Filtry
wszystkich: 693
wybranych: 495
Wyniki wyszukiwania dla: impedance spectroscopy
-
Chemical-Assisted Mechanical Lapping of Thin Boron-Doped Diamond Films: A Fast Route Toward High Electrochemical Performance for Sensing Devices
PublikacjaThere is an urgent need for an effective and economically viable increase in electrochemical performance of boron-doped diamond (BDD) electrodes that are used in sensing and electrocatalytic applications. Specifically, one must take into consideration the electrode heterogeneity due to nonhomogenous boron-dopant distribution and the removal of sp2 carbon impurities saturating the electrode, without interference in material integrity....
-
Enhanced susceptibility of SARS-CoV-2 spike RBD protein assay targeted by cellular receptors ACE2 and CD147: Multivariate data analysis of multisine impedimetric response
PublikacjaSevere acute respiratory syndrome coronavirus 2 (SARS-CoV-2) enters the cells through the binding of spike protein to the host cell surface-expressing angiotensin-converting enzyme 2 (ACE2) or by endocytosis mediated by extracellular matrix metalloproteinase inducer (CD147). We present extended statistical studies of the multisine dynamic electrochemical impedance spectroscopy (DEIS) revealing interactions between Spike RBD and...
-
Conductive printable electrodes tuned by boron-doped nanodiamond foil additives for nitroexplosive detection
PublikacjaAn efficient additive manufacturing-based composite material fabrication for electrochemical applications is reported. The composite is composed of commercially available graphene-doped polylactide acid (G-PLA) 3D printouts and surface- functionalized with nanocrystalline boron-doped diamond foil (NDF) additives. The NDFs were synthesized on a tantalum substrate and transferred to the 3D-printout surface at 200 °C. No other electrode...
-
Study of anticorrosion and microwave absprption properties of NiZn ferrite pigments
PublikacjaPurpose - The purpose of this paper is to report the electrochemical verification of anticorrosive properties of NiZn ferrites as pigments in protective coatings and evaluation of their microwave absorbing properties. Design/methodology/approach - Ferrites, represented by formula NixZn(1-x)Fe2O4, where x=0, 0.2, 0.4, 0.6, 0.8, 1.0, were synthesized using a ceramic method. The samples of ferrites were examined by X-ray diffraction...
-
Influence of iron content on water uptake and charge transport in BaCe0.6Zr0.2Y0.2−xFexO3−δ triple-conducting oxides
PublikacjaIn this work, we studied the BaCe0.6Zr0.2Y0.2−xFexO3−δ system which belongs to the triple-conducting oxides (TCOs) group. The electrochemical properties of BaCe0.6Zr0.2Y0.2−xFexO3−δ were investigated using electrochemical impedance spectroscopy (EIS) and the water uptake was analyzed using thermogravimetry (TG). All investigated materials exhibited water uptake, with proton concentration increasing with decreasing iron content....
-
Investigating the Impact of Curing System on Structure-Property Relationship of Natural Rubber Modified with Brewery By-Product and Ground Tire Rubber
PublikacjaThe application of wastes as a filler/reinforcement phase in polymers is a new strategy to modify the performance properties and reduce the price of biocomposites. The use of these fillers, coming from agricultural waste (cellulose/lignocellulose-based fillers) and waste rubbers, constitutes a method for the management of post-consumer waste. In this paper, highly-filled biocomposites based on natural rubber (NR) and ground tire...
-
Scalable Route toward Superior Photoresponse of UV-Laser-Treated TiO2 Nanotubes
PublikacjaTitanium dioxide nanotubes gain considerable attention as a photoactive material due to chemical stability, photocorrosion resistance, or lowcost manufacturing method. This work presents scalable pulsed laser modification of TiO2 nanotubes resulting in enhanced photoactivity in a system equipped with a motorized table, which allows for modifications of both precisely selected and any-large sample area. Images obtained from scanning...
