Search results for: MEASUREMENT SET - UP
-
Determination of magnetisation conditions in a Double-Core Barkhausen Noise measurement set-up
PublicationThe magnetic Barkhausen effect is useful forassessing 1D and 2D stress states of ferromagnetic steelobjects. However, its extension to technically importantmaterials, such as duplex anisotropic steels, remains challenging. The determination of magnetisation inside the studied object and the electromagnet for various geometries, materials and magnetisation angles is a key issue.Three-dimensional, dynamic finite element analysis...
-
Photovoltaic demonstration set up
PublicationThe use of photovoltaics is growing rapidly in the industry as well as households. Therefore, educating the public will help them understand solar cell technology, which is becoming more common in everyday life. This paper proposes a demonstrational set-up of photovoltaic panel for the purpose of science education. It was used in numerous outreach activities such as science fairs. Moreover, it proved to be a great tool for education...
-
Low cost set-up for supercapacitors parameters evaluation
PublicationSupercapacitors are capable to store relatively high amount of energy comparing to its mass. Growing number of these devices applications requires development of new testing methods. Standard methods of evaluation of supercapacitor parameters, as cycling voltammetry, CV, galvanostatic cycling with potential limitation, GCPL, impedance measurements, require equipment of high cost...
-
Low cost set-up for supercapacitors parameters evaluation
PublicationWe propose a use of a power amplifier in the circuit of voltage to current converter (current driver) for supercapacitor charging/discharging in controlled conditions. The current driver is controlled by DAC output of DAQ board and voltage of DUT is measured and a control loop is realized by software. In the circuit the DC current method of evaluation of capacitance and equivalent series...
-
Design and Utility of Specialist Comminution Set-Up for Plastics and Organic Materials
Publication -
Measurement of noise parameter set in the low frequency range: requirements and instrumentation.
PublicationOpisano dwa podstawowe szumowe modele metrologiczne czwórnika: ze źródłami szumów odniesionymi do wejścia i ze zwarciowymi prądami szumów. Parametry szumowe opisujące modele zawierające korelację pomiędzy prądami i/lub napięciami są mierzone przy zastosowaniu metod bezpośrednich i pośrednich. Przedstawiono kilka technik redukcji szumów własnych systemu pomiarowego. Szerzej zaprezentowano dwukanałowy system do pomiaru szumów z komputerowym...
-
Cost‐effectiveness of blood pressure measurement and hypertension follow‐up
Publication -
Accelerated large scale test set-up design in natural corrosion marine environment
PublicationThe standards for conducting small-scale specimen tests are well developed, but there is a lack of direct guidelines for conducting corrosion tests for large-scale specimens. The objective here is to develop a methodology which may be used in designing an accelerated corrosion test of large-scale structural components subjected to a natural corrosion marine environment. Different factors influencing corrosion degradation of steel...
-
AN EXPERIMENTAL STUDY OF THE PHOTOCATALYTIC HYDROGEN PRODUCTION IN THE LABORATORY-SCALE SET-UP DEPENDING ON THE PROCESS CONDITIONS
Publication -
LED Light Sources and Their Complex Set-Up for Visually and Biologically Effective Illumination for Ornamental Indoor Plants
PublicationOrnamental plants are often used in indoor environments as part of biophilic design to improve the health and wellbeing of occupants, and to support sustainable, green architecture. Unfortunately, many plants do not thrive and need to be continuously replaced, which is economically unsustainable. The wavelengths and spectrum ratio of commonly used light sources such as light emitting diode (LED), and the lack of an appropriate...
-
A Set of Low-power Microcontroller-based Modules Used for Testing of Small Energy Measurement Methods
PublicationEstimation of energy consumption of low-power devices is not widely discussed in the scientific literature, but this topic is getting more and more popular. Evaluation process of newly developed methods and instrumentation requires carefull treatment. In order to fulfill this niche, the set of micro-power microcontroller based devices was proposed. The devices represent typical energy consuption profiles and allow experimental verification...
-
Measurement of the temperature change of PVCP tissue phantom illuminated by dermatological laser 1.series
Open Research DataApplication of laboratory set-up for characterization of thermal properties of optical tissue phantoms during laser irradiation is presented. The produced system utilizes a thermographic camera VIGOcam v50 and a dermatological laser system with a 975 nm diode laser module. The set-up was used to perform measurements of the temporal and spatial temperature...
-
Spectroscopic wireless sensor of hematocrit level
PublicationAn optical method for hematocrit measurement is presented. The sensor, designed and developed by authors, consists of a spectroscopic set-up and a microcontroller. The work of the sensor is based on measurement of intensity of two selected spectral bands. Tests confirmed the ability of the sensor to determine the hematocrit level with appropriate measurement accuracy. Measurement results can be transmitted via wireless module to...
-
Measurement of the Temporal and Spatial Temperature Distribution on the Surface of PVCP Tissue Phantom Illuminated by Laser Dataset
PublicationThe dataset entitled Measurement of the temporal and spatial temperature distribution on the surface of PVCP tissue phantom illuminated by laser was obtained with a laboratory set-up for characterisation of the thermal properties of optical tissue phantoms during laser irradiation. The dataset contains a single image file representing the spatial temperature distribution on the surface of a PVCP tissue phantom. This thermal image...
