Filters
total: 1249
-
Catalog
displaying 1000 best results Help
Search results for: measurement systems
-
Polyarmonic model of synchronous generator for analysis of autonomous power generation systems
PublicationAbstract: This paper presents the polyharmonic modelling of synchronous generator (SG) in machine variables. The simple geometry and windings physical layout has been used for inductance calculations of a salient-pole SG. The main advantage of this model is the ease of describing an autonomous power generation system (APGS) in terms of its topology and thus providing effective analysis at the static and dynamic states, both for...
-
Portable raman spectrometer for maritime security applications
PublicationThe fast identification of explosives, narcotics and other chemicals carried on board of ships or transported in containers to the harbors is an important problem of maritime security. Raman spectroscopy is widely used for fast identification of various chemicals. Continuous progress in the field of photonics has resulted in commercial availability of low-power compact Raman spectrometers which can be integrated into portable systems....
-
Passive and Active Measurement Conference
Conferences -
The radiated immunity test of an astable multivibrator in the frequency range from 100 MHz to 300 MHz
Open Research DataThe dataset presents a result of measurements that are a part of electromagnetic field immunity tests. The radiated, radio frequency, immunity tests were carried out for a typical astable electronic multivibrator. Tests of immunity of electronic systems to radiated radio frequency (RF) disturbances in the frequency range from 100 MHz to 300 MHz were...
-
Investigation of the road noise source employing an automatic noise monitoring station
PublicationThe paper presents a pilot investigation of noise source models in two selected localizations in the context of future dynamic noise map creation. The experiments were carried out using the automatic noise monitoring station engineered at the Multimedia Systems Departmentof the Gda´nsk University of Technology. The results of the noise measurements employing monitoring stations and its comparison to the reference values are depicted....
-
A nine-input 1.25 mW, 34 ns CMOS analog median filter for image processing in real time
PublicationIn this paper an analog voltage-mode median filter, which operates on a 3 × 3 kernel is presented. The filter is implemented in a 0.35 μm CMOS technology. The proposed solution is based on voltage comparators and a bubble sort configuration. As a result, a fast (34 ns) time response with low power consumption (1.25 mW for 3.3 V) is achieved. The key advantage of the configuration is relatively high accuracy of signal processing,...
-
Acoustic Processor of the Mine Countermeasure Sonar
PublicationThis paper presents the concept of an acoustic processor of the mine countermeasure sonar. Developed at the Department of Marine Electronics Systems, Gdansk University of Technology, the acoustic processor is an element of the MG-89, an underwater acoustic station. The focus of the article is on the modules of the processor. They are responsible for sampling analogue signals and implementing the algorithms controlling the measurement...
-
Devices for the production of reference gas mixtures
PublicationFor many years there has been growing demand for gaseous reference materials, which is connected with development in many fields of science and technology. As a result, new methodological and instrumental solutions appear that can be used for this purpose. Appropriate quality assurance/quality control (QA/QC) must be used to make sure that measurement data are a reliable source of information. Reference materials are a significant...