-
Multi-pathway mechanism of polydopamine film formation at vertically aligned diamondised boron-doped carbon nanowalls
PublikacjaBoron-doped carbon nanowall (B:CNW) electrodes were used as a platform for studying the electropolymerisation of dopamine. Due to the unique properties of B:CNW, including the fast charge-transfer kinetics and high surface conductivity, a high degree of reversibility of redox reactions was achieved. Three separated redox peaks were observed on voltammograms and attributed to three fundamental reactions in the dopamine polymerisation...
-
Corrosion Inhibition Mechanism and Efficiency Differentiation of Dihydroxybenzene Isomers Towards Aluminum Alloy 5754 in Alkaline Media
PublikacjaThe selection of efficient corrosion inhibitors requires detailed knowledge regarding the interaction mechanism, which depends on the type and amount of functional groups within the inhibitor molecule. The position of functional groups between different isomers is often overlooked, but is no less important, since factors like steric hinderance may significantly affect the adsorption mechanism. In this study, we have presented how...
-
Aluminum-TiO2 NPs Composites as Non-precious Catalysts for Efficient Electrochemical Generation of Hydrogen
PublikacjaIn this paper, we demonstrated, for the first time, aluminum titania nanoparticle (Al-TiO2 NP) composites with variable amounts of TiO2 NPs as nonprecious active catalysts for the electrochemical generation of H2. These materials were synthesized by mixing desired amounts of hydrogen titanate nanotubes (TNTs), fabricated here by a cost-effective approach at moderate hydrothermal conditions, with aluminum powder (purity 99.7%; size...
-
Evaluating the impact of ZnO doping on electrical and thermal properties of calcium-aluminosilicate oxynitride glass-ceramics
PublikacjaThis study aimed to investigate the impact of ZnO content on the structure, thermal, and electrical properties of oxynitride glass-ceramic(s) within the Ca–Al–Si–O–N (CASON) system. The base glass had the composition of Ca7Al14Si17O52N7, with ZnO additions ranging from 3 to 15 % by weight. A pristine Ca7Al14Si17O52N7 glass was successfully prepared by melt-quenching technique followed by converted into glass-ceramic by incorporating various...
-
Tailoring diamondised nanocarbon-loaded poly(lactic acid) composites for highly electroactive surfaces: extrusion and characterisation of filaments for improved 3D-printed surfaces
PublikacjaA new 3D-printable composite has been developed dedicated to electroanalytical applications. Two types of diamondised nanocarbons - detonation nanodiamonds (DNDs) and boron-doped carbon nanowalls (BCNWs) - were added as fillers in poly(lactic acid) (PLA)-based composites to extrude 3D filaments. Carbon black served as a primary filler to reach high composite conductivity at low diamondised nanocarbon concentrations (0.01 to 0.2...
-
Tuning Electrochemical Performance by Microstructural Optimization of the Nanocrystalline Functional Oxygen Electrode Layer for Solid Oxide Cells
PublikacjaFurther development of solid oxide fuel cell (SOFC) oxygen electrodes can be achieved through improvements in oxygen electrode design by microstructure miniaturisation alongside nanomaterials implementation. In this work, improved electrochemical performance of an La0.6Sr0.4Co0.2Fe0.8O3-d (LSCF) cathode was achieved by the controlled modification of the La0.6Sr0.4CoO3-d (LSC) nanocrystalline interlayer introduced between a porous...
-
Improved degradation of etodolac in the presence of core-shell ZnFe2O4/SiO2/TiO2 magnetic photocatalyst
PublikacjaIn the present study, susceptibility to photocatalytic degradation of etodolac, 1,8-diethyl-1,3,4,9 – tetrahydro pyran - [3,4-b] indole-1-acetic acid, which is a non-steroidal anti-inflammatory drug frequently detected in an aqueous environment, was for the first time investigated. The obtained p-type TiO2-based photocatalyst coupled with zinc ferrite nanoparticles in a core-shell structure improves the separation and recovery...
-
Local impedance imaging of boron-doped polycrystalline diamond thin films
PublikacjaLocal impedance imaging (LII) was used to visualise surficial deviations of AC impedances in polycrystalline boron-doped diamond (BDD). The BDD thin film electrodes were deposited onto the highly doped silicon substrates via microwave plasma-enhanced CVD. The studied boron dopant concentrations, controlled by the [B]/[C] ratio in plasma, ranged from 1 × 1016 to 2 × 1021 atoms cm−3. The BDD films displayed microcrystalline structure,...
