Filters
total: 2315
-
Catalog
displaying 1000 best results Help
Search results for: AC LOSS
-
System Loss Model for Body Area Networks in Room Scenarios
PublicationThis paper presents an analysis of system loss in Body Area Networks for room scenarios, based on a wideband measurement campaign at 5.8 GHz. The measurements were performed with a fixed antenna transmitting vertically and horizontally polarised signals, while the user wears dualpolarised antennas. The average system losses in co- and crosspolarised channels are 41.4 and 42.6 dB for vertically polarised transmitted signals and...
-
Edukacyjne narzędzie do badania zjawisk zachodzących podczas konwersji AC/CA
PublicationW pracy przedstawiono software'owe narzędzie umożliwiające analizę jakości karty dźwiękowej zainstalowanej komputerze PC opracowane na potrzeby laboratorium przetwarzania sygnałów. Oprogramowanie to w bardzo prostym, powszechnym systemie, jakim jest komputer PC z kartą dźwiękową, pozwala na zapoznanie się z wieloma typowymi problemami praktycznymi spotykanymi przy konwersji analogowo-cyfrowej (AC) i cyfrowo-analogowej (CA).
-
Resonant DC link inverters for AC motor drive systems – critical evaluation
PublicationIn this survey paper, resonant and quasiresonant DC link inverters are reexamined for AC motor drive applications. Critical evaluation of representative topologies is based on simulation and waveform analysis to characterize current/voltage stress of components, control timing constraints and feasibility. A special concern over inverter common-mode voltage and voltage gradient du/dt limitation capacity is discussed for motor bearing...
-
Motor Cable Effect on the Converter Fed AC Motor Common Mode Current
PublicationAnaliza zaburzeń elektromagnetycznych przewodzonych w przekształtnikowych układach napędowych wymaga uwzględniania pojemności pasożytniczych występujących w przekształtniku, uzwojeniach silnika oraz kablu zasilającym silnik. Dynamiczne zmiany napięć na uzwojeniach silników zasilanych z przekształtników częstotliwości PWM oraz związane bezpośrednio z nimi składowe wspólne prądów zaburzeń przewodzonych są istotnie związane z zjawiskami...
-
High Frequency Harmonics Emission of Modern Power Electronic AC-DC Converters
PublicationModern AC/DC converters with bidirectional power flow employing PWM boost topology generate harmonic distortions of input current in relatively high frequency range tightly related to modulation carrier frequency. These frequencies and its multiples in typical applications are usually located in frequency range from single up to several of kHz. Increased harmonic emission in this frequency range can easily and harmfully influence...
-
The influence of frequency controlled ac drives on vibration and audible noise level on ships
PublicationOkreślono korelacje między zakłóceniami elektrycznymi a wibracjami i hałasem w okrętowych układach napędowych z przemiennikami częstotliwości. Wskazano na destrukcyjny wpływ tych czynników na jakość życia załóg pływających.
-
Electron energy-loss spectra of isoxazole
Open Research DataThe data set contains numeric values of electron energy-loss spectra measured in isoxazole in the excitation energy range 3.5−10 eV. The data have been published in graphical form (figure 3 and figure 4) in the following paper:Ireneusz Linert, Mariusz Zubek "Excited states of isoxazole molecules studied by electron energy-loss spectroscopy"Journal...
-
Electron energy-loss spectra of pyridazine
Open Research DataThe data set contains numeric values of electron energy-loss spectra measured in pyridazine in the excitation energy range 2.5−10 eV. The data have been published in graphical form (figures 3 - 6) in the following paper:
-
An Approach to Mean Path Loss Model Estimation for Off-Body Channels
PublicationThis paper presents an approach to estimation of the mean path loss model parameters in off-body Body Area Networks channels. In this approach, the path loss exponent is constrained to a value obtained for the line-of-sight (LoS) propagation in the co-polarised channel, considering a generalised static scenario. The comparison of the goodness of fit between the proposed approach and other approaches, for a set of measurements obtained...
