displaying 1000 best results Help
Search results for: ion-selective electrodes · multisensor system · potenctiometric measurements · reference electrode
-
Simultaneous determination of Na+, K+, Ca2+, Mg2+ and Cl- in unstimulated and stimulated human saliva using all solid state multisensor platform
PublicationHuman saliva is one of the body fluids which collection method is relatively simple and non-invasive. The article is dedicated to assess concentration (activity) of Na+, K+, Ca2+, Mg2+ and Cl- in fresh, unstimulated or stimulated human saliva samples using single solid contact ion-selective electrodes with conventional reference electrode and self-made multisensor platform (MP) equipped with ion-selective membranes for Na+, K+,...
-
A miniaturized solid-contact potentiometric multisensor platform for determination of ionic profiles in human saliva
PublicationThis paper describes a miniaturized multisensor platform (MP-ISES) consisting of electrodes: a reference one (RE) and ion-selective electrodes (ISEs) for monitoring Na+, K+, Ca2+, Mg2+, Cl−, and SCN− ions and pH in human saliva. Gold electrode surface was modified by deposition of two layers: electrosynthesized PEDOT:PSS forming an intermediate layer, and ion-selective membrane. The developed ISEs were characterized by a wide linear...
-
Potentiometric Solid-Contact Ion-Selective Electrode for Determination of Thiocyanate in Human Saliva
PublicationA new solid-contact potentiometric ion-selective electrode for the determination of SCN− (SCN-ISE) has been described. Synthesized phosphonium derivative of calix[4]arene was used as a charged ionophore. The research included selection of the ion-selective membrane composition, determination of the ISEs metrological parameters and SCN-ISE application for thiocyanate determination in human saliva. Preparation of the ISEs included...
-
Dipodal Tetraamide Derivatives of 1,10-Diaza-18-Crown-6 and Alkylmalonic Acids—Synthesis and Use as Ionophores in Ion Selective Membrane Electrodes
PublicationNovel dipodal derivatives of an 18-membered diaza-crown ether with two diamide chains featuring methylmalonic or butylmalonic acid residues were obtained and tested as ionophores in ion-selective plasticized membrane electrodes. The objective of the study was to identify measurement conditions which ensure the most favorable performance for magnesium ion-selective electrodes. The relationship between the molar lipophilic anion...
-
Kazimierz Darowicki prof. dr hab. inż.
PeopleStudia wyższe ukończyłem w czerwcu 1981 roku po zdaniu egzaminu dyplomowego i obronie pracy magisterskiej. Opiekunem pracy magisterskiej był dr hab. inż. Tadeusz Szauer. W roku 1991, 27 listopada uzyskałem stopień naukowy broniąc pracę doktorską zatytułowaną „Symulacyjna i korelacyjna analiza widm immitancyjnych inhibitowanej reakcji elektrodowej”. Promotorem pracy był prof. dr hab. inż. Józef Kubicki (Wydział Chemiczny...
-
O-substituted tetrahydroxamate derivatives of p-tert-butylcalix[4]arene as receptors for transition and heavy metal cations
PublicationTetrasubstituted O-hydroxamate derivatives of p-tert-butylcalix[4]arene were applied as active materials in ion-selective membrane electrodes and were tested towards Pb-selectivity. The electrodes gave near-Nernstian characteristics for Pb2+ cations. The selectivity coefficients were determined. The influence of plasticizer on the electrode behaviour was studied. The dependence of the chemical structure on selectivity coefficients...
-
Lead(II)-selective ionophores for ion-selective electrodes: A review
PublicationIn potentiometry, high selectivity of the ion-selective membranes must be assured in order to reliably measure various analytes in clinical, industrial and environmental samples. Due to the toxic nature of lead(II) it is important to monitor Pb2+ distribution in natural waters. This may be achieved by implementation of ion-selective electrodes (ISEs) with high selectivity towards lead(II) and low detection limit. A great number...
-
Potentiometric Solid-Contact Multisensor System for Simultaneous Measurement of Several Ions
PublicationThe design and performance of potentiometric multisensor system made in solid-contact technology is described. Both, the measuring electrodes as well as the reference electrode are in a compact cell. The system allows for simultaneous measurement of various ions. The characteristics of the electrodes for Na+, K+ and Ca2+ ions were determined using the designed system and compared with ISEs of the same membrane composition in classical...