-
Measurement of the temporal and spatial temperature distribution on the surface of PVCP tissue phantom illuminated by laser.
Open Research DataApplication of laboratory set-up for characterisation of thermal properties of optical tissue phantoms during laser irradiation is presented. The produced system utilizes thermographic camera VIGOcam v50 and dermatological laser system with a 975 nm diode laser module. The set-up was used to perform measurements of the temporal and spatial temperature...
-
Spectroscopic and wireless sensor of hematocrit level
PublicationAn optical method for hematocrit measurement has been presented. the sensor, designed and developed by authors, consists of spectroscopic set-up controlled by a microcontroller. measurement results are sent via wireless module. experiment has confirmed the ability of the sensor to determine the hematocrit with appropriate measurementaccuracy.
-
Michał Tomasz Kucewicz dr
PeopleMichal Kucewicz was born in 1986 in Gdansk. In 2005 he completed International Baccalaureate programme in Topolowka (III High School in Gdańsk). Thanks to the G. D. Fahrenheit scholarship, he moved to the United Kingdom to study neuroscience. He received his Bachelor’s and Master’s degree from the Cambridge University, and his doctoral degree from the University of Bristol specializing in electrophysiology of memory and cognitive...
-
Long-term measurement of physiological parameters.
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
The use of low-coherence interferometer for sugar content determination
PublicationIn this article, the implementation of low-coherence interferometer with signal processing in time domain for sugar content determination in aqueous solution is presented. The elaborated measurement set-up was tested with the use of synthesized source made of two low-coherence sources. The use of two sources with dedicated parameters enabled to obtain a proper metrological parameters of the measurement system. The elaborated low-coherence...
-
Long-term measurement of physiological parameters (2)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters (4)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters (3)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (2)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (1)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 110 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (3)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (4)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - adult (1)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (2nd serie)
Open Research DataThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (1st serie)
Open Research DataThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Long-term measurement of physiological parameters - child (90 minutes)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
Modelling and Measurement of Folk Guitar: Truss Rod and Strings in Numerical Analysis of Tone
PublicationThe study makes an attempt to model a complete vibrating guitar including its non-linear features, specifically the tension-compression of truss rod and tension of strings. The purpose of such a model is to examine the influence of design parameters on tone. Most experimental studies are flawed by uncertainties introduced by materials and assembly of an instrument. Since numerical modelling of instruments allows for deterministic...
-
Mercury intrusion porosimetry (MIP) results of cement pastes containing Bi2O3/Gd2O3 and silica-coated Bi2O3/Gd2O3 structures
Open Research DataMercury intrusion porosimetry (MIP) data - curves of cement pastes containing Bi2O3/Gd2O3 and silica-coated Bi2O3/Gd2O3 structures
-
Long-term measurement of physiological parameters - a teenager (150 minutes) 1 serie
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 150 minutes) measurement of physiological parameters was performed on the healthy...
-
Investigation of continuous wave jamming in an IEEE 802.15.4 network
PublicationThis paper presents how continuous wave jamming affects IEEE 802.15.4 network. To this end, an office-based measurement setup has been proposed. Within the measurement area, 25 nodes have been set up in order to create a IEEE 802.15.4 tree-based test network structure. A dedicated jamming device that generates and transmits a continuous wave signal has been developed. Several tests have been conducted and presented to demonstrate...
-
Change of exhaust gases concentration for reference SOFC and SOFC with LSCNT layer fueled by biogas mixture at 750 C
Open Research DataThe dataset changes of exhaust gases concentrations (CH4,CO,CO2,H2) over working time for SOFC with La0.27Sr0.54Ce0.09Ni0.1Ti0.9O3-s layer as well as reference SOFEC (unmodified). Concentrations were calculated based on the FTIR measurements and calibration curves presented in different dataset. Longterm measurements of SOFC were performed using in-house...
-
Assessment of Fuel Cells’ State of Health by Low-Frequency Noise Measurements
PublicationWe proposed applying low-frequency (flicker) noise in proton-exchange membrane fuel cells under selected loads to assess their state of health. The measurement set-up comprised a precise data acquisition board and was able to record the DC voltage and its random component at the output. The set-up estimated the voltage noise power spectral density at frequencies up to a few hundred mHz. We observed the evolution of the electrical...
-
Full scattering profile of circular optical phantoms mimicking biological tissue
PublicationHuman tissue is one of the most complex optical media since it is turbid and nonhomogeneous. In our poster, we suggest a new type of skin phantom and an optical method for sensing physiological tissue condition, basing on the collection of the ejected light at all exit angles, to receive the full scattering profile. Conducted experiments were carried out on an unique set-up for noninvasive encircled measurement. Set-up consisted...
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system at sea trials during a bow thruster start-up
Open Research DataThe dataset is a part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. In ships' electrical power systems, disturbances occurring in voltage waveforms on bus bars of the main switchboard are connected mainly with the processes...
