Filters
total: 14114
-
Catalog
- Publications 10651 available results
- Journals 87 available results
- Conferences 15 available results
- Publishing Houses 1 available results
- People 121 available results
- Projects 1 available results
- Research Equipment 1 available results
- e-Learning Courses 92 available results
- Events 8 available results
- Open Research Data 3137 available results
displaying 1000 best results Help
Search results for: BLOOD PRESSURE, PULSE TRANSIT TIME, NONINVASIVE MEASUREMENTS, SAMPLING FREQUENCY, LOW PASS FILTER
-
A Trisection Filter Design With Negative Slope of Frequency-Dependent Crosscoupling Implemented in Substrate Integrated Waveguide (SIW)
PublicationThis letter reports on a novel realization of a microwave bandpass filter in a triplet configuration with a frequency-dependent crosscoupling implemented in substrate integrated waveguide (SIW). The design involves implementing dispersive coupling with a negative slope, a feature that allows the capabilities of the classic triplet topology to be extended. In this particular case, the implementation of two transmission zeros on...
-
Low frequency nois of supecapacitor
Open Research DataDataset contains results of low frequency noise observation during discharge of commercially available supercapacitor, type DRL 2.7V 10F, with a nominal capacitance 10 F and a nominal voltage 2.7 V. Supercapacitor was charged to various voltages and discharged through a resistor. In the experiment the 50 Ohm and 200 Ohm resistors were used. The supercapacitor...
-
Highly-Compact Dual-Band Bandpass Waveguide Filter Based on Cross-Shaped Frequency-Dependent Coupling
PublicationThis work reports the design of an original class of highly-compact dual-band bandpass filter based on dual-mode waveguide resonators inter-coupled through a novel type of frequency-dependent coupling (FDC). The devised FDC consists of a cross-shaped metallic structure placed in the broad wall of a rectangular waveguide. This FDC produces two additional poles and three extra transmission zeros (TZs). Specifically, each pole is...
-
Broad Stopband, Low-Loss, and Ultra-Compact Dual-Mode Bandpass Filter Based on HMSIRC
PublicationIn this investigation, an ultra-compact dual-mode bandpass filter (BPF) with a wide stopband re-sponse is realized by using a half-mode substrate-integrated rectangular cavity (HMSIRC). The HMSIRC resonator is designed with a cavity that is rectangular in shape and has metallic vias along three of the sides. The fourth side is open-ended and contains microstrip feed lines. For the purpose of constructing a magnetic wall, a rectangular...
-
A review of design approaches for the implementation of low-frequency noise measurement systems
PublicationElectronic noise has its roots in the fundamental physical interactions between matter and charged particles, carrying information about the phenomena that occur at the microscopic level. Therefore, Low-Frequency Noise Measurements (LFNM) are a well-established technique for the characterization of electron devices and materials and, compared to other techniques, they offer the advantage of being non-destructive and of providing...
-
Uniform sampling in constrained domains for low-cost surrogate modeling of antenna input characteristics
PublicationIn this letter, a design of experiments technique that permits uniform sampling in constrained domains is proposed. The discussed method is applied to generate training data for construction of fast replacement models (surrogates) of antenna input characteristics. The modeling process is design-oriented with the surrogate domain spanned by a set of reference designs optimized with respect to the performance figures and/or operating...
-
Inline Microstrip Bandpass Filter With Two Transmission Zeros and Increased Order Using Spurious Resonance of Frequency-Dependent Inverter
PublicationA design method for a class of fourth-order inline microstrip bandpass filter with two transmission zeros and 20% fractional bandwidth is presented. The filter consists of two quarter-wavelength transmission-line resonators coupled by a frequency-dependent inverter. The inverter is composed of two open-ended stubs that are connected by an interdigital capacitor and introduces two poles and two transmission zeros in the filter response....
-
Twenty‐four‐hour and conventional blood pressure components and risk of preterm delivery or neonatal complications in gestational hypertension
Publication -
High mortality explained by mildly elevated blood pressure in Scandinavian adolescent conscripts – A plea for early drug treatment?
Publication -
Urgent need to address quality control issues of out‐of‐office blood pressure measurement and patient risk assessment
Publication -
A fast time-frequency multi-window analysis using a tuning directional kernel
PublicationIn this paper, a novel approach for time-frequency analysis and detection, based on the chirplet transform and dedicated to non-stationary as well as multi-component signals, is presented. Its main purpose is the estimation of spectral energy, instantaneous frequency (IF), spectral delay (SD), and chirp rate (CR) with a high time-frequency resolution (separation ability) achieved by adaptive fitting of the transform kernel. We...
