Filtry
wszystkich: 6054
wybranych: 5223
-
Katalog
- Publikacje 5223 wyników po odfiltrowaniu
- Czasopisma 128 wyników po odfiltrowaniu
- Konferencje 2 wyników po odfiltrowaniu
- Osoby 79 wyników po odfiltrowaniu
- Projekty 9 wyników po odfiltrowaniu
- Kursy Online 72 wyników po odfiltrowaniu
- Wydarzenia 4 wyników po odfiltrowaniu
- Dane Badawcze 537 wyników po odfiltrowaniu
Filtry wybranego katalogu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: DRINKING WATER CONTAMINATIONDRINKING WATER DISTRIBUTION SYSTEMNEURAL NETWORKLVQ CLASSIFIERCONTAMINATION SOURCES IDENTIFICATIONMONITORING STATION LOCATION
-
The effect of using jug-type water filters on selected metals concentration in tap water – a case study
PublikacjaIn this study, the effect of the filtration process on Na, K, Mg, Ca, Fe and Zn concentration in water, using filters from one of the leading European manufacturers, was investigated. The increase in Na (up to 300%) and K concentration (up to 320%) at the beginning of jug filter usage was reported. A decrease in Ca, Fe and Zn concentration was observed. Standard filters remove 80–90% of Mg from tap water at the beginning of the...
-
Genetic solver of optimization task of mpc for optimizing control of integrated quantity and quality in drinking water distribution systems
PublikacjaPredykcyjne sterowanie zintegrowana jakością i ilością wody pitnej umożliwia uzyskanie lepszej jakości sterowania niż w przypadku innych metod. Niestety wymaga rozwiązania nieliniowego, niewypukłego problemu optymalizacji. Z tego względu potrzebne jest wykorzystanie specjalizowanego solwera w celu rozwiązania problemu optymalizacji predykcyjnej w wymaganych czasie. W tym artykule przedstawiony jest dedykowany algorytm genetyczny...
-
Characterization of PVDF/Graphene Nanocomposite Membranes for Water Desalination with Enhanced Antifungal Activity
PublikacjaSeawater desalination is a worldwide concern for the sustainable production of drinking water. In this regard, membrane distillation (MD) has shown the potential for effective brine treatment. However, the lack of appropriate MD membranes limits its industrial expansion since they experience fouling and wetting issues. Therefore, hydrophobic membranes are promising candidates to successfully deal with such phenomena that are typical...
-
Monitoring and diagnosis of quality and quantity in drinking water systems.
PublikacjaArtykuł przedstawia nowe podejście do inteligentnego monitorowania oraz diagnostyki Systemu Wodnego (WS) jako problem statusu, warunków operacyjnych oraz rozpoznawania zdarzeń. Oprogramowanie komputerowego systemu monitorowania i diagnostyki zawiera narzędzia dla identyfikacji modeli dyskretnych statusów oraz określenia parametrów ilości i jakości wody dla każdego statusu. Dla każdego stanu decyzje podejmowane są przy użyciu metody...
-
Numerical modeling of PFAS movement through the vadose zone: Influence of plant water uptake and soil organic carbon distribution
PublikacjaIn this study, we investigated the effects of soil organic carbon (SOC) distribution and water uptake by plant roots on PFAS movement in the vadose zone with a deep groundwater table under temperate, humid climate conditions. Two series of numerical simulations were performed with the HYDRUS computer code, representing the leaching of historical PFOS contamination and the infiltration of water contaminated with PFOA, respectively. We...
-
Characterization of various drinking waters by new potentiometric taste sensor with lipid, lipid-like polymer membranes
PublikacjaA new sensing system comprising five all-solid-state electrodes with lipid, lipid like-polymer membranes was applied for rapid qualitative and quantitative analysis of various drinking waters. The results elaborated by chemometric methods revealed sensitivity to CO2 content in drinking water, suggesting that this sensing system could be used as a taste sensor. The ability of taste sensor to perform quantitative analysis of minerals...
-
Changes of microbiological quality of water in distribution system. Zmiany mikrobiologicznej jakości wody w sieci dystrybucyjnej.
PublikacjaW artykule przedstawiono mikrobiologiczną jakość wody podziemnej uzdatnianej w dwóch stacjach oczyszczania wody (WTP I i WTP II), w sieci dystrybucyjnej. Obie stacje uzdatniania stosują dezynfekcję za pomocą dwutlenku chloru. Badania wykazały wzrost ogólnej liczby bakterii w miarę zwiększania się odległości od stacji uzdatniania.In the paper microbiological quality of water in distribution system produced in two ground water treatment...
