displaying 1000 best results Help
Search results for: optical inceremental encoder
-
Ewa Wagner-Wysiecka dr hab. inż.
PeopleEwa Wagner-Wysiecka is a graduate of the Faculty of Chemistry at Gdańsk University of Technology (specializing in Chemical Technology, with a focus on Inorganic Technology and a sub-specialty in Technical and Industrial Analytics). She completed her master's thesis, entitled "Identification of Contaminants in Pharmacopoeial Sulfaquinoxaline," under the supervision of Professor Jan F. Biernat. After completing her master's degree...
-
Data obtained by computation for X-ray imaging of grating without magnification using oriented Gaussian beams
Open Research DataThe propagation of X-ray waves through an optical system consisting of grating and X-ray refractive lenses is considered. In this approach, the propagating wave is represented as a superposition of the oriented Gaussian beams. The direction of wave propagation in each Gaussian beam is consistent with the local propagation direction of the X-ray wavefront.
-
Data obtained by computation for X-ray imaging of grating with magnification factor equal 2 using oriented Gaussian beams
Open Research DataThe propagation of X-ray waves through an optical system consisting of grating and X-ray refractive lenses is considered. In this approach, the propagating wave is represented as a superposition of the oriented Gaussian beams. The direction of wave propagation in each Gaussian beam is consistent with the local propagation direction of the X-ray wavefront.
-
Data obtained by computation for X-ray imaging of grating with magnification factor equal 4 using oriented Gaussian beams
Open Research DataThe propagation of X-ray waves through an optical system consisting of grating and X-ray refractive lenses is considered. In this approach, the propagating wave is represented as a superposition of the oriented Gaussian beams. The direction of wave propagation in each Gaussian beam is consistent with the local propagation direction of the X-ray wavefront.
-
Data obtained by computation for X-ray imaging of grating with magnification factor equal 8 using oriented Gaussian beams
Open Research DataThe propagation of X-ray waves through an optical system consisting of grating and X-ray refractive lenses is considered. In this approach, the propagating wave is represented as a superposition of the oriented Gaussian beams. The direction of wave propagation in each Gaussian beam is consistent with the local propagation direction of the X-ray wavefront.
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (2nd serie)
Open Research DataThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (1st serie)
Open Research DataThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Mechanical exfoliation and layer number identification of single crystal monoclinic CrCl3
PublicationAfter the recent finding that CrI3, displays ferromagnetic order down to its monolayer, extensive studies have followed to pursue new two-dimensional (2D) magnetic materials. In this article, we report on the growth of single crystal CrCl3 in the layered monoclinic phase. The system after mechanical exfoliation exhibits stability in ambient air (the degradation occurs on a time scale at least four orders of magnitude longer than...
-
Luminescence of TeO2:Eu thin films
Open Research DataTellurium dioxide doped by europium thin films were deposited by magnetron sputtering method and simultaneously heated at 200 oC. Presence of Eu ions and their valence states was confirmed by X-ray photoemission spectroscopy measurements. The structure of the films as well as the influence of europium dopant on crystalline structure of the films was...
-
Chromogeniczne pochodne azoli jako składniki warstw receptorowych czujników optycznych
PublicationGłównym celem badań prowadzonych w ramach studium doktoranckiego była synteza oraz badanie właściwości chromogenicznych pochodnych azoli, makrocyklicznych i acyklicznych, jako składników warstw receptorowych czujników optycznych. Otrzymane związki zawierają w swojej strukturze resztę heterocykliczną – azol, który może uczestniczyć w tworzeniu kompleksów z jonami metali ciężkich oraz co najmniej jedno ugrupowanie azowe. Obecność...
-
Model of control plane of ASON/GMPLS network
PublicationASON (Automatic Switched Optical Network) is a concept of optical network recommended in G.8080/Y.1304 by ITU-T. Control Plane of this network could be based on GMPLS (Generalized Multi-Protocol Label Switching) protocols. This solution, an ASON control plane built on GMPLS protocols is named ASON/GMPLS. In the paper, we decompose the control plane problem and show the main concepts of ASON network. We propose a hierarchical architecture...
-
Fiber optic displacement sensor with signal analysis in spectral domain
PublicationIn this paper, a study of a low-coherence fiber optic displacement sensor is presented. The sensor consisted of a broadband source whose central wavelength was either at 1310 nm or 1550 nm, a sensing Fabry-Pérot interferometer operating in reflective mode and an optical spectrum analyzer acting as the detection setup. All these components were connected by a single-mode fiber coupler. Metrological parameters of the sensor were...
-
Response of a fiber-optic Fabry-Pérot interferometer to refractive index and absorption changes – modelling and experiments
PublicationThis paper describes how the refractive index and the absorption of investigated substances change the spectrum of the optical radiation at the output of the fiber-optic Fabry-Pérot interferometer. The modeling of the operation of the interferometer takes into account not only the spectra of the refractive index and the absorption of the medium that is inside the cavity, but also spectra of the refractive indices of the core and...
