Filters
total: 81
Search results for: DC COMPONENT
-
Behavior of residual current devices at earth fault currents with DC component
PublicationLow-voltage electrical installations are increasingly saturated with power electronic converters. Due to very high popularity of photovoltaic (PV) installations and the spread of electric vehicles (EV) as well as their charging installations, DC–AC and AC–DC converters are often found in power systems. The transformerless coupling of AC and DC systems via power electronic converters means that an electrical installation containing...
-
Tripping of F-type RCDs for sinusoidal residual current with superimposed smooth DC component
PublicationRecent trends in green energy development make that photovoltaics and electric vehicles are applied on an increasing scale. In both photovoltaic and electric vehicle charging installations, a significant value of DC component of the earth fault current may appear, which is a challenge, in particular, for commonly used residual current devices (RCDs). This paper presents results of the laboratory test on the operation of F-type...
-
SiC-based phase-shift dual half bridge DC-DC converter as a key component of multilevel cascaded MV converters
PublicationThe paper describes SiC-based dual half bridge (DHB) DC-DC converter considered as a key component of high frequency isolated multilevel cascaded medium voltage converters. Two topologies of bi-directional DC-DC converters: the resonant half-bridge DC-DC converter and the phase-shift DHB converter are compared in the paper. Experimental results of SiC-based 50 kHz DHB DC-DC converter are presented in the paper.
-
Cost-Effective Piggyback Forward dc-dc Converter
PublicationThe novel piggyback dc-dc converter as a cost-effective solution is presented in this work. It provides a wide input voltage range of regulation with a low component count. The novel solution is an advanced forward dc-dc converter with an additional clamp output capacitor. The idea of such a type of converter is to transfer magnetizing energy of transformer to the output side, instead of using input clamp circuit. The design guidelines...
-
Implementation of constant component filter in measurements of random telegraph signal noise
PublicationNoise is generated in all semiconductor devices. The intensity of these fluctuations depends on used elements, manufacturing process, operating conditions and device type. The result noise is a superposition of different kinds of fluctuations like thermal noise, generation-recombination noise, 1/f noise, shot noise and Random Telegraph Signal (RTS) noise. The last one, RTS noise is observed as nonstationary impulse fluctuations....
-
RCDs Tripping in the Range from DC to AC 50 kHz for Slowly Rising Residual Current
PublicationThe wide use of power electronic converters means that in many low-voltage systems earth fault currents containing components from DC to AC of various frequencies have to be taken into account. Due to the tendency to increase the modulation frequency in converters, components of higher frequencies may be in the order of several tens of kilohertz. Therefore, it is very important to verify the behavior of devices for protection against...
-
Residual current devices in electric vehicles charging installations
PublicationThe main requirements of national regulations and international standards regarding protection against electric shock in electric vehicle charging installations are presented. The principles of using residual current devices (RCDs) in such installations are discussed. It is pointed out that RCDs are mandatory equipment for safe charging of electric vehicles. It is noted that the standards require the use of RCDs having an appropriate...
-
Cascaded Buck Hybrid Interlink Converter for Multiple-Input / Multiple-Output Operation
PublicationThe provision of isolated- and non-isolated DC output voltages by Power electronics power-conditioning devices in the recent ‘green-energy-revolution’ era is on course. In this paper, a structure for multi-input multi-output(MIMO) DC–DC buck converter is proposed to generate output voltages of varying levels with fewer component-count. The DC output voltage of each of the constituting buck converters can be used independently or...
-
Comparison of Impedance-Source Networks for Two and Multilevel Buck–Boost Inverter Applications
Publicationmpedance-source networks are an increasingly popular solution in power converter applications, especially in single-stage buck-boost power conversion to avoid additional front-end dc-dc power converters. In the survey papers published, no analytical comparisons of different topologies have been described, which makes it difficult to choose the best option. Thus, the aim of this paper is to present a comprehensive analytical comparison...
-
Jednofazowy falownik napięcia z aktywnym obwodem odsprzęgającym
PublicationZnanym zagadnieniem w jednofazowych falownikach napięcia jest pobieranie ze źródła napięcia stałego składowej przemiennej o częstotliwości dwukrotnie większej od częstotliwości generowanej przez falownik. Jednym z rozwiązań problemu jest stosowanie dużej baterii kondensatorów elektrolitycznych, lecz lepszym sposobem z punktu widzenia niezawodności i gęstości mocy przekształtnika jest stosowanie aktywnych układów odsprzęgania mocy....