-
Wytwarzanie i modyfikacja powierzchni porowatych struktur tytanowych przeznaczonych na implanty
PublicationCelem pracy było wytworzenie stopu Ti-13Nb-13Zr z wykorzystaniem technologii selektywnego topienia laserowego (SLM) oraz jego biofunkcjonalizacja za pomocą utleniania mikrołukowego (MAO), a następnie określenie wpływu parametrów procesowych na właściwości otrzymanych materiałów pod kątem ich zastosowania na implanty. Oceniono wpływ napięcia, natężenia i czasu procesu MAO przeprowadzanego w elektrolicie zawierającym wapń i fosfor...
-
Synthesis and application of tetrazole di and triamide derivatives in ion-selective membrane electrodes
PublicationA number of tetrazole diamides and triamides have been synthesized and applied as ion carries in ion-selective membrane electrodes. Their selectivity and sensitivity were studied towards alkali, alkaline earth, transition and heavy metal cations. it was found that membranes doped with 3 and 2-nitrophenyl octyl ether exhibit an almost theoretial Nernstian response for NH+ over relatively wide concentration range. Elestrodes with...
-
Potentiometric Oxygen Sensor with Solid State Reference Electrode
PublicationThe concentration or the partial pressure of oxygen in an environment can be determined using different measuring principles. For high temperature measurements of oxygen, ceramic-based sensors are the most practical. They are simple in construction, exploration and maintenance. A typical oxygen potentiometric sensor consists of an oxygen ion conducting solid electrolyte and two electrodes deposited...
-
Potentiometric sensor containing set of ion selective electrodes with lipid modified membranes for quality assessment of tested non-alcoholic beverages
PublicationPotentiometric sensors may be a good tool for fast quality control of commercial drinks. In this work, such a sensor, containing a set of ion-selective electrodes with lipid-modified membranes (benzylhexadecyldimethylammonium chloride monohydrate, hexadecylamine, 1-dodecanol, elaidic acid, cholesterol) was used for discrimination and quality control of non-alcoholic beverages, mainly composed of sugar and citric acid. It was found...
-
Properties of Nasicon-based CO2 sensor with Bi8Nb2O17 reference electrode
PublicationGas sensors are useful for the carbon dioxide concentration monitoring in many applications. The major challenge is to develop a potentiometric sensor working without the necessity of a reference gas and without a need of the reference electrode encapsulation. Important issue is a selection of reference electrode material, which should provide stable reference potential. For example as reference electrode material in sensor based...
-
Lead(II)-selective ionophores for ion-selective electrodes: A review
Publication -
Solid-Contact Ion-Selective Electrodes with Highly SelectiveThioamide Derivatives of p-tert-Butylcalix[4]arene for theDetermination of Lead(II) in Environmental Samples
PublicationThioamide derivatives of p-tert-butylcalix[4]arene were used as ionophores in the development of solid-contact ion-selective electrodes based on conducting polymer poly(3,4-ethylenedioxythiophene)/polystyrene sulfonate (PEDOT/PSS) which was synthesized by electrodeposition on the glassy carbon electrodes. The typical ion-selective membranes with optionally two different plasticizers [bis(2-ethylhexyl)sebacate (DOS) and 2-nitrophenyl...
-
Komputerowo wspomagana analiza elastycznych siłowników elektrostatycznych dla potrzeb implementacji w systemach mechatroniki
PublicationPrzeprowadzone badania naukowe rozpoczęto od szczegółowej analizy układu mechatronicznego dłoni robotycznych, powstałych na przestrzeni ostatnich 40 lat, w celu dokładnego rozpoznania ich głównych wymogów konstrukcyjnych i ograniczeń systemowych. Z uwagi na brak dostępnych narzędzi do symulacji omawianych siłowników, w rozprawie opracowano uniwersalne narzędzie – program do analizy numerycznej. U jego podstawy założono wykorzystanie...
-
Equilibration Time of Solid Contact Ion-Selective Electrodes
Publication -
Properties of Nasicon-based CO2 sensors with Bi8Nb2O17 reference electrode
PublicationPotentiometric CO2 sensors based on Nasicon (Na+ conductor, Na3Zr2Si2PO12) electrolyte, Bi8Nb2O17/Pt reference electrode and different sensing electrodes have been prepared. Besides the sensing electrode material, sensors differ from each other in the reference electrode preparation technique. The main aim of this study is to investigate sensor construction and electrode fabrication process influence on sensor properties. The optimal...
