Filters
total: 982
filtered: 582
-
Catalog
Chosen catalog filters
Search results for: passion
-
THE SYNCHROSQUEEZING METHOD IN BEARING ESTIMATION OF STATIONARY SIGNALS FOR PASSIVE SONAR WITH TOWED ARRAY
PublicationIn this paper, a novel method of bearing estimation in a passive sonar system with a towed array is introduced. The classical approach of bearing estimation based on the spatial spectrum [1] is extended by using the synchrosqeezing method that is a part of the reassignment method introduced by Kodera et al. [2]. Using this method leads to a precise bearing estimation. The proposed method requires a relatively small amount of computation,...
-
Globalized Parametric Optimization of Microwave Passive Components Using Simplex-Based Surrogates
PublicationOptimization-based parameter adjustment involving full-wave electromagnetic (EM) simulation models is a crucial stage of present-day microwave design process. In fact, rigorous optimization is the only reliable mean permitting to simultaneously handle multiple geometry/material parameters, objectives, and constraints. Unfortunately, EM-driven design is a computationally intensive endeavor. While local tuning is usually manageable,...
-
Effect of salinity and pH on the calibration of the extraction of pharmaceuticals from water by PASSIL
Publication -
New Alternative Passive Networks to Improve the Range Output Voltage Regulation of the PWM Inverters
Publication -
Cyclic analysis of thermal impedance of a passive layer of aluminium in a neutral borate buffer solution
PublicationW pracy przedstawiono wyniki badań warstwy pasywnej tworzącej się na stopie 1050 A w warunkach zmieniającej się temperatury. Zmiany realizowano w sposób cykliczny zwiększając a następnie zmniejszając temperaturę. W czasie zmian temperatury prowadzono badania metodę dynamicznej elektrochemicznej spektroskopii impedancyjnej. Stwierdzono największe zmiany parametrów elektrycznego schematu zastępczego w czasie pierwszego cyklu zmian....
-
Laser scanning as a source of information in the analysis of the facades of heritage at risk – the mansion in Kliczewo Male
Publication -
Hydrological signals in polar motion excitation – Evidence after fifteen years of the GRACE mission
Publication -
Incorporation of nitrogen in diamond films - A new way of tuning parameters for optical passive elements
PublicationThis paper investigates the impact of nitrogen incorporation in diamond films for the construction of an interferometric sensor to measure displacement. Diamond films with different nitrogen levels (0–5%) were deposited on silicon substrates by microwave plasma enhanced chemical vapor deposition. The structural characteristics of these samples are characterized using scanning electron microscopy (SEM), atomic force microscopy...
-
Semi-Markow Processes as Models of Devices´ Operating Process of Ship Pro-pulsion System
PublicationReferat zawiera formalny opis procesu eksploatacji urządzeń.
-
Passive layer cracking studies performed on A95056 Aluminum Alloy by DEIS and acoustic emission
PublicationZbadano proces pękania warstwy pasywnej na stopie aluminium A95056 w warunkach zmiennych naprężeń rozciągających i polaryzacji anodowej z wykorzystaniem techniki DEIS oraz emisji akustycznej (AE), jako metody porównawczej. Określono elektrochemiczne i mechaniczne przyczyny badanego procesu. Wyznaczono progową (krytyczną) wartość naprężeń, przy których zarejestrowano proces pękania warstwy pasywnej na badanym stopie aluminium. Badanemu...
-
Application of galvanodynamic impedance spectroscopy for studying passive film cracking under mechanical strain
PublicationThe paper reports the results of simultaneous mechanical and electrochemical investigations on austenitic (18/8) stainless steel in a 2 % solution of sulphuric acid. The measurements were performed using Galvanodynamic Electrochemical Impedance Spectroscopy (GDEIS). Electrochemical analysis of mechanical passive layer cracking and repassivation conditions during a tensile test was carried out. Application of this methodology allowed...