-
Excited states of isoxazole molecules studied by electron energy-loss spectroscopy
PublicationElectron energy-loss spectra were measured in isoxazole in the excitation energy range 3.5−10 eV to investigate the valence excited states. Spectra recorded at different scattering conditions enabled the identification of the singlet and triplet states and the determination of their vertical excitation energies. The two lowest energy triplet bands, ππ* 13A' and ππ* 23A' at 4.20 and 5.30 eV, respectively show vibrational progressions....
-
User Mobility’s Influence on System Loss in Off-Body BAN Scenarios
PublicationIn this paper, a measurement campaign for off-body communications in an indoor environment is investigated for a set of on-body antennas. The channel impulse response was measured with the user approaching and departing from an off-body fixed antenna using two user dynamics: standing at fixed positions and walking. The processing of the measurement data allowed to evaluate system loss statistics. Different antenna configurations...
-
Influence of User Mobility and Antenna Placement on System Loss in B2B Networks
PublicationIn this paper, the influence of user mobility and on-body antenna placement on system loss in body-to-body communications in indoor and outdoor environments and different mobility scenarios is studied, based on system loss measurements at 2.45 GHz. The novelty of this work lies on the proposal of a classification model to characterise the effect of user mobility and path visibility on system loss, allowing to identify the best...
-
Impedance-based sensing of the interlayer adhesion loss in organic coating systems
Publication -
Sudden Hearing Loss Treated With Hyperbaric Oxygen (HBO) – Case Study
Publication -
Electron energy-loss spectroscopy of excited states of the diazine molecules: Pyridazine
PublicationExcitation of the valence electronic states of the pyridazine molecules in the gas phase have been studied using the technique of electron energy-loss spectroscopy. Varying the electron scattering conditions, the residual electron energy and scattering angle, enabled the optically-allowed and -forbidden excitations to be differentiated. The measured energy-loss spectra enabled the vertical excitation energies of the observed states...
-
Determination of Mechanical Energy Loss in Steady Flow by Means of Dissipation Power
PublicationWhen systems of simple geometry like pipes or regular channels are considered, the mechan- ical energy loss of the fluid flow can be expressed by local and longitudinal empirical energy loss coefficients. However, in the case of large spatially distributed objects, there are no simple approaches to this task. In practice, general recommendations addressing different types of objects are used, but they usually provide very coarse...
-
Path Loss Measurements in Wideband Radio Link Designed for Maritime Environment
PublicationIn the article, the research and analysis of path loss in designed and evaluated digital radio link for high-speed data transmission in maritime environment is presented. Collected samples of received signal were used to determine the mean path loss and its standard deviation. Measuring campaign was carried out in a real maritime conditions. The mean value of path loss reached 126 dB on a distance of 11.16 km.
-
Empirical formulas for determination of the propagation loss in urban radio access links
PublicationOpisano wielowariantowy model empiryczny tłumienia propagacyjnego przeznaczonego do analizowaniai projektowania radiowych systemów dostępwych w warunkach zabudowy miejskiej, opracowanego na podstawie obszernych pomiarów tego tłumienia w rzeczywistych warunkach takiej zabudowy. Scharakteryzowano przydatność użytkową tego modelu.
-
Impedance-based sensing of the interlayer adhesion loss in organic coating systems.
PublicationZmienne parametry środowiska takie jak: temperatura,wilgotność i promieniowanie UV powodują degradację własności ochronnych powłok organicznych. Stosując sensor w postaci elektrod wykonanych z prądoprzewodzącego tuszu umieszczonych pomiędzy warstwami zestawu oraz technikę spektroskopii impedancyjnej stwierdzono możliwość monitorowania utraty adhezji międzywarstwowej.
-
Volume efficiency loss in axial pumps caused by working fluid compressibility.
PublicationPrzedstawiono teoretyczną analizę wpływu ściśliwości cieczy roboczej konstrukcji mechanizmu rozrządu pompy wielotłoczkowej osiowej na straty energetyczne w przestrzeni martwej. Podano wyniki uzyskane dla typowych konstrukcji.