-
IMPEDANCE MEASUREMENT MODULE FOR GAS SENSORS WITH TEMPERATURE CONDITIONING FEATURE
PublikacjaThe paper presents an impedance measurement module which is aimed for gas sensor. Sensor’s heater temperature conditioning and modulation feature is available in order to allow implementation of different techniques improving selectivity and sensitivity of gas sensors. The measurement module uses three-parameter sine-fitting technique for impedance measurement. To monitor sensor temperature, the resistance of the sensor’s heater...
-
Catalytic impact of alloyed Al on the corrosion behavior of Co50Ni23Ga26Al1.0 magnetic shape memory alloy and catalysis applications for efficient electrochemical H2 generation
PublikacjaThe electrochemical and corrosion behaviour of Co50Ni23Ga27-xAlx (x = 0 and 1.0 wt%) magnetic shape memory alloys (MSMAs) was studied in 0.5 M NaCl solutions using various electrochemical techniques. Results showed remarkable activation of the tested MSMA toward pitting corrosion upon alloying it with Al. XPS examination confirmed the activation influence of alloyed Al. It proved that the presence of Al in the alloy's matrix weakens...
-
Charge Transport in High-Entropy Oxides
PublikacjaThis work presents the results of research on the transport properties of the high-entropy BaZr1/8Hf1/8Sn1/8Ti1/8Y1/8In1/8Sm1/8Yb1/8O3–x perovskite oxide with special focus on proton transport. The presented study is part of broader work in which we focus on multiple different chemical compositions with the cation number varying from 5 up to 12 (in B-sublattice). The presence of proton defects is analyzed with thermogravimetry,...
-
Application of multisine nanoscale impedance microscopy to heterogeneous alloy surface investigations
PublikacjaIn the recent years atomic force microscopy is recognized as valuable tool for investigation of surficial features of construction materials. It concerns, among other things, studies of changes caused by such phenomena as galvanic corrosion, passivation associated with the growth of oxide layers, or sensitization of austenitic steels with the formation of carbide phases. In addition, atomic forcemicroscopy allows easy coupling...
-
Impedance of cation-coupled electron transfer reaction: Theoretical description of one pathway process
PublikacjaIt has been assumed that cation electron coupled charge transfer can be conducted in accordance with two mutually coupled reactions. Using a differential method an expression was introduced which describes the impedance of a cation electron coupled transfer reaction. Also, an electrical equivalent circuit has been defined. The total faradaic impedance is the sum of electron transfer impedance and cation transfer impedance. Issues...
-
Signature of Oxide-Ion Conduction in Alkaline-Earth-Metal-Doped Y3GaO6
PublikacjaWe have studied alkaline-earth-metal-doped Y3GaO6 as a new family of oxide-ion conductor. Solid solutions of Y3GaO6 and 2% −Ca2+-, −Sr2+-, and −Ba2+-doped Y3GaO6, i.e., Y(3−0.06)M0.06GaO6−δ (M = Ca2+, Sr2+, and Ba2+), were prepared via a conventional solid-state reaction route. X-ray Rietveld refined diffractograms of all the compositions showed the formation of an orthorhombic structure having the Cmc21 space group. Scanning electron...
-
Miniaturized impedance analyzer using AD5933
PublikacjaThe paper presents the analyzer allowing to measure impedance in a range of 10 ohms <|Zx|<10 Gohms in a wide frequency range from 10 mHz up to 100 kHz. The device specific features are: miniaturization, low power consumptions and the use of impedance measurement method based on DSP. These features were possible thanks to the use of newest generation of large scale integration chips: e.g. „system on a chip” microsystems (AD5933)...
