Search results for: VERTICAL DISPLACEMENT, HYDROSTATIC LEVELLING SYSTEMS, REFERENCE SENSOR, CONTROLLED SENSORS
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 290 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 170 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 280 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 150 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 230 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 240 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 220 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.2
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.1
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Assessment of Electronic Sensing Techniques for the Rapid Identification of Alveolar Echinococcosis through Exhaled Breath Analysis
PublicationHere we present a proof-of-concept study showing the potential of a chemical gas sensors system to identify the patients with alveolar echinococcosis disease through exhaled breath analysis. The sensors system employed comprised an array of three commercial gas sensors and a custom gas sensor based on WO3 nanowires doped with gold nanoparticles, optimized for the measurement of common breath volatile organic compounds. The measurement...
-
System of monitoring of the Forest Opera in Sopot structure and roofing
PublicationThe authors present a solution realized in Forest Opera (name in Polish: Opera Leśna) in Sopot (Poland) in connection with the modernization and construction of a new roof. The complicated structure of the roof of the facility and the used covering in form of membrane made of technical fabric required (for security reasons) to install the unit of devices allowing for the continuous geodetic monitoring of the facility. Monitoring...
-
Reliability data safety instrumented systems SIS from the functional safety analysis example critical instalation
Open Research DataThe dataset represents the results of an example of functional safety analysis systems is presented below. It is based on a control system, which consists of some basic components like sensors, programmable logic controllers and valves. It is a part of petrochemical critical installations. The communication between sensor logic controllers and actuators...
-
Mechanical Properties of Aluminium Bracket Strengthening
PublicationThe aim of the research is laboratory investigation of aluminium brackets employed to fasten lightweight curtain walls to building facilities. Tensile loads perpendicular to end plates (vertical) were applied here. The author focused on the solutions intended to increase the load-carrying capacity of aluminium brackets applying the plain washer form A (DIN 125; ISO 7089), plain washer with an outer diameter about 3d (DIN 9021;...
-
On Rapid Design Optimization and Calibration of Microwave Sensors Based on Equivalent Complementary Resonators for High Sensitivity and Low Fabrication Tolerance
PublicationThis paper presents the design, optimization, and calibration of multivariable resonators for mi-crowave dielectric sensors. An optimization technique for circular complementary split ring reso-nator (CC-SRR) and square complementary split ring resonator (SC-SRR) is presented to achieve the required transmission response in a precise manner. The optimized resonators are manufac-tured using a standard photolithographic technique...
-
An electronic nose for quantitative determination of gas concentrations
PublicationThe practical application of human nose for fragrance recognition is severely limited by the fact that our sense of smell is subjective and gets tired easily. Consequen tly, there is considerable need for an instrument that can be a substitution of the human sense of smell. Electronic nose devices from the mid 1980s are used in growing number of applications. They comprise an array of several electrochemical gas sensors...
-
Multiparameter sensitivity analysis of a GFRP composite footbridge of a sandwich structure and U-shaped cross-section
PublicationThe paper deals with multiparameter sensitivity analysis of a composite footbridge. A shell‐like structure is 14.5 m long shows U‐shaped cross‐section and inner service dimensions 1.3 × 2.5 m. Glass fiber reinforced polymer GFRP laminate constitutes faces of a sandwich structure while PET foam received from recycled bottle builts a core. The structure was divided into 285 independent areas where the thickness of laminates and stiffness...
-
Measurement spectrum obtained with the use of ZnO coated (100 nm) microsphere-based fiber-optic sensor - 200 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 100 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated (100 nm) microsphere-based fiber-optic sensor - 100 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 100 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated (100 nm) microsphere-based fiber-optic sensor - 300 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 100 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Gas sensors based on conducting polymers-recent developments
PublicationThis work discusses sensing performance dependence of PEDOT polymer and its composites on the counter ions used in the polymerization process. The sensors based on PEDOT-RGO composite show reversible response to NO2, while on PEDOT/LiClO4 irreversible. As a result, PEDOT-RGO could be used as a typical gas sensor, while sensor based PEDOT/LiClO4 could be used as an integrating gas sensor, also known as an accumulating gas sensor....
-
An Implementation of a Compact Smart Resistive Sensor Based on a Microcontroller with an Internal ADC
PublicationIn the paper a new implementation of a compact smart resistive sensor based on a microcontroller with internal ADCs is proposed and analysed. The solution is based only on a (already existing in the system) microcontroller and a simple sensor interface circuit working as a voltage divider consisting of a reference resistor and the resistive sensor connected in parallel with an interference suppression capacitor. The measurement...