-
HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS, Bone marrow - Male, 65 - Tissue image [12030630017634401]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS, Bone marrow - Male, 66 - Tissue image [11290630017295901]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS, Bone marrow - Male, 50 - Tissue image [11290630017292711]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS, Bone marrow - Male, 66 - Tissue image [11290630017295301]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS, Bone marrow - Male, 50 - Tissue image [1129063001729491]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS, Bone marrow - Male, 43 - Tissue image [11290630017296031]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS, Bone marrow - Male, 66 - Tissue image [11290630017297311]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS, Bone marrow - Male, 43 - Tissue image [11290630017293951]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS, Bone marrow - Male, 71 - Tissue image [12030630017642391]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS, Bone marrow - Male, 43 - Tissue image [11290630017295281]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS, Bone marrow - Male, 66 - Tissue image [11290630017293701]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS, Bone marrow - Male, 66 - Tissue image [11290630017297081]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS, Bone marrow - Male, 66 - Tissue image [11290630017299111]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS, Bone marrow - Male, 66 - Tissue image [11290630017297341]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS, Bone marrow - Male, 71 - Tissue image [12030630017644751]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS, Bone marrow - Male, 50 - Tissue image [11290630017298531]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS, Bone marrow - Male, 66 - Tissue image [11290630017299721]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS, Bone marrow - Male, 43 - Tissue image [11290630017293531]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS, Bone marrow - Male, 50 - Tissue image [11290630017295461]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS, Bone marrow - Male, 50 - Tissue image [112906300172911]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS, Bone marrow - Male, 65 - Tissue image [12030630017633001]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS, Bone marrow - Male, 43 - Tissue image [11290630017296631]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS, Bone marrow - Male, 50 - Tissue image [11290630017296271]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS, Bone marrow - Male, 43 - Tissue image [11290630017292001]
Open Research DataThis is the histopathological image of HEMATOPOIETIC AND RETICULOENDOTHELIAL SYSTEMS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
System pomiaru pola magnetycznego w procesie demagnetyzacji modeli okrętów =System for magnetic field measurement in degaussing process of ships
PublicationPrzedstawiono wybrane problemy związane z budową stanowiska badawczego oraz badaniami nowych metod demagnetyzacji okrętów prowadzonych na modelach. Przedstawiono zautomatyzowany system pomiarowy do badania pola magnetycznego modelu okrętu. Omówiono strukturę i funkcje układu pomiarowego oraz metodę ograniczania błędów wynikających z przemieszczania czujników pomiarowych względem pola magnetycznego. Podano przykładowe wyniki pomiarów.
-
Improved Procedures for Feature-Based Suppression of Surface Texture High-Frequency Measurement Errors in the Wear Analysis of Cylinder Liner Topographies
Publication -
Power grid frequency measurement in LabVIEW environment using the least mean squares method to signal phase approximation in the presence of noise
Publication -
The influence of the grid density of measurement points on damage detection in an isotropic plate by the use of elastic waves and laser scanning Doppler vibrometry
PublicationDamage detection in structural components, especially in mechanical engineering, is an 2 important element of engineering practice. There are many methods of damage detection, in which 3 changes in various parameters caused by the presence of damage are analysed. Recently, methods 4 based on the analysis of changes in dynamic parameters of structures, i.e. frequencies or mode shapes 5 of natural vibrations, as well as changes in...
-
Equivalence of on-line and reference methods for measurement of pm10 = Równoważność metod pomiarowych on-line i odniesienia stosowanych do oznaczania pm10
PublicationW badaniach nad równoważnością wyników otrzymanych za pomocą pomiaru ciągłego PM10 w stosunku do metody odniesienia stosuje się nienormatywny przewodnik unijny "Demonstration of Equivalence of Ambient Air Monitoring Methods. EC Working Group on Guidance for the Demonstration of Equivalence". W pracy omówiono sposób postępowania wg tego przewodnika. Na podstawie testu terenowego przeprowadzonego na terenie Gdańska w latach 2010-2011...
-
Practical Approach to IP Scheduled Throughput Measurements in Dual Connectivity Systems
PublicationIP scheduled throughput defined according to 3GPP TS 36.314 reflects user throughput regardless of traffic characteristics, and therefore has become one of the most important indicators for monitoring Quality of Service (QoS) of the end user in Evolved Universal Terrestrial Radio Access Network (E-UTRAN). However, networks built on a distributed architecture make the above definition impossible to be applied directly due to the...
-
Improving performance of large thrust bearings through modeling and experimentation
PublicationLarge thrust bearings are highly loaded machine elements and their failures cause serious losses. Start ups and stoppages of the bearing under load are specially critical regimes of operation. Load carrying capacity depends on the profile of the oil gap. In transient states this profile is also changing. In the design of large thrust bearings minimizing thermo-elastic deformations is an important goal, which can be accomplished...
-
Chapter 11 – Application of Chemical Sensors and Sensor Matrixes to Air Quality Evaluation
PublicationIndoor and outdoor air quality is one of the key factors influencing human health. However, air quality evaluation is not easy task. Air is a complex system, which is subjected to changes even within short period of time. Progress in analytical methods and analytical tools provides increasingly more reliable information on the condition and quality of indoor and outdoor air. This progress, however, generates an increase in the...
