Filters
total: 2907
displaying 1000 best results Help
Search results for: WASTWATER TREATMENT PLANT
-
Anaerobic bacteria in wastewater treatment plant
Publication -
Model based evaluation of plant improvement at a large wastewater treatment plant (WWTP)
PublicationIn this work, the effect of the improvement carried out at a large-scale wastewater treatment plant (WWTP) was evaluated, by means of modelling works, with the aim to determine the influence of the modernization over the process performance. After modernization, the energy consumption due to the aeration decreased about a 20% maintaining the effluent quality. In order to double-check the good effluent quality, modelling works were...
-
Microorganisms in the air over wastewater treatment plant.
PublicationCelem pracy było aktywności źródeł emisji mikroorganizmów do powietrza na terenie oczyszczalni ścieków. Stwierdzono iż najwyższe liczebności bakterii występowały w rejonie piaskowników i komór recyrkulacji osadu czynnego. Natomiast liczba bakterii w rejonie komór napowietrzania była zbliżona do tła.
-
Mathematical Modelling in Diagnosis of Wastewater Treatment Plant
PublicationThe paper reports development of mathematical modeling in diagnosis of the WWTP. The algorithm is based on a comparition of data from the mathematical modeling and measurments of real datefrom WWTP, until it will detect any malfunction of the sensors in th case of study.
-
Ciliated protozoa in the impact zone of the Uzhgorod treatment plant
PublicationThis paper presents the results of studies on the Uzh River (Ukraine, Zakarpattia Oblast) near the effluent point of a sewage treatment plant in Uzhgorod. The samples were taken at various sites of the treatment plant along the stages of purification process, as well as in the river, at a number of different points above and below the wastewater discharge. At each of these objects, the temperature...
-
Supervised model predictive control of wastewater treatment plant
PublicationAn optimizing control of a wastewater treatment plant (WWTP), allowing for cost savings over long time period and fulfilling effluent discharge limits at the same time, requires application of advanced control techniques. Model Predictive Control (MPC) is a very suitable control technology for a synthesis of such a truly multivariable controller that can handle constraints and accommodate model-based knowledge combined with hard...
-
Analysis of energy consumption at the Rzeszów Wastewater Treatment Plant
Publication -
Behavior of lipids in biological wastewater treatment plant processes
PublicationLipidy (oleje, smary, tłuszcze oraz długołańcuchowe kwasy tłuszczowe) są istotnym składnikiem ścieków. Ich ilość np. w ściekach komunalnych stanowi około 30-40% ogólnej wartości ChZT. Przemiany lipidów w procesach biologicznego oczyszczania są obiektem wielu badań, mimo to nie są do końca poznane i zrozumiane. W pracy przedstawiono przegląd literatury dotyczący przemian lipidów w trakcie tlenowego i beztlenowego oczyszczania ścieków...
-
Spatial distribution of pharmaceuticals in conventional wastewater treatment plant with Sludge Treatment Reed Beds technology
PublicationPharmaceutical residues are an emerging environmental problem. It is strongly confirmed that pharmaceuticals are present in soils and environmental waters (surface, marine and even groundwater), and that wastewater treatment plant (WWTP) effluents are the main source of pharmaceuticals in the watershed. The aim of this studywas to recognize the spatial distribution and seasonal changes of selected pharmaceuticals in conventional WWTP...
-
Landfill leachate treatment at a pilot plant using hydrophyte systems
PublicationConstructed wetlands can provide an effective and economical solution to landfill leachate treatment. In the article the performance of a CW for leachate treatment, consisting of two horizontal flow constructed wetlands (HF-CW) beds, working at the municipal landfill in Gdansk-Szadolki in the period 2004-2005 is being discussed. The plant has been operating since 2001. Clogging problems and surface flow occurred in the system...
-
Antimicrobial resistance of fecal indicators in muncipal wastewater treatment plant
PublicationAntimicrobial resistance of fecal coliforms (n = 153) and enterococci (n = 199) isolates was investigated in municipal wastewater treatment plant (WWTP) based on activated sludge system. The number of fecal indicators (in influent and effluent as well as in the aeration chamber and in return activated sludge mixture) was determined using selective media. Susceptibility of selected strains was tested against 19 (aminoglycosides,...