-
Miniaturized impedance analyzer using AD5933
PublikacjaThe paper presents the analyzer allowing to measure impedance in a range of 10 ohms <|Zx|<10 Gohms in a wide frequency range from 10 mHz up to 100 kHz. The device specific features are: miniaturization, low power consumptions and the use of impedance measurement method based on DSP. These features were possible thanks to the use of newest generation of large scale integration chips: e.g. „system on a chip” microsystems (AD5933)...
-
Programmable dynamically changing RC model for evaluation of Dynamic EIS methods and instrumentation
PublikacjaThe paper concerns the RC equivalent circuit of electrochemical cell with the impedance changed during the experiment. The model was constructed using the digital potentiometers controlled by the microcontroller. This solution allows to control the model impedance by the software means. By creating adequate changes of the impedance spectrum as a time function, the different impedance measurement method can be tested to find out...
-
Using A Particular Sampling Method for Impedance Measurement
PublikacjaThe paper presents an impedance measurement method using a particular sampling method which is an alternative to DFT calculation. The method uses a sine excitation signal and sampling response signals proportional to current flowing through and voltage across the measured impedance. The object impedance is calculated without using Fourier transform. The method was first evaluated in MATLAB by means of simulation. The method was...
-
Enhanced Spectroscopic Insight into Acceptor-Modified Barium Strontium Titanate Thin Films Deposited via the Sol–Gel Method
PublikacjaIn the present paper, composite thin films of barium strontium titanate (BaxSr1−xTiO3) with an acceptor modifier (magnesium oxide—MgO) were deposited on metal substrates (stainless steel type) using the sol–gel method. The composite thin films feature BaxSr1−xTiO3 ferroelectric solid solution as the matrix and MgO linear dielectric as the reinforcement, with MgO concentrations ranging from 1 to 5 mol%. Following thermal treatment...
-
Modelling of dielectric properties of BiNbO4-based microwave ceramics
PublikacjaIn the present paper results of the studies devoted to computer simulations of dielectric response of electroceramics in a frequency domain as well as analysis of the experimental data are given. As an object of investigations BiNbO4-based microwave ceramics was taken. Simulations of the hypothetical impedance response of the ceramic system were performed under assumption of the brick-layer model. A strategy for analysis and modelling...
-
Recycled rubber wastes-based polymer composites with flame retardancy and electrical conductivity: Rational design, modeling and optimization
PublikacjaPolymer recycling techniques experience a maturity period of design and application. Rubbers comprise a high proportion of polymer wastes, highly flammable and impossible to re-melt. Polymer composites based on ground tire rubber (GTR) and ethylene-vinyl acetate copolymer (EVA) containing carbon black (CB) (1–50 phr), with variable EVA/GTR weight composition (10/90, 25/75, 50/50, 75/25 and 90/10), and processing temperature (Low:...
-
Analysis of the Possibility of Using New Types of Protective Coatings and Abrasion-Resistant Linings under the Operating Conditions of the Spiral Classifier at KGHM Polska Miedź S.A. Ore Concentration Plant
PublikacjaA study was carried out to select the appropriate coatings for corrosion protection of the spiral classifier working at KGHM Polska Miedź S.A. Ore Concentration Plant. The abrasion resistance of selected protective coatings and wear-resistant linings was investigated using a DT-523 rotary abrasion tester with Taber CS-10 rubber abrasive discs. The average weight loss of the coatings after a cycle of 2000 revolutions was determined....
-
A complete impedance analysis of electrochemical cells used as energy sources
PublikacjaA comprehensive description of impedance ofelectrochemical systems has been presented, along withthe assumptions of the method used. In this method, amultisinusoidal current excitation signal is used. Thechanges of potential of both the electrodes and thepotential difference between these electrodes are allregistered simultaneously as a function of time. Theproposed method offers the possibility of separatelydetermining the instantaneous...
-
Uncertainty estimation of loop impedance measurement determined by the vector method
PublikacjaThis article presents a detailed analysis of uncertainty estimation of loop impedance measurement determined by the vector method. The analysis includes the following estimates: resistance variance, voltage variance and time measurement variance. This paper presents a methodology for estimating the combined standard uncertainty of loop impedance by the vector method. The vector method allows to determine loop impedance based on...