-
On the Possibilities of Decreasing Power Loss in Large Tilting Pad Thrust Bearings
PublicationJournal Menu About this Journal Abstracting and Indexing Aims and Scope Article Processing Charges Articles in Press Author Guidelines Bibliographic Information Citations to this Journal Contact Information Editorial Board Editorial Workflow Free eTOC Alerts Publication Ethics Submit a Manuscript Table of Contents Abstract Full-Text PDF Full-Text HTML...
-
Efficiency of Artificial Intelligence Methods for Hearing Loss Type Classification: an Evaluation
PublicationThe evaluation of hearing loss is primarily conducted by pure tone audiometry testing, which is often regarded as golden standard for assessing auditory function. If the presence of hearing loss is determined, it is possible to differentiate between three types of hearing loss: sensorineural, conductive, and mixed. This study presents a comprehensive comparison of a variety of AI classification models, performed on 4007 pure tone...
-
Experimental and numerical study on stability loss of innovative geometry steel girder
PublicationThis paper presents the experimental and numerical analysis of an innovative plate girder geometry with variable web thicknesses. An idea proposed in this research is to increase the stability of the girder web by increasing its thickness in the compressed zone. This solution can replace commonly used longitudinal stiffeners which are designed to prevent web local loss of stability. Moreover, such an innovative approach requires...
-
Influence of User Mobility on System Loss and Depolarization in a BAN Indoor Scenario
PublicationIn this article, an analysis of system loss and depolarization in body area networks (BANs) for body-toinfrastructure (B2I) communications based on a measurement campaign in the 5.8 GHz band in an indoor environment is performed. Measurements were performed with an off-body antenna transmitting linearly polarized signals and dual-polarized receiving antennas carried by the user on the body. A normal distribution with a mean of...
-
Empirical Relationship Describing Total Convective and Radiative Heat Loss in Buildings
PublicationOn the basis of theoretical considerations of convective-radiative heat transfer, a relationship was developed enabling the total convective and radiative heat flux QC+R emitted from any object at tw and its surroundings at t∞ to be calculated from known values of the surface temperature of such an object, i.e., the known temperature difference Δt=tw - t∞ and average air temperature Tav. This relationship is applied to thermal...
-
System Loss Model for Body-to-Body Networks in Indoor and Outdoor Environments
PublicationA system loss model for body-to-body networks in indoor and outdoor environments is proposed in this paper, based on measurements taken at 2.45 GHz. The influence of the type of environment, antenna visibility and user mobility on model parameters has been investigated. A significant impact of mutual antennas’ placement and their visibility is shown. The proposed model fits well to empirical data, with the average root mean square...
-
Analysis of AC/DC/DC Converter Modules for Direct Current Fast-Charging Applications
PublicationThe paper is a comprehensive laboratory comparison study of two galvanic isolated solution off-board battery chargers: (1) Si-based cost-effective case, and (2) SiC-bidirectional ready for vehicle to grid concept case. All circuits are modular, and in both cases the DC/DC converter can be replaced according to the end user requirements (the coupled transformer remains the same and is constructed based on 12xC100 cores to avoid...
-
Electrical Tree Growth Behavior Under AC and DC High Voltage in Power Cables
PublicationThis work investigates the impact of an applied AC and DC high voltage on the electrical tree behavior in extruded cross-linked polyethylene (XLPE) insulation based on simulation and experimental validation. Extensive partial discharge (PD) testing methods are being implemented for high voltage cables under AC voltage for monitoring their condition. However, these PD testing methods cannot be utilized for power cables under DC...
-
Badanie wpływu wyższych harmonicznych na czułość wyłączników różnicowoprądowych typu AC i A
PublicationW ostatnich latach coraz szerzej stosuje się pośrednie przemienniki częstotliwości i inne przekształtniki. Prądy przy zwarciach doziemnych w takich obwodach mogą być silnie odkształcone. Wyższe harmoniczne w prądzie różnicowym znacząco wpływają na działanie wyłączników różnicowoprądowych. W referacie przedstawiono wyniki badań wpływu wyższych harmonicznych prądu różnicowego na rzeczywisty prąd zadziałania wyłączników różnicowoprądowych....
