Filters
total: 5916
-
Catalog
displaying 1000 best results Help
Search results for: REACTIVE POWER, MATRIX CONVERTER, VOLTAGE SOURCE INVERTER, REACTIVE POWER COMPENSATOR, MULTILEVEL INVERTER
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 3 V
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 1 V
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 10 V
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
Measurements of no-load and short-circuit parameters of power transformers with taps
Open Research Data1) The Laboratory LINTE^2 is a large research infrastructure operated by the Faculty of Electrical and Control Engineering at Gdańsk University of Technology, to be found in Gdańsk, Poland (54.3690 N, 18.6130 E).
-
Feasibility Study of Three-Phase Modular Converter for Dual-Purpose Application in DC and AC Microgrids
PublicationThe modern concept of a universal converter is intended as a power converter (PC) suitable for application in both dc or ac grids using the same external connectors. This novel family was recently proposed to allow easier integration of renewable energy sources and energy storage systems (ESSs), interfacing with dc/ac grids and/or loads with a minimum redundancy of power switches and passive elements. This kind of solution and...
-
Static Shunt PE Voltage-Quality Controllers
PublicationThis chapter focuses on power electronics (PE)-based solutions used in distribution networks for reduction of supply-voltage-quality deterioration, from long interruptions to the harmonics. Various PE devices and their combinations are addressed for particular or a range of voltage disturbances. A particular solution is applied taking into account demands for voltage quality and network configuration. In general, there are three...
-
Research of Emergency Modes of Wind Power Plants Using Computer Simulation
PublicationThe aim of this study is to investigate changes in the wind power plant energy production parameters under the conditions of sudden wind changes and voltage drop. To achieve these goals, a simulation of operation of wind power plants was performed. Twelve wind turbines with variable rotational speed equipped with a Fuhrländer FL 2500/104 asynchronous double-fed induction generator (DFIG) were used, each with an installed capacity...
-
The forming and emission of high power electromagnetic pulses
PublicationAn impulse energy source, a power conditioning system and an electromagnetic field emitter are essential to generate an electromagnetic field pulse (EMFP) with a specific frequency bandwidth. Selected simulation results for a power conditioning system consisting of a fuse opening switch and a paraboloidal electromagnetic emitter have been presented in this article. The synthetic system examined in the simulation is powered by an...
-
Hybrid Modulation for Modular Voltage Source Inverters with Coupled Reactors
PublicationThis paper proposes and discusses a concept of a hybrid modulation for the control of modular voltage source inverters with coupled reactors. The use of coupled reactors as the integrating elements leads to significant reduction in the size and weight of the circuit. The proposed modulation combines novel coarsely quantized pulse amplitude modulation (CQ-PAM) and innovative space-vector pulse width modulation (SVPWM). The former...
-
The forming and emission of high power electromagnetic pulses
PublicationAn impulse energy source, a power conditioning system and an electromagnetic field emitter are essential to generate an electromagnetic field pulse (EMFP) with a specific frequency bandwidth. Selected simulation results for a power conditioning system consisting of a fuse opening switch and a paraboloidal electromagnetic emitter have been presented in this article. The synthetic system examined in the simulation is powered by...
-
Four Level Diode-Clamped Back-To-Back Converter with Active DC Link Voltage Control
PublicationThis article presents the design and control of 4L-DC back-to-back converter. To solve the DC link voltage balancing problem in four-level converter a new three-level double chopper topology based on PO-PWM modulation was designed and successfully tested. Also, the paper describes two phase space vector pulse width modulation 2P-SVPWM based on the shape function of finite elements. The control structure with modified Dead-Beat...
-
Measurements of power supply system properties of "Magnetic SpeedLine" ultra-fast robot prototype for IML labeling
Open Research DataTests of the power supply system of "SpeedLine magnetic" ultra-fast industrial robot for IML labeling were carried out to analyze the effect of the active power filter (APF) parameters on the power quality. at the target duty cycle. Tests were performed with the target duty cycle. Linear synchronous motors with permanent magnets were used to drive...
-
IEEE TRANSACTIONS ON POWER ELECTRONICS
Journals -
Measurements of active power coefficients in a ship power station with two generators working in parallel
Open Research DataThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing active...
-
Measurements of active power distribution in a ship power station with two generators working in parallel
Open Research DataThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data expressing an active...