-
Low-coherence sensors with nanolayers for biomedical sensing
PublicationIn this paper, we describe the fiber optic low-coherence sensors using thin film. We investigated their metrological parameters. Presented sensors were made with the use of standard telecommunication single mode optical fiber (SMF28). Different materials were applied to obtain thick layers, such as boron doped diamond, silver and gold. The thickness of layers used in the experiments ranged from 100 nm to 300 nm. Measurements were...
-
Influence of pulse waves on the transmission of near-infrared radiation in outer-head tissue layers.
PublicationIn this study, we investigate the effect of pulse waves on the transmission of near-infrared radiation in the outer tissue layers of the human head. This effect is important in using optical radiation to monitor brain conditions based on measuring the transmission changes in the near-infrared radiation between the source and the detector, placed on the surface of the scalp. This is because the signal related to the changes in the...
-
Recent and Emerging Applications of Graphene-based metamaterials in Electromagnetics
PublicationSurface Plasmon Polaritons (SPPs) operating in mid-infrared up to terahertz (THz) frequencies have been traditionally manufactured on expensive metals such as gold, silver, etc. However, such metals have poor surface confinement that limits the optical applications of SPPs. The invention of graphene is a breakthrough in plasmon-based devices in terms of design, fabrication and applications, thanks to its plasmonic wave distribution,...
-
Polarimetric studies of L-arginine-doped potassium dihydrogen phosphate single crystals
PublicationConoscopic interference patterns, channelled spectra and polarimetric techniques have been used for the characterization of pure and doped (with L-arginine amino acid) potassium dihydrogen phosphate (KDP) single crystals. Experimental polarimetric data have been obtained for the frequently used wavelength of 633 nm and for two close wavelengths of 532 and 543 nm in a high-accuracy dual-wavelength polarimeter. The measurement of...
-
Luminance Distribution Measurements in CAVE-Type Virtual Reality Systems
PublicationIn this article, the immerse 3D visualization lab just opened at the Gdańsk University of Technology is presented. The effect of user “immersion,” it such virtual reality systems, is largely dependent on the optical properties of projected images. Luminance distribution of screens was measured and the luminance uniformity was determined and discussed.
-
Influence of LCVD technologicalparameters on propertiesof polyazomethine thin films
PublicationPurpose: The aim of this paper is to show influence of technological parameters (temperature and gas streamintensity) of low-temperature chemical vapour deposition (LCVD) on optical properties and morphology ofpolyazomethine thin films.Design/methodology/approach: Thin layers of poly (1,4-phenylene-methylenenitrilo-1,4-phenylenenitrilo-methylene) (PPI) were prepared by low temperature LCVD method with use of argon as a transport...
-
Cyfrowy akcelerator wybranych modułów standardu kompresji wideo H.264
PublicationW komunikacie przedstawiono konfigurowalny cyfrowy akcelerator estymacji ruchu (motion estimation) przeznaczony dla enkodera wideo standardu H.264. Akcelerator został wstępnie zaimplementowany w układzie FPGA VIRTEX6-VLX365T, a następnie w układzie ASIC w technologii UMC 90 nm. Obie implementacje zostały zweryfikowane pozytywnie, a szczegółowe wyniki symulacji i pomiarów akceleratora ASIC zostały porównane z innymi dostępnymi w...
-
Spectroscopic and wireless sensor of hematocrit level
PublicationAn optical method for hematocrit measurement has been presented. the sensor, designed and developed by authors, consists of spectroscopic set-up controlled by a microcontroller. measurement results are sent via wireless module. experiment has confirmed the ability of the sensor to determine the hematocrit with appropriate measurementaccuracy.
-
Efficiency limit of excitonic photovoltaic cells under phosphor-based white LED illumination
PublicationThe limit of energy conversion of excitonic photovoltaic cells working under white light illumination generated by phosphor-based LED is analysed using the modified Giebink approach. Particularly, the impact of the optical energy gap and energy loss associated with the excitons dissociation at the heterojunction interface on power conversion efficiency of the device are discussed. From the results of our study it follows that the...
-
Detection of Face Position and Orientation Using Depth Data
PublicationIn this paper an original approach is presented for real-time detection of user's face position and orientation based only on depth channel from a Microsoft Kinect sensor which can be used in facial analysis on scenes with poor lighting conditions where traditional algorithms based on optical channel may have failed. Thus the proposed approach can support, or even replace, algorithms based on optical channel or based on skeleton...