-
Badanie wpływu wyższych harmonicznych na czułość wyłączników różnicowoprądowych typu AC i A
PublicationW ostatnich latach coraz szerzej stosuje się pośrednie przemienniki częstotliwości i inne przekształtniki. Prądy przy zwarciach doziemnych w takich obwodach mogą być silnie odkształcone. Wyższe harmoniczne w prądzie różnicowym znacząco wpływają na działanie wyłączników różnicowoprądowych. W artykule przedstawiono wyniki badań wpływu wyższych harmonicznych prądu różnicowego na rzeczywisty prąd zadziałania wyłączników różnicowoprądowych....
-
Jarosław Guziński prof. dr hab. inż.
PeopleJaroslaw Guzinski received M.Sc., Ph.D. and D.Sc. degrees from the Electrical Engineering Department at Technical University of Gdansk, Poland in 1994, 2000 and 2011 respectively. Since 2016 he is Associate Professor at Gdansk University of Technology. Currently he is the head of the Department of Electric Drives and Energy Conversion. From 2006 to 2009 he was involved in European Commission Project PREMAID Marie Curie, ‘Predictive...
-
Simplified Approach for Broadband RF Testing of Low Loss Magneto-Dielectric Samples
PublicationIn this paper, an attractive measurement techniqueis proposed to retrieve the broadband permittivity and permeabil-ity of the magneto-dielectric materials. The proposed techniqueis quite novel which mitigates the major problems associatedwith the conventional broadband RF material characterizationtechniques such as numerical instability and phase uncertaintywhen the length of the sample exceeds...
-
Assessment of User Mobility’s Influence on System Loss in Several Body-to-Body Scenarios
PublicationIn this paper, Body-to-Body communications in indoor and outdoor environments for different on-body antenna configurations and different mobility scenarios were studied, based on system loss measurements at 2.45 GHz. The main objective is to properly characterise the influence of the Transmitter-Receiver configuration on system loss and fast fading behaviour, the latter being modelled by the Rice Distribution. Globally, it is observed...
-
Odontogenic orbital cellulitis in a young man with complete vision loss – a case report
Publication -
Forest habitat loss and fragmentation in Central Poland during the last 100 years
Publication -
Predicting Thrust Loss of Ship Propellers Due to Ventilation and Out-of-Water Effect
Publication -
An Empirical System Loss Model for Body Area Networks in a Passenger Ferry Environment
PublicationThis paper presents a general empirical system loss model for estimating propagation loss in Body Area Networks in off-body communications at 2.45 GHz in a passenger ferry environment. The model is based on measurements, which were carried out in dynamic scenarios in the discotheque passenger ferry environment. The model consists of three components: mean system loss, attenuation resulting from the variable antenna position on...
-
Proposal of a System Loss Model for Body Area Network in Passenger Ferry Environment
PublicationIn the paper, proposal of an empirical off-body system loss model for Body Area Networks working in a passenger ferry environment at 2.45 GHz has been presented. The measurements were carried out for dynamic scenarios in the discotheque passenger ferry environment. The general model formula consists of three components: mean system loss, attenuation resulting from the variable antenna position on the human body, and attenuation...
-
An Empirical System Loss Model for Body Area Networks in a Passenger Ferry Environment
PublicationThis paper presents a general empirical system loss model for estimating propagation loss in Body Area Networks in off-body communications at 2.45 GHz in a passenger ferry environment. The model is based on measurements, which were carried out in dynamic scenarios in the discotheque passenger ferry environment. The model consists of three components: mean system loss, attenuation resulting from the variable antenna position on...
-
Modification of Selected Propagation Models in Terms of Path Loss Estimation in Container Terminal
PublicationIt is particularly important to look for any propagation model that could be useful for designing mobile radio networks in container terminal environment. Selected propagation models have been investigated. Firstly - basing on measurements results - they have been evaluated in this scope and the analysis has shown, that the adjustment is needed. This modification improved significantly the accuracy of path loss modelling. For the...
-
Multiscalar Control Based Airgap Flux Optimization of Induction Motor for Loss Minimization
PublicationBased on the induction motor model, considering the core loss resistance that accounts for magnetic characteristic saturation, a speed control approach is devised with an adaptive full-order (AFO) speed observer. The induction motor model analysis is done sincerely in a stationary reference frame. The control approach incorporates a flux reference generator designed to meet optimal operational circumstances and a nonlinear speed...
