Filters
total: 1719
-
Catalog
displaying 1000 best results Help
Search results for: acoustic vector sensor
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 50 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 70 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapasitor with the use of ZnO coated microsphere-based fiber-optic sensor - 30 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 60 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 40 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 85 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 55 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 100 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Investigations of pitting corrosion of magnesium by means of DEIS and acoustic emission
Publication -
Acoustic signal processing in passive sonar system with towed array
PublicationW referacie opisano przetwarzanie sygnałów akustycznych w pasywnym systemie hydrolokacyjnym. W pojęciu ''przetwarzanie sygnałów akustycznych'' mieszczą się wszelkie operacje wykonywane na sygnałach analogowych tj. wzmacnianie, filtracja i próbkowanie, jak również operacje na sygnałach cyfrowych uzyskanych w procesie próbkowania. Do operacji cyfrowych wykonywanych w systemie zalicza się synchronizację, konwersję, sortowanie, wytwarzanie...
-
On intermolecular potential determination via equations of state and by acoustic data
Publication...
-
Searching for objects under the sea bed bythe acoustic method
PublicationOpisano metodykę poszukiwania przedmiotów zamulonych w morzu z zastosowaniem metod akustycznych.
-
Advanced acoustic signal analysis used for wheel-flat detection
Publication -
Underwater acoustic communications system with error correction and synchronization coding
PublicationNiezawodna transmisja danych w wielodrogowym i niestacjonarnym płytkim kanale podwodnym wymaga zastosowania efektywnej techniki modulacji oraz equalizacji adaptacyjnej. W zaproponowanym artykule w systemie transmisji danych zastosowano modulację OFDM oraz equalizację adaptacyjną opartą o filtrację Kalmana. Ponadto zaimplementowano dwie techniki kodowania: FEC w celu eliminacji błędów transmisji oraz kodowanie pseudoszumowe, którego...
-
The estimation of norwegian cod size distribution from acoustic data
Publication -
A novel approach to bottom scattering using a narrow acoustic beam.
PublicationPrzedstawiono model opisujący w prosty sposób rozpraszanie sygnału akustycznego na dnie morskim jako filtr liniowy z odpowiedzią impulsową o zmieniającej się w czasie chwilowej dominującej częstotliwości. Przedyskutowano pasujący do tego modelu przypadek zbioru punktowych rozpraszaczy równomiernie rozmieszczonych na powierzchni dna, w tym wpływ takich parametrów jak głębokość oraz odległość pomiędzy rozpraszaczami.
-
Acoustic radiation force and streaming caused by non periodic acousticsource.
PublicationTeoria i obliczenia numeryczne przepływu rotacyjnego (''streamingu'') towarzyszącemu fali akustycznej w przepływach lepkich nieliniowych. Fala wywołująca może być nieokresowa: impulsowa lub paczka falowa itd. Przykład pojedynczego pulsu rozpatrywany. Ilustracje delikatnej struktury czasowej powstania fal rotacyjnych przedstawione na rysunkach.
-
Liquid water. Analytical equation of state and acoustic parameters evaluation.
PublicationRównanie stanu dla ciekłej wody zaproponowane przez Jefferya - Austina zastosowano do obliczeń prędkości dźwięku oraz parametru nieliniowości B/A. Parametry akustyczne są porównywane z danymi doświadczalnymi.
-
Synchronization system for underwater acoustic communications using in shallow waters
PublicationA reliable synchronization system of the transmitted data frame has a significant impact on the efficiency of the underwater communication system. This applies in particular to communication systems dedicated to work in shallow waters, where the phenomenon of multipath permanently occurs. To overcome these difficulties, the concept of a synchronization system consisting of two broadband signals of opposite monotonicity was presented....
-
The possibility of application of the potentiometric sensor with all-solid-state electrodes containing lipid-polymer membranes for classification of tested black leaf teas in terms of their quality
PublicationPotentiometric sensor with all-solid-state electrodes containing lipid-polymer membranes for a set of black leaf teas coming from four countries (China, India, Sri Lanka and Kenia) classification was applied. The tested tea samples were reassigned to quality classes marked with numbers I–V according to the information available. The sensor results of tea samples are presented in the form of radar charts. It was observed that, in...
-
Identification of defected sensors in an array of amperometric gas sensors
PublicationPurpose Amperometric gas sensors are commonly used in air quality monitoring in long-term measurements. Baseline shift of sensor responses and power failure may occur over time, which is an obstacle for reliable operation of the entire system. The purpose of this study is to check the possibility of using PCA method to detect defected samples, identify faulty sensor and correct the responses of the sensor identified as faulty. Design/methodology/approach In...
-
Assessment of Wide-Sense Stationarity of an Underwater Acoustic Channel Based on a Pseudo-Random Binary Sequence Probe Signal
PublicationThe performances of Underwater Acoustic Communication (UAC) systems are strongly related to the specific propagation conditions of the underwater channel. Designing the physical layer of a reliable data transmission system requires a knowledge of channel characteristics in terms of the specific parameters of the stochastic model. The Wide-Sense Stationary Uncorrelated Scattering (WSSUS) assumption simplifies the stochastic description...