-
On the problem of optimised allocation of water quality sensors and actuators in DWDS
PublikacjaThe problems of water quality sensors and actuators placement in drinking water distribution systems (DWDSs) are addressed as separate, primarily. However, against the background of control systems theory, the nature of DWDSs dynamics indicates that these both problems are interdependent and impact the design of related water quality monitoring and control structures and algorithms. The research work presented in this paper is...
-
Data-driven models for fault detection using kernel pca:a water distribution system case study
PublikacjaKernel Principal Component Analysis (KPCA), an example of machine learning, can be considered a non-linear extension of the PCA method. While various applications of KPCA are known, this paper explores the possibility to use it for building a data-driven model of a non-linear system-the water distribution system of the Chojnice town (Poland). This model is utilised for fault detection with the emphasis on water leakage detection....
-
<title>Fiber optic probe for monitoring of drinking water</title>
Publikacja -
Water Solubilization Using Nonionic Surfactants from Renewable Sources in Microemulsion Systems
PublikacjaIn this study the effect of temperature, NaCl andoils (hydrocarbons: C8-C16) on the formation and solubilizationcapacity of the systems of oil/monoacylglycerols(MAG):ethoxylated fatty alcohols (CEO20)/propylene glycol(PG)/water was investigated. The effects of the surfactantmixture on the phase behavior and the concentration ofwater or oil in the systems were studied at three temperatures(50, 55, 60 C) and with varied NaCl solutions...
-
The role of heterotrophic plate count bacteria in bottled water quality assessment
PublikacjaThe ever-growing popularity of bottled water is the result of many factors. One of the most relevant is the widespread belief that bottled water is safer for drinking than tap water. In fact many literature sources describe the rapid growth of the amounts of microorganisms in bottled water samples following the bottling process. The main purpose of this article is to collect the information on the factors which may affect this...
-
Model of Nutrient and Pesticide Outflow with Surface Water to Puck Bay (Southern Baltic Sea)
PublikacjaCoastal basins are particularly exposed to the adverse impact of anthropogenic stress. In many places, despite only the seasonal increase in the number of residents, progressive urbanization and associated changes in the catchment characteristics are noticeable. Puck Bay is part of the Gulf of Gdansk and belongs to the Baltic Sea. Although the area of Puck Bay is covered by the Natura 2000 Network, this has not saved it from eutrophication...
-
Badania połączeń spawanych rurociągu wody pitnej we Włocławku, ang. Welding joints tests in drinking water pipeline.
PublikacjaCelem badań opisanych w pracy było określenie przyczyn korozji powstałej w strefie wpływu ciepła (SWC) w obwodowych połączeniach spawanych w rurociągu wody pitnej. Materiałem, z którego wykonano rurociąg to stal 304/304L. W obszarze złącza spawanego stwierdzono wżery inicjowane od niezgodności geometrycznych, gdzie mogły gromadzić się osady zwiększające udział chlorków bezpośrednio przy powierzchni rury, promujące tym procesy korozyjne....
-
Speciation of heavy metals in bottom sediments of a drinking water reservoir for Gdańsk, Poland – changes over the 14 years
PublikacjaThere was conducted a comparative study of the concentrations of heavy metals (Zn, Cu, Pb, andCd) in the surface layer of sediments collected in two investigation periods: 1999–2000 and 2013.The results demonstrated that the degree of metals pollution decreased over time. The contaminationfactors (Cf) calculated for Zn, Cu, Pb, and Cd were respectively 3.63, 3.86, 3.23, and 3.25 in thefirst period of...
-
Speciation of heavy metals in bottom sediments of drinking water reservoir for Gdansk, Poland – changes over the 14 years
PublikacjaThere was conducted a comparative study of the concentrations of heavy metals (Zn, Cu, Pb, and Cd) in the surface layer of sediments collected in two investigation periods: 1999–2000 and 2013. Theresults demonstrated that the degree of metals pollution decreased over time. The contamina-tion factors (Cf) calculated for Zn, Cu, Pb, and Cd were respectively 3.63, 3.86, 3.23, and 3.25 in the first period of research and 1.35, 3.42,...
-
Determination of organophosphorus and organonitrogen pesticides in water samples
PublikacjaPesticides are among the most dangerous environmental pollutants because of their stability, mobility and long-term effects on living organisms. Their presence in sources of drinking water, essential to life, is a particular danger. In water, these compounds can undergo transformations, leading to the production of substances of even greater toxicity. Legal regulations are in force, stipulating the highest permissible level of...