-
Automated hearing loss type classification based on pure tone audiometry data
PublicationHearing problems are commonly diagnosed with the use of tonal audiometry, which measures a patient’s hearing threshold in both air and bone conduction at various frequencies. Results of audiometry tests, usually represented graphically in the form of an audiogram, need to be interpreted by a professional audiologist in order to determine the exact type of hearing loss and administer proper treatment. However, the small number of...
-
Inlet air fogging of marine gas turbine in power output loss compensation
PublicationThe use of inlet air fogging installation to boost the power for gas turbine engines is widely applied in the power generation sector. The application of fogging to mechanical drive is rarely considered in the literature [1]. This paper will cover some considerations relating to its application to gas turbines in ship drive. There is an important evaporative cooling potential throughout the world when the dynamic data is evaluated,...
-
Detecting type of hearing loss with different AI classification methods: a performance review
PublicationHearing is one of the most crucial senses for all humans. It allows people to hear and connect with the environment, the people they can meet and the knowledge they need to live their lives to the fullest. Hearing loss can have a detrimental impact on a person's quality of life in a variety of ways, ranging from fewer educational and job opportunities due to impaired communication to social withdrawal in severe situations. Early...
-
The new SDMT-family of servo-drives for CNC systems with AC permanent magnet synchronous motors
PublicationW artykule przedstawiono strategię sterowania podstawowe parametry oraz wyniki badań nowej rodziny serwonapędów typu SDMT. Układ sterowania serwonapędu zbudowano na procesorze sygnałowym TMS320F2812 firmy Texas Instruments. W serwonapędzie zastosowano metodę sterowania tupu FOC (ang. Field Oriented Control). Regulatory położenia, prędkości i momentu zreali-zowano na bazie klasycznego regulatora PID z układem ograniczenie sygnału...
-
Modeling of Common Mode Currents Induced by Motor Cable in Converter Fed AC Motor Drives
PublicationInvestigation of conducted EMI generation in AC motor fed by pulse width modulated frequency converters requires to consider parasitic capacitances in converters, motor windings and feeding cables to be taken into account. Motor voltage transients and related common mode currents are significantly correlated with resonance effects occurring in load circuits. An analysis of frequency converter load impedance-frequency characteristics...
-
DC and AC Conductivity, Biosolubility and Thermal Properties of Mg-Doped Na2O–CaO–P2O5 Glasses
PublicationBioactive glasses have recently been extensively used to replace, regenerate, and repair hard tissues in the human body because of their ability to bond with living tissue. In this work, the effects of replacing Na2O with MgO on the electrical, biosolubility, and thermal properties of the target glass 10Na2O–60P2O5–30CaO (in mol%) were investigated. The electrical properties of the glasses were studied with the impedance spectroscopy...
-
Feasibility Study of Three-Phase Modular Converter for Dual-Purpose Application in DC and AC Microgrids
PublicationThe modern concept of a universal converter is intended as a power converter (PC) suitable for application in both dc or ac grids using the same external connectors. This novel family was recently proposed to allow easier integration of renewable energy sources and energy storage systems (ESSs), interfacing with dc/ac grids and/or loads with a minimum redundancy of power switches and passive elements. This kind of solution and...
-
Feasibility Study of Three-Phase Modular Converter for Dual-Purpose Application in DC and AC Microgrids
PublicationThe modern concept of a universal converter is intended as a power converter suitable for application in both dc or ac grids using the same external connectors. This novel family was recently proposed to allow an easier integration of renewable energy sources and energy storage systems, interfacing with dc/ac grids and/or loads with a minimum redundancy of power switches and passive elements. This kind of solution and applications...
-
RCDs Tripping in the Range from DC to AC 50 kHz for Slowly Rising Residual Current
PublicationThe wide use of power electronic converters means that in many low-voltage systems earth fault currents containing components from DC to AC of various frequencies have to be taken into account. Due to the tendency to increase the modulation frequency in converters, components of higher frequencies may be in the order of several tens of kilohertz. Therefore, it is very important to verify the behavior of devices for protection against...