-
Analytical fluctuation enhanced sensing by resistive gas sensors
PublicationResistance fluctuations across polarised resistive gas sensors were studied in detail to evaluate sensor working conditions for detecting methane and ammonia at various concentrations. The 1/f noise component typically dominates other noise sources up to a few kHz and can be utilised to improve gas selectivity when compared with measurements of the sensor DC resistance. The Arrhenius plot was created and the activation energy for...
-
Assessment of Fuel Cells’ State of Health by Low-Frequency Noise Measurements
PublicationWe proposed applying low-frequency (flicker) noise in proton-exchange membrane fuel cells under selected loads to assess their state of health. The measurement set-up comprised a precise data acquisition board and was able to record the DC voltage and its random component at the output. The set-up estimated the voltage noise power spectral density at frequencies up to a few hundred mHz. We observed the evolution of the electrical...
-
Effects of UV light irradiation on fluctuation enhanced gas sensing by carbon nanotube networks
PublicationThe exceptionally large active surface-to-volume ratio of carbon nanotubes makes it an appealing candidate for gas sensing applications. Here, we studied the DC and low-frequency noise characteristics of a randomly oriented network of carbon nanotubes under NO2 gas atmosphere at two different wavelengths of the UV light-emitting diodes. The UV irradiation allowed to sense lower concentrations of NO2 (at least 1 ppm) compared to...
-
Collection Efficiency in Narrow Electrostatic Precipitators with a Longitudinal or Transverse Wire Electrode
PublicationRecently narrow electrostatic precipitators (ESPs) have become a subject of interest because of their possible application in diesel engine exhaust systems. In this work, results of particle collection efficiency measurements in narrow electrostatic precipitators for negative and positive dc voltage polarity are presented. The ESP usedin this work was a parallelepiped equipped with wire discharge electrode and two collecting plate-electrodes....
-
Accurate modeling of quasi-resonant inverter fed IM drive
PublicationIn this paper wide-band modeling methodology of a parallel quasi-resonant dc link inverter (PQRDCLI) fed induction machine (IM) is presented. The modeling objective is early-design stage prediction of conductive electromagnetic interference (EMI) emissions of the considered converter fed IM drive system. Operation principles of the selected topology of PQRDCLI feeding IM drive are given. Modeling of the converter drive system is...
-
The Influence of a Photovoltaic Micro-Installation on the Low-Frequency Parameters of Electricity at PCC and Its Impact on the Thermal Characteristics of Selected Devices
PublicationThis manuscript illustrates the measurement results of parameters describing the quality of energy at the PCC (point of common coupling) of a photovoltaic micro-installation that can significantly affect devices in the same power grid. The analyses reflecting heating of selected devices used in domestic installations, which were performed in an isolated laboratory environment, are also indicated. The conducted study aimed at checking...
-
Experimental investigation of the weight averaging of pulse frequency modulated sensor output signal
Open Research DataThe research aims to practically verify the results of theoretical analysis and simulations of the efficiency of weight averaging of pulse frequency modulated signal. For this purpose, a suitable test stand was built, and the control software in the LabVIEW environment was prepared. Then, a series of experiments were carried out to process and analyze...
-
Metamaterial-Based Sub-Microwave Electromagnetic Field Energy Harvesting System
PublicationThis paper presents the comprehensive analysis of the sub-microwave, radio frequency band resonant metastructures’ electromagnetic properties with a particular emphasis on the possibility of their application in energy harvesting systems. Selected structures based on representative topologies of metamaterials have been implemented in the simulation environment. The models have been analyzed and their substitute average electromagnetic...
-
Detekcja i lokalizacja nieprzewodzenia tranzystorów falownika napięcia na podstawie analizy prądu obciążenia
PublicationPrzedstawiono nową metodę detekcji i lokalizacji nieprzewodzenia tranzystorów w falownikach napięcia zasilających silniki indukcyjne małej mocy. Metoda bazuje na monitorowaniu wartości dwóch sygnałów dia-gnostycznych. Pierwszy z nich, wskaźnik braku przepływu prądu, wykorzystano w celu detekcji uszkodzeń. Drugi, stosunek wartości średniej prądu do wartości średniej bezwzględnej, zawiera informacje umożliwiające lokalizację uszkodzonych...
-
Changes on the Surface of the SiO2/C Composite, Leading to the Formation of Conductive Carbon Structures with Complex Nature of DC Conductivity
Open Research DataChanges on the Surface of the SiO2/C Composite, Leading to the Formation of Conductive Carbon Structures with Complex Nature of DC Conductivity
-
Testing impedance analyzer with potentiostat using RC model with Si diode at 200 mV
Open Research DataThe dataset presents impedance spectrum non-linear RC model with diode presented in the figure below. This model was used as a test engine of the impedance analyzer with potentiostat described in the referenced paper. When changing the DC polarisation of the model the non-linear phenomena could be observed. Thanks to this, the model can be used as a...