-
EMI attenuation in a DC-DC buck converter using GaN HEMT
PublicationA dc-dc buck converter using gallium nitride (GaN) high electron mobility transistors (HEMT) is experimentally investigated at the discontinuous current mode (DCM) and at the triangular current mode (TCM) operation. The paper objective is to specify the power conversion efficiency and attenuation of common mode (CM) and differential mode (DM) noise voltage, measured at the line impedance stabilization network (LISN) for compared...
-
Electric motor drive with inverter output filter
PublicationPrzedstawiono zagadnienie sterowania i estymacji w układzie napędowym z silnikiem indukcyjnym i filtrem sinusoidalnym.Filtr użyty jest do wygładzenia prądu i napięcia silnika. Filtr wprowadza spadek napięcia i przesunięcie fazowe prądów i napięć uniemożliwiające stosowane bezczujnikowych metod sterowania wektorowego. Rozwiązaniem jest uwzględnienie filtru w sterowaniu i estymacji. Artykuł pokazuje takie rozwiązanie dla metody sterowania...
-
Speed Sensorless AC Drive with Inverter LC Filter and Fault Detection Using Load Torque Signal
PublicationThe industrial development in recent years has seen a major increase in the use of induction motors, whereby the cost has to be as low as possible and the lifetime as long as possible. To follow up this desire, investigations in this area have become very intense. For that reason, this paper presents a solution for driving an induction motor and simultaneous fault detection with no need for additional sensors. In order to achieve...
-
Power-line corridors as source habitat for butterflies in forest landscapes
Publication -
Small hydro-power as a source of renewable energy in the European Union
PublicationW pracy przedstawiono udział odnawialnych źródeł energii w produkcji energii elektrycznej w 25 krajach Unii Europejskiej w roku 1997 i przewidywanu udział w roku 2010. Omówiono krótką historię rozwoju małych elektrownii wodnych w UE i dokonano przeglądu małych elektrowni wodnych w krajach UE oraz w wybranych krajach Europy, nie należących do UE. Przedstawiono także możliwy rozwój małej energetyki wodnej w okresie perspektywicznym...
-
On power stream in motor or drive system
PublicationIn a motor or in a drive system the quantity of power increases in the direction opposite to the direction of power flow. Energy losses and energy efficiency of a motor or a drive system must be presented as functions of physical quantities independent of losses. Such quantities are speed and load. But the picture of power stream in a motor or in a drive system is presented in the literature in the form of traditional Sankey...
-
THE PHASE SHIFTERS INFLUENCE ON THE POWER SYSTEM STABILITY
PublicationThe paper presents the effect of phase shifters as FACTS devices on the possibility of improving the angle stability. Presented results obtained by the dynamic simulation performed on the mathematical model of the three machine system cooperating with the 400 kV network. The generative blocks models include turbine models with their controllers and models of synchronous generators with their excitation systems and voltage regulation....
-
Utilisation of waste heat from the power plant by use of the ORC aided with bleed steam and extra source of heat
PublicationUtilization of waste heat recovered from the exhaust gases of the power generation unit by means of ORC (organic Rankine cycles) installation is considered. The waste heat is available in the form of a stream of hot water having temperature of 90 stC in the amount of 200 MWt. To increase evaporation temperaturę of ORC working fluid the heat of steam from the extraction points from the low-pressure part of steam turbine is used....
-
The conducted immunity test of a power supply unit in accordance with EMC standards
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 150 kHz to 230 MHz are...
-
Inline Waveguide Filter With Transmission Zeros Using a Modified-T-Shaped-Post Coupling Inverter
PublicationThis letter reports the design techniques for a class 2 of inline waveguide bandpass filters with sharp-rejection capabil3 ities at the lower stopband based on a novel nonlinear-frequency4 variant-coupling (NFVC) structure. The proposed NFVC consists 5 of a modified-T-shaped metallic post (MTP) that is placed at the 6 center of the waveguide broad wall with its open arms lying 7 along the waveguide width. The engineered NFVC structure 8...
-
T cell Activation Is Driven by an ADP-Dependent Glukosinase Linking Enhanced Glycolysis with Mitochondrial Reactive Oxygen Species Generation
PublicationMitochondria-originating reactive oxygen species control T cell receptor (TCR)-induced gene expression. Here, we show that TCR-triggered activation of ADP-dependent glucokinase (ADPGK), an alternative, glycolytic enzyme typical for Archaea, mediates generation of the oxidative signal. We also show that ADPGK is localized in the endoplasmic reticulum and suggest that its active site protrudes toward the cytosol. The ADPGK-driven...