-
Accuracy analysis of a mobile station location in the cellular networks
PublikacjaJakość usług lokalizacyjnych oferowanych w sieciach komórkowych zależy od efektywności estymacji położenia terminala ruchomego. Dokładność obecnie stosowanych metod lokalizacyjnych jest niewystarczająca, szczególnie w odniesieniu do wywołań w niebezpieczeństwie. Modyfikacja istniejących algorytmów może istotnie wpłynąć na zwiększenie dokładności lokalizowania terminala ruchomego przy jednocześnie niewielkich nakładach finansowych....
-
Bounding approach to parameter estimation without prior knowledge on modeling error and application to quality modeling in drinking water distribution systems
PublikacjaW artykule rozważana jest estymacja parametrów modelu autoregresji z ruchoma średnią i sygnałem wejściowym (ARMAX) z wykorzystaniem przedziałowego modelu błędu. Zakłada się, że granice błędu struktury modelu są nieznane, bądź znane, ale bardzo konserwatywne. Dla zmniejszenia tego konserwatyzmu proponowane jest idea modeli punktowo-parametrycznych, w której występują zbiory parametrów i błędu modelu odpowiadające wszystkim wejściom....
-
Investigations On Water Circulation in Animal Sea-Water Basins – On the Example of Seals′ Breeding Pools
PublikacjaThis paper presents general comments concerning investigations on water circulation in animal breeding pools containing sea water. As an example are given results of computer simulation of water circulation in seals’ breeding pools situated in Marine Station at Hel, belonging to Oceanographic Institute, Gdansk University. A mathematical model of three main pools was prepared with taking into account their inflow and outflow water...
-
The Application of a Mobile Unmanned Device for Monitoring Water and Sediment Pollution in the Port of Gdynia
PublikacjaPollution in the Port of Gdynia can encompass various types of substances and contaminants that affect the quality of water and sediment in this region. Ships entering and leaving the port can release pollutants such as oil, fuel, waste, and chemicals into the water. Controlling and monitoring these pollutants is a crucial part of environmental stewardship. In recent years, uncrewed units have been increasingly in use for in situ...
-
Hybrid Multi-Criteria Method of Analyzing the Location of Distributed Renewable Energy Sources
PublikacjaThis paper presents the development and the application of a hybrid multi-criteria method, the combination of the Analytic Hierarchy Process (AHP), and numerical taxonomy (NT),to support the decision making on the location of distributed renewable energy sources meetingvarious types of assessment criteria. Finding criteria weights, using the AHP method, eliminates thedisadvantage of NT—which, in current form, is defined by its...
-
Sessile droplet contact angle of water–Al2O3, water–TiO2 and water–Cu nanofluids
PublikacjaThis work presents measurements of the contact angle of sessile droplets for three nanofluids, i.e. water–Al2O3, water–TiO2 and water–Cu. The plates made of glass, anodized aluminium and stainless steel of different roughness served as substrates. Ultrasonic vibration was used for 30–60 min in order to stabilise the dispersion of the nanoparticles. Nanoparticles were tested at the concentration of 0.01%, 0.1%, and 1% by weight....
-
Metrological analysis of precision of the system of delivering a water capsule for explosive production of water aerosol
PublikacjaIn this paper an analysis of precision of the system controlling delivery by a helicopter of water-capsule designed for extinguishing large scale fires is presented. The analysis was performed using the numerical method of distribution propagation (Monte Carlo method) supplemented with results of application of the uncertainty propagation method. In addition the optimum conditions for the airdrop are determined to ensure achievement...
-
Clasification of drinking water samples using the Chernoff's faces visualization approach
PublikacjaOpracowanie przedstawia wyniki zastosowania wizualizacji metodą twarzy Chernoffa w klasyfikacji obszarowych zmian jakości wody pitnej, na podstawie wyników oznaczeń chloro- i bromopochodnych produktów dezynfekcji wody w 12 dzielnicach Gdańska w okresie 1993-2000.
-
Integrated algorithm for selecting the location and control of energy storage units to improve the voltage level in distribution grids
PublikacjaThis paper refers to the issue that mainly appears in distribution grids, where renewable energy sources (RES) are widely installed. In such grids, one of the main problems is the coordination of energy production time with demand time, especially if photovoltaic energy sources are present. To face this problem, battery energy storage units (ESU) can be installed. In recent years, more and more attention has been paid to optimizing...