-
Environmental risk assessment of Polish wastewater treatment plant activity
PublicationWastewater treatment plants (WWTPs) play an extremely important role in shaping modern society's environmental wellbeing and awareness, however only well operated and supervised systems can be considered as environmentally sustainable. For this reason, an attempt was undertaken to assess the environmental burden posed by WWTPs in major Polish cities by collecting water samples prior to and just after wastewater release points....
-
Antimicrobial resistance of fecal indicators in municipal wastewater treatment plant
Publication -
Odour nuisance assessment of the food industry wastewater treatment plant
Publication -
Application of subsurface vertical flow constructed wetlands to reject water treatment in dairy wastewater treatment plant
PublicationThe paper presents the effects of applying subsurface vertical flow constructed wetlands (SS VF) for the treatment of reject water generated in the process of aerobic sewage sludge stabilization in the biggest dairy wastewater treatment plant (WWTP) in Poland. Two SS VF beds were built: bed (A) with 0.65 m depth and bed (B) with 1.0 m depth, planted with reeds. Beds were fed with reject water with hydraulic load of 0.1 m d-1 in...
-
The role of the sawage treatment plant in the removal of genotoxic compounds from the environment
PublicationOne reason for increased incidence of various types of cancer are environmental pollutants particularly of anthropogenic origin. All human activities may pollute the environment, but some have significant impact, just to mention energy industry, mining, transportation, chemical and petrochemical industries and housing. Environmental pollutants are a large group of compounds in terms of their physicochemical properties, some of...
-
Influence of landfill leachate on municipal wastewater treatment - model plant(WWTP-MP)
PublicationAbstract In the current study, wastewater treatment model plant (WWTP-MP) was used to investigate the possibilities of landfill leachate co-treatment together with municipal wastewater. The WWT-MP, designed as an A2O multiphase system, was fed with the raw municipal wastewater (from the WWTP Gdańsk "Wschód'', Qav.=82x103 m3/d) with increasing, from 1 to 5 % (vol.), quantity of landfill leachate (collected from Gdańsk landfill ''Szadółki")....
-
Diversity of fecal coliforms and their antimicrobial resistance patterns in wastewater treatment model plant.
PublicationThe occurrence of resistance patterns among wastewater fecal coliforms was determined in the study. Susceptibility of the isolates was tested against 19 antimicrobial agents: aminoglycosides, aztreonam, carbapenems, cephalosporines, b-lactam/b-lactamase inhibitors, penicillines, tetracycline, trimethoprim/sulfamethoxazole, and fluoroquinolones. Additionally the removal of resistant isolates was evaluated in the laboratory-scale...
-
Model of aeration system at biological wastewater treatment plant for control design purposes
PublicationThe wastewater treatment plant (WWTP) is a dynamic, very complex system, in which the most important control parameter is the dissolved oxygen (DO) con-centration. The air is supplied to biological WWTP by the aeration system. Aera-tion is an important and expensive activity in WWTP. The aeration of sewage ful-fils a twofold role. Firstly, oxygen is provided as the main component for biolog-ical processes. Secondly, it supports...
-
Atimicrobial Resistance of Enterococcus spp. in Muncipal wasterwater Treatment Plant - Model Study
PublicationIn this study the removal of resistant Enterococcus spp. was evaluated using the laboratory-scale wastewater treatment model plant (M-WWTP), designed as a multiphase (anaerobic, anoxic and aerobic) system (Q = 27 dm3 per day) and continuously supplied with the wastewater obtained from the full-scale WWTP, after grid. The activated sludge from the secondary clarifier was recirculated to the anaerobic chamber (with the ratio equal...
-
Elimination of the chemical and microbiological pollutants in the modernized watewater treatment plant ''Wschód'' in Gdańsk.