-
System Loss in UWB Off-Body Communications in a Ferry Environment
PublicationIn this paper, the system loss in UWB off-body communications in a ferry environment based on measurements is presented. A mobile measurement set-up, consisting of WBAN nodes with UWB DWM1000 modules, was used. System loss was split into LOS and NLOS conditions. For the former, the smallest mean value, 24.4 dB, was obtained for the user approaching the fixed terminal, with the antenna on his chest, and the largest, 28.1 dB, for...
-
Noise spectral density computation based on finite element model of piezoceramic sensor
PublicationThe high sensitivity with wide bandwidth is required for sensor applications in non-destructive testing (NDT). The sensitivity of piezoceramic sensors demands to minimize their noise especially thermal noise, polarisation noise and low frequency 1/f noise,which are the main sources of voltage or current fluctuation in this sort of sensors. For simplicity, only the piezoceramic part of sensor was under study. the theoretical and...
-
Assessment of Supercapacitor’s Quality by Means of Low Frequency Noise
PublicationLow frequency noise is a well-known tool for quality and reliability assessment of electronic devices. This phenomenon is observed in different electrochemical devices as well (e.g., smart windows, electrochemical corrosion processes). Thus, we can assume that the same tool can be used to asses quality of supercapacitors. Their quality is usually determined only by capacitance and/or equivalent series resistance (ESR), or impedance....
-
Sliding friction of alumina (Al2O3) with friction induced vibrations
Open Research DataTest files containing data on experiments in self mated sliding contact of alumina Al2O3 lubricated with either water or paraffin oil. Tests run in variable load/velocity conditions and with different dynamic settings of the test rig (PT-3 tribometer). The aim of the research was to attempt in finding correlations between the dynamic characteristics...
-
Raman spectroscopic investigation of blood and related materials
PublicationThis paper reports preliminary studies on use of Raman spectroscopy for investigation of blood. High quality blood spectra were recorded in-vitro with excitation wavelengths of 830 nm. Because of complex composition of the blood as well as by light attenuation and scattering in the tissues, spectra set up from wide, low-intensive Raman bands and intensive optical background. To get information about origin of bands in Raman spectra...
-
Parameters of land reference points in the Gdynia region and the Free-air anomaly grid of the South Baltic
Open Research DataThe data was registered during the campaign to verify the catalog value of the absolute point coordinates [point 5403 (POLREF-GORA DONAS)] of the national gravimetric control network. The data was recorded in two three-hour stationary measurement campaigns at the following points: Rozewie of the EUREF-POL network, Góra Donas POLREF, and mareograph points...
-
Indoor accelerated controlled corrosion degradation test of small- and large-scale specimens
PublicationThe work presented here is a part of a long-term project analysing the structural behaviour of ageing marine structures. An accelerated corrosion degradation set-up was developed to reproduce corroded marine structural specimens of different degrees of degradation, controlling various natural factors, i.e., temperature, oxygen content, salinity, and flow velocity. The nine stiffened plates of 1.2 m length and 30 small scale specimens...
-
Analysis of exhaled breath for dengue disease detection by low-cost electronic nose system
PublicationThis paper presents a procedure and a set-up of an electronic nose system analyzing exhaled breath to detect the patients suffering from dengue – a mosquito-borne tropical disease. Low-power resistive gas sensors (MiCS-6814, TGS8100) were used to detect volatile organic compounds (VOCs) in the exhaled breath. The end-tidal phase of patients exhaled breath was collected with a BioVOCTM breath sampler. Two strategies were assessed...
-
A nine-input 1.25 mW, 34 ns CMOS analog median filter for image processing in real time
PublicationIn this paper an analog voltage-mode median filter, which operates on a 3 × 3 kernel is presented. The filter is implemented in a 0.35 μm CMOS technology. The proposed solution is based on voltage comparators and a bubble sort configuration. As a result, a fast (34 ns) time response with low power consumption (1.25 mW for 3.3 V) is achieved. The key advantage of the configuration is relatively high accuracy of signal processing,...
-
Experimental results of full scattering profile from finger tissue-like phantom
PublicationHuman tissue is one of the most complex optical media since it is turbid and nonhomogeneous. We suggest a new optical method for sensing physiological tissue state, based on the collection of the ejected light at all exit angles, to receive the full scattering profile. We built a unique set-up for noninvasive encircled measurement. We use a laser, a photodetector and finger tissues-mimicking phantoms presenting different optical...
-
Voltage fluctuations on the main switchgear of the industrial power system supplying the rolling mill motors_part_2
Open Research DataThe dataset presents the voltage waveforms on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data was recorded during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage fluctuations. In the virtual application of flickermeter, a hardware...
-
Investigation of Continuous Wave Jamming in an IEEE 802.15.4 Network
PublicationThis paper presents how continuous wave jamming affects IEEE 802.15.4 network. To this end, an office-based measurement setup has been proposed. Within the measurement area, 25 nodes have been set up in order to create a IEEE 802.15.4 tree-based test network structure. A dedicated jamming device that generates and transmits a continuous wave signal has been developed. Several tests have been conducted and presented to demonstrate...