-
SAMPLE-AND-HOLDING METHOD FOR GAS SENSING APPLIED FOR RESISTANCE GAS SENSORS
PublicationThe DC resistance of a Taguchi gas sensor is influenced by the ambient gas. To improve the selectivity and sensitivity of a sensor the fluctuation enhanced sensing (FES) was used. The paper proposes a novel methodology of utilizing FES technique that sample composition of an ambient atmosphere and hold it for further processing (sample-and-holding technique). The method uses the heated gas sensor to sample an ambient atmosphere...
-
Methodology for assessing end-user requirements in the Ella4Life project: elders’ perspectives about self-monitoring
PublicationThe purpose of this paper is to explore elders’ perspectives about self-monitoring and using specially developed sensor technology for measuring health indicators. The qualitative research method is focus-groups with guidelines that were designed for understanding elder’s requirements about monitoring health indicators. We present them two devices: the first sensor is a device for monitoring of cardiac action potential fixed into...
-
IEEE International Conference on Distributed Computing in Sensor Systems
Conferences -
IMPEDANCE MEASUREMENT MODULE FOR GAS SENSORS WITH TEMPERATURE CONDITIONING FEATURE
PublicationThe paper presents an impedance measurement module which is aimed for gas sensor. Sensor’s heater temperature conditioning and modulation feature is available in order to allow implementation of different techniques improving selectivity and sensitivity of gas sensors. The measurement module uses three-parameter sine-fitting technique for impedance measurement. To monitor sensor temperature, the resistance of the sensor’s heater...
-
On-line measurement of wood surface smoothness
PublicationThe latest progress in the field of optics and microelectronics resulted in development of new generation vision systems capable of scanning surface topography with very high sampling frequencies. The blue color of illuminating light as well as novel systems for controlling ultra-thin laser line thickness allows measurement of the porous surface of wood with a triangulation method. Three alternative sensors were tested here in...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.4
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.5
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.3
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Mathematical and numerical modelling,W,IDE-EMSS,IIst,sem.01,lato,2023/24 (PG_00057379)
e-Learning CoursesModelling of controlled mechanical systems by the mixed method of rigid and flexible finite elements: The finite element volume problems. Dynamics of multibody systems. Modelling of stationary closed loop systems. Modelling of systems whose configuration changes with time. Modelling of nonlinear controlled systems. Optimal control at energy performance index: Control of continuous nonstationary systems in domain of generalised...
-
Mathematical and Numerical Modelling, L, IDE IInd, sem.01, summer, 2022/23(00057379)
e-Learning CoursesModelling of controlled mechanical systems by the mixed method of rigid and flexible finite elements: The finite element volume problems. Dynamics of multibody systems. Modelling of stationary closed loop systems. Modelling of systems whose configuration changes with time. Modelling of nonlinear controlled systems. Optimal control at energy performance index: Control of continuous nonstationary systems in domain of generalised...
-
Efficiency of linear and non-linear classifiers for gas identification from electrocatalytic gas sensor
PublicationElectrocatalytic gas sensors belong to the family of electrochemical solid state sensors. Their responses are acquired in the form of I-V plots as a result of application of cyclic voltammetry technique. In order to obtain information about the type of measured gas the multivariate data analysis and pattern classification techniques can be employed. However, there is a lack of information in literature about application of such...
-
A novel concept for tissue-metal detection and differentiation using an inductive proximity sensor
PublicationIn this paper a novel application of inductive proximity sensors for detection of living tissue by means of measurements of the coil impedance changes at different frequencies is described. The mathematical analyses utilizing Bessel function estimation include detected object size and its distance from a sensor. The main aim of this study is to prove the possibility of distinguishing between metal objects and living tissues. The...
-
A Novel IoT-Perceptive Human Activity Recognition (HAR) Approach Using Multi-Head Convolutional Attention
PublicationTogether with fast advancement of the Internet of Things (IoT), smart healthcare applications and systems are equipped with increasingly more wearable sensors and mobile devices. These sensors are used not only to collect data, but also, and more importantly, to assist in daily activity tracking and analyzing of their users. Various human activity recognition (HAR) approaches are used to enhance such tracking. Most of the existing...
-
Investigation of Weigh-in-Motion Measurement Accuracy on the Basis of Steering Axle Load Spectra
PublicationWeigh-in-motion systems are installed in pavements or on bridges to identify and reduce the number of overloaded vehicles and minimise their adverse eect on road infrastructure. Moreover, the collected trac data are used to obtain axle load characteristics, which are very useful in road infrastructure design. Practical application of data from weigh-in-motion has become more common recently, which calls for adequate attention to...