-
Platform Supporting the Esophageal Impedance Analysis
PublikacjaThe esophageal pH-impedance examination is one of the most popular diagnostic methods for identifying the upper gastrointestinal tract’s diseases. Inconclusive test evaluation criteria makes it difficult to state the definite diagnosis. In this paper, the computer platform supporting the research and teaching process in the area of pH-impedance analysis is presented. Users, having a variety of mathematical and statistical methods...
-
Ellipse-fitting algorithm implementation in the impedance measurement system based on DAQ card with FPGA
PublikacjaThe paper presents an implementation of the ellipse-fitting algorithm in the impedance measurement system based on DAQ card equipped with FPGA chip. The method implementation was tested by simulation means as well as experimentally in the designed and presented measurement system. Finally, the limit values of sampling parameters which assures satisfying accuracy were given.
-
Assessment of organic coating degradation via local impedance imaging
PublikacjaThe paper presents a new approach to organic coating condition evaluation at micrometer scale using localized impedance measurements. It is based on atomic force microscopy (AFM) in contact mode. Impedance is measured between conductive AFM tip and metal substrate covered with organic coating. A single-frequency voltage perturbation signal is applied between the electrodes and current response signal is registered. As the tip is...
-
A family of new generation miniaturized impedance analyzers for technical object diagnostics
PublikacjaThe paper presents the family of three analyzers allowing to measure impedance in range of 10 ohm<|Zx|<10 Gohm in a wide frequency range from 10 mHz up to 100 kHz. The most important features of the analyzers family are: miniaturization, low power consumption, low production cost, telemetric controlling and the use of impedance measurement method based on digital signal processing DSP. The miniaturization and other above mentioned...
-
Determination of time dependence of coated metal electrical and electrochemical parameters during exposure using principal component analysis
PublikacjaThe use of the principal component analysis (PCA) permits the complex and quantitative analysis of the time dependence of electrical and electrochemical parameters of coated metal obtained by fitting impedance data. So far, changes in electrical and electrochemical parameters during exposure were analyzed independently. In this way, some of the information contained in the relationship between changes in parameters over time are...
-
A method of measuring RLC components for microcontroller systems
PublikacjaA new method of measuring RLC components for microcontroller systems dedicated to compact smart impedance sensors based on a direct sensor-microcontroller interface is presented. In the method this direct interface composed of a reference resistor connected in series with the tested sensor impedance is stimulated by a square wave generated by the microcontroller, and then its voltage response is sampled by an internal ADC of the...
-
Electrical Propterties of Solution Mixtures for Bath Supervision in Ambient Assisted Living
PublikacjaImpedance properties of bath solution are compared. Any ingredient such as soap, shampoo or bathing salt changes bath-solution’s electrical properties eg. impedance. We have measured and analysed influence of typical bathing ingredients on electrical properties of the solution. We investigate impedance changes over frequency range from 100Hz tu 100kHz as it is most applicable for person detection. Electrical properties of bath...
-
Selected problems of earth fault loop impedance testing in circuits fed from UPS
PublikacjaIn the paper a principle of earth fault loop impedance testing in low voltage systems has been presented. Selected factors, influencing accuracy of the testing, are indicated. A structure of UPS of VFI-type and the problem of impedance testing in circuits with such type of UPS are discussed.
-
Influence of vacuum sublimation deposited metal layer thickness on metrological parameters of the amperometric gas sensor with Nafion membrane
PublikacjaThe paper presents the results of investigation on an influence of vacuum sublimation deposited platinum layer thickness on the signal, sensitivity and response time of a prototype of sulphur dioxide sensor with Nafion membrane. The working electrode was made by vacuum sublimation deposition of platinum on a surface of Nafion membrane. Pt layers deposited changed an initial structure of Nafion membrane and that phenomenon was utilized...
-
Fault Loop Impedance Measurement in Circuits Fed by UPS and Principle of Safety Protection
PublikacjaThis paper indicates a significant problem of uncertainty of fault loop impedance (FLI) measurement in circuits powered from uninterruptible power supply (UPS) (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers...