-
Detection of gaseous compounds with different techniques
PublicationSensing technology has been developed for detection of gases in some environmental, industrial, medical, and scientific applications. The main tasks of these works is to enhance performance of gas sensors taking into account their different applicability and scenarios of operation. This paper presents the descriptions, comparison and recent progress in some existing gas sensing technologies. Detailed introduction to optical sensing...
-
Fractal dimension for bending–torsion fatigue fracture characterisation
PublicationFracture surfaces after biaxial fatigue tests were compared using fractal dimension for three types of metallic materials in smooth and notched specimens made of S355J2 and 10HNAP steels and 2017-T4 aluminium alloy, considering both proportional and nonproportional cyclic loading. High-resolution optical 3D measurement studies were performed on the entire fracture surface. A direct correlation between fractal dimension and fatigue...
-
Runner bean (Phaseolus coccineus) histological cross section observations of stems, leaves, and roots using light microscope
Open Research DataThis data set contains images of root crown, root, stem, and leaf cross-sections of runner bean (Phaseolus coccineus). Runner bean seedlings (3-5 cm) were planted on soil amended with poultry (chicken) manure biochars pyrolized at various temperatures (400, 500, and 600 C degrees). Three different poultry manure biochar materials (450, 500, and 600°C)...
-
The morphology of V2O5 nanostructures deposited on quartz glass
Open Research DataThe DataSet contains the confocal microscope images of morphology evolution of vanadium pentaoxide nanostructures on quartz glass obtained by annealing as-prepared films at 500C and 600C under synthetic air.
-
Ryszard Katulski prof. dr hab. inż.
People -
Stark effect of atomic helium singlet lines
PublicationWe present experimental and theoretical investigations of the He spectral series 2S1−nQ1 (n=3÷9, Q=S,P,D,…,n−1) and 2P1−nQ1 (n=3÷9, Q=S,P,D,…,n−1) in electric fields up to 1635 kV/cm. Apart from the allowed transitions with |ΔL|=1, the transitions with |ΔL|=0,2,3,…-without field strictly forbidden-were observed. Several He patterns become similar to hydrogen patterns, which means they are nearly symmetric and show in higher fields...
-
Isotope shifts of multipole lines of Pb I and Pb II
PublicationStudies of isotope shifts of three multipole lines between levels of the ground configuration 6s26p2 of Pb I, i.e.: 461.9 nm(1S0→3P1), 531.5 nm(1S0→3P2) and 733.2 nm(1D2→3P1), as well as 710.2 nm line (6s26p2P3∕2→6s26p2P1∕2) of Pb II are presented. We determined the isotope shifts between four stable isotopes: 204, 206, 207, 208. By the use of King plot analysis we were able to separate the mass and the field shifts. We found that...
-
Studying of polyoxadiazole with Si atom in the backbone
PublicationPurpose: The aim of this paper is to show properties of spin-coated thin films of new polymer having siliconatom in the backbone. This amorphous polymer has appeared to be applied as active films in organic devices (asOLED).Design/methodology/approach: Thin films of 4-(diphenyl(4-(4-(5-(p-tolyoxy)phenyl)-1,3,4-oxadiazol-2-yl)phenyloamino)methyl)-phenyl)silyl)-1-methylbenzamide (Oxad–Si-B) were obtained by spin-coating method.The...
-
Nd3+ doped titanate-germanate glasses for near-IR laser applications
Publication -
Energy conversion in 7-(Diethylamino)coumarin doped PMMA fluorescent fibre
Publication -
Near-IR and mid-IR luminescence and energy transfer in fluoroindate glasses co-doped with Er3+/Tm3+
Publication -
Up-conversion luminescence of Tb^3+ ions in germanate glasses under diode-laser excitation of Yb^3+
Publication -
Capillary waveguide biosensor
Publication -
An optimization model for robust FSO network dimensioning
Publication -
Information-driven network resilience: Research challenges and perspectives
PublicationInternet designed over 40 years ago was originally focused on host-to-host message delivery in a best-effort manner. However, introduction of new applications over the years have brought about new requirements related with throughput, scalability, mobility, security, connectivity, and availability among others. Additionally, convergence of telecommunications, media, and information technology was responsible for transformation...
-
Shrinking-shifting and amplifying-shifting device using transformation optics
PublicationBased on transformation optics (TO), this paper uses geometric divisions and linear coordinate transformations to design “shrinking-shifting—and reshaping”, and “amplifying-shifting—and reshaping” devices. The proposed devices can reshape the sizes and locations of the wrapped-objects inside the core-region. The shrinking-shifting device shrinks the larger object into a smaller one and shifts it to different location, whereas the...
-
Optimizing FSO networks resilient to adverse weather conditions by means of enhanced uncertainty sets
PublicationThis work deals with dimensioning of wireless mesh networks (WMN) composed of FSO (free space optics) links. Although FSO links realize broadband transmission at low cost, their drawback is sensitivity to adverse weather conditions causing transmission degradation on multiple links. Hence, designing such FSO networks requires an optimization model to find the cheapest configuration of link capacities that will be able to carry...