-
Solid-contact lead(II) ion-selective electrodes for potentiometric determination of lead(II) in presence of high concentrations of Na(I), Cu(II), Cd(II), Zn(II), Ca(II) and Mg(II)
PublicationLead and its compounds are a serious threat to the environment. Monitoring of this toxic heavy metal is a driving force for the continuous development of novel lead(II) ionophores to be applied in ion-selective electrodes. In this work a highly selective lead(II) ionophore, namely 25,26,27,28-tetrakis(piperidinylthiocarbonylmethylene)-p-tert-butylcalix[4]arene, was used in solid-contact ion-selective electrodes for determination...
-
Uncertainty of Postmortem Time Estimation Based on Potassium Ion Determination in Vitreous Humor Using Potentiometric Ion-Selective Electrode and Microwave-Induced Plasma with Optical Emission Spectrometry Methods
PublicationThere is a need for a reliable and independent evaluation and confirmation of the post-mortem interval (PMI) based on objective factors other than only postmortem changes or temperature measurements. Estimating the PMI by examining the concentration of potassium ions in the vitreous humor (VH) has a tradition in forensic toxicology dating back to the mid-20th century. So far, the methods for determining the presence of potassium...
-
Kinetic Description of the Membrane–Solution Interface for Ion-Selective Electrodes
Publication -
Investigation of poly(3,4-ethylenedioxythiophene) deposition method influence on properties of ion-selective electrodes based on bis(benzo-15-crown-5) derivatives
PublicationGlassy carbon electrodes modified by conductive polymers and membrane with derivatives of bis(benzo-15-crown-5) were tested as solid contact ion selective electrodes for K+ ions concentration determination. PEDOT with PSS, Cl- and ClO4- counter ions was electrochemically deposited onto glassy carbon substrates using four different electrochemical approaches (potentiostatic, galvanostatic, potentiodynamic and potentiostatic pulses)....
-
Poly(hydroxybutyrate-co-hydroxyvalerate) as a biodegradable binder in a negative electrode material for lithium-ion batteries
PublicationIn this work, graphite-based negative electrode for lithium-ion battery consisting a novel and biodegradable binder poly(hydroxybutyrate-co-hydroxyvalerate) (PHBV) is compared with standard graphite electrode with polyvinylidene fluoride (PVDF) as a binder. The rate and cycling performance of lithium ion insertion/extraction of electrodes with PHBV in a half-cell configuration are evaluated. Moreover, on the basis of the electrochemical...
-
Multisensor System for the Protection of Critical Infrastructure of Seaport
PublicationThere are many separated infrastructural objects within a harbor area that may be considered “critical”, such as gas and oil terminals or anchored naval vessels. Those objects require special protection, including security systems capable of monitoring both surface and underwater areas, because an intrusion into the protected area may be attempted using small surface vehicles (boats, kayaks, rafts, floating devices with weapons...
-
Pyrrole azocrown ethers. Synthesis, complexation, selective lead transport and ion-selective membrane electrode studies
PublicationOtrzymano nowe, 21-członowe, lipofilowe etery koronowe z jednostką pirolową i dwoma grupami azowymi jako składowymi makrocyklu. Właściwości kompleksujące tych nowych oraz dwóch wcześniej otrzymanych makrocykli zbadano w acetonitrylu. Ligandy te zostały użyte jako jonofory w badaniach konkurencyjnego transportu równomolowej mieszaniny jonów metali: Co2+, Ni2+, Cu2+, Zn2+, Cd2+, Ag2+, Pb2+ w układzie woda(pH 4.9)/chloroform/woda(pH...
-
High accuracy multisensor hydroacoustic system for models of trawl geometry measurements
PublicationW pracy przedstawiono wieloelementowy hydroakustyczny system do pomiaru modeli włoków. System został zaprojektowany dla Akademii Rolniczej w Szczecinie i umożliwia precyzyjny pomiar geometrii projektowanych tam narzędzi połowowych w tym selektywnych worków dorszowych. Zastosowanie małych hydrofonów o wysokiej częstotliwości pracy oraz cyfrowego przetwarzania sygnałów z analizą korelacyjną umożliwiło uzyskanie bardzo dużej dokładności...