-
Prediction of Overall In Vitro Microsomal Stability of Drug Candidates Based on Molecular Modeling and Support Vector Machines. Case Study of Novel Arylpiperazines Derivatives
PublicationOther than efficacy of interaction with the molecular target, metabolic stability is the primary factor responsible for the failure or success of a compound in the drug development pipeline. The ideal drug candidate should be stable enough to reach its therapeutic site of action. Despite many recent excellent achievements in the field of computational methods supporting drug metabolism studies, a well-recognized procedure to model...
-
Sławomir Jerzy Ambroziak dr hab. inż.
PeopleSławomir J. Ambroziak was born in Poland, in 1982. He received the M.Sc., Ph.D. and D.Sc. degrees in radio communication from Gdańsk University of Technology (Gdańsk Tech), Poland, in 2008, 2013, and 2020 respectively. Since 2008 he is with the Department of Radiocommunication Systems and Networks of the Gdańsk Tech: 2008-2013 as Research Assistant, 2013-2020 as Assistant Professor, and since 2020 as Associate Professor. He is...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.4
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.5
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.3
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Tuning of food wastes bioavailability as feedstock for bio-conversion processes by acoustic cavitation and SPC, SPS, or H2O2 as external oxidants
PublicationThe growing amount of food wastes makes them a suitable source for the generation of bioproducts through anaerobic digestion. Appropriate hydrolysis of the feedstock can enhance the efficiency of production of desired products. In this work, acoustic cavitation (AC) was employed as a pretreatment method to enhance hydrolysis stage by the modification of model (potato-based) food waste for increase in soluble chemical oxygen demand...
-
Power quality conditioners with minimum number of current sensor requirement
Publication -
On The Application Of Fiber Optics In The Development Of Sensor Systems Of Intelligent Robots
Publication -
GNSS-based multi-sensor system for structural monitoring applications
Publication -
Fiber-optic temperature sensor using low-coherence interferometry
Publication -
Modular wireless sensor network platform for RF transceiver evaluation
PublicationArtykuł przedstawia modułową technikę projektowania sieci sensorów bezprzewodowych. Uniwersalne połączenia występujące pomiędzy modułami pozwalają na zaprojektowanie nowej wersji sieci w przeciągu kilku dni zamiast tygodni. Na bazie wymienionej metodologii skonstruowane została platforma pozwalająca testować różnego rodzaju układy nadawczo odbiorcze pracujące na częstotliwościach RF.
-
Electrical properties of poros nanocrystalline undoped ceria oxygen sensor
PublicationW pracy zaprezentowano wykonanie czujnika z niedomieszkowanego tlenku ceru o nanometrowych ziarnach krystalicznych. Zastosowana metoda nanoszenia warstw zalicza się do metod niskotemperaturowych. Wytworzone warstwy przebadano za pomocą dyfrakcji rentgenowskiej, mikroskopii elektronowej oraz spektroskopii impedancyjnej. Wykonane czujniki charakteryzują się szybkim czasem odpowiedzi i stabilnym zachowaniem przy zmianach ciśnienia...
-
Influence of aprotic solvent on selectivity of an amperometric sensor with nafion membrane
PublicationW publikacji przedstawiono rezultaty badań dotyczące selektywności amperometrycznego czujnika ditlenku siarki z membraną nafionową wobec tlenku węgla i dwutlenku azotu jako interferentów. Zostały porównane współczynniki selektywności dla czujników wypełnionych roztworami elektrolitów zawierających wodne roztwory kwasu siarkowego i różne ilości rozpuszczalnika aprotycznego - dimetylosulfotlenku.
-
Impedance investigations of amperometric gas sensor containing aprotic solvent
PublicationSkonstruowany został amperometryczny czujnik gazowy w układzie trójelektrodowym ze złotą elektrodą roboczą bezpośrednio napyloną na membranę Nafionową. W publikacji przedstawiono wyniki badań charakterystyk czujnika do oznaczania ditlenku siarki wypełnionego elektrolitem zawierającym różne względne zawartości DMSO/H2O. Wyniki badań impedancyjnych zostały przeanalizowane w oparciu o zaproponowany elektryczny układ zastępczy.
-
Influence of aprotic solvent on a signal of an amperometric sensor with Nafion membrane
PublicationW pracy przedstawiono wyniki badań charakterystyk analitycznych amperometrycznego czujnika ditlenku siarki wyposażonego w mebranę nafionową i wypełnionego roztworami elektrolitów o różnej zawartości dimetylosulfotlenku. Ocenie poddany został wpływ zawartości DMSO w roztworze elektrolitu wewnętrznego czujnika oraz prędkości przepływu gazu na czułość czujnika i czas odpowiedzi na zmiany stężenia ditlenku siarki.