-
Testing impedance analyzer with potentiostat using RC model with Si diode at 0 V
Open Research DataThe dataset presents impedance spectrum non-linear RC model with diode presented in the figure below. This model was used as a test engine of the impedance analyzer with potentiostat described in the referenced paper. When changing the DC polarisation of the model the non-linear phenomena could be observed. Thanks to this, the model can be used as a...
-
Testing impedance analyzer with potentiostat using RC model with Si diode at 600 mV
Open Research DataThe dataset presents impedance spectrum non-linear RC model with diode presented in the figure below. This model was used as a test engine of the impedance analyzer with potentiostat described in the referenced paper. When changing the DC polarisation of the model the non-linear phenomena could be observed. Thanks to this, the model can be used as a...
-
Testing impedance analyzer with potentiostat using RC model with Si diode at 400 mV
Open Research DataThe dataset presents impedance spectrum non-linear RC model with diode presented in the figure below. This model was used as a test engine of the impedance analyzer with potentiostat described in the referenced paper. When changing the DC polarisation of the model the non-linear phenomena could be observed. Thanks to this, the model can be used as a...
-
Output voltage, current and DC-link voltages under SVPWM, experimental results
Open Research DataThe dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The output line-to-line voltage, output current and DC-link voltages were included. The comparison studies between proposed Space Vector Pulse-Width...
-
Output voltage, current and DC-link voltages under SPWM, experimental results
Open Research DataThe dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The output line-to-line voltage, output current and DC-link voltages were included. The Carrier-Based Pulse-Width Modulation (CBPWM) technique was...
-
Electrochemical cell impedance spectra at Eoc+100mV
Open Research DataThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc+200mV
Open Research DataThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc-100mV
Open Research DataThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc
Open Research DataThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc-200mV
Open Research DataThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Dual drive control under SVPWM, experimental results
Open Research DataThe dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The analysis includes the behaviour of the drive system, examining the dynamic system response to speed and angle changes, and encompassing data...
-
Electrical and noise responses of graphene back-gated field-effect transistors enhanced by UV light for organic vapors sensing
Open Research DataBack-gated field-effect transistors with graphene channels (GFETs) were investigated toward organic vapors sensing. Two methods were used for sensing experiments including DC characteristics measurements and fluctuation-enhanced sensing by low-frequency noise studies. The data set consists of raw and modified data on GFET responses to acetonitrile,...
-
Long-term measurements from a photovoltaic power plant and meteorological stations at the Laboratory LINTE^2 of Gdańsk University of Technology
Open Research Data1) The Laboratory LINTE^2 is a large research infrastructure operated by the Faculty of Electrical and Control Engineering at Gdańsk University of Technology, to be found in Gdańsk, Poland (54.3690 N, 18.6130 E). 2) The measurements have been collected from a photovoltaic power plant located on the roof of the laboratory, having total capacity...
-
Electrical conductivity of the Sr0.86Ti0.65Fe0.35O3-d pellet at different oxygen partial pressures
Open Research DataThis dataset contains results electrical conductivity measurements of dense Sr0.86Ti0.65Fe0.35O3-d (STF35) pellet. DC electrical conductivity measurements of STF35 were performed by the Van der Pauw method. Studies were performed at different oxygen partial pressures (20%, 1% and 0.1%) under humidified (~4 vol%) gas flow rate of 50 ml min -1.
-
Electrical conductivity of the SrTi1-xFexO3-d pellets at 20% pO2
Open Research DataThis dataset contains results electrical conductivity measurements of dense SrTi1-xFexO3-d (x=0.35, 0.50, 0.70) pellets. DC electrical conductivity measurements were performed by the Van der Pauw method between 900 °C and 200 °C. Studies were performed at 20% of oxygen partial pressure under humidified (~4 vol%) gas flow rate of 50 ml min -1.
-
Low temperature electrical conductivity of the SrFeO3-d pellet
Open Research DataThis dataset contains results of low temperature electrical conductivity measurements of dense SrFeO3-d (SFO) pellet. DC electrical conductivity measurements of SFO were performed by the Van der Pauw method between 400 °C and room temperature with 20 °C step. Studies were performed at Synthetic Air flow under humidified (~4 vol%) gas flow rate of 40...