-
Why the Solvation Water around Proteins Is More Dense than Bulk Water
PublikacjaThe main aim of this work is to propose a rational explanation of the commonly observed phenomenon of increasing water density within solvation shell of proteins. We have observed that the geometry of the water–water hydrogen bond network within solvation layer differs from the one in bulk water, and it is the result of interactions of water molecules with protein surface. Altered geometry of the network reflects changes in the...
-
Why the solvation water around proteins is more dense than bulk water
PublikacjaThe main aim of this work is to propose a rational explanation of commonly observed phenomenon of increasing water density within solvation shell of proteins. We have observed that geometry of the water-water hydrogen bond network within solvation layer differs from the one in bulk water and it is the effect of interactions of water molecules with protein surface. Altered geometry of the network reflects changes in the structure...
-
Advanced Oxidation Processes for Degradation of Water Pollutants—Ambivalent Impact of Carbonate Species: A Review
PublikacjaAdvanced oxidation processes (AOPs) hold great promise in the removal of organic contaminants. Reactive oxygen species (ROS) produced in AOPs react with target pollutants to initially form several intermediate compounds that finally undergo complete mineralization. Such observations are reported, especially for laboratory-scale experiments performed in pure water. On the other hand, while considering real contaminated wastewater...
-
A note on the vertical distribution of momentum transport in water waves
Publikacja -
Bioaugmentation of a sequencing batch reactor with Archaea for the treatment of reject water
PublikacjaIn this study, the bioaugmentation of a sequencing batch reactor (SBR) for the treatment of reject water from wastewater treatment plant was evaluated. For the bioaugmentation step a product containing an enrichment of microorganisms from the Archaea domain was used to enhance the performance of the reactor for treating reject water. The experiment was carried out in two parallel lab-scale sequencing batch reactors. The first one...
-
Nickel in soil and water: Sources, biogeochemistry, and remediation using biochar
Publikacja -
The effect of chlorinated drinking water consumption on levels of volatile organohalogen compounds in urine.
PublikacjaW przedstawionej pracy podjęto próbę oznaczenia niezmienionych form lotnych rozpuszczalników chlorowcoorganicznych w próbkach materiału biologicznego jakim jest mocz dawców, używających w gospodarstwie domowym a także w pracy wody uzdatnianej między innymi w procesie chlorowania. Do wykonania oznaczeń zastosowano zmodyfikowaną technikę analizy fazy nadpowierzchniowej nad cienką warstwą cieczy z samoczynną generacją ciekłego sorbentu...
-
Identification and antimicrobial resistance of Enterococcus spp. isolated from surface water
PublikacjaIn the study species distributions and antimicrobial resistance profiles were determined among riverine Enterococcus spp. Susceptibility of the isolates was tested against: ampicillin, imipenem, teicoplanin, vancomycin, erythromycin, linezolid, fosfomycin, ciprofloxacin,levofloxacin, moxifloxacin, tetracycline, high levels of gentamicin and streptomycin. The enterococci were detected in all of the analyzed water samples, periodically...
-
Study of Cloud Water Samples Collected over Northern Poland
PublikacjaThe paper gives the results of the first studies on the chemistry of cloud water collected during 3 mo (Aug.–Oct. 2010) in the free atmosphere over the area to the south of the Tri-City (Gdansk-Sopot-Gdynia) conurbation on the Gulf of Gdansk, Poland. Taken from cumulus, stratus, and stratocumulus clouds by means of an aircraft-mounted collector, the water samples were analyzed for the following contaminants: anions (chlorides,...
-
Determination of the substances potentially allergenic in water
PublikacjaPersonal care chemicals are continuously released into environment through domestic and industrial wastewater, causing adverse effects on human health. Their presence can be detected in different environmental compartments. A group of chemicals included in most personal care products are the allergen fragrances. In the present work, simple and rapid methodology based on ultrasound-assisted emulsification-microextraction (USAEME)...
-
On the Limiting distribution of Lempel Ziv'78 Redundancy for Memoryles Sources
PublikacjaWe show that the Lempel Ziv'78 redundancy rate tends to a Gaussian distribution for memoryless sources. We accomplish it by extending findings from our 1995 paper [3]. We present a new simplified proof of the Central Limit Theorem for the number of phrases in the LZ'78 algorithm. As in our 1995 paper, here we first analyze the asymptotic behavior of the total path length in a digital search tree (a DST) built from independent sequences....