-
Concentration‐Induced Hetero‐Valent Partial‐Inverse Occupation of Infrared Phosphor
PublicationInfrared luminescent materials have evoked much attention from chemists and material scientists. Although substantial progress is made in materials design, the luminescent mechanism remains ambiguous in the complex structures, presenting major barriers to developing novel infrared luminescent materials. Herein, this study aims to deliberate a complete discussion on infrared phosphors with concentration-induced hetero-valent partial-inverse...
-
Non-invasive investigation of a submerged medieval harbour, a case study from Puck Lagoon
PublicationThis study presents an innovative approach to underwater archaeological prospection using non-invasive methods of seabed exploration. The research focuses on the Puck medieval harbour, a cultural heritage site, and utilises acoustic and optical underwater remote-sensing technology. The primary objectives include optimising the use of Airborne Laser Bathymetry in underwater archaeology, enhancing the filtration process for mapping...
-
Influence of reactive oxygen species during deposition of iron oxide films by high power impulse magnetron sputtering.
PublicationIron oxide films were deposited using high power impulse magnetron sputtering (HiPIMS) of an iron cathode in an argon/oxygen gas mixture at different gas pressures (0.5~Pa, 1.5~Pa, and 5.0~Pa). The HiPIMS system was operated at a repetition frequency $f = 100$~Hz with a duty cycle of 1~\%. A main goal is a comparison of film growth during conventional and electron cyclotron wave resonance-assisted HiPIMS. The deposition plasma...
-
Absorption spectroscopy setup for determination of whole human blood and blood–derived materials spectral characteristics
PublicationA dedicated absorption spectroscopy system was set up using tungsten-halogen broadband source, optical fibers, sample holder, and a commercial spectrometer with CCD array. Analysis of noise present in the setup was carried out. Data processing was applied to the absorption spectra to reduce spectral noise, and improve the quality of the spectra and to remove the baseline level. The absorption spectra were measured for whole blood...
-
Optoelectronic device for hematocrit measurements
PublicationAn optoelectronic system for measurements of hematocrit level (HCT) in the whole human blood is presented. Proposed system integrates a dedicated optoelectronic sensor, a microcontroller and a small LCD display in a low cost, battery-powered, handheld device. Chosen method for determining blood hematocrit level is based on optical properties of whole blood in visible and NIR wavelength range. Measurements with the use of proposed...
-
Review of the Usefulness of Various Rotational Seismometers with Laboratory Results of Fibre-Optic Ones Tested for Engineering Applications
PublicationStarting with descriptions of rotational seismology, areas of interest and historical field measurements, the fundamental requirements for rotational seismometers for seismological and engineering application are formulated. On the above basis, a review of all existing rotational seismometers is presented with a description of the principles of their operation as well as possibilities to fulfill formulated requirements. This review...
-
A new method of presosns identification based on comparative analysis of 3D face models
PublicationThe article presents the use of modern close range photogrammetry for possessing highly accurate 3D models of the human face (including the ears). Modern methods used to obtain precise data describing the construction of a human face, and even the whole human body, should allow to get finished measurement material in a very short time. Those features belong to the optical scanning technology. Comparative analysis of models of the...
-
In-situ monitoring of electropolymerization processes at boron-doped diamond electrodes by Mach-Zehnder interferometer
PublicationIn this work, the Mach-Zehnder interferometer was designed to monitor the electrochemical processes conducted at boron-doped diamond electrode surface. The diamond electrodes were synthesized via Microwave Plasma-Assisted Chemical Vapor Deposition on optical grade quartz glass. The achieved transmittance in working are of diamond electrodes reached 55 %. A cage system-based Mach-Zehnder interferometer was used which allowed the...
-
Fiber-optic sensors based on microspheres with nanocoatings (Zastosowanie mikrosfer optycznych z cienkowarstwowymi pokryciami w czujnikach światłowodowych)
PublicationTemperature is one of the most important physical quantities. Temperature measurements are used in every field of life, especially electronics, electrical engineering, energy-related fields, including energy source and storage devices. The goal of this dissertation is to design and optimize the microsphere-based fiber-optic sensors construction for measurement of the sensor surrounding medium temperature, including selection of...
-
Gas Composition Influence on the Properties of Boron-Doped Diamond Films Deposited on the Fused Silica
PublicationThe main subject of this study are molecular structures and optical properties of boron-doped diamond films with [B]/[C] ppm ratio between 1000 and 10 000, fabricated in two molar ratios of CH 4 -H 2 mixture (1 % and 4 %). Boron-doped diamond (BDD) film on the fused silica was presented as a conductive coating for optical and electronic purposes. The scanning electron microscopy images showed homogenous and polycrystalline surface...