-
Balancing energy consumption in limited power grid with active front-end and three phase dual active bridge system
PublicationPaper deals with simulation analysis of bidirectional power converters system for charging station of electric vehicle in condition of limited power source in city infrastructure. In case of incapability to provide additional power supply through the grid by virtue of historical, architectural and economic reasons it is possible to solve this issue by implementation of mobile battery-powered supply source. The proposed bidirectional...
-
INCREASING POWER SUPPLY SAFETY IN THE ASPECT OF SUPPORTING THE RENEWABLE ENERGY SOURCES BY CONVENTIONAL AND VIRTUAL POWER STORES
PublicationThis paper presents characteristics and purposefulness of supporting the renewable energy sources (OZE) by means of energy stores. The main emphasis was placed on analysis of virtual energy stores available for implementation in Polish economy conditions. A role which management of Demand Side Response (DSR) may play in balancing Polish electric power system, is discussed. Implementation of such solutions together with conventional...
-
Power equalization of AES FPGA implementation
PublicationThis paper briefly introduces side channel attacks on cryptographic hardware with special emphasis on differential power analysis(DPA). Based on existing countermeasures against DPA, design method combining power equalization for synchronous and combinatorialcircuits has been proposed. AES algorithm has been implemented in Xilinx Spartan II-E field programmable gate array (FPGA) deviceusing the standard and power-equalized methods....
-
Measurements of apparent power distribution in a ship power station with two generators working in parallel
Open Research DataThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing an apparent...
-
Effect of contactless hybrid current limiter on voltage dips in power system
PublicationW referacie przedstawiono działanie hybrydowego niskonapięciowego ogranicznika prądu zwarciowego, składającego się z ultraszybkiego bezpiecznika, tranzystora mocy i warystora. W szczególności omówiono możliwości polepszenia jakości dostarczanej do odbiorców energii elektrycznej. Zastosowanie hybrydowego ogranicznika prądu znacznie ogranicza czasy trwania zapadów napięcia w systemie elektroenergetycznym. Obliczenia wykonano przy...
-
Effect of contactless hybrid current limiter on voltage dips in power system.
PublicationW referacie przedstawiono działanie hybrydowego niskonapięciowego ogranicznika prądu zwarciowego, składającego się z ultraszybkiego bezpiecznika, tranzystora mocy i warystora. W szczególności omówiono możliwości polepszenia jakości dostarczanej do odbiorców energii elektrycznej. Zastosowanie hybrydowego ogranicznika prądu znacznie ogranicza czasy trwania zapadów napięcia w systemie elektroenergetycznym. Obliczenia wykonano przy...
-
Recreation of Voltage Fluctuation Using Basic Parameters Measured in the Power Grid
Publication -
Modelling of Voltage Transformer Performance in Power System Harmonic Frequency Range
PublicationZniekształcenia harmoniczne napięć i prądów występujące we współczesnych systemach energetycznych powodują liczne problemy pomiarowe. W referacie przedstawiono analizę właściwości przekładników napięciowych stosowanych w sieciach SN i WN w zakresie częstotliwości mierzonych zniekształceń harmonicznych. Opracowany szerokopasmowy model obwodowy został zweryfikowany symulacyjnie i eksperymentalnie. Wyniki przeprowadzonych badań potwierdzają...
-
Modelling of voltage transformer performance in power system harmonic frequency range
PublicationZniekształcenia harmoniczne napięć i prądów występujące we współczesnych systemach energetycznych powodują liczne problemy pomiarowe. W referacie przedstawiono analizę właściwości przekładników napięciowych stosowanych w sieciach SN i WN w zakresie częstotliwości mierzonych zniekształceń harmonicznych. Opracowany szerokopasmowy model obwodowy został zweryfikowany symulacyjnie i eksperymentalnie. Wyniki przeprowadzonych badań potwierdzają...
-
Instantaneous power signal measurements for bearing diagnostics
Open Research DataBearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous current and voltage power supplied to the engines. Bearing damage causes the appearance of deformations, which are in the form of additional harmonic components...
-
Combined Heat & Power Generating Systems
PublicationSteam cycles in combined heat and power plants. Efficiency of combined heat and power systems. Characteristics of steam-turbine CHP plants. Choice of equipment in CHP generating systems. Economic effects of combined heat and power production. Costs and energy produced CHP generating systems. Future development trends in CHP generating systems.