-
Pool Boiling of Water–Al2O3 and Water–Cu Nanofluids Outside Porous Coated Tubes
PublikacjaThis paper deals with pool boiling ofwater–Al2O3 and water–Cu nanofluids on porous coated, horizontal tubes. Commercially available stainless-steel tubes having 10 mm outside diameter and 0.6 mm wall thickness were used to fabricate a test heater. Aluminum porous coatings 0.15 mm thick with porosity of about 40% were produced by plasma spraying. A smooth tube served as a reference tube. The experiments were conducted under different...
-
Probabilistic Assessment of Correlations of Water Levels in Polish Coastal Lakes with Sea Water Level with the Application of Archimedean Copulas
Publikacja -
Analytical Techniques for Determining Pharmaceutical Residues in Drinking Water – State of Art and Future Prospects
Publikacja -
Health Risk Assessment of Exposure to Nitrates in Drinking Water Depending on the Source of Its Origin
Publikacja -
Sources of errors associated with the determination of PAH and PCB analytes in water samples
PublikacjaW pracy przedstawiono problemy związane z oznaczaniem analitów z grupy WWA i PCB w próbkach wody. Zidentyfikowano źródła błędów. Szczególną uwagę zwrócono na:- proces adsorpcji analitów na ściankach szklanych naczyń używanych w trakcie obróbki i przechowywania próbek,- wpływ etapu odparowywania nadmiaru rozpuszczalnika z ekstraktów na odzysk analitów,- wpływ materiału, z którego jest wykonana kolumienka ekstrakcyjna (szkła, polietylenu)...
-
Analytical procedures for PAH and PCB determination in water samples - error sources
PublikacjaW pracy przedstawiono poszczególne etapy procedury analitycznej wykorzystywanej do oznaczania analitów z grupy WWA i PCB w próbkach wody. Pokazano jakie problemy występują podczas oznaczania wyżej wymienionych analitów i jaki mogą mieć wpływ na końcowy wynik analizy.
-
Robust Estimation of Integrated Hydraulics and Parameters in Water Distribution Systems
Publikacja -
Robust estimation of variables and parameters in dynamic water distribution systems
PublikacjaPrzedstawiono estymację metodą ''set membership'' zmiennych i parametrów systemu dystrybucji wody pitnej. Zmienne odnoszą się do ilości i jakości wody, natomiast parametry odnoszą się do modelu matematycznego hydrauliki. Problemten jest wysoce nieliniowy. Algorytm estymacji jest oparty na wcześniejszychpracach i wykorzystuje również algorytm dynamicznej linearyzacji odcinkami.
-
On the Limiting Distribution of Lempel-Ziv’78 Redundancy for Memoryless Sources
PublikacjaWe study the Lempel-Ziv'78 algorithm and show that its (normalized) redundancy rate tends to a Gaussian distribution for memoryless sources. We accomplish it by extending findings from our 1995 paper, in particular, by presenting a new simplified proof of the central limit theorem (CLT) for the number of phrases in the LZ'78 algorithm. We first analyze the asymptotic behavior of the total path length in the associated digital search...
-
Reduction of Derivative pipeline effort in water turbine
PublikacjaThe paper presents an approach to evaluate and reduce the effort of the derivative pipeline in a water turbine of a hydrostatic power station in its vulnerable spots. Potential places of the biggest effort of the structure, as well as the coefficient of displacement and safety factor related to them were identified using FEM numerical method. Pipeline reinforcement was designed and made based on FEM analysis. Original technology...
-
Analytics of airport runoff water samples
PublikacjaThe everyday activities at airports, such as aircraft and ground vehicle washing, cleaning, de/anti-icing operations, fuelling, and fuel combustion, removing weeds are the main sources of airport industrial wastes. Runoff waters from airport areas constitute a serious environmental problem as they contribute to air, water, and soil pollution. The paper supplies general information on the technologies for treating airport runoff...
-
Rain Water: Atmospheric Deposition
PublikacjaWater is transferred from the atmosphere to the land surface mainly via various forms of atmospheric precipitation; however, the contribution of surface condensation/deposition (e.g., dew, hoar frost, occult precipitation) should not be neglected. Rainwater and liquid deposits (dew, hoar frost, rime) are components of the physical and geographical environment that are easily assimilated and transported. Thus, they are generally...
-
Water retention curves of sandy soils obtained from direct measurements, particle size distribution, and infiltration experiments
PublikacjaAccurate information about soil water retention curves (SWRCs) of sands is essential for evaluating groundwater recharge and vulnerability to contamination in many shallow sandy aquifers which are widespread on post glacial areas in Northern Europe and North America. Pedotransfer functions (PTFs) allow to estimate SWRC from basic physical characteristics of soils, such as textural composition. However, in the case of clean sands...