-
Time-frequency analysis in optical coherence tomography for technical objects examination
PublicationOptical coherence tomography (OCT) is one of the most advanced optical measurement techniques for complex structure visualization. The advantages of OCT have been used for surface and subsurface defect detection in composite materials, polymers, ceramics, non-metallic protective coatings, and many more. Our research activity has been focused on timefrequency spectroscopic analysis in OCT. It is based on time resolved spectral analysis...
-
Device characteristics extraction by low frequency noise measurements; Someresults on the state-of-the-art MOSFET´s
PublicationPrzedstawiono wyniki pomiarów i analizy szumów tranzystorów MOSFET z izolatorem bramki wykonanym z SiO2 i HfO2. Wyniki pomiarów wykorzystano do oszacowania gęstości aktywnych stanów na powierzchni użytego tlenku i porównano z wynikami otrzymanymi metodą charge-pumping.
-
Inline Waveguide Filter With Compact Frequency-Dependent Coupling Producing Two Additional Poles and Three Transmission Zeros
PublicationThis work reports a compact frequency-dependent coupling (FDC) structure introduced in a rectangular waveguide, which allows to generate two additional in-band transmission poles and three transmission zeros (TZs). This serves to increase the order/selectivity of the waveguide bandpass filter in a compact inline topology, thus without the need for any additional space/volume or cross coupling. The proposed FDC consists of a partial-height...
-
Multi-pulse VSC arrangements with coupled reactors
PublicationThis paper presents a novel approach to the multipulse VSC (Voltage Source Converter) arrangements based on several conventional inverter modules connected in parallel by using coupled reactors. This solution reduces the THD of the output voltage, despite the low switching frequency of transistors. The advantage of the proposed solution is also a relatively small rated power of the reactors. Proposed new arrangements for different...
-
Shipping Low Frequency Noise and Its Propagation in Shallow Water
PublicationOne of the most significant factor influencing acoustical climate of the sea is underwater noise generated by moving ships. If the considered sea area has features of the shallow water, namely the wave frequency fulfils relation f < 10c/h, where c denotes phase speed of sound, and h is depths of the sea, then in certain distance from the wave source specific image of sound pressure distribution in the mean of wave modes appears....
-
Implementation of Extended Kalman Filter with Optimized Execution Time for Sensorless Control of a PMSM Using ARM Cortex-M3 Microcontroller
PublicationThis paper addresses the implementation and optimization of an Extended Kalman Filter (EKF) for the Permanent Magnet Synchronous Motor (PMSM) sensorless control using an ARM Cortex-M3 microcontroller. A various optimization levels based on arithmetic calculation reduction was implemented in ARM Cortex-M3 microcontroller. The execution time of EKF estimator was reduced from 260.4 μs to 37.7 μs without loss of accuracy. To further...
-
Low-Voltage Low-Power Filters with Independent ω0 and Q Tuning for Electronic Cochlea Applications
PublicationAn acoustic second-order low-pass filter is proposed for filter banks emulating the operation of a human cochlea. By using a special filter structure and an innovative quality (Q)-factor tuning technique, an independent change of the cutoff frequency (ω0) and the Q-factor with unchanged gain at low frequencies is achieved in this filter. The techniques applied result in a simple filter design with low Q-factor sensitivity to component...
-
Low frequency nois of supecapacitor
Open Research DataDataset contains noise measurement results on prototype electrochemical double layer capacitor. The measurement procedure is described in https://dx.doi.org/10.1515/mms-2017-0059.
-
Masked hypertension in type 2 diabetes: never take normotension for granted and always assess out-of-office blood pressure
Publication -
The J-curve phenomenon revisited again: SPRINT outcomes favor target systolic blood pressure below 120 mmHg
Publication -
From the multiple frequency tracker to the multiple frequency smoother
PublicationThe problem of extraction/elimination of nonstationary sinusoidalsignals from noisy measurements is considered. This problem is usually solved using adaptive notch filtering (ANF)algorithms. It is shown that the accuracy of frequency estimates can be significantly increased if the results obtained from ANF are backward-time filtered by an appropriately designed lowpass filter. The resulting adaptive notch smoothing (ANS)algorithm...
-
Which Target Blood Pressure in Year 2018? Evidence from Recent Clinical Trials
Publication -
Coupling between Blood Pressure and Subarachnoid Space Width Oscillations during Slow Breathing
PublicationThe precise mechanisms connecting the cardiovascular system and the cerebrospinal fluid (CSF) are not well understood in detail. This paper investigates the couplings between the cardiac and respiratory components, as extracted from blood pressure (BP) signals and oscillations of the subarachnoid space width (SAS), collected during slow ventilation and ventilation against inspiration resistance. The experiment was performed on...