-
Investigation on accelerated impedance spectrum measurement method with multisine signal stimulation
PublikacjaThe paper presents an investigation on the accelerated impedance spectrum measurement method, oriented at parameter identification of technical objects modelled by a linear equivalent circuit, e.g. anticorrosion coatings.The method is based on multisine signal stimulation of an object and response analysis by triangle window filterbanks.It has several advantages, as compared with conventional point-by-point spectrum measurement....
-
Nonlinear impedance in oxide glasses containing single and mixed alkali ions
PublikacjaThe aim of the present was to find more clues on the nonlinearities in impedance of oxide glasses. The first family of researched glasses has a composition of FeO-P2O5-Na2O. Oxide glasses containing iron and alkali are well known for a very low alkali ion mobility and may be considered purely polaron conducting. These glasses show no detectable nonlinearities in the impedance spectra. The second was a family of ionic conducting...
-
Nonlinear Impedance as Possible Result of Ion-Polaron Interaction in Cu2O-Al2O3-SiO2 Glass
PublikacjaNonlinear a.c. impedance measurements were performed in Cu2O-Al2O3-SiO2 glass in wide frequency range. The obtained results shows that a large nonlinearity in the impedance signal is observed at moderate electric fields of an order 1V/mm. The contents of the third harmonics reaches about 10% and strongly depends on temperature and frequency. The investigated glass exhibits mixed electronic-ionic conductivity. Electronic conduction...
-
Adaptive estimation of the transformer stray capacitances for DC–DC converter modelling
PublikacjaNew low cost and accurate estimation method of transformer stray capacitances for wide band DC–DC converter modelling and design is proposed. The Wiener filter (WF) method is applied to estimate the transformer impedance – referred to the selected transformer winding configurations. Laboratory tests are used to adapt the filter, that is to find optimal impedance which minimises mean square error between measured, noise perturbed...
-
Electronic conductivity in the SiO2-PbO-Fe2O3 glass containing magnetic nanostructures
PublikacjaThe linear impedance spectra of iron–silicate–lead glass samples were measured in the frequency range from 1 MHz to 1 MHz and in the temperature range from 153 K to 423 K. The structure was investigated by means of XRD and atomic force microscopy. Local electrical and magnetic properties of the samples were tested with the aid of electrostatic force microscopy (EFM) and magnetic force microscopy (MFM). The obtained results show...
-
Optimal configuration of an electrode array for measuring ventricles' contraction
PublikacjaAn influence of an electrode-array configuration on an impedance signal composition for a fixed spatial distribution of its sources is examined in the paper. The Finite Element Method and Geselowitz relationship were used for examining three different electrode-arrays. A sensitivity approach was used to evaluate each configuration assuming that localization of the signal source is known. A conductivity change, thus the source of...
-
Monitoring of CRT by means of impedance multiple measurements - simulation studies
PublikacjaCardiac resynchronization therapy (CRT) is a very promising treatment for patients with congestive heart failure. An Impedance Cardiography (ICG) is used for evaluation of heart mechanical activity. A simulation study with the use of a FEM model was performed. The developed realistic model of the thorax, based on CT data obtained from examination of a 68-year-old man, consisted of 212 000 tetrahedral elements. Different configurations...
-
Analysis of thoracic regional impedance changes using PCA approach
PublikacjaA multichannel impedance and one lead electrocardiographic recording system has been developed. The impedance measurement unit is built using a four-electrode technique. It consists of a sinusoidal, 40 kHz, current source and five measurement channels. Circumferential current electrodes have been located at a neck and an abdomen. Voltagemeasurement disk electrodes formed five two-electrode measurement ports. The impedance change...
-
Optimization of the Relative Humidity of Reactant Gases in Hydrogen Fuel Cells Using Dynamic Impedance Measurements
PublikacjaWater management is a key factor affecting the efficiency of proton exchange membrane fuel cells (PEMFCs). The currently used monitoring methods of PEMFCs provide limited information about which processes or components that humidity has a significant impact upon. Herein, we propose the use of a novel approach of impedance measurements using a multi-sinusoidal perturbation signal, which enables impedance measurements under dynamic...