-
Poly(3-octylthiophene) as solid contact for ion-selective electrodes: contradictions and possibilities
Publication -
Anna Lisowska-Oleksiak prof. dr hab.
PeopleAnna Lisowska-Oleksiak, born in 1952, has been working at GUT since 1977. Currently is employed at the Faculty of Chemistry as a full professor. She was employed as a research assistant at the University of St Andrews in the group of C. A. Vincent and P.G. Bruce (1991-1994). She completed a two-month research internship in CEA Grenoble (2011). Anna Lisowska-Oleksiak obtained her MSc in chemistry at Nicolaus Copernicus University...
-
A new phosphonium calix[4]arene for selective anion recognition: synthesis and studies in solution and in ion selective electrodes
PublicationZaprezentowana została synteza i charakteryzacja tetra (trifenylofosfoniowego) p-tert-butylkaliks[4]arenu 2. Oddziaływania z anionami były badane z użyciem (1)H oraz (31)P NMR i spektrofotometrii absorpcyjnej UV. Badania wykazały oddziaływania z anionami: CLO4-, I-, oraz SCN-. Selektywność jonoforu 2 badano również w membranowych elektrodach jonoselektywnych (ISE) PCV/o-NPOE. Elektroda zawierająca związek 2 generuje odpowiedź potencjometryczną...
-
Ion-selective electrodes based on p-tert-butyl-homooxacalixarene di(ethyl) amides
PublicationPochodne dietyloamidowe p-tert-butylodihomooksakaliks[4]arenu (1), p-tert-butyloheksahomotrioksakaliks[3]arenu (2) oraz p-tert-butylokaliks[4]arenu (3) były wykorzystane jako materiał aktywny w membranach elektrod jonoselektywnych w celu sprawdzenia detekcji kationów różnych rodzajów (Na+, K+, Cs+, Mg2+, Ca2+, Mn2+, Cu2+, Zn2+, Cd2+, Pb2+ oraz kation tetrametyloammoniowy). Wyznaczono charakterystyki elektrod oraz współczynniki...
-
Evaluation, Pitfalls and Recommendations for the “Water Layer Test” for Solid Contact Ion‐selective Electrodes
Publication -
Ion-selective electrodes based on p-tert-butyl-homooxacalixarene di(ethyl)amides
Publication -
Three electrode configuration measurements of electrolyte-diffusion barrier-cathode interface
PublicationMeasurements of a system consisting of cathode/doped ceria diffusion barrier/doped zirconia electrolyte were made using two- and three-electrode configuration. Results obtained on a three-electrode measurement configuration were compared with and reflect the results obtained in two-electrode configuration. Three-electrode measurements allowed separating the impact of the symmetrical interface in the investigated system. They also...
-
Comparison of Fluoride Ion-Selective Electrode Based Potentiometric Methods of Fluoride Determination in Human Urine
Publication -
Measurement of sub-nanometer molecular layers with ISFET without a reference electrode dependency
PublicationA new method of detection and measurement with sub-nanometer resolution of layers adsorbed or bonded to the ISFET's gate dielectric was presented. The sensitivity of this method is high enough to detect even partial mono-layer covering. The transconductance measurement of the ISFET provides independence of the output signal from pH changes and the driving electrode electrochemical potential instabilities. The stable reference electrode...
-
Degradation of reference tyres used for CPX measurements
PublicationMeasurements of tyre/road noise using the Close Proximity Method are based on reference tyres that are described in ISO/TS 11819-3. The standard specifies two tyres, namely "P1" and "H1" that should be used during measurements. To be used for measurements each tyre must fulfill certain conditions that are listed in the standard. The conditions are related to the tread pattern depth and rubber hardness. During experiments performed...
-
Composites of tin oxide and different carbonaceous materials as negative electrodes in lithium-ion batteries
PublicationAbstract Tin and tin oxide have been considered as suitable materials with high theoretical capacity for lithium ion batteries. Their low cost, high safety and other technical benefits placed them as promising replacements for graphite negative electrodes. The problem to overcome with tin oxide, as well as with other metallic materials, is high volume changes during alloying/dealloying, subsequent pulverization, delamination from...
-
Tin Oxide Encapsulated into Pyrolyzed Chitosan as a Negative Electrode for Lithium Ion Batteries
PublicationTin oxide is one of the most promising electrode materials as a negative electrode for lithium-ion batteries due to its higher theoretical specific capacity than graphite. However, it suffers lack of stability due to volume changes and low electrical conductivity while cycling. To overcome these issues, a new composite consisting of SnO2 and carbonaceous matrix was fabricated. Naturally abundant and renewable chitosan was chosen...