-
INVESTIGATION OF ACIDIC SOLUTIONS BY POTENTIOMETRIC TASTE SENSOR WITH ALL SOLID STATE ELECTRODES
PublicationPotentiometric taste sensors with electrodes containing lipophilic compound / polymer membranes were already used to distinguish commercial liquid products. In this paper a new potentiometric taste sensor consisting of six All Solid State Electrodes (ASSEs) has been presented. Each of the membrane contains a selected lipophilic compound. The set-up consists of a reference electrode and six ASSEs. The inner layer made of a conducting...
-
The radiated immunity test of an astable multivibrator for various supply voltages
Open Research DataThe dataset presents a result of measurements that are a part of electromagnetic field immunity tests. The radiated, radio frequency, immunity tests were carried out for a typical astable electronic multivibrator supplied from a power supply with an output voltage of 6V and 7.5 V. Tests of immunity of electronic systems to radiated radio frequency (RF)...
-
Functionalization of indium-tin-oxide electrodes by laser-nanostructured gold thin films for biosensing applications
Publicationof a relatively large area formed by pulsed laser nanostructuring of thin gold films arereported and discussed. The SEM inspection of modified electrodes reveals the presence of the nearlyspherical and disc-shaped particles of dimensions in the range of 40–120 nm. The NP-array geometry canbe controlled by selection of the laser processing conditions. It is shown that particle size and packingdensity of the array are important factors...
-
Fuctional structure of diagnostic system for wheeled tractors
PublicationAn application of computer controlled fuel injection systems in vehicle engines and growing demands concerning toxic substances emission and fuel consumption was a main reason for OBD (On Board Diagnosis) development. In spite of a great technological development, only some tractors are equipped in diagnostic systems. On board diagnosis is strongly connected with emission demands and does not concern other important vehicle functions.In...
-
An application of simulation model of fuel consumption in diagnostic system of wheeled tractors
PublicationAn application of computer controlled fuel injection systems in vehicle engines and growing demands concerning toxic substances emission and fuel consumption was a main reason for OBD (On Board Diagnosis) development. In spite of a great technological development, only some tractors are equipped in diagnostic systems. On board diagnostic is strongly connected with emission demands and does not concern other important vehicle functions. In...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 130 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 110 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 120 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 100 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
An NO2 sensor based on WO3 thin films for automotive applications in the microwave frequency range
PublicationA microwave system dedicated to the detection of nitrogen dioxide in the harsh environment of the Norway highways is proposed. An optimized transmission line type of sensor coated with a tungsten trioxide thin film that changes its electrical properties under NO2 gas exposure is developed. The sensors' response (S) is given in °/GHz and it is calculated based on wideband measurements. The advantage of wideband measurements in comparison...
-
ZnO ALD-Coated Microsphere-Based Sensors for Temperature Measurements
PublicationIn this paper, the application of a microsphere-based fiber-optic sensor with a 200 nm zinc oxide (ZnO) coating, deposited by the Atomic Layer Deposition (ALD) method, for temperature measurements between 100 and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor head in real-time, which allows for higher accuracy during...
-
Highly sensitive microwave sensors based on open complementary square split-ring resonator for sensing liquid materials
PublicationThis paper presents high-sensitivity sensors based on open complementary square split-ring resonator and modified open complementary split-ring resonator operating at 4.5 GHz and 3.4 GHz, respectively. The sensors are designed for the detection of multiple liquid materials, including distilled water, methanol, and ethanol. The liquid under test is filled in a glass container loaded using a pipette. Compared to the conventional...
-
Features extraction from the electrocatalytic gas sensor responses
PublicationOne of the types of gas sensors used for detection and identification of toxic-air pollutant is an electrocatalytic gas sensor. The electrocatalytic sensors are working in cyclic voltammetry mode, enable detection of various gases. Their response are in the form of I-V curves which contain information about the type and the concentration of measured volatile compound. However,...
-
Data Integration from GPS and Inertial Navigation Systems for Pedestrians in Urban Area
PublicationThe GPS system is widely used in navigation and the GPS receiver can offer long-term stable absolute positioning information. The overall system performance depends largely on the signal environments. The position obtained from GPS is often degraded due to obstruction and multipath effect caused by buildings, city infrastructure and vegetation, whereas, the current performance achieved by inertial navigation systems (INS) is still...
-
Twenty years' (1996-2016) tropospheric parameters for selected EPN stations derived from GPS double-difference processing
Open Research DataPropagation of global navigation satellite systems (GNSS) signals through the Earth’s atmosphere is affected by its physical properties. Both hydrostatic and wet part of the atmosphere (mostly related with troposphere) causes delays of GNSS signal, which usually are expressed in the zenith direction (zenith hydrostatic delay - ZHD, and zenith wet delay...