PublicationW artykule przedstawiono wyniki 2 letnich, kompleksowych badań efektywności zanieczyszczeń chemicznych, mikrobiologicznych i parazytologicznych w zmodernizowanej oczyszczalni ścieków ''Wschód'' w Gdańsku. Oceniono wpływ funkcjonowania układu generowania lotnych kwasów tłuszczowych na skuteczność usuwania związków biogennych oraz jego oddziaływanie na eliminację zanieczyszczeń biologicznych z oczyszczonych ścieków
-
Application of fuzzy neural network for supporting measurements and control in a wastewater treatment plant
PublicationOczyszczanie ścieków jest jednym z ważniejszych aspektów ochrony środowiska. Nowoczesne systemy kontroli w oczyszczalniach ścieków pozwalają na poprawę jakości procesu oczyszczania redukując jednocześnie koszty. Systemy kontroli i optymalizacji jakie odkilku lat opracowuje się dla oczyszczalni ścieków, bazują zazwyczaj na skomplikowanych modelach matematycznych. Kluczowym problemem w zastosowaniu tych systemów jest duża liczba...
-
Diversity of fecal coliforms and their antimicrobial resistance patterns in wastewater treatment model plant
Publication -
Assessment of the Effects of Wastewater Treatment Plant Modernization by Means of the Field Olfactometry Method
Publication -
The Effects of Wastewater Treatment Plant Failure on the Gulf of Gdansk (Southern Baltic Sea)
Publication -
Respiration rate estimation using non-linear observers in application to wastewater treatment plant
PublicationA problem of respiration rate estimation using two new non-linear observers for a wastewater treatment plant is addressed in this paper. In particular, a non-linear adaptive Luenberger-like observer and a super twisting sliding mode observer have been derived to produce stable and bounded estimates of the respiration rate. During the synthesis of the particular observer, an appropriate mathematical utility model was used. The observability...
-
Task Scheduling – Review of Algorithms and Analysis of Potential Use in a Biological Wastewater Treatment Plant
PublicationThe idea of task scheduling is to increase the efficiency of a system by minimising wasted time, evenly loading machines, or maximising the throughput of machines. Moreover, the use of appropriate scheduling algorithms often leads to a reduction in the energy costs of the process. Task scheduling problems are found in a variety of industrial areas, and their scale changes significantly depending on the problem. This review shows...
-
Modelling of wastewater treatment plant for monitoring and control purposes by state - space wavelet networks
PublicationMost of industrial processes are nonlinear, not stationary, and dynamical with at least few different time scales in their internal dynamics and hardly measured states. A biological wastewater treatment plant falls into this category. The paper considers modelling such processes for monitorning and control purposes by using State - Space Wavelet Neural Networks (SSWN). The modelling method is illustrated based on bioreactors of...
-
Respiration rate estimation for model predictive control of dissolved oxygen in wastewater treatment plant
PublicationRespiration rate is very important parameter for biological processes in wastewater treatment plant (WWTP). The sequential algorithm for estimate the respiration rate is proposed and investigated. The Kalman filter (KF) is used. Simulation tests for the benchmark WWTP are presented.Respiracja jest bardzo ważnym parametrem dla prawidłowego przebiegu procesów biologicznych w oczyszczalni ścieków. W artykule przedstawiono i zbadano...
-
Seasonal changes in the concentrations of airborne bacteria emitted from a large wastewater treatment plant
Publication -
Nitrogen speciation in wastewater treatment plant influents and effluents - the US and Polish case studies
PublicationW pracy przedstawiono wyniki pomiarów różnych frakcji azotu w dopływachi odpływach z trzech konwencjonalnych oczyszczalni ścieków w stanie Illinois (USA) i czterech wysokoefektywnych oczyszczalni w północnej Polsce. Azot organiczny rozpuszczony był dominującą frakcją (56-95%) azotu ogólnego w odpływach z oczyszczalni amerykańskich, podczas gdy w odpływach z oczyszczalni polskich stanowił mniej istotną frakcję (19-62%). W jednym...