-
Modern Arrangement for Reduction of Voltage Perturbations
PublicationThe contents of this chapter encompass general problems and the most important issues of power-supply-quality improvement in AC systems. In the context of the above, consideration is given to evaluation of bilateral interactions of receivers with an electrical power-distribution system and methods of their reduction. Also are discussed the basis of operation of the most important compensation-filtration devices and their applications...
-
Energy losses in hydrostatic drive:Drive investigation method compatible with diagram of power increase opposite to the direction of power flow
PublicationEnergy losses and efficiency of drive motor must be presented as functions of physical quantities independent of losses in the motor. Such quantities are speed and load required by the driven device, changing in the drive operating field. Speed and load decide of the useful power and, in differentiated way, of kinds and values of losses in the motor. But energy losses and efficiency of drive motors are evaluated as functions of...
-
Measurements of the coefficients of active power distribution between two generators operating in parallel in a ship power station
Open Research DataThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing coefficients...
-
Lagrangian model of an isolated dc-dc converter with a 3-phase medium frequency transformer accounting magnetic cross saturation
PublicationThis article presents a nonlinear equivalent circuit model of an isolated dc-dc converter with a 3-phase medium frequency transformer. The model takes into account the magnetic cross saturation of the 3-phase core-type magnetic circuit. The model is suitable in detailed electromagnetic transient simulations of power systems involving isolated dc-dc converters. The model is developed using the Lagrange energy method. It involves...
-
Piotr Dworakowski dr
PeoplePiotr Dworakowski received the MSc degree and PhD degree with distinction in electrical engineering from Gdansk University of Technology, Poland, in 2007 and 2020 respectively. From 2008 to 2013 he was working in Alstom Transport, Tarbes, France on traction drives control. Since 2014 he has been a Power Converters Team Leader in SuperGrid Institute, Lyon, France. His research interests include high efficiency power converters for...
-
Impact of configuration of earth continuity conductor on induced sheath voltages in power cables
PublicationIn high voltage power cable systems a problem of induced sheath voltages exist. Due to these voltages electric shock and damage of non-metallic outer sheath of the cables may occur. Exposure to voltage of the outer sheath may be very high in case of earth fault with high value of earth current. In order to reduce induced sheath voltages an earth continuity conductor (conductors) along power cables is applied. Configuration of this...
-
VSC converters control for offshore wind farms HVDC grid connection
PublicationThe paper proposes a voltage sourced converter (VSC) new control method. A well-known in the electric power systems correlation between voltage angle and active power and correlation between voltage and reactive power is used instead of feedforward control. This allows for a fast and almost independent control of active and reactive power flow.
-
The paradigms of power in the Russian Federation
PublicationThis article outlines the position of the Russian Federation in the first decade of the 21th century, seen in its political, economic and military aspects. It attempts to document the fact that Russia, the former world superpower, has turned into a regional power.
-
Induced sheath voltages in 110 kV power cables – case study
PublicationThis paper considers electric shock hazard due to induced sheath voltages in 110 kV power cables. The purpose of this paper is to find an optimal configuration of the power cable system, taking into account electric shock hazard and ability of the system to transfer maximal power. A computer simulations on a computer model of the local power system, comprising high voltage power cables, were carried out. This model enables to analyse...
-
Evaluation of expanded uncertainty of instantaneous power measurement in a bearing diagnostic system.
PublicationThe paper presents the issues concerning the estimation of the expanded uncertainty in the system for the diagnosis of rolling bearings, consisting of transducers: voltage and current voltage, which is used for diagnostic bearing motors method based on the measurement and analysis of the instantaneous power signal consumed by the induction motor. It presents the methodology for assessing the measurement uncertainty and presents...
-
The investment process in the power supply industry
PublicationThe basis for power supply industry programming in a market economy should be the principle of sustainable development, which must take into account maintaining an adequate level of energy security on the one hand, and the aim to preserve the maximum degree of non-renewable resources on the other hand. Therefore, the overriding aim should be a strive to meet the current and prospective demand for energy and fuel, in conjugation...
-
Virtual inertia in Electric Power System
PublicationThe article presents the idea of introducing virtual inertia system to the electric power systems. The virtual inertia aim is to reduce or eliminate the effect of reducing the inertia of the power system as a result of replacing classic electricity generating units with renewable renergy sources (RES). The considerations are ilustrated by a computational example.
-
POWER ENGINEER
Journals