-
Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
PublicationIn this paper, a low-coherence Fabry-Perot sensor with a spectrally measured signal processing response to the refractive index of liquids is presented. Optical fiber sensors are potentially capable of continuous measuring hematocrit levels in blood. Low-coherence Fabry-Perot interferometric sensors offer a robust solution, where information about the measurand is encoded in the full spectrum of light reflected from the sensing...
-
Blood pressure in acute ischemic stroke
Publication -
Rating mathematical models for first-pass of tracer in pCT lung studies
PublicationThis paper presents a comparison of model based on the Gauss function and the most commonly used Gamma-variate model in perfusion computed tomography (pCT) lung studies. It also verifies whether used model affects value of blood volume parameter. Three mean concentration-time curves were created from actual pCT measurements: arterial input function, blood vessels in lungs and lung parenchyma. On the basis of these mean curves we...
-
Non-invasive hemodynamic monitoring as a guide to drug treatment of uncontrolled hypertensive patients: effects on home blood pressure in the BEAUTY study
Publication -
A robust 18-pulse diode rectifier with coupled reactors
PublicationThe article presents the principle of operation and selected results of simulation and laboratory tests of the 18-pulse rectifier system with coupled reactors and small series active power filter. The presented system makes it possible to reduce, especially in distribution supply networks, undesired higher current harmonics. The 18-pulse nature of operation of the rectifier is reached using a set of coupled three-phase network...
-
Sensitivity performance of all pole canonical low pass GmC filters.
PublicationW pracy badano własności częstotliwościowe kanonicznych filtrów dolnoprzepustowych GmC bez zer transmisyjnych. Przedstawiono ogólną strukturę kanonicznego filtru dolnoprzepustowego i jej opis macierzowy. Wyprowadzono ogólne wzory określające funkcje wrażliwościowe filtru. Dokonano porównania struktur do 10-go rzędu włącznie dla aproksymacji Butterwortha, Czebyshewa i Bessela.
-
Low-Cost Data-Driven Surrogate Modeling of Antenna Structures by Constrained Sampling
PublicationFull-wave electromagnetic (EM) analysis has become one of the major design tools for contemporary antenna structures. Although reliable, it is computationally expensive which makes automated simulation-driven antenna design (e.g., parametric optimization) difficult. This difficulty can be alleviated by utilization of fast and accurate replacement models (surrogates). Unfortunately, conventional data-driven modeling of antennas...
-
TIME- AND FREQUENCY-DOMAIN QUASI-2D SMALL-SIGNAL MOSFET MODELS
PublicationA novel approach to small-signal MOSFET modeling is presented in this book. As a result, time- and frequency-domain physics-based quasi-2D NQS four-terminal small-signal MOSFET models are proposed. The time-domain model provides the background to a novel DIBL-included quasi‑2D NQS four-terminal frequency-domain small-signal MOSFET model. Parameters and electrical quantities of the frequency-domain model are described by explicit...
-
Determination of time delay between ventricles contraction using impedance measurements
PublicationThe paper presents a novel approach to assessment of ventricular dyssynchrony basing on multichannel electrical impedance measurements. Using a proper placement of electrodes, the sensitivity approach allows estimating time difference between chambers contraction from over determined nonlinear system of equations. The theoretical considerations which include Finite Element Method simulations were verified using measurements on...
-
A novel method of local chirp-rate estimation of LFM chirp signals in the time-frequency domain
PublicationIn the paper, novel dynamic representations of a complex signal in the time-frequency domain are introduced. The proposed approach is based on using the gradient of the short-time Fourier transform complex phase. A channelized instantaneous complex frequency (CICF) and a complex local group delay (CLGD) are included in the presented signal representations. An application of the newly-introduced distributions is demonstrated by...
-
Dead-Time Effect Compensation Based on Additional Phase Current Measurements
PublicationThis paper proposes a new method of dead-time effect compensation. The proposed solution is based on additional phase current measurements realized by analog-to-digital converters. These measurements are carried out at the time instants specified by a pulsewidth-modulation (PWM) strategy. This makes it possible to estimate inverter currents at the commutation instants and, finally, to estimate the voltage error caused by dead time. This...
-
Low-frequency noise in ZrS3 van der Waals semiconductor nanoribbons
PublicationWe report the results of the investigation of low-frequency electronic noise in ZrS3 van der Waals semiconductor nanoribbons. The test structures were of the back-gated field-effect-transistor type with a normally off n-channel and an on-to-off ratio of up to four orders of magnitude. The current–voltage transfer characteristics revealed significant hysteresis owing to the presence of deep levels. The noise in ZrS3 nanoribbons...
-
[PP.17.01] INCREASED INSPIRATORY RESISTANCE AFFECTS THE CARDIAC CONTRIBUTION TO THE RELATIONSHIP BETWEEN BLOOD PRESSURE AND PIAL ARTERY PULSATION OSCILLATIONS
PublicationThere is increasing evidence that heart performance directly influences cerebral perfusion. We hypothesised that increased inspiratory resistance would affect the cardiac contribution to the relationship between blood pressure and pial artery pulsation oscillations.