-
A telemedical and an outpatient thoracic impedance measurements - a validation algorithm of the electrodes placement
PublicationThis paper presents the algorithm for validation of electrodes locations for the thoracic impedance measurements. In particular the presented algorithm was designed to perform the telemetric sleep apnea monitoring. One of the problems, during the clinical tests of a developed device, was to preserve the repeatability of measurements. It strongly depended on the appropriate electrodes placement on the examined person’s thorax. It...
-
Lignin-based carbon fibers for renewable and multifunctional lithium-ion battery electrodes
PublicationLignin-based carbon fibers (LCFs) from the renewable resource softwood kraft lignin were synthesized via oxidative thermostabilization of pure melt-spun lignin and carbonization at different temperatures from 1000°C to 1700°C. The resulting LCFs were characterized by tensile testing, scanning electron microscopy (SEM), X-ray diffraction (XRD) and confocal Raman spectroscopy. The microstructure is mainly amorphous carbon with some...
-
Accuracy of marine gravimetric measurements in terms of geodetic coordinates of land reference benchmark
PublicationThe article presents how the values of (3D) coordinates of land reference points affect the results of gravimetric measurements made from the ship in sea areas. These measurements are the basis for 3D maritime inertial navigation, improving ships' operational safety. The campaign verifying the network absolute point coordinates used as a reference point for relative marine gravity measurements was described. The obtained values...
-
PEDOT(PSS) as Solid Contact for Ion-Selective Electrodes: The Influence of the PEDOT(PSS) Film Thickness on the Equilibration Times
Publication -
Solid-Contact Ion-Selective Electrodes with Highly Selective Thioamide Derivatives of p-tert-Butylcalix[4]arene for the Determination of Lead(II) in Environmental Samples
Publication -
Reference Electrodes with Ionic Liquid Salt Bridge: When Will These Innovative Novel Reference Electrodes Gain Broad Acceptance?
Publication -
Certified Reference Material - as a necessary tool for the quality control and quality assurance of measurements
PublicationReference materials are necessary to control and ensure the quality of the measurements. The demand for analytical information on the composition of different material objects makes it necessary to produce an even wider range of materials.
-
In-situ and ex-situ resistance measurements of polypyrrole film using double-band electrode
PublicationMany in-situ techniques are performed in order to determine the resistance of conducting polymer film. However, the resistance measured in solution can be the combination of polymer resistance and that of other components, such as resistance of supporting electrolyte. Therefore, in this work, the influence of the solution on the resistance of polypyrrole (PPy) film has been studied. PPy film was electrchemically synthesized onto...
-
Advanced Lithium-Ion Battery Model for Power System Performance Analysis
PublicationThe paper describes a novel approach in battery storage system modelling. Different types of lithium-ion batteries exhibit differences in performance due to the battery anode and cathode materials being the determining factors in the storage system performance. Because of this, the influence of model parameters on the model accuracy can be different for different battery types. These models are used in battery management system...
-
Accuracy Analysis of Determination the Vertical Displacements in Unstable Reference System
PublicationMeasurements of horizontal and vertical displacements are carried out mostly based on reference points identified as fixed. In surveying practice there may be some situations in which there is not possible to perform the measurements with reference to stable points or the difficulties in identification of points’ stability may arise. Accuracy analysis based on the covariance matrices have a special role in this process. In presented...
-
Automatic system for optical parameters measurements of biological tissues
PublicationIn this paper a system allowing execution of automatic measurements of optical parameters of scattering materials in an efficient and accurate manner is proposed and described. The system is designed especially for measurements of biological tissues including phantoms, which closely imitate optical characteristics of real tissue. The system has modular construction and is based on the ISEL system, luminance and color meter and...
-
Reference FEM model for SHM system of cable-stayed bridge in Rzeszów
PublicationThe paper presents the references model for structural health monitoring system (SHM) of cable-stayed bridge recently constructed in Rzeszów over Wisłok River. The SHM system is design to provide on-line information on the structure state and facilitate its maintenance procedures. The main feature of the SHM system is permanent observation of the dynamic behavior of the bridge with focus on cable vibrations. The paper discusses...