-
Nitrogen speciation in wastewater treatment plant influents and effluents - the US and Polish case studies
PublicationW pracy badano stężenia rozpuszczonego węgla organicznego i rozpuszczonego azotu organicznego. W badanych oczyszczalniach amerykańskich ta forma azotu stanowiła 56-95% azotu organicznego, podczas gdy w polskich oczyszczalniach udział ten był znacznie niższy i wynosił 19-62%.
-
Supervisory Control System for Adaptive Phase and Work Cycle Management of Sequencing Wastewater Treatment Plant
PublicationThe paper presents the design of the integrated control system applied to Sequencing Batch Reactor (SBR) in a biological Wastewater Treatment Plant (WWTP) in Swarzewo, which operates under activated sludge technology. Based on the real data records, ASM2d biological processes model and aeration system model, hierarchical control system for dissolved oxygen tracking and cycle management is designed. Internal Model Controller (IMC)...
-
Characteristics of odors emitted from municipal wastewater treatment plant and methods for their identification and deodorization techniques
PublicationOdors emitted from municipal wastewater treatment plants belong to a group of pollutants, which is the main cause of people complaining about atmospheric air quality. The limitation of emissions of unpleasant odors generated by wastewater treatment plants by using appropriate deodorization methods is omitted on numerous occasions. This can have a negative inflence on public trust and the quality of atmospheric air. The article...
-
Chlorinated solvents in a petrochemical wastewater treatment plant: Anassessment of their removal using self-organising maps
PublicationThe self-organising map approach was used to assess the efficiency of chlorinated solvent removal frompetrochemical wastewater in a refinery wastewater treatment plant. Chlorinated solvents and inorganicanions (11 variables) were determined in 72 wastewater samples, collected from three different purificationstreams. The classification of variables identified technical solvents, brine from oil desalting andrunoff sulphates as pollution...
-
Stochastic optimisation algorithm for optimisation of controller parameters for control of dissolved oxygen in wastewater treatment plant
PublicationWastewater treatment plants (WWTPs) are very important facilities for mankind. They enable the removal and neutralisation of man-made pollutants. Therefore, it is important for wastewater treatment plants to operate as efficiently as possible so that the level of pollutants in the treated wastewater meets specific requirements. This paper concerns the design of a hierarchical nonlinear adaptive control system for dissolved oxygen...
-
The effect of anionic surfactant concentration on activated sludge condition and phosphate release in biological treatment plant
PublicationThis paper discusses the influence of a wide range of anionic surfactant concentrations on activated sludge. Linear alkylbenzene sulphonate (LAS) was chosen as an example of a commonly used anionic surfactant. The fate of the surfactant during biological treatment of wastewater was tested. The effect of surfactant on glucose and starch removal was studied.
-
Odour Perception Using a Sniffing Team at a Municipal Solid Waste Treatment Plant: A Case Study
PublicationThe monitoring of odour intensity, generated by a landfill area, is a difficult activity since it is a multi-source problem with discontinuous odour emissions. A modified sniffing team method is described here and applied to determine the main odour sources in a landfill located in Pomerania, Poland. Four consecutive test sessions were performed during the following months: August, December, April, and June. It was found that the...
-
Multiregional PI control strategy for dissolved oxygen and aeration system control at biological wastewater treatment plant
PublicationThe dissolved oxygen is a key parameter for biological processes at wastewater treatment plant. The dissolved oxygen tracking problem is one of the most complex and fundamental issue of biological processes. The paper proposes a new multiregional control strategy for dissolved oxygen tracking problem. The aeration system is included in overall control structure. The control mechanism within the operating point area is based on...
-
Prediction of Wastewater Quality at a Wastewater Treatment Plant Inlet Using a System Based on Machine Learning Methods
PublicationOne of the important factors determining the biochemical processes in bioreactors is the quality of the wastewater inflow to the wastewater treatment plant (WWTP). Information on the quality of wastewater, sufficiently in advance, makes it possible to properly select bioreactor settings to obtain optimal process conditions. This paper presents the use of classification models to predict the variability of wastewater quality at...