-
The influence of electrocatalytic toxic gas sensor construction on its performance
PublicationW pracy przedstawiono porównanie właściwości elektrokatalitycznych czujników gazów przygotowanych na bazie różnych elektrolitów stałych oraz wykonanych w różnych technologiach.
-
Design Optimization of an Anisotropic Magnetoresistance Sensor for Detection of Magnetic Nanoparticles
Publication -
Fluctuation-enhanced scent sensing using a single gas sensor
PublicationWykrywanie zapachów podczas aromaterapii może być przeprowadzone za pomocą pojedynczego sensora gazów. W pracy rozważono efektywność detekcji zapachów olejków eterycznych za pomocą rezystancji DC oraz zjawisk fluktuacyjnych w tych sensorach, typu TGS2600,TGS2602,TGS823. Badania koncentrowały się na praktycznym zastosowaniu w aromaterapii do określania intensywności emitowanego zapachu. Opisano szczegółowo system do emisji zapachów.
-
Evaluation of physiological and physical activity by means of a wireless multi-sensor
Publicationmonitorowanie osób starszych, upośledzonych ruchowo i/lub rekonwalescentów w warunkach domowych jest dynamicznie rozwijającą się dyscypliną nauki i techniki. szczególnego znaczenia nabierają systemy przeznaczone dla osób starszych żyjących samotnie. w pracy przedstawiono zintegrowany system umożliwiający monitorowanie wybranych parametrów fizjologicznych (ekg, ikg, resp) oraz aktywności fizycznej za pomocą akcelerometru. działanie...
-
Analysis of unsteady flow forces on the thermowell of steam temperature sensor
PublicationIn this paper, 3D numerical analysis of unsteady flow forces acting on the measuring sheath of steam temperature is presented. According to that purpose, the CFD (Computation Fluid Dynamic [1]) approach has been used. The nonstationary of fluid acting on the measuring sheath such as: Strouhal frequency, amplitude of pressure, structure of vortex, peak of pressure, field of pressure, field of velocity etc. are studied analytically...
-
Sensitivity to nitrogen dioxide of electrocatalytic gas sensor based on NASICON
PublicationW pracy przedstawiono wyniki badań czujnika elektrokatalitycznego na bazie NASICONu.
-
Detection of immunological agent by optical fiber sensor: preliminary study
PublicationThe objective of this study is the application of optical methods for detection of immunological agent concentration. As the agent we used the Cyclaid, produced by Apotex Inc. In this article we investigated different Cyclaid concentrations in water. We used a Fabry-Pérot interferometer working in a reflective mode, the measurements were performed with source with central wavelength λ = 1550 nm. The preliminary investigation have...
-
space-vector pulse width modulation for three-level npc converter with the neutral point voltage control
PublicationPrzedstawiono strategię modulacji PWM dla trójpoziomowych falowników NPC z predykcją i kompensacją asymetrii rozkładu napięcia na kondensatorach obwodu pośredniczącego
-
Optimized Space Vector Modulation strategy for five phase voltage source inverter with third harmonic injection
PublicationThis paper presents a simple and an effective SVM algorithm for five-phase Voltage-Source Inverters with the possibility to control independently the voltage vectors for fundamental and auxiliary orthogonal subspaces. The essential benefit is that output voltage is generated using only four active voltage vectors with limited numbers of switching. In the proposed solution, four active vectors are arbitrary chosen, independent of...
-
INSTITUTIONAL VECTOR OF ECONOMIC DEVELOPMENT [ ІНСТИТУЦІОНАЛЬНИЙ ВЕКТОР ЕКОНОМІЧНОГО РОЗВИТКУ ]
Journals -
European Vector of Economic Development [ Європейський вектор економічного розвитку ]
Journals -
Valorization of waste cabbage leaves by postharvest photochemical treatments monitored with a non-destructive fluorescence-based sensor
PublicationThe biosynthesis of polyphenolic compounds in cabbage waste, outer green leaves of white head cabbage (Brassica oleracea L. var. capitata subvar. alba), was stimulated by postharvest irradiation with UVB lamps or sunlight. Both treatments boosted the content of kaempferol and quercetin glycosides, especially in the basal leaf zone, as determined by the HPLC analysis of leaf extracts and by a non-destructive optical sensor. The...
-
Micro-cracking pattern recognition of hybrid CNTs/GNPs cement pastes under three-point bending loading using acoustic emission technique
PublicationThe generation of microcracks has an important influence on the behaviour of concrete structures. In this study, the acoustic emission (AE) technique was used to investigate the fracture phenomena and micro-cracking behavior of hybrid carbon nanotubes (CNTs, the 1-D allotrope of carbon atoms) and graphene nanoplatelets (GNPs, 2D monolayer of sp2-hybridized carbon atoms), cement composites under three-point bending loading. In...