-
Method to determine the critical concentration Rayleigh number in isothermal passive membrane transport processes
Publication -
Passive Variable Fractional Delay Filter Design using Distributed Maximal Flatness Method
PublicationW pracy przedstawiono nową metodę projektowania pasywnych filtrów ułakowoopóźniających opartą na metodzie rozproszonej maksymalnej płaskości. W zaproponowane podejście jest uogólnieniem najbardziej popularnej metody projektowania filtrów maksymalnie płaskich - metody projektowania filtrów maksymalnie płaskich. Filtr maksymalnie płaski cechuje bardzo dobra jakość jedynie w wąskim paśmie wokół częstotliwości zerowej, ale jego istotną...
-
Automatic localization and continous tracking of mobile sound source using passive acoustic radar
PublicationA concept, practical realization and applications of the passive acoustic radar for localization and continuous tracking of fixed and mobile sound sources such as: cars, trucks, aircrafts and sources of shooting, explosions were presented in the paper. The device consists of the new kind of multi-channel miniature three dimensional sound intensity sensors invented by the Microflown company and a group of digital signal processing...
-
New Alternative Passive Networks to Improve the Range Output Voltage Regulation of the PWM Inverters
PublicationThis paper presents different topologies of buck-boost converters with passive input networks that have alternative topologies; this is known in the literature as a Z-source inverter. Alternative passive networks were named by the authors as T-inverters; these improve output voltage regulation of the PWM inverters. T-inverter has fewer reactive components in comparison to conventional Z-source inverter. The most significant advantage...
-
Proof of Concept of Indoor Location System Using Long RFID Readers and Passive Tags
PublicationThe paper proposes a system for persons and objects location with the use of long radio-frequency identifications (RFIDs) readers. In order to investigate all aspects of the proposed location system, several key elements had to be analyzed, including the distance from which the tagged objects and the possibility of using more than one tag within one RFID range at the same time. When designing the system, it is also necessary to...
-
Issues relating to the efficient Application of passive solar protection in multi-family residential buildings
PublicationThe following article is intended to discuss the issues concerning the introduction of passive measures aimed at improving solar protection in multi-family buildings. A system of classifying these methods into two groups of solutions (architectural and material-building) was applied. The first group includes issues concerning facade design, the spatial features of which (such as loggias, balconies and other overhangs) can be treated...
-
1D convolutional context-aware architectures for acoustic sensing and recognition of passing vehicle type
PublicationA network architecture that may be employed to sensing and recognition of a type of vehicle on the basis of audio recordings made in the proximity of a road is proposed in the paper. The analyzed road traffic consists of both passenger cars and heavier vehicles. Excerpts from recordings that do not contain vehicles passing sounds are also taken into account and marked as ones containing silence....
-
Control of the bridge span vibration with high coefficient passive damper. Theoretical consideration and application
PublicationThe research was carried out due to the problem of vibration on the lively pedestrian drawbridge across the Motlawa River in the city of Gdansk. In the design stage, the main span of the footbridge showed unfavorable dynamic properties, which may create a comfort problem for pedestrians. The first vertical bending eigenfrequency was recognized as 1.64 Hz. The original design of the footbridge was equipped with a driving cylinder...
-
Incorporation of nitrogen in diamond films – A new way of tuning parameters for optical passive elements
PublicationThis paper investigates the impact of nitrogen incorporation in diamond films for the construction of an interferometric sensor to measure displacement. Diamond films with different nitrogen levels (0–5%) were deposited on silicon substrates by microwave plasma enhanced chemical vapor deposition. The structural characteristics of these samples are characterized using scanning electron microscopy (SEM), atomic force microscopy (AFM), confocal...
-
The Influence of Microstructure on the Passive Layer Chemistry and Corrosion Resistance for Some Titanium-Based Alloys
PublicationThe effect of microstructure and chemistry on the kinetics of passive layer growth and passivity breakdown of some Ti-based alloys, namely Ti-6Al-4V, Ti-6Al-7Nb and TC21 alloys, was studied. The rate of pitting corrosion was evaluated using cyclic polarization measurements. Chronoamperometry was applied to assess the passive layer growth kinetics and breakdown. Microstructure influence on the uniform corrosion rate of these alloys...