-
Impact of Low Switching-to-Fundamental Frequency Ratio on Predictive Current Control of PMSM: A simulation study
PublicationPredictive current control algorithms for permanent magnet synchronous (PMSM) drives rely on an assumption that within short intervals motor currents can be approximated with linear functions. This approximation may result either from discretizing the motor model or from simplifications applied to the continuous-time model. As the linear current approximation has been recognized as inaccurate in case when the drive operates with...
-
Systolic blood pressure control prevents cognitive decline and slows development of white matter lesions in the brain: the SPRINT MIND study outcomes
Publication -
Decoupled Kalman filter based identification of time-varying FIR systems
PublicationWhen system parameters vary at a fast rate, identification schemes based on model-free local estimation approaches do not yield satisfactory results. In cases like this, more sophisticated parameter tracking procedures must be used, based on explicit models of parameter variation (often referred to as hypermodels), either deterministic or stochastic. Kalman filter trackers, which belong to the second category, are seldom used in...
-
Independent dynamics of low, intermediate, and high frequency spectral intracranial EEG activities during human memory formation
PublicationA wide spectrum of brain rhythms are engaged throughout the human cortex in cognitive functions. How the rhythms of various frequency ranges are coordinated across the space of the human cortex and time of memory processing is inconclusive. They can either be coordinated together across the frequency spectrum at the same cortical site and time or induced independently in particular bands. We used a large dataset of human intracranial...
-
Performance Measurements of Real Time Video Transmission from Car Patrol
PublicationThe HSUPA technology application to video streaming from moving vehicle to the central server is presented in the paper. A dedicated software for transmission control in case of non public IP address is employed. Quality of video streaming in urban area was measured. Several car routes were investigated in the area of the Polish Tricity. Measurements pointed out that the real time streaming quality during vehicle movement is sufficient...
-
Low-frequency noise in Au-decorated graphene–Si Schottky barrier diode at selected ambient gases
PublicationWe report results of the current–voltage characteristics and low-frequency noise in Au nanoparticle (AuNP)-decorated graphene–Si Schottky barrier diodes. Measurements were conducted in ambient air with addition of either of two organic vapors, tetrahydrofuran [(CH2)4O; THF] and chloroform (CHCl3), as also during yellow light illumination (592nm), close to the measured particle plasmon polariton frequency of the Au nanoparticle...
-
Noise measurements on low noise pavements - problems with inhomogeneity of wearing course
PublicationDuring the last several years, when performing numerous CPX noise measurements on low noise pavements,significant inhomogeneity of the wearing course was observed in numerous cases. Similar problems were almost not existing regarding to the dense pavements.In general three main reasons of inhomogeneity can be defined. The first one are imperfections in technology of production of a asphalt mix or/and errors made already during...
-
Increased inspiratory resistance alters the cardiac contribution to the dynamic relationship between blood pressure and pial artery pulsation oscillations in healthy subjects
PublicationThere is increasing evidence that heart performance directly influences cerebral perfusion. We hypothesised that increased inspiratory resistance will affect the cardiac contribution to the relationship between blood pressure and pial artery pulsation oscillations.
-
A Low-Cost System for Far-Field Non-Anechoic Measurements of Antenna Performance Figures
PublicationPrototype measurements are the key step in the development of antenna structures. Typically, their far-field characteristics are validated in expensive, dedicated facilities such as open range sites, or anechoic chambers. Despite being necessary for obtaining high-precision data (e.g., for device qualification), the use of costly infrastructure might not be fully justified when the main goal of measurements includes demonstration...
-
Validation of a sampling procedure
PublicationEach step of the analytical procedure influences the final results in a significant way. In the majority of cases the analytical procedure encompasses sampling because the analysis of the entire object (material) is usually not possible. Thus it is necessary to include the uncertainty related to sampling procedure in the uncertainty budget calculations. This paper describes two basic ways of estimating the sampling uncertainty,...
-
Measuring Pulse Rate with a Webcam
PublicationIn this paper a simple method of measuring the pulse rate is presented. Elaborated algorithm allows for efficient pulse rate registration directly from face images captured from a webcam. The desired signal is obtained by proper channel selection and principal component analysis. To determine the accuracy of the method an ECG signal is collected together with a video recordings. The effectiveness of the algorithm is considered...
-
A simulation investigation into the signal reconstruction accuracy of the transducer with pulse frequency output
Publication -
Renal denervation achieved by endovascular delivery of ultrasound in RADIANCE-HTN SOLO or by radiofrequency energy in SPYRAL HTN-OFF and SPYRAL-ON lowers blood pressure
Publication