-
Low temperature electrical conductivity of the SrTi0.65Fe0.35O3-d pellet
Open Research DataThis dataset contains results of low temperature electrical conductivity measurements of dense SrTi0.65Fe0.35O3-d (STF35) pellet. DC electrical conductivity measurements of STF35 were performed by the Van der Pauw method between 400 °C and room temperature with 20 °C step. Studies were performed at Synthetic Air flow under humidified (~4 vol%) gas...
-
Low temperature electrical conductivity of the SrTi0.30Fe0.70O3-d pellet
Open Research DataThis dataset contains results of low temperature electrical conductivity measurements of dense SrTi0.30Fe0.70O3-d (STF70) pellet. DC electrical conductivity measurements of STF70 were performed by the Van der Pauw method between 400 °C and room temperature with 20 °C step. Studies were performed at Synthetic Air flow under humidified (~4 vol%) gas...
-
Low temperature electrical conductivity of the SrTi0.50Fe0.50O3-d pellet
Open Research DataThis dataset contains results of low temperature electrical conductivity measurements of dense SrTi0.50Fe0.50O3-d (STF50) pellet. DC electrical conductivity measurements of STF50 were performed by the Van der Pauw method between 400 °C and room temperature with 20 °C step. Studies were performed at Synthetic Air flow under humidified (~4 vol%) gas...
-
Low temperature electrical conductivity of the SrTi0.10Fe0.90O3-d pellet
Open Research DataThis dataset contains results of low temperature electrical conductivity measurements of dense SrTi0.10Fe0.90O3-d (STF90) pellet. DC electrical conductivity measurements of STF90 were performed by the Van der Pauw method between 400 °C and room temperature with 20 °C step. Studies were performed at Synthetic Air flow under humidified (~4 vol%) gas...
-
Electrical conductivity of the (Ce0.80Gd0.20)O1.90 pellet at different oxygen partial pressures
Open Research DataThis dataset contains results electrical conductivity measurements of dense (Ce0.80Gd0.20)O1.90 (CGO-20) pellet. DC electrical conductivity measurements of CGO-20 were performed by the Van der Pauw method between 900 °C and 450 °C with 50 °C step. Studies were performed at different oxygen partial pressures (100%, 20% and 1%) under humidified (~4...
-
Measurements of radiation emission of a portable power bank with a capacity of 10400 mAh
Open Research DataThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell (Fig. 1). The test setup was configured to measure a portable power...
-
Electrical and noise responses of carbon nanotube networks enhanced by UV light for nitrogen dioxide sensing
Open Research DataNetworks consisting of randomly oriented carbon nanotubes (CNN) were investigated toward nitrogen dioxide detection by means of electrical and low-frequency noise measurements. UV-activation of CNN layers improved gas sensitivity and reduced the limit of detection, especially by employing 275 nm-LED. This data set includes DC resistance measurements...
-
The conducted immunity test of an AC adaptor in accordance with EMC standards
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the ac adaptor PHILIPS DC power supply SBC 6654. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 150 kHz...
-
Simulation of ship turning circle test for ballast and full load conditions
Open Research DataThe data show the results of the turning circle spiral test for the simplified ship model, taking into account two states of loading: ballast and full load. During the circulation test, the manoeuvrability of the vessel is tested.
-
Testing HIADAC high impedance analyzer in Trento University laboratory on Baunier's RC model using 2 wire probe
Open Research DataThe dataset presents impedance spectrum of Baunier's RC model. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 mHz – 100 kHz) was selected in order to test the whole measureement range of the analyzer. In...
-
X-Ray diffraction of the metallic nanostructures
Open Research DataMetallic nanostructures (gold and silver) were manufactured as a thermal annealing of gold or silver thin film. Gold films with thickness of 2.8 nm were deposited on a silicon substrates using a table-top dc magnetron sputtering coater (EM SCD 500, Leica), equipped with quartz microbalance for in-situ thickness measurements. Films were deposited from...
-
SEM images of dewetted gold films
Open Research DataGold nanostructures were prepared on silicon - Si(111) as a substrate. as a result of dewetting process. Thin golds films were deposited using a table-top dc magnetron sputtering coater under pure Ar plasma conditions . The Au target had 99.99% purity, the rate of Au layer deposition was about 0.4 nm·s−1 and the incident power was 32 W. The thickness...
-
Oxidation of silver nanostructures
Open Research DataSilver nanostructures were prepared on Si substrate. Thin Ag films (2 and 6 nm thickness) were deposited using a tabletop dc magnetron sputtering coater (EM SCD 500, Leica) in pure Ar plasma. The Ag target was of 99.99% purity, the rate of layer deposition was about 0.4 nm·s−1 , and the incident power was in the range of 30–40 W. The layer thickness...