-
The Dilemmas of Choosing a Suitable Technology for Low Energy and Passive Houses in the Context of their Overheating Issues
PublicationIn compliance with European Union directives, numerous countries are introducing increasingly stricter legal limits on the estimated energy consumption of newly designed residential buildings. However, the fact, that regulations and designers' efforts are focused on decreasing energy consumption (and consequently carbon dioxide emissions) only at the post-occupancy stage, may lead to a significant increase in the carbon footprint...
-
Struktura triacylogliceroli olejów z nasion truskawki, maliny i czarnej porzeczki
PublicationPrzedmiotem badań było określenie struktury triacylogliceroli (TAG) olejów z nasion maliny, truskawki i czarnej porzeczki. W TAG badanych olejów pozycje zewnętrzne sn-1 i sn-3 zajmują głównie kwasy nasycone palmitynowy C16:0 i stearynowy C18:0 oraz kwas C18:1 (n-7). Przeważająca ilość kwasu linolowego C18:2 (n-6)występującego w badanych olejach zajmuje pozycje wewnętrzną sn-2. Udział procentowy pozostałych KT w pozycjach sn-1,3...
-
Determination of Volatile Organic Compounds in Indoor Air in the Gdansk Area Using Permeation Passive Samplers
PublicationPassive dosimetry — known for over a hundred years — is still a useful tool in monitoring air pollutants. In this work, permeation passive samplers were used to determine indoor air quality in 22 apartments located in the Gdansk area in the northern part of Poland. The results obtained by the passive sampling technique were compared to those obtained by dynamic sampling. Attempts were also made to identify indoor sources of...
-
Dynamic electrochemical impedance spectroscopy measurements of passive layer cracking under static tensile stresses
Publication -
Determination of Volatile Organic Compounds in indoor air in the Gdansk area using permeation passive samplers.
PublicationDozymetria pasywna, znana od wielu lat, jest użytecznym narzędziem w monitoringu poziomu zanieczyszczeń. Do określenia jakości powietrza wewnętrznego w 22 pomieszczeniach mieszkalnych, zlakoalizowanych na terenie Gdańska, wykorzystano dozymetry pasywne typu permeacyjnego na etapie pobierania próbek analitów. Uzyskane wyniki porównano z wynikami uzyskanymi przy wykorzystaniu matedy dynamicznej. Podjęto również próbę identyfikacji...
-
Developing assumptions for the tram noise attenuation passive system using the noise maps analysis method
PublicationThe paper presents experimental research carried out to determine the possible actions to reduce thenoise generated by trams in a highly urbanised area. A few design strategies affecting tram ride qualityhave been presented – especially in the aspect of the acoustic phenomena. Main sources of the noisein trams were characterised. The paper includes selected results of comprehensive...
-
Effect of housing geometry on the performance of Chemcatcher passive sampler for the monitoring of hydrophobic organic pollutants in water
PublicationZaprojektowano nową obudowę próbnika typu Chemcatcher, tzw. próbnik typu Chemcatcher drugiej generacji. Większość badań kalibracyjnych przeprowadzono stosując próbnik typu Chemcatcher pierwszej generacji. Dlatego zbadano wpływ obudowy próbnika typu Chemcatcher na jego działanie.
-
Key logistics processes in project management based on organisation of an international training session-case study
PublicationImprovement of processes, including the logistics processes forms one of the essential aspects of modern business entities functioning. Search for the solutions allowing for quicker and less costly method of realisation of particular activities in highly significant, especially in the conditions of a dynamically changing environment in which the organisations have to function. It is a natural field occuring principally both in...
-
Study of passive deck-flaps flutter control system on full bridge model. II: Results
PublicationZaprezentowano badania parametryczne systemu sterowania flatterem przy pomocy dołączonych stateczników na modelu wyprowadzonego w formalizmie metody elementów skończnych. Wyniki wskazują na efektywność systemu stosującego symetryczne sprzężenie ruchu stateczników z ruchem skrętnym mostu.