-
Flap Monitoring Techniques: A Review
PublicationPostoperative tissue flap vitality monitoring enables early detection of clinical complications, allowing for intervention. Timely re-operation can prevent the need for extensive correction procedures, thus reducing healthcare costs and hospitalisation time. Statistics show that monitoring can increase the success rate of flap survival to 95\% or higher. However, despite the significant progress in monitoring techniques, major...
-
Smooth least absolute deviation estimators for outlier-proof identification
PublicationThe paper proposes to identify the parameters of linear dynamic models based on the original implementation of least absolute deviation estimators. It is known that the object estimation procedures synthesized in the sense of the least sum of absolute prediction errors are particularly resistant to occasional outliers and gaps in the analyzed system data series, while the classical least squares procedure unfortunately becomes...
-
THE 3D MODEL OF WATER SUPPLY NETWORK WITH APPLICATION OF THE ELEVATION DATA
Publication3D visualization is a key element of research and analysis and as the source used by experts in various fields e.g.: experts from water and sewage systems. The aim of this study was to visualize in three-dimensional space model of water supply network with relief. The path of technological development of GESUT data (Geodezyjna Ewidencja Sieci Uzbrojenia Terenu – geodetic records of public utilities) for water supply and measurement...
-
Broken rotor symptoms in the sensorless control of induction machine
PublicationThe purpose of this paper is to investigate the need for a universal method for sensorless controlled induction motor drive diagnosis. The increasing number of sensorless control systems in industrial applications require a universal method for the drive diagnosis, which provides reliable diagnostic reasoning independent of control system structure and state variables measurement or estimation method.Simulations and experimental...
-
Noise in biological Raman spectroscopy
PublicationRaman spectroscopy is a widely used method to investigate chemical molecules by analyzing their vibrational transitions. It utilizes inelastic scattering of the laser light irradiating the investigated object. The scattered light requires appropriate filtering to reduce dominant laser light and expose much weaker components having shifted wavelengths of a characteristic spectral pattern. These components are measured by dispersing...
-
Urinary Measurement of Epigenetic DNA Modifications: A Non-Invasive Assessment of the Whole-Body Epigenetic Status in Healthy Subjects and Colorectal Cancer Patients
Publication -
A Measurement Invariance Investigation of the Polish Version of the Dual Filial-Piety Scale (DFPS-PL): Student-Employee and Gender Differences in Filial Beliefs
Publication -
Modeling and Accuracy Assessment of Determining the Coastline Course Using Geodetic, Photogrammetric and Satellite Measurement Methods: Case Study in Gdynia Beach in Poland
PublicationThe coastal environment represents a resource from both a natural and economic point of view, but it is subject to continuous transformations due to climate change, human activities, and natural risks. Remote sensing techniques have enormous potential in monitoring coastal areas. However, one of the main tasks is accurately identifying the boundary between waterbodies such as oceans, seas, lakes or rivers, and the land surface....
-
Gas chromatography-olfactometry (GC-O), electronic noses (e-noses) and electronic tongues (e-tongues) for in vivo food flavour measurement
PublicationThe capter revies two types of artificial olfaction instrumentation, i.e. gas-chromatography-olfactometry (GC-O) and chemical sensor technologies (electronic nose and tongue), combined with multivariate data processing methods as promising approaches for rapid analysis of food. The chapter also includes examples of specific applications for the detection of food flavour and volatile components.
-
Transient States during Short-circuit in a Line Powered by UPS and its Impact on Earth Fault Loop Impedance Measurement and Power Quality
PublicationThe short-circuit in a line powered by Uninterruptible Power Supply (UPS) during different UPS operation modes is presented in the article. The transient state condition related to the short-circuit in a line fed from double conversion On-line UPS is discussed in detail. The results of the measurements of earth fault loop impedance (FLI) in circuits powered by UPS with the instruments of various manufacturers are presented. The...