknięcia warstwy pasywnej...
-
Electrochemical analysis of the passive layer cracking process on A95052 aluminium alloy performed by means of DC and AC techniques
PublicationPraca dotyczy porównania zastosowania technik stało- i zmiennoprądowych do badania pękania warstwy pasywnej na różnych stopach aluminum podczas testów rozciągania mechanicznego w warunkach polaryzacji anodowej.
-
Impact of humic acids, temperature and stirring on passive extraction of pharmaceuticals from water by trihexyl(tetradecyl)phosphonium dicyanamide
Publication -
Preliminary study on suitability of ionic liquids as potential passive-sampling media of polyaromatic-hydrocarbon (PAH) analyses in water
Publication -
DEM analysis of micro-structural events within granular shear zones under passive earth pressure conditions
PublicationW artykule omówiono wyniki obliczeń numerycznych dla pasku dla stanu pasywnego sztywnej ścianki podczas jej translacji stosując metodę elementów dyskretnych. Analizowano głównie zjawiska mikrostrukturalne w strefach ścinania podczas translacji sztywnej ścianki. Szczególna uwagę zwrócono na pojawienie się wirów w materiale granulowanym.
-
Plant-based meat substitute analysis using microextraction with deep eutectic solvent followed by LC-MS/MS to determine acrylamide, 5-hydroxymethylfurfural and furaneol
PublicationFor the analysis of plant-based meat substitutes and the determination of Maillard reaction products such as acrylamide, 5-hydroxymethylfurfural and furaneol, a novel and effective procedure based on hydrophobic natural deep eutectic solvent and liquid chromatography coupled with tandem mass spectrometry was developed for the first time. The 49 compositions of the deep eutectic solvents were designed and screened to select the...
-
A multi-pulse diode rectifier with a coupled three-phase reactor and additional small shunt active power filter
Publication -
Supply system based on the 18-pulse diode rectifier with coupled reactors and integrated with the series active power filter
Publication -
Design of Highly Selective Dual Band Band Stop Filter using Dual-Path Step Impedance Resonator
Publication -
Signal Receiving and Processing Platform of the Experimental Passive Radar for Intelligent Surveillance System Using Software Defined Radio Approach
Publication -
A diode rectifier with a Special Coupled Reactor and additional Active Power Filter in the Marine Local Power Network Supply Conditions
Publication -
Preparation and evaluation of 1,3-alternate 25,27-bis[p-nitrobenzyloxy]-26,28-bis[3-propyloxy]-calix[4]arene-bonded silica gel stationary phase for LC
PublicationPrzeprowadzono syntezę nowej fazy stacjonarnej na bazie sililowej pochodnej 25,27-bis[p-nitrobenzyloksy]-26,28-bis-[3-propyloksy]kaliks[4]arenu zablokowanego w konformacji 1,3-naprzemianległej. Zbadano selektywność i sprawność fazy w stosunku do szeregu klas związków organicznych techniką wysokosprawnej chromatografii cieczowej.
-
Selectivity Tuning by Natural Deep Eutectic Solvents (NADESs) for Extraction of Bioactive Compounds from Cytinus hypocistis—Studies of Antioxidative, Enzyme-Inhibitive Properties and LC-MS Profiles
PublicationIn the present study, the extracts of Cytinus hypocistis (L.) L using both traditional solvents (hexane, ethyl acetate, dichloromethane, ethanol, ethanol/water, and water) and natural deep eutectic solvents (NADESs) were investigated in terms of their total polyphenolic contents and antioxidant and enzyme-inhibitive properties. The extracts were found to possess total phenolic and total flavonoid contents in the ranges of 26.47–186.13...
-
Spatial and seasonal patterns of benzene, toluene, ethylbenzene, and xylenes in the Gdańsk, Poland and surrounding areas determined using Radiello passive samplers
PublicationCelem badań było uzyskanie informacji o poziomie zanieczyszczeń powietrza atmosferycznego przez związki z grupy BTEX na terenie aglomeracji Trójmiejskiej z wykorzystaniem techniki dozymetrii pasywnej na etapie pobierania próbek analitów. Próbniki pasywne Radiello były poddawane ekspozycji na stacjach pomiarowych zarządzanych przez fundację ARMAAG, zlokalizowanych na terenie aglomeracji Trójmiejskiej.Otrzymane informacje analityczne...