-
Study of passive deck-flaps flutter control system on full bridge model. I: Theory
PublicationSformułowano modele matematyczne drgań mostu z zamontowanym pasywnym systemem sterowania flatterem w formalizmie metody elementów skończonych. System wykorzystuje stateczniki dołączone bezpośrednio do przęsła mostu. Siły aerodynamiczne działające bezpośrednio na most i stateczniki sformułowane są w przestrzeni czasu.
-
Dynamic elektrochemical impedance spectroscopy measurements of passive layer cracking under static tensile stresses.
PublicationDynamiczna elektrochemiczna spektroskopia impedancyjna umożliwia badanie podatności i odporności korozyjnej różnych materiałów konstrukcyjnych, a w szczególności określenie właściwości elektrochemicznych warstw pasywnych występujących na ich powierzchni. W wielu przypadkach pęknięcie warstwy pasywnej pod wpływem działania naprężeń rozciągających prowadzi do korozji naprężeniowej. Z tego względu badania pękania warstw pasywnych...
-
Dynamic electrochemical impedance spectroscopy measurements of passive layer cracking under static tensile stresses.
PublicationDynamiczna Elektrochemiczna Spektroskopia Impedancyjna umożliwia badanie podatności i odporności korozyjnej różnych materiałów konstrukcyjnych, a w szczególności określenie właściwości elektrochemicznych warstw pasywnych występujących na ich powierzchni. W wielu przypadkach pęknięcie warstwy pasywnej pod wpływem działania naprężeń rozciągających prowadzi do korozji naprężeniowej. Z tego względu badania pękania warstw pasywnych...
-
Optimizing of target detection and tracking processes realized on consoles of passive sonar with linear towed antenna
PublicationThe long-range passive towed sonar was first modernised a few years ago. Building on operator experience over that period, a concept was developed of optimising the tasks performed by sonar operators, and improving forms of imaging to inform about object detection and support object tracking. The concept was implemented and successfully tested during ships’ manoeuvres. The optimisation of operator tasks was designed to keep listening...
-
Application of passive sampling technique in monitoring research on quality of atmospheric air in the area of Tczew, Poland.
PublicationThis paper presents the results of atmospheric air quality research in Tczew (adjacent to the Vistula River) on the content of BTEX compounds. Analytical procedure applied during the sampling of the analytes from the air used the passive sampling technique (diffusive passive sampler, Radiello®). For determination of BTEX compounds in atmospheric air, two-stage thermal desorption technique combined with gas chromatography (TD-GC-FID)...
-
Static renewal and continuous-flow calibration of two types of passive samplers for the monitoring of pharmaceuticals in wastewater
Publication -
Limitations of Integrative Passive Samplers as a Tool for the Quantification of Pharmaceuticals in the Environment – A Critical Review with the Latest Innovations
Publication -
A Multichannel Receiver of the Experimental FM Based Passive Radar Using Software Defined Radio Technology
Publication -
The home-made in situ passive flux sampler for the measurement of monoterpene emission flux: preliminary studies
PublicationThe paper presents the construction and metrological characteristics of the home-made in situ passive flux sampler, an analytical tool representing small-scale emission chambers working in situ and passively sampling analytes from the gaseous phase. The sorption element was a cylindrical container made of stainless steel net, packed with a carbon sorbent bed-graphitized charcoal, Carbograph 4 (35/50mesh). The recommended working/exposure...
-
Near-Field Wireless Sensing of Plastics and Papers Using Frugal Peel-Off Passive Tag
PublicationThis article presents a novel frugal approach of testing plastics and papers using a near-field microwave sensing technique with a peel-off tag. The proposed sensing technique involves two electrical entities: the sensor, which may be regarded as a reader, and a disposable tag. The reader is a modified design of a gap-coupled microstrip line (GCML) sensor, while the passive tag is a standard double-ring complementary split-ring...
-
Estimating Traffic Intensity Employing Passive Acoustic Radar and Enhanced Microwave Doppler Radar Sensor
PublicationInnovative road signs that can autonomously display the speed limit in cases where the trac situation requires it are under development. The autonomous road sign contains many types of sensors, of which the subject of interest in this article is the Doppler sensor that we have improved and the constructed and calibrated acoustic probe. An algorithm for performing vehicle detection and tracking, as well as vehicle speed measurement,...