-
Aeration Process in Bioreactors as the Main Energy Consumer in a Wastewater Treatment Plant. Review of Solutions and Methods of Process Optimization
PublicationDue to the key role of the biological decomposition process of organic compounds in wastewater treatment, a very important thing is appropriate aeration of activated sludge, because microorganisms have to be supplied with an appropriate amount of oxygen. Aeration is one of the most energy-consuming processes in the conventional activated sludge systems of wastewater treatment technology (may consume from 50% to 90% of electricity...
-
The hybrid estimation algorithm for wastewater treatment plant robust model predictive control purposes at medium time scale
PublicationThe paper proposes an approach to designing the hybrid estimation algorithm/module (HEA) with moving measurements window for Wastewater Treatment Plant (WWTP) Robust Model Predictive Control (RMPC) purposes at medium time scale. The RMPC uses a dedicated grey-box model of biological reactor for the system outputs prediction purposes. The grey-box model parameters are dependant on the plant operating point. Hence, these parameters...
-
Integrated plant-wide modelling for evaluation of the energy balance and greenhouse gas footprint in large wastewater treatment plants
PublicationModern wastewater treatment plants (WWTPs) should maintain a balance between three combined sustainability criteria, including effluent quality, energy performance and greenhouse gas (GHG) emissions. All of these criteria were considered in the integrated plant-wide model developed in this study. The proposed model incorporates new features, including: (i) the addition of associated facilities to the overall energy balance and...
-
Floating treatment wetlands combined with microbial fuel cells (FTW-MFC) batch experiment: plant microscopy observations
Open Research DataThis data collection includes plant root microscope findings. Species chosen for observation: Iris pseudacorus (IP) and Phragmites australis (PA). The anatomical measurements were taken with an optical microscope (Delta Optical Genetic Pro with 3MP camera; Delta Optical, Poland) that had lens magnifications of 4x and 10x and an ocular magnification...
-
Estimation of wastewater treatment plant state for model predictive control of N-P remowal at medium time scale.
PublicationPrzy ograniczonych możliwościach pomiarowych estymaty stanu są potrzebne w sterowaniu optymalizującym, opartym na sterowaniu predykcyjnym, sterującym usuwaniem azotu i fosforu, w biologicznej oczyszczalni ścieków. Optymalizator MPC do implementacji sprzężenia zwrotnego z obiektu potrzebuje tych estymat. Dodatkowo aktualizowane muszą być parametry modelu Gray-Box wykorzystywanego w module MPC. Wtedy estymaty stanu są używane przez...
-
The Problem of Wastewater in Shale Gas Exploitation The Influence of Fracturing Flowback Water on Activated Sludge at a Wastewater Treatment Plant
Publication -
Identification of Selected Antibiotic Resistance Genes in Two Different Wastewater Treatment Plant Systems in Poland: A Preliminary Study
Publication -
Differences between selected volatile aromatic compound concentrations in sludge samples in various steps of wastewater treatment plant operations
PublicationSewage sludge, one of the main wastes generated during wastewater treatment, constitutes an important source of emissions of volatile chemical compounds such as volatile aromatic compounds These substances may undergo various changes as a result of operations and unit processes, which affects their concentrations in sewage sludge. An important factor determining the potential hazardousness of volatile organic compounds is the quality...
-
Evaluation of Health Hazard Due to Emission of Volatile Organic Compounds from Various Processing Units of Wastewater Treatment Plant
PublicationThe paper describes an attempt at health risk assessment and odour concentration determination in the most important units of a wastewater treatment plant. The cancer risk (CR) and hazard index (HI) parameters in selected measurement locations were calculated based on the results of chromatographic analyses (GCxGC-TOF-MS) and the United States Environmental Protection Agency (US EPA) guidelines. No exceedance of the CR and HI acceptable...
-
Comparison of the Measurement Techniques Employed for Evaluation of Ambient Air Odour Quality Influenced by Operation of Industrial Sewage Treatment Plant
PublicationThe paper presents the results of investigation on ambient air quality evaluation with respect to concentration of odorants in a vicinity of a sewage treatment plant of the LOTOS Group S.A. petroleum plant. The investigation was performed during winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type...