-
Experimental and Computational Fluid Dynamics Studies on Straight and U-Bend Double Tube Heat Exchangers with Active and Passive Enhancement Methods
PublicationIn this work, the authors wanted to demonstrate the possibility to increase the heat transfer efficiency by using simple wire coil inserts to create turbulent flow in the boundary layer as well as air blowing into the annulus of the pipe. Experimental investigations were carried out for four heat exchanger constructions, i.e., plain double tube, turbulized double tube, plain U-bend double tube, U-tube with turbulator, plain double...
-
Zastosowanie techniki dozymetrii pasywnej do oceny jakości powietrza wewnętrznego. Application of passive sampling technique for assessment of indoor air quality
PublicationJakość powietrza wewnętrznego jest istotnym parametrem wpływającym na dobre samopoczucie i zdrowie człowieka. Kluczowego znaczenia nabiera więc jego nieustanna kontrola i oznaczanie zawartości zanieczyszczeń, które występują w nim na bardzo niskich poziomach stężeń. Do pomiarów jakości powietrza wewnętrznego często wykorzystywana jest (znana od ponad pół wieku) technika dozymetrii pasywnej. W literaturze nadal pojawiają się doniesienia...
-
Rapid and simple multi-analyte LC–MS/MS method for the determination of benzodiazepines and Z-hypnotic drugs in blood samples: Development, validation and application based on three years of toxicological analyses
PublicationBenzodiazepines (BZDs) and Z-drugs have been particularly important treatments for sleeping and anxiety disorders for many years. However, recently, a number of new benzodiazepines (named designer benzodiazepines, DBZDs) were synthesised, but some of them have never been used in the clinic; they reached the black drug market as new psychoactive substances and are used for recreational purposes. The abuse of these substances has...
-
Analysis of electrochemical parameters in time domain during the passive layer cracking occurring on the 304L stainless steel in chlorides solution under tensile stresses
Publication -
Analysis of electrochemical parameters in time domain during the passive layer cracking occurring on the 304L stainless steel in chlorides solution under tensile stresses.
PublicationDynamiczna Elektrochemiczna Spektroskopia Impedancyjna została wykorzystana do szczegółowej analizy zakresu przejścia stan pasywny - stan aktywny podczas procesu pękania warstwy pasywnej. Wpływ potencjału oraz naprężeń mechanicznych na niszczenie warstwy ochronnej występującej na stali 304L w środowisku 0.5M NaCl w pokojowej temperaturze został przestudiowany. Praca prezentuje chwilowe widma impedancyjne uzyskane przy różnych warunkach...
-
Levels of hemoglobin and lipid peroxidation metabolites in blood, catalase activity in erythrocytes and peak expiratory flow rate in subjects with passive exposure to tobacco smoke
Publication -
Recent advances of selected passive heat transfer intensification methods for phase change material-based latent heat energy storage units: A review
PublicationThe following article overviews recent studies regarding heat transfer enhancement methods, explicitly focusing on fins and coils utilization, in phase change material-based latent heat thermal energy storage systems. It discusses the influence of various geometrical and material parameters on the melting and solidification processes, as well as the orientation of the heat transfer surface within the storage tank. Additionally,...
-
Profile and Content of Phenolic Compounds in Leaves, Flowers, Roots, and Stalks of Sanguisorba officinalis L. Determined with the LC-DAD-ESI-QTOF-MS/MS Analysis and Their In Vitro Antioxidant, Antidiabetic, Antiproliferative Potency
Publication -
The effect of strain rate on the passive layer cracking of 304L stainless steel in chloride solutions based on the differential analysis of electrochemical parameters obtained by means of DEIS
PublicationOkreślono wpływ szybkości rozciągania w zakresie 10-5s-1 ÷ 16∙10-5s-1 na niestacjonarny proces elektrochemiczny pękania warstwy pasywnej. Badania przeprowadzono na stali wysokostopowej 304L w temperaturze pokojowej w środowisku chlorków za pomocą dynamicznej elektrochemicznej spektroskopii impedancyjnej (DEIS). W rezultacie uzyskano zestaw chwilowych widm impedancyjnych odzwierciedlających dynamikę badanego układu korozyjnego....