-
Comparing traffic intensity estimates employing passive acoustic radar and microwave Doppler radar sensor
PublicationThe purpose of our applied research project is to develop an autonomous road sign with built-in radar devices of our design. In this paper, we show that it is possible to calibrate the acoustic vector sensor so that it can be used to measure traffic volume and count the vehicles involved in the traffic through the analysis of the noise emitted by them. Signals obtained from a Doppler radar are used as a reference source. Although...
-
An inclination in Thermal Energy Using Nanoparticles with Casson Liquid Past an Expanding Porous Surface
PublicationPhysical aspects of inclined MHD nanofluid towards a stretching sheet embedded in a porous medium are visualized. Two types of nanoparticles are used named as copper and alumna dioxide with water as base fluid. Similarity transformations are used to convert the partial differential equations into the set of ordinary differential equation. Closed solutions are found to examine the velocity and the temperature profiles. It is examined...
-
Time fractional analysis of Casson fluid with application of novel hybrid fractional derivative operator
PublicationA new approach is used to investigate the analytical solutions of the mathematical fractional Casson fluid model that is described by the Constant Proportional Caputo fractional operator having non-local and singular kernel near an infinitely vertical plate. The phenomenon has been expressed in terms of partial differential equations, and the governing equations were then transformed in non-dimensional form. For the sake of generalized...
-
Employment of passive sampling in monitoring indoor air quality in selected residences in a Tri-city area in Poland
PublicationTime-weighted average concentrations of selected volatile compounds were measured in chosen residences in a Tri-City area of Poland by means of passive sampling. The results were compared to those obtained by dynamic technique – sorption tubes filled with Tenax TA sorbent. Results obtained by employing the two techniques were similar. Total volatile organic compound (TVOC) parameters were also determined. An attempt was also...
-
Application of the chromatographic retention index system for the estimation of the calibration constants of permeation passive samplers with polydimethylsiloxane membranes
PublicationThe paper presents the results of research on the calibration of permeation passive samplers equipped with polydimethylsiloxane (PDMS) membranes using the physico-chemical properties of the analytes. Strong correlations were found between the calibration constants of the samplers and the linear temperature-programmed retention indices of the analytes determined on columns coated with pure PDMS (r2 = 0.914). These correlations...
-
Pounding mitigation of a short-span cable-stayed bridge using a new hybrid passive control system
PublicationThis paper investigates the effectiveness of a new hybrid passive control system on the seismic response of an existing steel cable-stayed bridge considering the pounding effect. The proposed hybrid passive control system comprises a seismic isolator and a metallic damper. The bridge is located in a high seismic zone and has suffered several damages including the earthquake-induced pounding damage during the 1988 earthquake....
-
Space Mission Risk, Sustainability and Supply Chain: Review, Multi-Objective Optimization Model and Practical Approach
Publication -
New possibilities of the passive layer cracking dynamics detection using a new Dynamic Electrochemical Impedance Spectroscopy.
PublicationNowa metoda Dynamicznej Elektrochemicznej Spektroskopii Impedancyjnej opracowana w Katedrze Elektrochemii, Korozji i Inżynierii Materiałowej Politechniki Gdańskiej daje możliwości określania charakterystyki impedancyjnej w dziedzinie czasu podczas procesu pękania ochronnej warstwy pasywnej. Fakt ten jest związany z procedurą analizującą wspomnianej techniki, która umożliwia selektywną analizę czasowo-częstotliwościową uzyskanych...
-
Employment of passive sampling in monitoring indoor air quality in selected residences in a Tri-city area in Poland
PublicationNa etapie pobierania próbek analitów zastosowano dwie techniki: pasywną - wykorzystującą permeacyjne dozymetry pasywne oraz technikę klasyczną - wykorzystującą rurki sorpcyjne. Wyznaczono sumaryczną zawartość TVOC lotnych związków organicznych.